Search NASA⌕ Search

SEARCH · Search NASA

Results for “reflectance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High spectral resolution in the solar spectrum

A session dedicated to high spectral resolution in the solar spectrum, covering topics of calibration, atmospheric correction, geology/pedology, inland water, and vegetation, is reported. The session showed a high degree of diversity in the topics and the approaches used. It was highlighted that high spectral resolution data could provide atmospherically corrected ground level calibrated reflectance values. Important advances were shown in the use of radiative transfer models applied either on water bodies or vegetation. Several studies highlighted the high degree of redundancy contained in high spectral resolution data.

Baret, F.↗

Rainfall and Snowfall Observations by the Airborne Dual-frequency Precipitation Radar during the Wakasa Bay Experiment

Radar data obtained through the NASA/JPL Airborne Precipitation Radar APR-2 during the Wakasa Bay Experiment in January/February 2003 were processed to obtain calibrated reflectivity measurements, rainfall/snowfall velocity measurements, classification of the surface type and detection of the boundaries of the melting layer of precipitation. In this paper the processing approach is described together with an overview of the resulting data quality and known issues.

field campaign↗

2nd Generation Airborne Precipitation Radar (APR-2)

Dual-frequency operation with Ku-band (13.4 GHz) and Ka-band (35.6 GHz). Geometry and frequencies chosen to simulate GPM radar. Measures reflectivity at co- and cross-polarizations, and Doppler. Range resolution is approx. 60 m. Horizontal resolution at surface is approx. 1 km. Reflectivity calibration is within 1.5 dB, based on 10 deg sigmaO at Ku-band and Mie scattering calculations in light rain at Ka-band. LDR measurements are OK to near -20 dB; LDR lower than this is likely contaminated by system cross-polarization isolation. Velocity is motion-corrected total Doppler, including particle fall speed. Aliasing can be seen in some places; can usually be dealiased with an algorithm. .

Ku-band (13.4 GHz)↗

The Ocean Color Instrument Performance Summary

Overview: 1. Calibration equation, GSD, IFOV, FoR, B2B registration 2. Center wavelengths, spectral sampling, OOB 3. SNR, RVS, polarization, linearity 4. Straylight/crosstalk, temperature sensitivity 5. Striping, absolute gain, Gain trending, spectral on-orbit trending (measurements during tilt) 6. SWIR band hysteresis correction, SPCA measurements

PACE↗

Target reflectance measurements for calibration of lidar atmospheric backscatter data

Wavelength and angular dependence of reflectances and depolarization in the 9-11 micron region are reported for four standard targets: flowers of sulfur, flame-sprayed aluminum, 20-grit sandblasted aluminum, and 400-grit silicon carbon sandpaper. Measurements are presented and compared using a CW CO2 grating-tunable laser in a laboratory backscatter apparatus, an integrating sphere, and a coherent pulsed TEA-CO2 lidar system operating in the 9-11 micron region. Reflectance theory related to the use of hard targets to calibrate lidar atmospheric backscatter data is discussed.

Kavaya, M. J.↗

Evaluation of NOAA-20 VIIRS reflective solar bands calibration performance using vicarious approaches

The newly launched polar-orbiting NOAA-20 satellite is the follow-on mission to the SNPP (Suomi National Polar-orbiting Partnership) satellite. Both satellites are in an afternoon orbit with a close equatorial cross time. The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor onboard NOAA-20 and SNPP. The two VIIRS sensors are within the same engineering design with nearly identical spectral ranges. Its on-board calibration components include a solar diffuser and a solar diffuser stability monitor for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view as background reference. This study evaluates calibration performance of the NOAA-20 VIIRS RSB using the first internally released L1B data product by NASA Land SIPS, which has consistent calibration coefficient look up tables (LUT) throughout the entire mission. Several independent vicarious approaches are used to examine the stability and consistence of reflectance. The first approach is based on a double difference method by comparison with SNPP VIIRS using observations from simultaneous nadir overpasses (SNO) with Aqua MODIS. The second is based on the reflectance trends from 16-day repeatable orbits obtained over the widely used Liby-4 desert site so each data point has the nearly same viewing angles relative to the site. The third approach is to use the frequent overpasses over the Dome C snow site. Results of this study provide NOAA-20 VIIRS post-launch calibration stability performance and radiometric agreement with SNPP for the first 18 months of mission.

VIIRS↗

Prelaunch absolute radiometric calibration of the reflective bands on the LANDSAT-4 protoflight Thematic Mapper

The results of the absolute radiometric calibration of the LANDSAT 4 thematic mapper, as determined during pre-launch tests with a 122 cm integrating sphere, are presented. Detailed results for the best calibration of the protoflight TM are given, as well as summaries of other tests performed on the sensor. The dynamic range of the TM is within a few per cent of that required in all bands, except bands 1 and 3. Three detectors failed to pass the minimum SNR specified for their respective bands: band 5, channel 3 (dead), band 2, and channels 2 and 4 (noisy or slow response). Estimates of the absolute calibration accuracy for the TM show that the detectors are typically calibrated to 5% absolute error for the reflective bands; 10% full-scale accuracy was specified. Ten tests performed to transfer the detector absolute calibration to the internal calibrator show a 5% range at full scale in the transfer calibration; however, in two cases band 5 showed a 10% and a 7% difference.

Barker, J. L.↗

Calibration of the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) plans to observe climate change trends over decadal time scales to determine the accuracy of climate projections. The project relies on spaceborne earth observations of SI-traceable variables sensitive to key decadal change parameters. The mission includes a reflected solar instrument retrieving at-sensor reflectance over the 320 to 2300 nm spectral range with 500-m spatial resolution and 100-km swath. Reflectance is obtained from the ratio of measurements of the earth s surface to those while viewing the sun relying on a calibration approach that retrieves reflectance with uncertainties less than 0.3%. The calibration is predicated on heritage hardware, reduction of sensor complexity, adherence to detector-based calibration standards, and an ability to simulate in the laboratory on-orbit sources in both size and brightness to provide the basis of a transfer to orbit of the laboratory calibration including a link to absolute solar irradiance measurements.

Thome, Kurtis↗

MODIS Reflective Solar Band Calibration Improvements using Pseudo-Invariant Desert Targets

To provide the best science data quality, an accurate characterization of the response versus scan angle (RVS) function is critical for the MODIS reflective solar bands (RSB) on-orbit calibration. In every MODIS operational scan, the Earth’s surface, referred to here as Earth view (EV), the space view (SV) port, and the onboard calibrators are viewed via a two-sided scan mirror. The RVS is defined as the sensor’s relative response as a function the angle of incidence (AOI) to the scan mirror. Many different approaches have been developed to derive the time-dependent RVS and its look-up table (LUT) applied to MODIS Level 1B (L1B) products since calibration Collection 4. For most MODIS RSB, the on-board calibrators can reasonably track the RVS change with time. In practice, their RVS is derived using data from on-board calibrators and the EV mirror side ratio (for mirror side 2). For Terra bands 1-4, 8-10 and Aqua bands 1-4, 8-9, an enhancement has been employed in Collections 6 and 6.1 (C6/C6.1) by using Earth scene response trending from pseudo-invariant desert sites in addition to the onboard calibrators. The current C6/C6/1 RVS algorithm is focused on fitting the EV data at each AOI over time and then deriving the relative change at different AOI. The EV response trending is currently fitted with multiple segments over time. Alternatively, the EV responses can be fit first as a function of AOI before fitting temporally in order to reduce the dependence on the stability of the desert site. These pre-treatment methods on the EV data provide improvement in the derived calibration coefficients. However, evidence of insufficient calibration is still observed in the MODIS L1B reflectance data, especially in the form of differences between the mirror sides. In this paper, we review the current methodologies that utilize the EV response trends from the pseudo-invariant Libyan desert targets to supplement the gain derived from the onboard calibrators. An improvement is then proposed and investigated such that a sliding window average (SWA) is used to pre-process the raw EV data. The SWA parameters are carefully selected using trade-off studies to accurately track the Earth scene response trending in multiple cases to overcome the reflectance differences between two mirror sides. Calibration results show improvements for both Aqua and Terra MODIS RSB L1B data products. This new adjustment has been included in the recently delivered Collection 7 LUT that will be evident in the L1B products expected to be released in late 2021.

MODIS↗

Validation of Radiometric Standards for the Laboratory Calibration of Reflected-Solar Earth Observing Satellite Instruments

Historically, the traceability of the laboratory calibration of Earth-observing satellite instruments to a primary radiometric reference scale (SI units) is the responsibility of each instrument builder. For the NASA Earth Observing System (EOS), a program has been developed using laboratory transfer radiometers, each with its own traceability to the primary radiance scale of a national metrology laboratory, to independently validate the radiances assigned to the laboratory sources of the instrument builders. The EOS Project Science Office also developed a validation program for the measurement of onboard diffuse reflecting plaques, which are also used as radiometric standards for Earth-observing satellite instruments. Summarized results of these validation campaigns, with an emphasis on the current state-of-the-art uncertainties in laboratory radiometric standards, will be presented. Future mission uncertainty requirements, and possible enhancements to the EOS validation program to ensure that those uncertainties can be met, will be presented.

Butler, James J.↗

Using solar eclipse events to validate VIIRS reflective solar band calibration at multiple radiance levels

The VIIRS instruments aboard the SNPP and NOAA-20 (N20) satellites have 14 reflective solar bands (RSB) covering a spectral range from 412 nm to 2250 nm. The radiance of each VIIRS RSB is calculated from a quadratic function of the background-subtracted digital count, 𝑑𝑛, with the quadratic coefficients determined during pre-launch testing. On orbit, calibration is maintained using observations of a sunlit solar diffuser (SD), which views the Sun every orbit through a fixed attenuation screen. The SD observations, which are at nearly the same radiance level every orbit, provide a time varying overall calibration adjustment factor, the F-factor. But there is no designed on-orbit mechanism for calibration at multiple radiance levels, so the relative strengths of the quadratic coefficients continue to be fixed at the pre-launch values. On a few rare occasions, the VIIRS instruments have passed through a partial solar eclipse during the part of the satellite orbit when the SD is illuminated by the Sun (near the South Pole). As of August 2019, the SNPP and N20 VIIRS SDs have observed five and three partial solar eclipses, respectively. While these events are rare, they offer a unique opportunity to test the RSB calibration using the SD at different radiance levels. In this paper, we compare the reduction in the measured SD signals during an eclipse to the predicted radiance reduction based on the Sun-Moon geometry and a solar radiance model. We find good agreement between the data and model for all events, indicating that the VIIRS RSB gain linearity has remained fairly stable on-orbit. The most significant deviation is for the N20 short-wave infrared bands, which had non-linearity concerns during pre-launch testing. We also investigate the SNPP results using different versions of the prelaunch quadratic gain coefficients.

solar eclipse↗

Feasibility study of the use of synchrotron radiation in the calibration of AXAF - Initial reflectivity results

The 1-percent calibration accuracy goal of the Advanced X-ray Astrophysics Facility is being approached by way of an experiment at the National Synchrotron Light Source that will demonstrate the accuracy achievable in reflectance measurements conducted on coated flat mirrors in the 50 eV-12 keV energy range. The coatings will be of commercially produced Au, Ni, and Ir, deposited either by sputtering or by e-beam deposition. Optical constants will be estimated via the reflectance vs. angle-of-incidence method.

Graessle, D. E.↗

Sensor calibration for multiple direction reflectance observations

Spectral and radiometric calibrations of a pointable airborne spectroradiometer called ASAS are discussed. A laboratory integrating hemisphere is used to characterize the radiometric respones of ASAS detectors. Radiometric responses are linear except for an initial build-up lag in response to low levels of radiance. Assuming radiometric stability in flight, raw ASAS digital counts can be transformed to absolute spectral radiance values with an uncertainty of 5.5 percent attributable to the laboratory calibration. The calibrations are being applied to radiometrically correct ASAS data acquired from multiple view directions over a tall grass prairie during the 1987 growing season.

Irons, James R.↗

Degradation of MODIS Optics and its Reflective Solar Bands Calibration

The MODerate Resolution Imaging Spectroradiometer (MODIS) has 36 spectral bands with wavelength ranging from 0.41 micron to 14.5 micron and spatial resolution between 0.25, 0.5, and 1.0 km at Nadir. Its ProtoFlight Model (PFM) on the NASA EOS Terra spacecraft has been providing global coverage of the Land, Ocean, and Atmosphere for the science community since the instrument opened its Nadir door on 24 February 2000. The MODIS optical system consists of a 2-sided paddle wheel scan mirror, a fold mirror, a primary mirror, and other aft optics. The sensor's 20 reflective solar bands from 0.41 to 2.1 micron are calibrated on-orbit by a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). In addition to SD, degradation of the MODIS optics in the reflective solar bands has been observed, including variations in degradation between the two sides of the MODIS scan mirror. During MODIS first year of on-orbit operation, the overall degradations at the shortest wavelength (0.41 micron) are about 3% for SD, and in excess of 10% for the MODIS system. In this paper, we will present our degradation analysis results and discuss their impact on the reflective solar bands' on-orbit calibration.

Xiong, X.↗

Results and Lessons from MODIS Reflective Solar Bands Calibration: Pre-launch to On-orbit

MODIS is a major instrument for the NASA EOS Terra (1aunched in December 1999) and Aqua (launched in May 2002) missions. It was designed and built to enhance and extend its heritage sensors' measurements and data records with applications covering a wide range of studies of the Earth's land, oceans, and atmosphere. MODIS has 36 spectral bands (0.41 - 14.4 micrometers) located on four focal plane assemblies (FPAs). It makes measurements at three nadir spatial resolutions: 250m (bands 1-2), 500m (bands 3-7), and lkm (bands 8-36). Because of instrument design complexity and stringent calibration requirements, extensive calibration and characterization activities were conducted pre-launch by the sensor vendor (Raytheon / Santa Barbara Remote Sensing) for both Tesa and Aqua MODIS. For the 20 reflective solar bands (RSB), these activities include measurements for the detectors noise characterization and radiometric performance, system level response versus scan-angle (RVS), polarization sensitivity, and relative spectral response (RSR). Key radiometric performance was evaluated using thermal vacuum observations. On-orbit MODIS RSB calibration is performed using a solar diffuser (SD) and solar diffuser stability monitor (SDSM) system. The SD bi-directional reflectance factor (BRF) was characterized pre-launch by the sensor vendor with reference samples traceable to NIST reflectance standards. This paper provides a summary of Terra and Aqua MODIS RSB pre-launch and on-orbit calibration and characterization activities and results with focus on the detectors' noise characterization and radiometric performance. Challenging and concerning issues and lessons learned from RSB pre-launch calibration and their impact on post launch performance are also presented. A similar summary for MODIS thermal emissive bands (TEB) is reported in a separate paper in these proceedings.

Xiong, X.↗

Assessing the Calibration Differences in the Reflective Solar Bands of Terra MODIS and Landsat-7 Enhanced Thematic Mapper Plus

Long-term data records obtained from Earth observing sensors depend not only onthe calibration accuracy of individual sensors but also on the consistency across instruments andplatforms. Hence, sensor calibration intercomparison plays a vital role for a better understandingof various science products. The Moderate Resolution Imaging Spectroradiometer (MODIS)and enhanced thematic mapper plus (ETM+) on the Terra and Landsat 7 platforms have operatedsuccessfully since their launch, collecting measurements in the reflective solar and infrared partsof the spectrum. Terra MODIS has employed a reflectance-based calibration since beginning itsmission. In the case of ETM+, a radiance-based calibration was employed until recent years,when a reflectance-based calibration was introduced. Being in the AM constellation with lessthan 30 min difference in overpass times, near-simultaneous Earth scene measurements can beeffectively used to assess the calibration differences between the spectrally matching bands ofthese two instruments. The pseudoinvariant calibration sites (PICS) in the North African desertare widely used for on-orbit calibration and validation of satellite sensors. Four PICS from thisregion have been employed to assess the multitemporal reflectance differences. Correction forbidirectional reflectance, spectral response function mismatch, and impacts of atmosphericwater-vapor have been incorporated to provide an assessment of the long-term stability ofeach spectral band and reflectance differences amongst them. Results indicate that the spectralbands of both instruments show a long-term stability to within 2% from 2000 to 2017. Thetop-of-atmosphere reflectances between the two instruments postcorrection agree to within 4%.Also included in this paper is a detailed discussion of various parameters contributing to theuncertainties of this cross-calibration. The techniques presented in this paper can be furtherextended to perform similar intercomparison between Landsat 8 Operational Land Imager, AquaMODIS, and Suomi-NPP VIIRS.

Angal, Amit↗