Search NASA⌕ Search

SEARCH · Search NASA

Results for “relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Durability Evaluation of Selected Solid Lubricating Films

An investigation was conducted to examine the coefficients of friction, wear rates, and durability of bonded molybdenum disulfide (MoS2), magnetron-sputtered MoS2, ion-plated silver, ion-plated lead, magnetron-sputtered diamondlike carbon (MS DLC), and plasma-assisted, chemical-vapor-deposited DLC (PACVD DLC) films in sliding contact with 6-mm-diameter AISI 440C stainless steel balls. Unidirectional ball-on-disk sliding friction experiments were conducted with a load of 5.9 N and a sliding velocity of 0.2 m/s at room temperature in three environments: ultrahigh vacuum (vacuum pressure, 7 x 10(exp -7) Pa), humid air (relative humidity, approx. 20 percent), and dry nitrogen (relative humidity, less than 1 percent). The main criteria for judging the performance of the solid lubricating films were coefficient of friction and wear rate, which had to be less than 0.3 and on the order of 10(exp -6) cu mm/N.m or less, respectively. The bonded MoS2 and magnetron-sputtered MoS2 films met the criteria in all three environments. The ion-plated lead and silver films met the criteria only in ultrahigh vacuum but failed in humid air and in dry nitrogen. The MS DLC and PACVD DLC films met the requirements in humid air and dry nitrogen but failed in ultrahigh vacuum.

Miyoshi, Kazuhisa↗

Cloud condensation nucleus counter by impactor sampling technique

Unlike typical CCN counters, this device counts the numbers of water droplets condensed on aerosol particles sampled on a microcover glass at various different relative humidities. The relative humidities ranged from 75 percent to a calculated value of 110 percent. A schematic of the apparatus is shown. The individual CCN can be identified in an optical micrograph and scanning electron micrograph and may be inspected for their chemical composition later.

Ohtake, T.↗

Surface Chemistry, Friction, and Wear Properties of Untreated and Laser-Annealed Surfaces of Pulsed-Laser-Deposited WS(sub 2) Coatings

An investigation was conducted to examine the surface chemistry, friction, and wear behavior of untreated and annealed tungsten disulfide (WS2) coatings in sliding contact with a 6-mm-diameter 440C stainless-steel ball. The WS2 coatings and annealing were performed using the pulsed-laser-deposition technique. All sliding friction experiments were conducted with a load of 0.98 N (100 g), an average Hertzian contact pressure of 0.44 GPa, and a constant rotating speed of 120 rpm. The sliding velocity ranged from 31 to 107 mm/s because of the range of wear track radii involved in the experiments. The experiment was performed at room temperature in three environments: ultrahigh vacuum (vacuum pressure, 7X(exp -10) Pa), dry nitrogen (relative humidity, less than 1 percent), and humid air (relative humidity, 15 to 40 percent). Analytical techniques, including scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDX), x-ray photo electron spectroscopy (XPS), surface profilometry, and Vickers hardness testing, were used to characterize the tribological surfaces of WS2 coatings. The results of the investigation indicate that the laser annealing decreased the wear of a WS2 coating in an ultrahigh vacuum. The wear rate was reduced by a factor of 30. Thus, the laser annealing increased the wear life and resistance of the WS2 coating. The annealed WS 2 coating had a low coefficient of friction (less than O.1) and a low wear rate ((10(exp -7) mm(exp 3)/N-m)) both of which are favorable in an ultrahigh vacuum.

Miyoshi, Kazuhisa↗

Ground cloud hydrogen chloride measurements from three Titan launches at the Kennedy Space Center during 1978 and 1979

Total hydrogen chloride and gaseous hydrogen chloride concentrations were measured in the exhaust cloud produced at three Titan 3 launches at the Kennedy Space Center in March 1978, December 1978, and November 1979 to determine the degree of hydrogen chloride partitioning in a solid rocket exhaust cloud between gaseous hydrogen chloride and hydrochloric acid aerosol as a function of ambient relative humidity. Moderately low relative humidity conditions were present during a daytime launch on Mar 25, 1978, and high relative humidity conditions were present during a nighttime launch on December 13, 1978. Gaseous hydrogen chloride concentrations and meteorological data, as a function of time after launch, are presented. Hydrogen chloride is present in both the gaseous and aerosol phase in the exhaust cloud. Total HCl concentrations ranged from 18 parts per million by volume (ppm) several minutes after launch down to 1 ppm after the cloud stabilization period, depending on the meteorological conditions. Gaseous HCl concentrations ranged from 2 to 3 ppm several minutes after launch to less than 1 ppm after cloud stabilization. These measured concentrations indicated significant HCl aerosol formation.

Seabacher, D. I.↗

Friction and Wear Properties of As-Deposited and Carbon Ion-Implanted Diamond Films

Recent work on the friction and wear properties of as-deposited and carbon ion-implanted diamond films was reviewed. Diamond films were produced by the microwave plasma chemical vapor deposition (CVD) technique. Diamond films with various grain sizes and surface roughnesses were implanted with carbon ions at 60 keV ion energy, resulting in a dose of 1.2 x 10(exp 17) carbon ions per cm(exp 2). Various analytical techniques, including Raman spectroscopy, proton recoil analysis, Rutherford backscattering, transmission and scanning electron microscopy, X-ray photoelectron spectroscopy, and X-ray diffraction, were utilized to characterize the diamond films. Sliding friction experiments were conducted with a polished natural diamond pin in contact with diamond films in the three environments: humid air (40% relative humidity), dry nitrogen (less than 1 percent relative humidity), and ultrahigh vacuum (10(exp -7) Pa). The CVD diamond films indeed have friction and wear properties similar to those of natural diamond in the three environments. The as-deposited, fine-grain diamond films can be effectively used as self-lubricating, wear-resistant coatings that have low coefficients of friction (0.02 to 0.04) and low wear rates (10(exp -7) to lO(exp -8) mm(exp 3) N(exp -1) m(exp -1)) in both humid air and dry nitrogen. However, they have high coefficients of friction (1.5 to 1.7) and a high wear rate (10(exp -4) mm(exp 7) N(exp -1) m(exp -1)) in ultrahigh vacuum. The carbon ion implantation produced a thin surficial layer (less than 0.1 micron thick) of amorphous, non-diamond carbon on the diamond films. In humid air and dry nitrogen, the ion-implanted, fine and coarse-grain diamond films have a low coefficient of friction (around 0.1) and a low wear rate (10(exp -7) mm(exp 3) N(exp -1) m(exp-1)). Even in ultrahigh vacuum, the presence of the non-diamond carbon layer reduced the coefficient of friction of fine-grain diamond films to 0.1 or lower and the wear rate to 10(exp -6) mm(exp 3) N(exp -1) m(exp -1). Thus, the carbon ion-implanted, fine-grain diamond films can be effectively used as wear-resistant, self-lubricating coatings not only in air and dry nitrogen, but also in ultrahigh vacuum.

Miyoshi, Kazuhisa↗

On the Choice of Variable for Atmospheric Moisture Analysis

The implications of using different control variables for the analysis of moisture observations in a global atmospheric data assimilation system are investigated. A moisture analysis based on either mixing ratio or specific humidity is prone to large extrapolation errors, due to the high variability in space and time of these parameters and to the difficulties in modeling their error covariances. Using the logarithm of specific humidity does not alleviate these problems, and has the further disadvantage that very dry background estimates cannot be effectively corrected by observations. Relative humidity is a better choice from a statistical point of view, because this field is spatially and temporally more coherent and error statistics are therefore easier to obtain. If, however, the analysis is designed to preserve relative humidity in the absence of moisture observations, then the analyzed specific humidity field depends entirely on analyzed temperature changes. If the model has a cool bias in the stratosphere this will lead to an unstable accumulation of excess moisture there. A pseudo-relative humidity can be defined by scaling the mixing ratio by the background saturation mixing ratio. A univariate pseudo-relative humidity analysis will preserve the specific humidity field in the absence of moisture observations. A pseudorelative humidity analysis is shown to be equivalent to a mixing ratio analysis with flow-dependent covariances. In the presence of multivariate (temperature-moisture) observations it produces analyzed relative humidity values that are nearly identical to those produced by a relative humidity analysis. Based on a time series analysis of radiosonde observed-minus-background differences it appears to be more justifiable to neglect specific humidity-temperature correlations (in a univariate pseudo-relative humidity analysis) than to neglect relative humidity-temperature correlations (in a univariate relative humidity analysis). A pseudo-relative humidity analysis is easily implemented in an existing moisture analysis system, by simply scaling observed-minus background moisture residuals prior to solving the analysis equation, and rescaling the analyzed increments afterward.

Dee, Dick P.↗

Measurements and Modeling of Aerosol Absorption and Single Scattering Albedo at Ambient Relative Hum

Uncertainties in the aerosol single scattering albedo have been identified to be an important source of errors in current large-scale model estimates of the direct aerosol radiative forcing of climate. A number of investigators have obtained estimates of the single scattering albedo from a variety of remote sensing and in situ measurements during aerosol field experiments. During the Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX, 1996) for example, estimates of the aerosol single scattering albedo were obtained (1) as a best-fit parameter in comparing radiative flux changes measured by airborne pyranometer to those computed from independently measured aerosol properties; (2) from estimates of the aerosol complex index of refraction derived using a combination of airborne sunphotometer, lidar backscatter and in situ size distribution measurements; and (3) from airborne measurements of aerosol scattering and absorption using nephelometers and absorption photometers. In this paper, we briefly compare the results of the latter two methods for two TARFOX case studies, since those techniques provide height-resolved information about the aerosol single scattering albedo. Estimates of the aerosol single scattering albedo from nephelometer and absorption photometer measurements require knowledge of the scattering and absorption humidification (i.e., the increase in these properties in response to an increase in ambient relative humidity), since both measurements are usually carried out at a relative humidity different from the ambient atmosphere. In principle, the scattering humidification factor can be measured, but there is currently no technique widely available to measure the absorption of an aerosol sample as a function of relative humidity. Frequently, for lack of better knowledge, the absorption humidification is assumed to be unity (meaning that there is no change in aerosol absorption due to an increase in ambient relative humidity). This assumption then enters the estimate of the single scattering albedo at ambient relative humidity. To investigate the validity of this assumption we have carried out modeling studies of the absorption humidification factor, assuming that the aerosols contain an insoluble soot core and a coating which determines its hygroscopic growth behavior. The aerosol optical properties are then computed on the basis of the shell/core particle morphology using a Mie-code for concentric shells. From basic physical principles, it is conceivable that aerosol absorption increases when an atmospheric aerosol particle collects a non-absorbing shell, since the soot core is then exposed to an increased (focused) electric field strength. Indeed, our preliminary modeling studies show that the absorption of an atmospheric aerosol particle composed of a soot core and an aqueous sulfuric acid shell may increase by a factor of 50% due to a change in ambient relative humidity from 30 to 95%. We will show how this increased absorption is a function of the initial particle size and soot mass fraction.

Redemann, J.↗

Validation of clear-sky fluxes for tropical oceans from the Earth Radiation Budget Experiment

The existence and magnitude of a systematic bias in the clear-sky longwave fluxes from the Earth Radiation Budget Experiment (ERBE) is investigated. The bias is apparently introduced because the ERBE method for scene identification does not account for large zonal gradients in longwave absorption by water vapor. The ERBE fluxes are compared to fluxes calculated with a radiative transfer model from ship radiosonde measurements. The comparison is based upon an analysis of 5 yr of coincident satellite and radiosonde observations for equatorial ocean regions. The differences between the ERBE and model fluxes are examined as functions of sea surface temperature (SST) and relative humidity. The authors use height-mean relative humidity bar-RH as an index of atmospheric moisture. The average offset between and model ERBE fluxes ranges between +2 and +6 W/sq m for SSTs above 295 K, and the gradients with respect to SST are nearly identical. However, the difference between the model and ERBE depends significantly on the tropospheric relative humidity. ERBE fluxes exceed model fluxes for bar-RH above 70%, and the maximum offset of +9 to +12 W/sq m is consistent with previous estimates. There are also indications that the clear-sky fluxes for bar-RH below 25% may be underestimated by about 10-15 W/sq m. Since extreme values of height-mean humidity are relatively infrequent, the net bias introduced in the ERBE monthly mean clear-sky fluxes is generally less than the systematic error in estimates introduced in the ERBE monthly mean clear-sky fluxes is generally less than the systematic error in estimates of the instantaneous fluxes. These findings support earlier work on the coupling between SST and the atmospheric greenhouse effect, in particular the existence of a super greenhouse effect for oceans warmer than 300 K. Recent reports of much larger systematic differences are not supported by this analysis. The results indicate that comparison of general circulation model (GCM) and ERBE clear-sky longwave fluxes will depend explicitly on atmospheric humidity.

Collins, W. D.↗

Hygroscopic Properties of Magnetic Recording Tape

Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

Cuddihy, E. F.↗

Water Vapor Measurements by Howard University Raman Lidar during the WAVES 2006 Campaign

Retrieval of water vapor mixing ratio using the Howard University Raman Lidar is presented with emphasis on three aspects: i) performance of the lidar against collocated radiosondes and Raman lidar, ii) investigation of the atmospheric state variables when poor agreement between lidar and radiosondes values occurred and iii) a comparison with satellite-based measurements. The measurements were acquired during the Water Vapor Validation Experiment Sondes/Satellites 2006 field campaign. Ensemble averaging of water vapor mixing ratio data from ten night-time comparisons with Vaisala RS92 radiosondes shows on average an agreement within 10 % up to approx. 8 km. A similar analysis of lidar-to-lidar data of over 700 profiles revealed an agreement to within 20 % over the first 7 km (10 % below 4 km). A grid analysis, defined in the temperature - relative humidity space, was developed to characterize the lidar - radiosonde agreement and quantitatively localizes regions of strong and weak correlations as a function of altitude, temperature or relative humidity. Three main regions of weak correlation emerge: i) regions of low relative humidity and low temperature, ii) moderate relative humidity at low temperatures and iii) low relative humidity at moderate temperatures. Comparison of Atmospheric InfraRed Sounder and Tropospheric Emission Sounder satellites retrievals of moisture with that of Howard University Raman Lidar showed a general agreement in the trend but the formers miss a lot of the details in atmospheric structure due to their low resolution. A relative difference of about 20 % is usually found between lidar and satellites measurements.

Adam, M.↗

Statistical Analysis of Factors Riving Surface Ozone Variability over Continental South Africa

Statistical relationships between surface ozone (O3) concentration, precursor species and meteorological conditions in continental South Africa were examined from data obtained from measurement stations in north-eastern South Africa. Three multivariate statistical methods were applied in the investigation, i.e. multiple linear regression (MLR), principal component analysis (PCA) and –regression (PCR), and generalised additive model (GAM) analysis. The daily maximum 8-h moving average O3 concentrations were considered in these statistical models (dependent variable). MLR models indicated that meteorology and precursor species concentrations are able to explain ~50% of the variability in daily maximum O3 levels. MLR analysis revealed that atmospheric carbon monoxide (CO), temperature and relative humidity were the strongest factors affecting the daily O3 variability. In summer, daily O3 variances were mostly associated with relative humidity, while winter O3 levels were mostly linked to temperature and CO. PCA indicated that CO, temperature and relative humidity were not strongly collinear. GAM also identified CO, temperature and relative humidity as the strongest factors affecting the daily variation of O3. Partial residual plots found that temperature, radiation and nitrogen oxides most likely have a non-linear relationship with O3,while the relationship with relative humidity and CO is probably linear. An inter-comparison between O3 levels modelled with the three statistical models compared to measured O3 concentrations showed that the GAM model offered a slight improvement over the MLR model. These findings emphasise the critical role of regional-scale O3 precursors coupled with meteorological conditions in daily variances of O3 levels in continental South Africa.

multiple linear regression (MLR)↗

Friction and Wear Properties of As-deposited and Carbon Ion-implanted Diamond Films

Recent work on the friction and wear properties of as-deposited and carbon ion-implanted diamond films was reviewed. Diamond films were produced by the microwave plasma chemical vapor deposition (CVD) technique. Diamond films with various grain sizes and surface roughnesses were implanted with carbon ions at 60 ke V ion energy, resulting in a dose of 1.2310(exp 17) carbon ions/cm(exp 2). Various analytical techniques, including Raman spectroscopy, proton recoil analysis, Rutherford backscattering, transmission and scanning electron microscopy, x-ray photoelectron spectroscopy, and x-ray diffraction, were utilized to characterize the diamond films. Sliding friction experiments were conducted with a polished natural diamond pin in contact with diamond films in the three environments: humid air (40 percent relative humidity), dry nitrogen (less than 1 percent relative humidity), and ultrahigh vacuum (10(exp -7) Pa). The CVD diamond films indeed have friction and were properties similar to those of natural diamond in the three environments. The as-deposited, fine-grain diamond films can be effectively used as self-lubricating, wear-resistant coatings that have low coefficients of friction (0.02 to 0.04) and low wear rates (10(exp -7) to 10(exp -8)mm(exp 3)/N-m) in both humid air and dry nitrogen. However, they have high coefficients of friction (1.5 to 1.7) and a high wear rate (10(exp -4)mm(exp 3/N-m) in ultrahigh vacuum. The carbon ion implanation produced a thin surficial layer (less than 0.1 micron thick) of amorphous, nondiamond carbon on the diamond films. In humid air and dry nitrogen, the ion-implanted, fine- and coarse-grain diamond films have a low coefficient of friction (around 0.1) and a low wear rate (10(exp -7)mm(exp 3/N-m). Even in ultrahigh vacuum, the presence of the nondiamond carbon layer reduced the coefficient of friction of fine-grain diamond films to 0.1 or lower and the wear rate to 10(exp -6)mm(exp 3)/N-m. Thus, the carbon ion-implanted, fine-grain diamond films can be effectively used as wear-resistant, self-lubricating coatings not only in air and dry nitrogen, but also in ultrahigh vacuum. The wear mechanism of diamond films is that of small fragments chipping off the surface. The size of wear particles is related to the extent of wear rates.

Miyoshi, Kazuhisa↗

Interannual Variations in Tropical Upper-Tropospheric Humidity: Understanding Tropical Convective and Dynamical Processes

Uncertainty remains as to what extent variability in mid to upper tropospheric moisture, especially over the tropics, behaves as constant relative humidity during interannual climate variations associated with ENSO. Systematic variations in HIRS 6.7 micron and MLS 205 GHz suggest that dry subtropical regions evolving during warm SST events depress relative humidity, but the interpretation of these events is still uncertain. Additional specific concerns have to do with regional signatures of convective processes: How does the origin of dry air in the eastern subtropical N. Pacific differ in ENSO warm versus cold years? The dynamics of Rossby wave forcing by convective heating, subtropical jet stream dynamics, and dynamics driven subsidence all come into play here. How variations in precipitating ice hydrometeors from tropical anvils relate to variations in UTH is also a subject of debate? Do variations in precipitating ice, cloud cover and water vapor behavior show any support for the Iris-hypothesis mechanism? Here we examine historical records of SSM/T-2 data to gain a better physical understanding of the effects of deep convective moisture sources and dynamically-induced vertical circulations on UTH. These high frequency microwave measurements (183.3 GHz) take advantage of far less sensitivity to cloud hydrometeors than the 6.7 micron data to yield a record of upper tropospheric relative humidity. Furthermore, signatures of precipitating ice from these channels facilitate comparisons to TRMM hydrometeors detected by radar. In analyzing these observations, we isolate water vapor and temperature change components that affect brightness temperatures and the inferred relative humidity. Trajectory modeling is also used to understand interannual humidity anomalies in terms of outflow fbm convective regions and history of diabatically-driven sinking which modifies relative humidity.

Robertson, Franklin R.↗

Mesoscale analysis of VAS 6.7 micron image data for several case studies

Several case studies are examined in an attempt to relate Visible infrared spin scan radiometers Atmospheric Sounder (VAS) water vapor channel radiance data to atmospheric moisture. Since the 6.7 micrometer channel detects radiation emitted by atmospheric water vapor from a rather thick layer, a scheme is developed which weighted rawinsonde observations of relative humidity in a similar manner. A comparison of the two fields (weighted relative humidity values from gridded rawinsonde observations and the VAS water vapor image) indicates that even when mesoscale data are used, the technique only presented a smooth representation of the radiance field. This weighting function is dependent on both the temperature and moisture distribution of the atmosphere. Cross sections of relative humidity from the mesoscale rawinsondes are produced which sliced the water vapor imagery in particularly interesting regions (areas of high and low blackbody temperatures). Comparisons are then made between the cross sections and the variations in the VAS radiance data along the cross section line. Bright regions in the water vapor imagery (cold blackbody temperatures) are often associated with thin layers of high relative humidity or thick layers of only moderately moist air. The reverse also applies, i.e., dark regions (warm blackbody temperatures) in the imagery corresponded well with very dry regions in the cross sections.

Jedlovec, G. J.↗

Mesoscale analysis of 6.7 micron image data from the VISSR Atmospheric Sounder (VAS) for several case studies

Several case studies are examined in an attempt to relate Visible infrared spin scan radiometers Atmospheric Sounder (VAS) water vapor channel radiance data to atmospheric moisture. Since the 6.7 micrometer channel detects radiation emitted by atmospheric water vapor from a rather thick layer, a scheme is developed which weighted rawinsonde observations of relative humidity in a similar manner. A comparison of the two fields (weighted relative humidity values from gridded rawinsonde observations and the VAS water vapor image) indicates that even when mesoscale data are used, the technique only presented a smooth representation of the radiance field. This weighting function is dependent on both the temperature and moisture distribution of the atmosphere. Cross sections of relative humidity from the mesoscale rawinsondes are produced which sliced the water vapor imagery in particularly interesting regions (areas of high and low blackbody temperatures). Comparisons are then made between the cross sections and the variations in the VAS radiance data along the cross section line. Bright regions in the water vapor imagery (cold blackbody temperatures) are often associated with thin layers of high relative humidity or thick layers of only moderately moist air. The reverse also applies, i.e., dark regions (warm blackbody temperatures) in the imagery corresponded well with very dry regions in the cross sections.

Jedlovec, G. J.↗

Experimental study of cluster formation in binary mixture of H2O and H2SO4 vapors in the presence of an ionizing radiation source

Molecular clusters formed in pure nitrogen containing H2O and H2SO4 vapors and exposed to a 3 mCi Ni63 beta source were studied in the mass range 50 to 780 amu using a quadrupole mass spectrometer. Measurements were made under several combinations of relative humidity and relative acidity ranging from 0.7 to 7.5 percent and 0.00047 to 0.06333 percent, respectively. The number of H2SO4 molecules in the clusters observed ranged from 1 to 7 whereas the number of H2O molecules ranged from 1 to 16. The experimental cluster spectra differ considerably from those calculated using the classical nucleation theory. First order calculations using modified surface tension values and including the effects of multipole moments of the nucleating molecules indicate that these effects may be enough to explain the difference between the measured and the calculated spectra.

Singh, J. J.↗

Predicting electrochemical breakdown in terrestrial photovoltaic modules

Electrochemical corrosion of PV cells can cause a cell-to-frame short circuit with two undesirable resuits: (1) catastrophic loss of source-circuit power; and (2) high field maintenance (module replacement) costs. Parameter dependencies are determined and encapsulated two-cell coupons are exposed to a range of voltage differences, temperatures, and relative humidities. Material relative performance is assessed. Nine different metallization-encapsulation combinations are tested.

Mon, G. R.↗

Distribution and Sources of Tropospheric Aerosols Over the Western North Atlantic During ACTIVATE (February-March 2020)

The Aerosol Cloud meTeorology Interactions oVer the western ATlantic Experiment (ACTIVATE) is a five-year (2019-2023) NASA Earth-Venture Suborbital-3 (EVS-3) mission to robustly characterize aerosol-cloud-meteorology interactions during February-June, with a focus on marine boundary layer clouds. This characterization requires understanding of aerosol composition, distribution, transport pathways, and sources. Here we use the GEOS-Chem chemical transport model driven by the MERRA-2 reanalysis to simulate tropospheric carbon monoxide (CO) and aerosols over the western North Atlantic Ocean (WNAO) during the first field deployment of ACTIVATE (February-March 2020). CO is used as a tracer to diagnose transport pathways for continental pollution outflow to the WNAO. The aerosol simulation represents all major aerosols including sulfate-nitrate-ammonium (SNA), mineral dust, sea salt, black and organic carbon aerosols. Model-simulated mixing ratios of SNA and organic carbon are compared with aircraft observations. We show that intensive aerosol mass measurements in the lower troposphere over the North American outflow region during ACTIVATE provide strong constraints on model aerosol wet scavenging. Comparisons of model aerosol extinctions with the airborne High Spectral Resolution Lidar-2 (HSRL-2) measurements indicate that the model generally captures continental outflow of aerosols and enhanced extinctions associated with sea salt. Simulated aerosol optical depths (AODs) and extinction vertical profiles are also compared with satellite retrievals from MODIS/Aqua and CALIOP/CALIPSO, respectively. CALIOP sometimes observes enhanced aerosol extinction at altitudes between ~1.5km and ~2.0km south of 32°N. The model reproduces this enhancement and attributes it to coarse-mode sea salt associated with high relative humidity. The relative contributions of continental and oceanic sources to the aerosol loading, AOD, and their distributions over the study domain will also be discussed.

aerosols↗