Search NASA⌕ Search

SEARCH · Search NASA

Results for “relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fuel cell system

A fuel cell system comprising: a fuel cell, a fuel gas supplier configured to supply fuel gas to an anode of the fuel cell, an oxidant gas supplier configured to supply oxidant gas to a cathode of the fuel cell, a humidity adjuster configured to adjust a relative humidity of the fuel gas and a relative humidity of the oxidant gas, and a controller, wherein the controller detects the relative humidity of the fuel gas at an anode inlet of the fuel cell, and the controller detects the relative humidity of the oxidant gas at a cathode outlet of the fuel cell, and wherein, based on detection results, the controller controls the humidity adjuster so that the relative humidity of the fuel gas at the anode inlet is higher than the relative humidity of the oxidant gas at the cathode outlet.

Ando, Masaki↗

Meteorological, reference evapotranspiration and estimated transpiration data, July 2020-Dec 2021, Slate River Floodplain, Crested Butte, Colorado

This data package includes a time series of meteorological data (air temperature, relative humidity, barometric pressure, precipitation, wind speed, soil heat flux, incoming shortwave radiation, incoming longwave radiation, outgoing shortwave radiation and outgoing longwave radiation) from the Slate River floodplain outside Crested Butte, Colorado, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The package also includes reference evapotranspiration calculated via the Penman-Monteith equation and an estimate of willow (Salix spp.) evapotranspiration using the method of Irmak et al., J. Hydrology, 2013. Due to two malfunctioning sensors (incoming shortwave radiation from Oct 2020-May 2021 and incoming longwave radiation from May 2021-March 2022), observed net radiation and calculated evapotranspiration are only included from July-October 2020. However, users may be able to extend calculated evapotranspiration using estimates of these two parameters from other sources. Both sensors have been replaced and data beyond 2021 be uploaded to this repository when it is available.Within the data package, "FLMD.csv" describes file-level metadata and "dd.csv" defines column headers and universal terms across the dataset. The data package includes 3 "*data.csv" files, two for meteorological data for 2020 and 2021 and one for reference evapotranspiration and transpiration data from 2020 ("SLT_OBJ2_PenmanMonteith_2020_data.csv"). Each "*data.csv" file of meteorological data has a corresponding "*_InstallationMethods.csv" file that describes the location, sensor model, sensor serial number and other metadata corresponding to each measured parameter. We also include a Jupyter notebook ("PenmanMonteithET_Calculations.ipynb") that details the assumptions and equations used to calculate daily and hourly reference evapotranspiration and daily willow transpiration from raw meteorological data.

54 ENVIRONMENTAL SCIENCES↗

Weather data at The Morton Arboretum 2017-2023

We have been monitoring long-term weather patterns using two weather stations at The Morton Arboretum to link environmental conditions to tree growth and other tree responses. This data package contains weather data at The Morton Arboretum from 2017-08-23 to 2023-12-31; data is located in the "MortonWeatherData2017_2023.csv" file. The two weather stations are located on each side of The Arboretum (e.g., the Nursery station on the East side and the Ware Field station on the West side; the two weather stations are 3.23 km apart and coordinates are included in the "Location_metadata.csv" file). Measured variables include rain accumulation, air temperature, relative humidity, three soil moisture/temperature measurements at various depths (10, 30, and 50 cm for the Nursery weather station, and 10, 25, and 50 cm for the Ware Field), solar radiation, saturation vapor pressure, and vapor pressure deficit.

54 ENVIRONMENTAL SCIENCES↗

Meteorological Conditions and Atmospheric Components Concentration in Urban Sites in Knoxville, USA. 2024

This dataset, which contains five csv files, reports several meteorological conditions such as temperature, wind speed, solar radiation, and net radiation measured in Cumberland Estates Park (CEP) and Socially Equal Energy Efficient Development (SEEED) sites in Knoxville, Tennessee, USA. Also, hourly concentration of particulate matter (PM) with different aerodynamic diameter and inorganic gases such as ozone and nitrogen dioxide measured in the two are included in this dataset. The concentrations of PM and inorganic gases were monitored using the MODULAIR, a low-cost sensor equipped with a solar power module. The measurement of the concentration of biogenic and anthropogenic volatile organic compounds (VOCs) of the two sites was determined using a High-Resolution Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-ToF-MS). The VOCs were collected using miniature canister (400 mL) equipped with female RAVEqc valve to 1/4” male compression fitting and an integrated passive air sampling kit. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

54 ENVIRONMENTAL SCIENCES↗

Meteorological Variables and Energy Fluxes at the Pumphouse Site, Crested Butte, CO 2017-2019

This data contains output from the pumphouse eddy covariance tower that includes shortwave radiation, longwave radiation, net radiation, air temperature, relative humidity, as well as sensible, latent, and ground heat fluxes. Also included is calculated evapotranspiration from the latent heat flux and the latent heat of vaporization. All data are on a daily timestep and displayed in Mountain Time. The data has been processed, and Quality Assurance / Quality Control (QA/QC) was done, but any daily gaps in the data have not been filled in. This research was funded by the Department of Energy and performed as part of the Watershed Function Scientific Focus Area. This research aimed to constrain evapotranspiration in a high-elevation catchment.The dataset includes one comma-separated values (CSV) data file (EddyCovariance_MeteorlogicalVariables_CrestedButtePumphouse.csv). Additionally, three metadata CSV files are included: (1) location metadata file (locations.csv), which contains location metadata and coordinates; (2) a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; and (3) a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Low Cost All-in-One Weather Station AMB-001 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an API key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-001), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Low Cost All-in-One Weather Station AMB-004 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an Application Programming Interface (API) key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-004), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

EARTH SCIENCE > ATMOSPHERE > AEROSOLS > PARTICULAT↗

Radiolytic Gas Production from Aluminum Coupons (Alloy 1100 and 6061) in Helium Environments—Assessing the Extended Storage of Aluminum Clad Spent Nuclear Fuel

Corrosion of aluminium alloy clad nuclear fuel, during reactor operation and under subsequent wet storage conditions, promotes the formation of aluminium hydroxide and oxyhydroxide layers. These hydrated mineral phases and the chemisorbed and physisorbed waters on their surfaces are susceptible to radiation-induced processes that yield molecular hydrogen gas (H 2 ), which has the potential to complicate the long-term storage and disposal of aluminium clad nuclear fuel through flammable and explosive gas mixture formation, alloy embrittlement, and pressurization. Here, we present a systematic study of the radiolytic formation of H 2 from aluminium alloy 1100 (AA1100) and 6061 (AA6061) coupons in “dry” (~0% relative humidity) and “wet” (50% relative humidity) helium environments. Cobalt-60 gamma irradiation of both aluminium alloy types promoted the formation of H 2 , which increased linearly up to ~2 MGy, and afforded G-values of 1.1 ± 0.1 and 2.9 ± 0.1 for “dry” and “wet” AA1100, and 2.7 ± 0.1 and 1.7 ± 0.1 for “dry” and “wet” AA6061. The negative correlation of H 2 production with relative humidity for AA6061 is in stark contrast to AA1100 and is attributed to differences in the extent of corrosion and varying amounts of adsorbed water in the two alloys, as characterized using optical profilometry, scanning electron microscopy, Raman spectroscopy, and X-ray diffraction techniques.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Influences of an entrainment–mixing parameterization on numerical simulations of cumulus and stratocumulus clouds

Abstract. Different entrainment–mixing processes can occur in clouds; however, a homogeneous mixing mechanism is often implicitly assumed in most commonly used microphysics schemes. Here, we first present a new entrainment–mixing parameterization that uses the grid mean relative humidity without requiring the relative humidity of the entrained air. Then, the parameterization is implemented in a microphysics scheme in a large eddy simulation model, and sensitivity experiments are conducted to compare the new parameterization with the default homogeneous entrainment–mixing parameterization. The results indicate that the new entrainment–mixing parameterization has a larger impact on the number concentration, volume mean radius, and cloud optical depth in the stratocumulus case than in the cumulus case. This is because inhomogeneous and homogeneous mixing mechanisms dominate in the stratocumulus and cumulus cases, respectively, which is mainly due to the larger turbulence dissipation rate in the cumulus case. Because stratocumulus clouds break up during the dissipation stage to form cumulus clouds, the effects of this new entrainment–mixing parameterization during the stratocumulus dissipation stage are between those during the stratocumulus mature stage and the cumulus case. A large aerosol concentration can enhance the effects of this new entrainment–mixing parameterization by decreasing the cloud droplet size and evaporation timescale. The results of this new entrainment–mixing parameterization with grid mean relative humidity are validated by the use of a different entrainment–mixing parameterization that uses parameterized entrained air properties. This study sheds new light on the improvement of entrainment–mixing parameterizations in models.

54 ENVIRONMENTAL SCIENCES↗

Review and Summary of Corrosion Behavior for Aluminum-Clad Spent Nuclear Fuel in Dry Storage

A description of the corrosion behavior of aluminum alloys used for cladding on aluminum-based, aluminum-clad nuclear fuel used in research reactors under potential dry storage conditions has been compiled. An evaluation is made of potential additional corrosion with water postulated to not be removed during drying. The relative humidity (RH) produced by typical dryness criteria for industrial spent nuclear fuel drying is expected to be low, particularly at high temperatures (17% RH at 20°C and lower at higher temperatures). Existing corrosion data suggests that negligible vapor-phase corrosion of aluminum is expected at such low humidity, even for nominally bare aluminum surfaces. That is, the predicted relative humidity from free water (e.g., 17% RH) is below the “critical” relative humidity (~40% RH at room temperature), below which no significant corrosion is observed for bare aluminum. Furthermore, reported room-temperature corrosion rates are very low even under saturated (100% RH) water vapor. Existing results showing significant vapor-phase corrosion corresponded specifically to conditions of high temper ed with high relative humidity. A relatively large reservoir of (chemically bound) water exists in the aluminum (oxy)hydroxide films on the SNF cladding surface. The estimated total could saturate the gas even at relatively high temperature if fully released; however, its release as molecular water is expected to only be plausible if the temperature during storage exceeds both the drying temperature and the threshold for thermal decomposition of the trihydroxides (~220°C). Therefore, the combination of high temperature and high relative humidity that could drive significant corrosion is considered implausible during sealed dry storage following an appropriate drying process, to include >220°C drying for canisters that may approach or exceed this temperature during storage. Vapor-phase testing of aluminum samples with an adherent (oxy)hydroxide layer, prepared in liquid water to resemble those on actual aluminum-clad spent nuclear fuel (ASNF), did not observe evidence of additional corrosion even at combined high-temperature (up to 180°C) and high-humidity (up to 100% RH) conditions. Instead, small net mass losses were observed for most specimens and attributed to dehydration of the samples, which had been air-dried only prior to testing. ASNF being moved to dry storage is expected to have an existing (oxy)hydroxide film, suggesting that the cladding will be less prone to additional corrosion than bare aluminum metal. If significant corrosion did occur during sealed storage, the overall extent and impact is expected to be small. Corrosion post-closure of a canister would not alter the total amount of hydrogen in the canister, so it would have no effect on the maximum H 2 release already assessed in existing bounding calculations. In addition, the total amount of water in a 25-µm dense bayerite film would consume a only ~8 µm additional aluminum metal on average, if fully consumed by oxidizing aluminum metal to Al 2 O 3 . These conclusions are consistent with ASNF-in-canister simulations to date, which included a reaction pathway for corrosion using kinetics from previous literature and believed to be conservative and predicted very low rates of corrosion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Probing the hydrolytic degradation of UF 4 in humid air

This manuscript describes the chemical transformations that occur during hydrolysis of uranium tetrafluoride (UF 4 ) due to its storage in humid air (85% and 50% relative humidity) at ambient temperatures. This hydrolysis was previously reported to proceed slowly or not at all (depending on the percent relative humidity); however, previous reports relied primarily on X-ray diffraction methods to probe uranium speciation. Here, we employ a battery of physiochemical probing techniques to explore potential hydrolysis, including Raman spectroscopy, powder X-ray diffraction, 19 F nuclear magnetic resonance spectroscopy, scanning electron microscopy, and focused ion beam microscopy with energy-dispersive X-ray spectroscopy. Of these, only Raman spectroscopy proved to be particularly useful at observing chemical changes to UF 4 . It was found that anhydrous UF 4 slightly oxidizes over the course of thirteen days to Schoepite-like uranium complexes and possibly UO 3 . In contrast, UF 4 exposed to 50% relative humidity slightly decomposes into UO 2 F 2 , Schoepite-like uranium complexes, and possibly a high order uranium oxide that eluded chemical assignment (U x O y ). Despite the rich chemical speciation observed in our Raman spectroscopy measurements, X-ray diffraction and 19 F NMR measurements on the same material showed no changes. Microscopy measurements suggest that the observed reactions between UF 4 and water occur primarily on the surface of UF 4 particulates via a method that is visually similar to surface corrosion of metals. Therefore, we postulate that NMR spectroscopy and X-ray diffraction, which are well-suited for bulk analysis, are less suited than Raman spectroscopy to observe the surface-based reactions that occur to UF 4 when exposed to humid air. Considering the importance of UF 4 in the production of nuclear fuel and weapons, the results presented herein are widely applicable to numerous nuclear science fields where uranium detection and speciation in humid environments is of value, including nuclear nonproliferation and nuclear forensics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CROCUS Weather Data at Northeastern Illinois University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements.Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

54 ENVIRONMENTAL SCIENCES↗

Back Trajectories during SAIL

This data set contains air mass back trajectories generated during the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign using the Hybrid Single-Particle Lagrangian Integrated Trajectory model (HYSPLIT, Stein et al. 2015, Rolph et al. 2017). For each hour from January 1, 2021 to June 30, 2023, a 96-hour back trajectory was initiated at the SAIL sampling site, starting 100 m above ground level. The calculations used the GDAS meteorological data set with model vertical velocity. The files within this dataset show location and meteorological parameters of the back trajectory analysis. There are 21 columns within each data file. The first 2 columns pertain to back trajectory parameters: the trajectory number (which is always 1) and the meteorological grid number. The next 9 columns pertain to spatiotemporal information: the year, month, day, hour (0-23), and minute of the trajectory, the previous time of the trajectory (in negative hours), and the airmass location (latitude, longitude, and height in m AGL). The rest of the parameters within each file pertains to surface and meteorological characteristics of the airmass: pressure (in hPa), potential temperature (in K), temperature (in K), precipitation rate (in mm/hr), mixing depth (in m), relative humidity (in % relative to liquid water), specific humidity (in g/kg), H2O mixing ratio (in g/kg), underlying terrain height (in meters above sea level), and incoming radiation (in W/m^2).

back trajectory↗

EPCAPE-PT-LANL Measurements: Humidified Cavity Attenuated Phase Shift Spectroscopy

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Humidified Cavity Attenuated Phase Shift Particulate Matter Single Scattering Albedo (H-CAPS-PMSSA, Aerodyne Inc) Data Notes: The scattering truncation correction was not applied to Bsca. The Bext needs no correction. Files: data_10sec_CAPS.csv, data_10min_CAPS.csv Header: - Bext_wet_CAPS_450nm[1/Mm]: Wet aerosol extinction coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Bsca_wet_CAPS_450nm[1/Mm]: Wet aerosol scattering coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Temp_wet_CAPS[K]: Temperature inside the wet CAPS measurement chamber, in Kelvin. - Bext_dry_CAPS_450nm[1/Mm]: Dry aerosol extinction coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Bsca_dry_CAPS_450nm[1/Mm]: Dry aerosol scattering coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Temp_dry_CAPS[K]: Temperature inside the dry CAPS measurement chamber, in Kelvin. - Wet_RH_preCAPS[%]: Relative humidity before entering the wet CAPS, in percent. - Wet_RH_postCAPS[%]: Relative humidity after exiting the wet CAPS, in percent. - Humidifier_RH_CAPS[%]: Relative humidity inside the humidifier used with the CAPS, in percent. - dualCAPS_inlet_RH[%]: Relative humidity at the inlet of the dual (wet/dry) CAPS setup, in percent. - Wet_Temp_preCAPS[C]: Temperature before entering the wet CAPS, in degrees Celsius. - Wet_Temp_postCAPS[C]: Temperature after exiting the wet CAPS, in degrees Celsius. - Humidifier_Temp[C]: Temperature inside the humidifier used with the CAPS, in degrees Celsius. - dualCAPS_inlet_Temp[C]: Temperature at the inlet of the dual (wet/dry) CAPS setup, in degrees Celsius. - Zero_dry_CAPS: 1 is a calibration check for the dry CAPS to ensure zero reading under filter air conditions. - Zero_wet_CAPS: 1 is a calibration check for the wet CAPS to ensure zero reading under filter air conditions. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

The effect of barrier films and exposure on the aging of vacuum insulation panels with fumed silica cores

Vacuum insulation panels have very low thermal conductivities compared to conventional insulation materials. The reduction of the core pressure significantly lowers gas phase conduction and overall thermal conductivity. As a consequence, increases in gas pressure can significantly increase thermal conductivity of the VIP. In addition, the thermal conductivity of the core is sensitive to moisture content. For vacuum insulation panels with fumed silica cores, work shows that the measured thermal conductivity increases by 0.5 x 10-3 W/mK per mass percent increase in water content [1]. This is significant since the thermal conductivity of vacuum insulation panels with fumed silica cores is in the range of 0.004 W/mK. This work investigates the long-term behavior of vacuum insulation panels comprised of fumed silica cores with polymer (ethylene vinyl alcohol) and metalized (aluminized) barrier films exposed to different exposure conditions: ambient conditions; exterior conditions in a mixed humid climate; and 24oC and 80 percent relative humidity. Results show that the increase in thermal conductivity is more pronounced for vacuum insulation panels made using polymer barrier films compared to the same panel protected by a metalized film. The increase is more pronounced when exposed to high relative humidity, 80 percent. After almost two years exposure, the decrease in thermal conductivity for vacuum insulation panels protected by a metalized barrier films are between 4 and 11 percent depending on exposure condition. The smallest decrease is for ambient conditions where the largest decrease is for exposure to 80 percent relative humidity. Similar behavior was observed for panels protected using polymer films, except the decrease in thermal conductivity was significantly higher, between approximately 20 and 60 percent, in the same order as for panels protected by metalized films. Measurements are ongoing with an attempt to develop a better relationship between these types of tests and vacuum insulation panel service life.

Aldykiewicz Jr, Antonio↗

A Large Ensemble Global Dataset for Climate Impact Assessments

We present a self-consistent, large ensemble, high-resolution global dataset of long-term future climate, which accounts for the uncertainty in climate system response to anthropogenic emissions of greenhouse gases and in geographical patterns of climate change. The dataset is developed by applying an integrated spatial disaggregation (SD) - bias-correction (BC) method to climate projections from the MIT Integrated Global System Model (IGSM). Four emission scenarios are considered that represent energy and environmental policies and commitments of potential future pathways, namely, Reference, Paris Forever, Paris 2 °C and Paris 1.5 °C. The dataset contains nine key meteorological variables on a monthly scale from 2021 to 2100 at a spatial resolution of 0.5°x 0.5°, including precipitation, air temperature (mean, minimum and maximum), near-surface wind speed, shortwave and longwave radiation, specific humidity, and relative humidity. We demonstrate the dataset’s ability to represent climate-change responses across various regions of the globe. This dataset can be used to support regional-scale climate-related impact assessments of risk across different applications that include hydropower, water resources, ecosystem, agriculture, and sustainable development.

54 ENVIRONMENTAL SCIENCES↗

Unconventional desalination: The use of cyclone separators in HDH desalination to achieve zero liquid discharge

Research in water desalination technologies is constantly growing to meet global demands for freshwater. Though acting to meet these demands, the rapid growth and spread of desalination technologies poses environmental issues due to the increasing brine concentrates that are ultimately discharged back to nature. This article presents a cyclone separator to transform a humidification-dehumidification (HDH) cycle to a dual-product cycle to produce freshwater and solid salt crystals for highly saline streams. A desalination cycle equipped with a cyclone separator is used to treat water with 3.5%–81% salinity. The separation efficiency is well above 99% and can produce potable water from hyper saline feed in a once-through process. Further, the cyclone separator performance was tested under different conditions including humidity ratios, relative humidities, and feed stream's salinities. The cyclone separator is self-cleaning and overcomes salt scaling. This behavior is a direct function of the walls' temperature and the carrier air dew point. Self-cleaning capability allows the cyclone separator to treat feed water of extreme salinities (up to 810,000ppm) down to freshwater salinity with zero liquid discharge. The cyclone separator was utilized in a novel HDH desalination technology to treat different salinities. The product was freshwater of salinity <500ppm.

42 ENGINEERING↗

Confocal Raman Microscopy as an In Situ Probe of Volume Change in Hydration-Sensitive Polymer Membranes

An approach is described for measuring hydration-induced volume change within ion conductive polymer membranes and thin films by adapting the technique of confocal Raman microscopy. With careful consideration of factors that affect excitation and scattering within the confocal probe volume region, material swelling and deswelling were estimated from the intensities of polymer matrix spectral features. A high numerical aperture oil-immersion objective was used to achieve tight focusing within samples and the efficient collection of Raman scattered light. The approach is demonstrated for a fluorinated cation-exchange ionomer (Nafion) and the hydrocarbon anion-exchange ionomer Sustainion. Samples were monitored while under a nitrogen atmosphere that was cycled between dry and humid (∼50% relative humidity, RH) states. The volume changes estimated from the Raman spectra were in close agreement with those derived from conventional measurements. The reported work advances understanding needed to adapt confocal Raman microscopy for quantitative in situ and operando studies of ionomers within electrochemical devices, such as polymer electrolyte membrane fuel cells and electrolyzers, and lays a foundation for broader applications in the study of hydration-induced polymer swelling and the associated molecular level water and polymer framework structural changes.

Absorption↗