Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Socially optimal replacement of conventional with electric vehicles for the US household fleet

In this study, a framework is proposed for minimizing the societal cost of replacing gas-powered household passenger cars with battery electric ones (BEVs). The societal cost consists of operational costs of heterogeneous driving patterns' cars, the government investments for charging deployment, and monetized environmental externalities. The optimization framework determines the timeframe needed for conventional vehicles to be replaced with BEVs. It also determines the BEVs driving range during the planning timeframe, as well as the density of public chargers deployed on a linear transportation network over time. We leverage datasets that represent U.S. household driving patterns, as well as the automobile and the energy markets, to apply the model. Results indicate that it takes 8 years for 80% of our conventional vehicle sample to be replaced with electric vehicles, under the base case scenario. The socially optimal all-electric driving range is 204 miles, with chargers placed every 172 miles on a linear corridor. All of the public chargers should be deployed at the beginning of the planning horizon to achieve greater savings over the years. Sensitivity analysis reveals that the timeframe for the socially optimal conversion of 80% of the sample varies from 6 to 12 years. The optimal decision variables are sensitive to battery pack and vehicle body cost, gasoline cost, the discount rate, and conventional vehicles' fuel economy. In conclusion, faster conventional vehicle replacement is achieved when the gasoline cost increases, electricity cost decreases, and battery packs become cheaper over the years.

25 ENERGY STORAGE↗

Solid-State Thyratron Replacement. Final Report

Under this SBIR, DTI developed a solid-state switch as an alternative to legacy thyratron equipment. Our Phase II objective was to make a solid-state thyratron replacement that would provide equivalent or better performance, much higher reliability (at least a 20 year lifetime, compared to a thyratron’s two-year lifetime) and would sell for ~3x the cost of a thyratron, or less than $40k. We were successful in building a solid-state switch which could reliably function as a thyratron replacement. The unit was designed to directly replace the thyratrons currently being used at SLAC’s Linac Coherent Light Source (LCLS), and was built in a tank that was small enough to fit into the existing thyratron cabinet, providing a true form-fit-function replacement path. We tested the switch at the full operating specifications: 48 kV, 6.3 kA, and 1 µs risetime. We also demonstrated a peak-to-peak pulse jitter of 1.5 ns, which is five times shorter than is typical for thyratrons. This lower jitter would improve the performance of the LCLS beam. The predicted reliability is more than 80 years, which is 40 times greater than a thyratron.

47 OTHER INSTRUMENTATION↗

Synchronization of dissolution and precipitation fronts during infiltration‐driven replacement in porous rocks

Abstract Coupled dissolution‐precipitation reactions, where two minerals share a common ion, occur frequently in geological replacement; the reactions are driven by an inflow of precipitating secondary ions and an outflow of dissolved primary ions. Although crystallization pressure is frequently invoked to explain volume‐preserving replacement, it cannot be operative if the chemical reactions lead to a loss of mineral volume; here the host rock that should confine the precipitating mineral is dissolving faster than the grains are growing. In this paper we propose two chemical mechanisms by which a rapid dissolution front and a slower precipitation front can be synchronized, and volume‐for‐volume replacement preserved. We analyze these mechanisms within the framework of reactive transport theory and show that morphological features observed in calcite replacement can be correlated with predictions of the models.

Kondratiuk, Paweł↗

In Tube Condensation Heat Transfer and Pressure Drop for R454B and R32—Potential Replacements for R410A

The heating, ventilation and air conditioning (HVAC) industry in the United States seeks near-term alternative refrigerants to replace R-410A in unitary equipment. Two potential replacement refrigerants are R-454B and R-32. It is of interest to investigate the capability and accuracy of existing heat exchanger design methods when applied to these replacement refrigerants. To that end, this work presents empirical condensation quasi-local heat transfer coefficient and pressure drop data for R-454B and R-32. These data were obtained in a $\frac{3}{8}$ in. (9.52 mm) outside diameter (OD) smooth copper tube with a wall thickness of 0.032 in. (0.81 mm). The experimental variables and their ranges included refrigerant absolute pressure ( 1960 ≤ P a b s ≤ 3196 kPa), condensation temperature ( 35 ≤ T c o n d ≤ 50 °C), mass flux ( 100 ≤ G ≤ 200 kg m -2 s -1 ), vapor quality ( 0 ≤ x ≤ 1 ), and heat flux ( 32.9 ≤ q ″ ≤ 62.97 kW m -2 ). It was found that the heat transfer correlation developed by Cavallini et al. Cavallini et al. (2006) predicted the experimental condensation heat transfer data, for both R-454B and R-32, with the greatest accuracy. Using the Cavallini et al. correlation, it was found that the mean absolute percentage error (MAPE) was 10.5% and 15.1% for R-454B and R-32, respectively. Additionally, the pressure drop correlation developed by Friedel Friedel (1979) predicted the experimentally determined pressure gradient with a MAPE of 7.7% and 5.5% for R-454B and R-32, respectively. These results will assist the practicing thermal engineer to choose the most appropriate design correlation for these near-term replacement refrigerants.

42 ENGINEERING↗

Reaction-Induced Fracturing of Porous Carbonate Rocks during Volume-Increasing Replacement by Witherite

Volume-increasing replacement reactions can lead either to fracturing of the parent phase or to the formation of cohesive layers that passivate further reaction, but the factors that drive one outcome or the other are not understood. In this experimental study, we investigated the volume-increasing replacement of carbonate rocks (consisting of CaCO 3 and CaMg(CO 3 ) 2 ) of different porosity by witherite (BaCO 3 ). Samples were characterized using scanning electron microscopy, Raman spectroscopy, small-angle neutron/X-ray scattering, X-ray tomography, and scanning transmission electron microscopy. We observed the formation of a witherite reaction layer and witherite formation within pores and along grain boundaries. Despite this being a volume-increasing replacement reaction, newly formed witherite was porous, potentially allowing further replacement. Filled fractures were observed in the low-porosity carbonates, whereas witherite formed within pores in high-porosity carbonates. We conclude that fracturing of the parent phase versus passivation is contingent on the initial microstructure of the parent with an optimal degree of porosity required for fracturing.

Calcite↗

Complete replacement of Arabidopsis oil-producing enzymes with heterologous diacylglycerol acyltransferases

Acyl-CoA:diacylglycerol acyltransferase 1 (DGAT1) and phospholipid:diacylglycerol acyltransferase 1 (PDAT1) share responsibility for triacylglycerol (TAG) biosynthesis, and their selectivities control TAG fatty acid (FA) compositions. For rational metabolic engineering of seed oils, replacing endogenous TAG biosynthesis with exogenous enzymes containing different substrate FA selectivities is desirable; however, the dgat1-1/pdat1-2 double mutant is pollen lethal. Here, we evaluated the ability of 3 DGAT1s, from phylogenetically diverse plants with distinct TAG assembly processes, to completely replace endogenous TAG biosynthesis in Arabidopsis ( Arabidopsis thaliana ). We transformed dgat1-1 mutant plants with expression constructs for DGAT1 s from Camelina sativa , Physaria fendleri , and castor ( Ricinus communis ). Transgene expression was properly “contextualized” by using a previously determined minimum necessary expression unit containing the promoter/5′ UTR and first intron of native AtDGAT1 ; both of these DNA elements are essential for pollen expression. Next, we crossed homozygous lines with a DGAT1/DGAT1/PDAT1/pdat1-2 parent. C. sativa and P. fendleri DGAT1s restored the FA compositions and transcriptional differences of dgat1-1 to near wild-type and rescued the dgat1-1/pdat1-2 pollen lethality. R. communis DGAT1 was active in dgat1-1 seeds but produced unique oil profiles and alterations in the expression of lipid metabolic genes; it also failed to rescue dgat1-1/pdat1-2 lethality. This study confirms that the promoter and first intron of AtDGAT1 can modulate the expression of foreign DGAT1 genes to fit the correct spatiotemporal profile necessary for completely replacing endogenous TAG biosynthesis. Furthermore, it demonstrates an additional layer of unexpected enzyme incompatibility between oilseed lineages, which may complicate bioengineering approaches that seek to replace essential genes with orthologs.

McGuire, Sean T. [Washington State Univ., Pullman,↗

Type II dehydroquinase: molecular replacement with many copies

The type II dehydroquinase enzyme is a symmetrical dodecameric protein which crystallizes in either high-symmetry cubic space groups or low-symmetry crystal systems with multiple copies in the asymmetric unit. Both systems have provided challenging examples for molecular replacement; for example, a triclinic crystal form has 16 dodecamers (192 monomers) in the unit cell. Three difficult examples are discussed and two are used as test cases to compare the performance of four commonly used molecular-replacement packages. Type II dehydroquinase is a small (150-amino-acid) protein which in solution packs together to form a dodecamer with 23 cubic symmetry. In crystals of this protein the symmetry of the biological unit can be coincident with the crystallographic symmetry, giving rise to cubic crystal forms with a single monomer in the asymmetric unit. In crystals where this is not the case, multiple copies of the monomer are present, giving rise to significant and often confusing noncrystallographic symmetry in low-symmetry crystal systems. These different crystal forms pose a variety of challenges for solution by molecular replacement. Three examples of structure solutions, including a highly unusual triclinic crystal form with 16 dodecamers (192 monomers) in the unit cell, are described. Four commonly used molecular-replacement packages are assessed against two of these examples, one of high symmetry and the other of low symmetry; this study highlights how program performance can vary significantly depending on the given problem. In addition, the final refined structure of the 16-dodecamer triclinic crystal form is analysed and shown not to be a superlattice structure, but rather an F-centred cubic crystal with frustrated crystallographic symmetry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular replacement then and now

A brief overview, with examples, of the evolution of molecular-replacement methods and models over the past few years is presented. The ‘phase problem’ in crystallography results from the inability to directly measure the phases of individual diffracted X-ray waves. While intensities are directly measured during data collection, phases must be obtained by other means. Several phasing methods are available (MIR, SAR, MAD, SAD and MR) and they all rely on the premise that phase information can be obtained if the positions of marker atoms in the unknown crystal structure are known. This paper is dedicated to the most popular phasing method, molecular replacement (MR), and represents a personal overview of the development, use and requirements of the methodology. The first description of noncrystallographic symmetry as a tool for structure determination was explained by Rossmann and Blow [Rossmann & Blow (1962 ▶), Acta Cryst.15, 24–31]. The term ‘molecular replacement’ was introduced as the name of a book in which the early papers were collected and briefly reviewed [Rossmann (1972 ▶), The Molecular Replacement Method. New York: Gordon & Breach]. Several programs have evolved from the original concept to allow faster and more sophisticated searches, including six-dimensional searches and brute-force approaches. While careful selection of the resolution range for the search and the quality of the data will greatly influence the outcome, the correct choice of the search model is probably still the main criterion to guarantee success in solving a structure using MR. Two of the main parameters used to define the ‘best’ search model are sequence identity (25% or more) and structural similarity. Another parameter that may often be undervalued is the quality of the probe: there is clearly a relationship between the quality and the correctness of the chosen probe and its usefulness as a search model. Efforts should be made by all structural biologists to ensure that their deposited structures, which are potential search probes for future systems, are of the best possible quality.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The replacement correction factor for the BIPM flat cavity ion chamber and the value of W/e

A graphite flat cavity ionization chamber is used at the BIPM in France to determine the absorbed dose to graphite in a {sup 60}Co photon beam and thereby used to determine the product of the value of W/e, the average energy required to produce an ion pair in dry air, and the value of (L{sub {Delta}}/{rho}){sub a}{sup C}, the mean restricted mass collision stopping-power ratio for graphite to air in a {sup 60}Co beam. The accuracy of the (W/e) (L{sub {Delta}}/{rho}){sub a}{sup C} value thus determined depends upon the accuracy of the perturbation correction factors adopted for this chamber. The perturbation effect of this chamber was accounted for by the replacement correction factor whose value was calculated by an analytical method and confirmed by an EGS4 Monte Carlo calculation. The purpose of this study is to investigate the validity of the analytical and the EGS4 calculations by using recently established methods and the EGSnrc Monte Carlo code, a much improved version of EGS4, to calculate the replacement correction factors for the graphite chamber. It is found that the replacement correction factors used for the BIPM chamber are not correct: the values used are smaller than they should be by about 1%. This leads to a 1% overestimation of the (W/e) (L{sub {Delta}}/{rho}){sub a}{sup C} value determined by using this chamber. This implies that {sup 60}Co air kerma standards that are directly proportional to this product need to be reduced by 1%. Based on the values of the replacement correction factors calculated in this study, and on the value of (L{sub {Delta}}/{rho}){sub a}{sup C} evaluated from ICRU Report No. 37 stopping power for graphite, the value of W/e determined by using the BIPM chamber should be 33.61{+-}0.08 J/C. If a more recent value of mean excitation energy for graphite (86.8 eV) and grain density are used to evaluate the graphite stopping power, then the value obtained for W/e is 34.15{+-}0.08 J/C.

61 RADIATION PROTECTION AND DOSIMETRY↗

Flow Injection Electrochemical Quartz Crystal Microbalance with ICP-OES Detection: Recovery of Silver by Electrodeposition with Redox Replacement in a Flow Cell

We developed a new on-line hyphenated flow injection analysis technique (FI-EQCM-ICP-OES) that allows electrochemical deposition and stripping with mass detection and elemental analysis. This technique was used to study a new system for electrochemical recovery of silver from a 0.5 mM Ag + /5 mM Cu 2+ /0.5 M H 2 SO 4 solution by pulsed electrodeposition with redox replacement (EDRR) in a small flow cell. The metal ions in a 500 μ l sample are injected into the sulfuric acid carrier stream and deposited onto an electrochemical quartz crystal microbalance (EQCM) electrode housed in a 50 μ l flow cell. The deposits are subsequently stripped off electrochemically in the same cell and analyzed downstream in an ICP-OES. The stripped metal layer was found to be composed of Ag with no detectable Cu for a redox replacement time of 10 s, and 91 wt.% Ag–9 wt.% Cu for a redox replacement time of 5 s. Microscopy measurements demonstrated that the electrode was covered with silver particles, some of which contain Cu in the case of the 5 s replacement time. This technique allowed the study of mass changes on the electrode during electrodeposition and open circuit times in each EDRR cycle in flowing solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crude Glycerol as Cost-Effective Fuel for Combined Heat and Power to Replace Fossil Fuels (Final Technical Report)

The primary objectives of this work can be summed into two major categories. Firstly, the fundamentals of the combustion of glycerol (in both a refined and unrefined form) were to be investigated, with emphasis of the development of a system capable of reliably and repeatedly combusting glycerol as well as an analysis of the emissions produced during glycerol combustion. Focus was placed on quantifying common emissions in comparison to more traditional fuels and this work showed that the burner developed was able to completely combust glycerol within a relatively wide range of operating conditions. Additionally, focus was placed on examining specific emissions in more detail, namely interesting NOx emissions observed in initial trials, acrolein and other volatile organic emissions, and particulate and ash emissions. This work showed that the combustion of crude glycerol could result in significantly reduced NOx emissions as a function of the high fuel bound oxygen content within the glycerol fuel. It also showed that when burned properly, the combustion of crude glycerol did not result in excessive emissions of acrolein or any other VOC compared to the combustion from more traditional fuels. Lastly however, this work has shown that in any practical application in which glycerol is being burned, it will be necessary to explore ash mitigation techniques due to the very high particulate matter concentrations produced during glycerol combustion. These emissions are comparable to unfiltered coal combustion and are directly tied to the biodiesel production method. The second focus of this work was directed to developing a commercialization strategy for the use of glycerol as a fuel replacement. This strategy has identified a 30 month plan for the scaling up of the laboratory scale burner into a pre-pilot scale system. Additionally, financing options were explored and an assessment was made of the economics of replacing a traditional fuel (namely natural gas) with crude glycerol from biodiesel production. This analysis showed that the cost of replacing natural gas with crude glycerol requires a strong function of the market price per unit of energy for the traditional fuel. However, the economics can be improved through the inclusion of a federal tax credit for the use of a renewable fuel. The conclusion of this analysis also shows that the ideal customer for energy replacement via crude glycerol is biodiesel producers who are located in remote regions, where the cost of energy is higher and the cost of crude glycerol is lowest. Lastly, the commercialization strategy analyzed competing technologies, namely traditional natural gas and electric heaters, as well as competing glycerol burners, and concludes with a discussion of the requirements for a pilot demonstration.

09 BIOMASS FUELS↗

Cost Modelling for Energy Efficient Window Replacements

This paper detailed data collection and cost-modeling efforts to understand the hardware and non-hardware (soft) cost of residential, energy efficient window replacements. NREL created a bottom-up cost model that details costs associated with window materials, installation labor, company overhead, and administrative costs. NREL did not find a single cost area for improvement but observed several non-cost barriers to increased window replacements. The non-cost barriers associated with window replacements are consumer education, lack of communication of the value of window replacement to consumers, and difficulty for consumers to identify quality products and installation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Can a Nuclear-Assisted Biofuels System Enable Liquid Biofuels as the Economic Low-carbon Replacement for All Liquid Fossil Fuels and Hydrocarbon Feedstocks and Enable Negative Carbon Emissions?

This report integrates the results of a series of studies and workshops to address the question: Can a nuclear-assisted biofuels system enable liquid biofuels as the economic low-carbon replacement for all liquid fossil fuels and hydrocarbon feedstocks and simultaneously enable negative carbon emissions? “Economic” is defined as economically competitive relative to other low-carbon replacement options for crude oil. “All” refers to the capability to replace the 18 million barrels of oil per day used by the United States. “Nuclear-assisted” refers to the provision of massive quantities of low-carbon heat and hydrogen at the refinery to fully utilize the carbon content of the cellulosic biomass feedstocks for liquid hydrocarbon production. A system is proposed that decarbonizes about half of the U.S. economy while improving long-term soil productivity and sequestering carbon from the atmosphere. In the U.S. almost half the energy consumed by the final customer is in the form of liquid hydrocarbons produced from crude oil. Liquid hydrocarbons are used as (1) an energy source, (2) a method for daily-to-seasonal energy storage, (3) a chemical feedstock, (4) a chemical reducing agent, (5) a method to enhance high-temperature heat transfer in many furnaces and industrial processes and (6) other purposes. As a consequence, the U.S. consumes ~18 million barrels of crude oil per day to produce liquid hydrocarbons. While there are substitutes for liquid hydrocarbons for some applications, our assessment is that the costs and difficulty will dramatically increase if liquid hydrocarbon use goes much below the equivalent of 10 million barrels per day of crude oil. New uses of liquid hydrocarbons to partly replace coal and natural gas could increase demand beyond the equivalent of 10 million barrels of oil per day. One can produce and burn liquid hydrocarbons from biomass without any net addition of carbon dioxide to the atmosphere. Plants grow by removing carbon dioxide from the atmosphere; thus, burning biomass does not result in any net addition of carbon dioxide to the atmosphere. Biomass is typically 40% oxygen. To remove this oxygen to create hydrocarbon liquids, there are two options. The first option is to use biomass as (1) a feedstock, (2) an energy source to operate the process and (3) a supply of carbon to remove the biomass oxygen as carbon dioxide. The second option is to use external heat and hydrogen to remove the oxygen as water and produce liquid hydrocarbons. The use of massive quantities of external heat and hydrogen for hydrocarbon liquid fuels production reduces the biomass feedstock per unit of liquid hydrocarbon product by more than a factor of two reducing land use by more than a factor of two. Many cellulosic feedstocks unsuitable for liquid hydrocarbon production are viable feedstocks with external heat and hydrogen inputs. As a result, there is sufficient cellulosic feedstocks to meet U.S. and global liquid fuels hydrocarbon demand without significant impacts on food and fiber prices. The heat and hydrogen (heat plus electricity) are produced using base-load nuclear power plants—the most economic form of nuclear energy. If low-price natural gas, there is also the option of producing hydrogen from natural gas with sequestration of the carbon dioxide. The biomass is locally processed in depots to produce commodity feedstocks that can be shipped long distances to large biorefineries (250,000 barrels per day, oil equivalent) similar to existing refineries except modifications of front-end processes. The depot system enables local recycle of nutrients back to the soil. The biorefinery can produce variable quantities of liquid hydrocarbon fuels and carbon dioxide for sequestration enabling removal of carbon dioxide from the atmosphere. Preliminary estimates are that the liquid hydrocarbon costs are equivalent to crude oil at between $60 and $70 per barrel. The largest cost is for hydrogen with biomass feedstocks and refinery costs a smaller fraction of the total cost.

09 BIOMASS FUELS↗

Analyses of Dose Rates for Second Inner Reflector Plug Replacement at Spallation Neutron Source

The Inner Reflector Plug (IRP) is a central component of the Spallation Neutron Source (SNS) target monolith, which houses the liquid mercury target and four liter-sized neutron moderator units. It is exposed to high-level radiation fields during routine operation and builds up significant activity. The IRP needs to be replaced due to moderator neutron poison and decoupler burn-out, which is used for shaping neutron pulses. The first IRP exchange took place in March 2018 and next one, which is IRP2, is planned to be replaced during the facility maintenance period in the end of December 2025, beginning of January 2026 calendar year. The replacement of IRP is a complex task due to its location in the area receiving high irradiation, being under significant amount of shielding, and size, which requires removal in segments. For planning the replacement workflow to help to reduce radiation exposure to workers dose rates for each stage of extraction/replacement operation are predicted.

42 ENGINEERING↗

Cold Trap Replacement Project Report

This report documents the replacement of the Mechanisms Engineering Test Loop (METL) cold trap. The work involved preparation of the facility to replace the cold trap, removal of the existing welded cold trap from the sodium purification circuit, installation of a new replacement cold trap, completion of associated welds and examinations, restoration of instrumentation and heaters, and controlled return of the cold trap circuit to service. The replacement represented a significant maintenance evolution because the cold trap is an integral welded component of the sodium system. As a result, the work required coordinated control of sodium chemistry, deliberate formation of freeze plugs, inert gas management, precision cutting and welding, and a staged reheating and refill sequence. The activity was executed using procedural controls intended to protect personnel, preserve system cleanliness, and maintain the integrity of the sodium boundary throughout the work. This report provides a narrative summary of the milestone, including the purpose of the work, the pre-job system condition, the major field activities performed, observations made during execution, and the resulting post-work condition of the METL cold trap circuit.

42 ENGINEERING↗

The IAEA Workshop on Requirements and Potential Technologies for Replacement of 3He Detectors in IAEA Safeguards Applications

From 22 – 24 March, 2011, the International Atomic Energy Agency (IAEA) held an international workshop to address the question of a possible replacement for helium-3 based neutron detectors. Within this wider scope, the workshop was focused on those applications used in IAEA verification activities. There were two principle objectives of the workshop: 1) to determine the specific requirements that a potential replacement technology would have to satisfy, and 2) to identify alternative detector technologies that appear promising for meeting those requirements. The workshop was successful in achieving both objectives. A set of detailed and quantitative specifications was developed and achieved a general consensus among the conference participants. These included operational considerations such as temperature stability, safety, weight, and cost in addition to a number of performance requirements. The performance requirements were derived from an analysis of the spectrum of IAEA applications that use neutron detectors. After analyzing these applications, it was determined that the most common application for 3He detectors was for neutron coincidence counting, comprising over 95% of 3He use. The details and rationale for this assessment will be provided. The performance requirements for neutron coincidence counting can be directly calculated from the standard variance expressions. From these, a basic figure of merit (FOM) was developed that can be used to rank various different options. For neutron coincidence counting, the figure of merit is: , where ε is the detection efficiency and is the detector die away time. Both the FOM and the calculations will be presented. The full list of requirements is included in this paper. The second purpose of the workshop was to identify promising replacement technologies. There were multiple presentations of candidate detection technologies over the course of the workshop, covering a wide spectrum of approaches and detection physics. These technologies were judged relative to the performance of a 3He-based system, as well as its ability to meet the replacement technology requirements as developed in this workshop. The paper will present a summary of this assessment.

Pickrell, Mark↗

Diablo Canyon power plant digital process protection system replacement licensing experience using ISG-06 - 395

This paper provides a summary of the preparation of a License Amendment Request (LAR) for replacement of the existing Diablo Canyon Power Plant (DCPP) Eagle 21 digital Process Protection System (PPS) by Pacific Gas and Electric Company (PG and E) using US Nuclear Regulatory Commission (USNRC) Digital I and C (DI and C) Interim Staff Guidance (ISG) document ISG-06, Licensing Process . The USNRC has designated the LAR for the DCPP PPS replacement project as the pilot application for use of DI and C ISG-06. DI and C ISG-06, Revision 1, issued for use on January 19, 2011, describes the licensing process the NRC staff may use to review an LAR for a DI and C modification. The LAR for the replacement of the Eagle 21 PPS was submitted to the NRC on October 26, 2011, was accepted for review on January 13, 2012, and was approved on December 21, 2016. A more detailed review of the specific PPS replacement design including the Defense-In-Depth and Diversity approach is provided in a paper presented at the 2015 conference. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Walgreens RTU Replacement Program: Advanced RTU Campaign

This case study describes Walgreens’ program to strategically retire RTUs prior to failure and replace them with high-efficiency units in 150 stores, which realized more than $1 million in savings from material and labor budgets by right-sizing equipment and optimizing replacements, compared to an emergency replace upon failure mode.

rooftop unit, RTU, replace, replacement, retail, H↗