Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution test pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SU-F-T-549: Validation of a Method for in Vivo 3D Dose Reconstruction for SBRT Using a New Transmission Detector

Purpose: Recently, there has been increased clinical use of stereotactic body radiation therapy (SBRT). SBRT treatments will strongly benefit from in vivo patient dose verification, as any errors in delivery can be more detrimental to the radiobiology of the patient as compared to conventional therapy. In vivo dose measurements, a commercially available quality assurance platform which is able to correlate the delivered dose to the patient’s anatomy and take into account tissue inhomogeneity, is the COMPASS system (IBA Dosimetry, Germany) using a new transmission detector (Dolphin, IBA Dosimetry). In this work, we evaluate a method for in vivo 3D dose reconstruction for SBRT using a new transmission detector, which was developed for in vivo dose verification for intensity-modulated radiation therapy (IMRT). Methods: We evaluated the accuracy of measurement for SBRT using simple small fields (2×2−10×10 cm2), a multileaf collimator (MLC) test pattern, and clinical cases. The dose distributions from the COMPASS were compared with those of EDR2 films (Kodak, USA) and the Monte Carlo simulations (MC). For clinical cases, we compared MC using dose-volume-histograms (DVHs) and dose profiles. Results: The dose profiles from the COMPASS for small fields and the complicated MLC test pattern agreed with those of EDR2 films, and MC within 3%. This showed the COMPASS with Dolphin system showed good spatial resolution and can measure small fields which are required for SBRT. Those results also suggest that COMPASS with Dolphin is able to detect MLC leaf position errors for SBRT. In clinical cases, the COMPASS with Dolphin agreed well with MC. The Dolphin detector, which consists of ionization chambers, provided stable measurement. Conclusion: COMPASS with Dolphin detector showed a useful in vivo 3D dose reconstruction for SBRT. The accuracy of the results indicates that this approach is suitable for clinical implementation.

60 APPLIED LIFE SCIENCES↗

Species richness and endemism in the native flora of California

California’s vascular flora is the most diverse and threatened in temperate North America. Previous studies of spatial patterns of Californian plant diversity have been limited by traditional metrics, non-uniform geographic units, and distributional data derived from floristic descriptions for only a subset of species. We revisited patterns of sampling intensity, species richness, and relative endemism in California based on equal-area spatial units, the full vascular flora, and specimen-based distributional data. We estimated richness, weighted endemism (inverse range-weighting of species), and corrected weighted endemism (weighted endemism corrected for richness), and performed a randomization test for significantly high endemism. Possible biases in herbarium data do not obscure patterns of high richness and endemism at the spatial resolution studied. High species richness was sometimes associated with significantly high endemism (e.g., Klamath Ranges) but often not. In Stebbins and Major’s (1965) main endemism hotspot, Southwestern California, species richness is high across much of the Peninsular and Transverse ranges but significantly high endemism is mostly localized to the Santa Rosa and San Bernardino mountains. In contrast, species richness is low in the Channel Islands, where endemism is significantly high, as also found for much of the Death Valley region. Measures of taxonomic richness, even with greater weighting of range-restricted taxa, are insufficient for identifying areas of significantly high endemism that warrant conservation attention. Differences between our findings and those in previous studies appear to mostly reflect the source and scale of distributional data, and recent analytical refinements.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical upscaling of ecosystem CO 2 fluxes across the terrestrial tundra and boreal domain: Regional patterns and uncertainties

Abstract The regional variability in tundra and boreal carbon dioxide (CO 2 ) fluxes can be high, complicating efforts to quantify sink‐source patterns across the entire region. Statistical models are increasingly used to predict (i.e., upscale) CO 2 fluxes across large spatial domains, but the reliability of different modeling techniques, each with different specifications and assumptions, has not been assessed in detail. Here, we compile eddy covariance and chamber measurements of annual and growing season CO 2 fluxes of gross primary productivity (GPP), ecosystem respiration (ER), and net ecosystem exchange (NEE) during 1990–2015 from 148 terrestrial high‐latitude (i.e., tundra and boreal) sites to analyze the spatial patterns and drivers of CO 2 fluxes and test the accuracy and uncertainty of different statistical models. CO 2 fluxes were upscaled at relatively high spatial resolution (1 km 2 ) across the high‐latitude region using five commonly used statistical models and their ensemble, that is, the median of all five models, using climatic, vegetation, and soil predictors. We found the performance of machine learning and ensemble predictions to outperform traditional regression methods. We also found the predictive performance of NEE‐focused models to be low, relative to models predicting GPP and ER. Our data compilation and ensemble predictions showed that CO 2 sink strength was larger in the boreal biome (observed and predicted average annual NEE −46 and −29 g C m −2 yr −1 , respectively) compared to tundra (average annual NEE +10 and −2 g C m −2 yr −1 ). This pattern was associated with large spatial variability, reflecting local heterogeneity in soil organic carbon stocks, climate, and vegetation productivity. The terrestrial ecosystem CO 2 budget, estimated using the annual NEE ensemble prediction, suggests the high‐latitude region was on average an annual CO 2 sink during 1990–2015, although uncertainty remains high.

Virkkala, Anna‐Maria↗

High resolution multispectral camera system for ERTS A & B

A very high resolution multispectral television camera system has been developed for NASA for use on the Earth Resources Technology Satellite (ERTS) program. There are three cameras in the system, each viewing the same area but operating in the blue-green, red, and near-infrared spectral bands. In the laboratory the cameras' limiting resolution is 4500 TV lines over the 25 x 25-mm image format of the Return Beam Vidicon (RBV). Analysis of typical ERTS scenes shows that actual contrast ratios will be much lower than those of laboratory test targets. A model was developed to predict the resolving power performance of the RBV camera under realistic conditions. To verify the model, tests were conducted using the RBV camera, a laser-beam image reproducer and a series of AF tribar test patterns of known values of contrast. As a more graphic demonstration, simulated multispectral images were generated using color-IR photographs from Apollo 9. The measured signal-to-noise, resolution, and spectral characteristics of the ERTS Flight A and Flight B three-camera systems are presented in conclusion.

Miller, B. P.↗

Identifying Climate Patterns Using Clustering Autoencoder Techniques

Abstract The complexity of growing spatiotemporal resolution of climate simulations produces a variety of climate patterns under different projection scenarios. This paper proposes a new data-driven climate classification workflow via an unsupervised deep learning technique that can dimensionally reduce the vast volume of spatiotemporal numerical climate projection data into a compact representation. We aim to identify distinct zones that capture multiple climate variables as well as their future changes under different climate change scenarios. Our approach leverages convolutional autoencoders combined with k -means clustering (standard autoencoder) and online clustering based on the Sinkhorn–Knopp algorithm (clustering autoencoder) across the conterminous United States (CONUS) to capture unique climate patterns in a data-driven fashion from the Geophysical Fluid Dynamics Laboratory Earth System Model with GOLD component (GFDL-ESM2G). The developed approach compresses 70 years of GFDL-ESM2G simulation at 0.125° spatial resolution across the CONUS under multiple warming scenarios to a lower-dimensional space by a factor of 660 000 and then tested on 150 years of GFDL-ESM2G simulation data. The results show that five climate clusters capture physically reasonable and spatially stable climatological patterns matched to known climate classes defined by human experts. Results also show that using a clustering autoencoder can reduce the computational time for clustering by up to 9.2 times when compared to using a standard autoencoder. Our five unique climate patterns resulting from the deep learning–based clustering of the lower-dimensional space thereby enable us to provide insights on hydrometeorology and its spatial heterogeneity across the conterminous United States immediately without downloading large climate datasets. Significance Statement This paper presents a data-driven climate classification approach using unsupervised deep learning to dimensionally reduce climate model outputs and to identify distinct climate regions for their future changes. Our approach compresses climate information for 70 years of Geophysical Fluid Dynamics Laboratory Earth System Model data across the conterminous United States (CONUS) at 0.125° spatial resolution. The results reveal that five climate clusters capture reasonable and stable climatological patterns matched to known climate patterns. The embedded clustering process in deep learning provides ×9.2 times faster execution than the k -means clustering technique. These results give us insight about climate spatial patterns and heterogeneity of hydrological patterns across the conterminous United States without downloading large climate datasets.

Kurihana, Takuya↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Femtosecond Time-Delay X-Ray Holography

X-ray free-electron lasers (XFELs) will produce photon pulses with a unique and desirable combination of properties. Their short X-ray wavelengths allow penetration into materials and the ability to probe structure at and below the nanometer scale. Their ultra-short duration gives information about this structure at the fundamental time-scales of atoms and molecules. The extreme intensity of the pulses will allow this information to be acquired in a single shot, so that these studies can be carried out on non-repeatable processes or on weakly-scattering objects that will be modified by the pulse. A fourth property of XFEL pulses is their high transverse coherence, which brings the promise of decades of innovation in visible optics to the X-ray regime, such as holography, interferometry, and laser-based imaging. Making an effective use of XFEL pulses, however, will benefit from innovations that are new to both X-ray science and coherent optics. One such innovation is the new method of time-delay X-ray holography [1], recently demonstrated at the FLASH FEL at DESY in Hamburg, to measure the evolution of objects irradiated by intense pulses. One of the pressing questions about the high-resolution XFEL imaging and characterization of non-periodic or weakly-scattering objects is the effect of the intense FEL pulse on the object, during the interaction with that pulse. The method of single-particle diffraction imaging [2] requires a stream of reproducible particles (e.g. a protein complex or virus) inserted into the beam, whereby a coherent X-ray diffraction pattern is recorded. The pulse will completely destroy the object, but if the pulse is short enough the diffraction pattern will represent the undamaged object. This ultrafast flash imaging was demonstrated at the FLASH FEL using test objects that included microfabricated patterns in silicon nitride foils [3]. Those experiments showed that no damage occurred during the 30 fs duration pulse. However, in those experiments the imaging resolution was limited by the long 32 nm wavelength at which the facility was then operating. We wished to dramatically increase our sensitivity to the particles explosions, to be able to increase the understanding of the dynamics of particles and predict the imaging performance at XFELs such as the LCLS. This was done in two ways in a single experiment: by holographically measuring the time evolution of the particle at times after the pulse had pass through the object; and by making an interferometric measurement of the change in the optical path through the object. The experimental technique, time-delay holography, achieved a time resolution better than 3 fs, and a phase sensitivity of better than 3{sup o}, or a sensitivity of < 3 nm of the expansion of the particles.

59 BASIC BIOLOGICAL SCIENCES↗

On-Orbit Lunar Modulation Transfer Function Measurements for the Moderate Resolution Imaging Spectroradiometer

Spatial quality of an imaging sensor can be estimated by evaluating its modulation transfer function (MTF) from many different sources such as a sharp edge, a pulse target, or bar patterns with different spatial frequencies. These well-defined targets are frequently used for prelaunch laboratory tests, providing very reliable and accurate MTF measurements. A laboratory-quality edge input source was included in the spatial-mode operation of the Spectroradiometric Calibration Assembly (SRCA), which is one of the onboard calibrators of the Moderate Resolution Imaging Spectroradiometer (MODIS). Since not all imaging satellites have such an instrument, SRCA MTF estimations can be used as a reference for an on-orbit lunar MTF algorithm and results. In this paper, the prelaunch spatial quality characterization process from the Integrated Alignment Collimator and SRCA is briefly discussed. Based on prelaunch MTF calibration using the SRCA, a lunar MTF algorithm is developed and applied to the lifetime on-orbit Terra and Aqua MODIS lunar collections. In each lunar collection, multiple scan-directionMoon-to-background transition profiles are aligned by the subpixel edge locations from a parametric Fermi function fit. Corresponding accumulated edge profiles are filtered and interpolated to obtain the edge spread function (ESF). The MTF is calculated by applying a Fourier transformation on the line spread function through a simple differentiation of the ESF. The lifetime lunar MTF results are analyzed and filtered by a relationship with the Sun-Earth-MODIS angle. Finally, the filtered lunarMTF values are compared to the SRCA MTF results. This comparison provides the level of accuracy for on-orbit MTF estimations validated through prelaunch SRCA measurements. The lunar MTF values had larger uncertainty than the SRCA MTF results; however, the ratio mean of lunarMTF fit and SRCA MTF values is within 2% in the 250- and 500-m bands. Based on the MTF measurement uncertainty range, the suggested lunar MTF algorithm can be applied to any on-orbit imaging sensor with lunar calibration capability.

Choi, Taeyong↗

Use of high-granularity CdZnTe pixelated detectors to correct response non-uniformities caused by defects in crystals

Following our successful demonstration of the position-sensitive virtual Frisch-grid detectors, we investigated the feasibility of using high-granularity position sensing to correct response non-uniformities caused by the crystal defects in CdZnTe (CZT) pixelated detectors. The development of high-granularity detectors able to correct response non-uniformities on a scale comparable to the size of electron clouds opens the opportunity of using unselected off-the-shelf CZT material, whilst still assuring high spectral resolution for the majority of the detectors fabricated from an ingot. Here, we present the results from testing 3D position-sensitive 15×15×10 mm 3 pixelated detectors, fabricated with conventional pixel patterns with progressively smaller pixel sizes: 1.4, 0.8, and 0.5 mm. We employed the readout system based on the H3D front-end multi-channel ASIC developed by BNL's Instrumentation Division in collaboration with the University of Michigan. We use the sharing of electron clouds among several adjacent pixels to measure locations of interaction points with sub-pixel resolution. By using the detectors with small-pixel sizes and a high probability of the charge-sharing events, we were able to improve their spectral resolutions in comparison to the baseline levels, measured for the 1.4-mm pixel size detectors with small fractions of charge-sharing events. These results demonstrate that further enhancement of the performance of CZT pixelated detectors and reduction of costs are possible by using high spatial-resolution position information of interaction points to correct the small-scale response non-uniformities caused by crystal defects present in most devices.

36 MATERIALS SCIENCE↗

Deformation Mechanism Transition in Additively Manufactured Compositionally Graded Fe-Base Alloys

Microstructure-dependent deformation and fracture behavior was investigated for an additively manufactured compositionally graded alloy (CGA) printed using the laser-directed energy deposition (L-DED) method to explore an alternative approach for dissimilar metal joints in nuclear energy systems. The electron backscatter diffraction (EBSD) maps from scanning electron microscopy (SEM) display a clear microstructural transition with decreasing austenite-forming elements (Ni and Mn), from an austenite (γ) dominant structure, to a complex composite structure containing ferrite (α), martensite (α') and retained austenite, and then to a fully ferritic structure. EBSD data were recorded in situ during tensile testing in SEM, and the evolution of the deformation mechanism and microstructure was characterized using Kikuchi diffraction pattern analysis. Complementary analysis for high-resolution features was also performed using scanning transmission electron microscopy (STEM). The Ni/Mn-rich austenite-dominant microstructures showed a complex deformation mechanism of two-step martensitic transformation (γ→ε→α'), whereas the minor austenite phase retained in the ferrite and/or martensite matrix showed a single transformation route (γ→α'). Ordinary dislocation glide and twinning via partial dislocation glide were observed in the austenite deformation. Meanwhile, the ferrite and martensite grains deformed mainly by ordinary dislocation slips and grain rotation. Furthermore, static tensile fracture was also highly dependent on local composition and phase constituents.

36 MATERIALS SCIENCE↗

Comparison of 3-dimensional dose reconstruction system between fluence-based system and dose measurement-guided system

COMPASS system (IBA Dosimetry, Schwarzenbruck, Germany) and ArcCHECK with 3DVH software (Sun Nuclear Corp., Melbourne, FL) are commercial quasi-3-dimensional (3D) dosimetry arrays. Cross-validation to compare them under the same conditions, such as a treatment plan, allows for clear evaluation of such measurement devices. In this study, we evaluated the accuracy of reconstructed dose distributions from the COMPASS system and ArcCHECK with 3DVH software using Monte Carlo simulation (MC) for multi-leaf collimator (MLC) test patterns and clinical VMAT plans. In a phantom study, ArcCHECK 3DVH showed clear differences from COMPASS, measurement and MC due to the detector resolution and the dose reconstruction method. Especially, ArcCHECK 3DVH showed 7% difference from MC for the heterogeneous phantom. ArcCHECK 3DVH only corrects the 3D dose distribution of treatment planning system (TPS) using ArcCHECK measurement, and therefore the accuracy of ArcCHECK 3DVH depends on TPS. In contrast, COMPASS showed good agreement with MC for all cases. However, the COMPASS system requires many complicated installation procedures such as beam modeling, and appropriate commissioning is needed. In terms of clinical cases, there were no large differences for each QA device. The accuracy of the compass and ArcCHECK 3DVH systems for phantoms and clinical cases was compared. Both systems have advantages and disadvantages for clinical use, and consideration of the operating environment is important. The QA system selection is depending on the purpose and workflow in each hospital.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pilot response to avoidance regions depicted on alternate TCAS II resolution advisory displays

The objective of this study was to examine pilot reactions to three versions of the resolution advisory (RA) display of the TCAS II. Two modifications to the current system were designed to test the hypothesis that a different lighting pattern might be more effective than the 'red-only' version currently in use. Grouped into three sets, 28 RA displays of the same color pattern ('red-only', 'red-and-green', and 'green-only') were presented to 36 volunteer pilots on an IRIS terminal. The results indicated that the red-and-green display caused the least errors and hastened a quicker response than did the red-only display. Further, a subjective evaluation revealed that the pilots preferred the red-and-green display over the other two options. The red-only display caused the most errors, including seven unnecessary maneuvers. Pilots also responded slowest to this display and it was the least preferred.

Tuttell, Robert J.↗

Demonstration of 12 nm resolution Fresnel zone plate lens based soft x-ray microscopy

To extend soft x-ray microscopy to a resolution of order 10 nm or better, we developed a new nanofabrication process for Fresnel zone plate lenses. The new process, based on the double patterning technique, has enabled us to fabricate high quality gold zone plates with 12 nm outer zones. Testing of the zone plate with the full-field transmission x-ray microscope, XM-1, in Berkeley, showed that the lens clearly resolved 12 nm lines and spaces. This result represents a significant step towards 10 nm resolution and beyond.

36 MATERIALS SCIENCE↗

3D diffractive imaging of nanoparticle ensembles using an x-ray laser

Single particle imaging at x-ray free electron lasers (XFELs) has the potential to determine the structure and dynamics of single biomolecules at room temperature. Two major hurdles have prevented this potential from being reached, namely, the collection of sufficient high-quality diffraction patterns and robust computational purification to overcome structural heterogeneity. We report the breaking of both of these barriers using gold nanoparticle test samples, recording around 10 million diffraction patterns at the European XFEL and structurally and orientationally sorting the patterns to obtain better than 3-nm-resolution 3D reconstructions for each of four samples. With these new developments, integrating advancements in x-ray sources, fast-framing detectors, efficient sample delivery, and data analysis algorithms, we illuminate the path towards sub-nanometer biomolecular imaging. The methods developed here can also be extended to characterize ensembles that are inherently diverse to obtain their full structural landscape.

47 OTHER INSTRUMENTATION↗

A modified commercial scanner as an image plate for table-top optical applications

A reliable, accurate, and inexpensive optical detector for table-top applications is described here. Based on a commercial high resolution office scanner coupled to a projection on plate, it enables a large image plate surface, allowing recording of large images without systematic errors associated to coupling optics' aberrations. Several tests on distance-dependent and steady interference patterns will be presented and discussed. The extension to other types of optical measurement by substituting the projection on plate is proposed.

47 OTHER INSTRUMENTATION↗

Rapid model building of β-sheets in electron-density maps

A method for rapid model building of β-sheets at moderate resolution is presented. A method for rapidly building β-sheets into electron-density maps is presented. β-Strands are identified as tubes of high density adjacent to and nearly parallel to other tubes of density. The alignment and direction of each strand are identified from the pattern of high density corresponding to carbonyl and C{sup β} atoms along the strand averaged over all repeats present in the strand. The β-strands obtained are then assembled into a single atomic model of the β-sheet regions. The method was tested on a set of 42 experimental electron-density maps at resolutions ranging from 1.5 to 3.8 Å. The β-sheet regions were nearly completely built in all but two cases, the exceptions being one structure at 2.5 Å resolution in which a third of the residues in β-sheets were built and a structure at 3.8 Å in which under 10% were built. The overall average r.m.s.d. of main-chain atoms in the residues built using this method compared with refined models of the structures was 1.5 Å.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Verifying infectious disease scenario planning for geographically diverse populations

In the face of the COVID-19 pandemic, the literature saw a spike in publications for epidemic models, and a renewed interest in capturing contact networks and geographic movement of populations. There remains a general lack of consensus in the modeling community around best practices for spatiotemporal epi-modeling, specifically as it pertains to the infection rate formulation and the underlying contact or mixing model. We mathematically verify several common modeling assumptions in the literature, to prove when certain choices can provide consistent results across different geographic resolutions, population densities and patterns, and mixing assumptions. The most common infection rate formulation, a computationally low cost per capita infection rate assumption, fails the consistency tests for heterogeneous populations and gravity-weighting assumptions. Future modeling efforts in spatiotemporal disease modeling should be wary of this limitation, particularly when working with more heterogeneous or sparse populations. Our results provide guidance for testing that a model preserves desirable properties even when model inputs mask potential problems due to symmetry or homogeneity. We also provide a recipe for performing this type of verification, strengthening decision support tools.

59 BASIC BIOLOGICAL SCIENCES↗

Hartmann characterization of the PEEM-3 aberration-corrected X-ray photoemission electron microscope

Aberration correction by an electron mirror dramatically improves the spatial resolution and transmission of photoemission electron microscopes. We will review the performance of the recently installed aberration corrector of the X-ray Photoemission Electron Microscope PEEM-3 and show a large improvement in the efficiency of the electron optics. Hartmann testing is introduced as a quantitative method to measure the geometrical aberrations of a cathode lens electron microscope. Here, we find that aberration correction leads to an order of magnitude reduction of the spherical aberrations, suggesting that a spatial resolution of below 100 nm is possible at 100% transmission of the optics when using x-rays. We demonstrate this improved performance by imaging test patterns employing element and magnetic contrast.

36 MATERIALS SCIENCE↗