Integrated Controls Package for High Performance Interior Retrofit [Slides]

For the last few years, networked lighting control (NLCs) have promised significant energy savings beyond what is achieved through a basic light-emitting diode (LED) lighting retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

U.S.-China Clean Energy Research Center Building Energy Efficiency (CERC-BEE) Open-Source Retrofit Targeting Tool (CRADA FP00007338 Final Report)

To increase the cost-saving energy and carbon dioxide (CO 2 ) emissions reductions in buildings and portfolios at the scale and speed necessary to limit climate change, researchers at LBNL and Johnson Controls (JCI) developed the Building Efficiency Targeting Tool for Energy Retrofits (BETTER). BETTER is a software tool that consists of three components: (1) the BETTER analytical engine source code (which was developed with intellectual property provided by JCI under CRADA FP00007338); (2) the BETTER web application, developed by LBNL and McQuillen Interactive Pty. Ltd; and (3) the BETTER application programming interface (API), also developed by LBNL and McQuillen Interactive Pty. Ltd. BETTER enables building and portfolio owners, managers, and service providers worldwide to quickly, easily identify cost-saving energy efficiency retrofits in existing buildings and portfolios without expensive site visits or complex modeling. With minimal data input, the tool benchmarks a building’s electric and fossil energy usage against peers; quantifies energy, cost and greenhouse gas (GHG) emission reduction potentials at the building and portfolio levels; and recommends energy efficiency measures to decarbonize and electrify buildings and portfolios, targeting specific energy savings levels. No other tool so comprehensively analyzes buildings and portfolios with such ease. If fully implemented, it is estimated that BETTER could help reduce emissions equivalent to planting 1.3 billion trees globally by 2030. Moreover, an additional 50-75% of embodied GHG emissions could be avoided in each case where BETTER results in a building being retrofitted instead of demolished and replaced, providing substantial additional decarbonization benefits for the buildings sector. BETTER has garnered multiple awards and avid interest from investors. In 2020, it earned a R&D 100 Award for innovation and a LBNL Director’s Award for Technology Transfer. In 2021, BETTER was named an EarthX E-Capital Summit Climate Tech Prize semi-finalist

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of flame propagation of retrofit energy efficient wall assemblies

Leveraging safety science experience and industry relationships, UL Solutions and the International Association of Fire Fighters (IAFF) initiated a joint project in 2022 under an agreement with the US Department of Energy to evaluate the flame propagation of retrofit energy efficient wall assemblies. A draft of the protocol from the ASTM work was used to test and comparatively study various retrofit energy efficient designs to gain a better understanding of their fire behavior. The goals of this study were as follows: Develop an understanding of fire propagation across new, cost effective, and energy efficient exterior retrofit wall assemblies. Refine the flame propagation draft test method for exterior wall assemblies based on ASTM E2707. Identify conditions that create fire propagation hazards in exterior wall assemblies and educate the fire service on the findings.

42 ENGINEERING↗

Project-specific considerations for retrofitting carbon capture technology to power generating and industrial facilities

The National Energy Technology Laboratory (NETL) has previously reported on learnings from 7 FEED studies examining retrofitting power plants with capture. This presentation builds on this effort by highlighting learnings from 3 additional FEED studies examining retrofitting power plants with capture and 7 FEED and pre-FEED studies examining retrofitting industrial plants with capture. This includes a discussion of the design, performance, and cost implications associated with (1) site-specific considerations such as water availability, land availability, and site accessibility, and (2) host-plant-specific factors such as flue gas specifications, operational mode, and allowable degree of integration between the capture system and host plant.

FEED Studies↗

Dynamic Analysis of a Six-Cable Parallel Robot for Automated Panelized Building Retrofits

Cable-Driven Parallel Robots (CDPRs) are highly suitable for automated panelized building retrofits, thanks to their compact footprint and high payload-to-weight ratio. A common CDPR configuration featuring eight cables, where the anchors form a rectangular prism in front of the building facade, offers a large wrench feasible workspace and good control versatility. However, installing upper anchor points requires additional support structures, such as towers or beams, increasing setup complexity and posing logistical challenges in construction settings. To mitigate these challenges, we propose a six-cable CDPR model specifically designed for automated panelized building retrofits. Although the feasible workspace is limited, our analysis shows that the proposed CDPR adequately covers the critical areas required for panel installation. To validate that the six-cable system can effectively transport the end effector to the desired installation pose, we calculated optimal trajectories based on a constrained dynamic model. The simulation results of the six-cable CDPR demonstrate promising potential for automated panelized building retrofits, effectively balancing simplicity, cost-effectiveness, and functionality.

Liu, Yifang [ORNL] (ORCID:0000000190817417)↗

Space shuttle orbiter trimmed center-of-gravity extension study. Volume 3: Impact of retrofits for center-of-gravity extension on orbiter thermal-protection system

Heat transfer studies were conducted at Mach 10.3 on space shuttle orbiter models with the S-2 fillet and C-4 canard retrofit moldlines which were generated in aerodynamic and system design studies to increase the allowable c.g. range of the orbiter. Areas of orbiter most strongly affected were the sides where a shear layer which separated along the wing leading edge impinged. Analytical studies of the heating effect on the thermal-protection system were made which indicated that scar weight on the orbiter sides due to allowances for retrofits of the S-2 fillet and C-4 canard is small (less than about 90 kg (200 lbs) in comparison to the total weight of the retrofit).

Dunavant, J. C.↗

Considerations for the retrofit of data link

Human factors issues related to the retrofit of data link in commercial transport aircraft are discussed. Topics that must be considered for data link implementation include, the loss of the party line, (i.e., the availability to all aircraft of information transmitted on a common voice frequency), and the scheduling of information to the flight crew. This paper focuses primarily on the human factors issues related to retrofit of Mode S. Retrofits is a difficult task because panel space accessible to flight crew members is limited. As with all cockpit equipment, data link implementation will have to comply with Federal Aviation Regulation 25.1523, which requires the manufacturer to address the conspicuity and ease of use of the data link device, and to assess the impact on crew workload. Operational sequence diagrams are provided to illustrate a methodology that can be used to decompose the flight crew body channel utilization of candidate avionics configurations in order to optimize the pilot-vehicle interface.

Corwin, William H.↗

Infrastructure Retrofit Design via Composite Mechanics

Select applications are described to illustrate the concept for retrofitting reinforced concrete infrastructure with fiber reinforced plastic laminates. The concept is first illustrated by using an axially loaded reinforced concrete column. A reinforced concrete arch and a dome are then used to illustrate the versatility of the concept. Advanced methods such as finite element structural analysis and progressive structural fracture are then used to evaluate the retrofitting laminate adequacy. Results obtains show that retrofits can be designed to double and even triple the as-designed load of the select reinforced concrete infrastructures.

Chamis, Christos, C.↗

Retrofit-ability: A supplementary metric to inform energy efficiency policies and programs

Building Energy Use Intensity (EUI) has been commonly used to facilitate policy makers and utilities to design energy efficacy programs and help building managers prioritize investment in building upgrades. Buildings with higher EUIs are usually chosen as better candidates for retrofit. Our study of nearly one hundred buildings in Seattle’s Building Tune Up Accelerator program and thousands of buildings in the Asset Score database reveals that EUI (after weather/location/use type normalization) alone is not the best indicator of a building’s potential to save energy, especially for those buildings in the mid-range (30-70 percentile EUI). In this paper, we introduce the concept of “retrofit-ability” — a building’s real potential to reduce its energy use cost-effectively — as a supplementary metric to inform energy efficiency policy and investment. Currently, such potential analyses are predicted for a building stock using prototypical building models or statistical data. However, typical buildings or general historical data may not sufficiently represent building configurations in a portfolio and predict their saving potentials. We utilized machine learning to investigate how key building characteristics (such as envelope attributes, HVAC type, location, use type, etc.) affect a building’s improvement potentials and developed a low-cost method to quantify such potentials for a portfolio of buildings. The supplementary perspective provided by “retrofit-ability” highlights which building assets correlate most with a building’s energy savings potential across region, building use type and more.

Wang, Na↗

Assessing the Performance, Application, and Cost of Retrofit Wall Systems for Residential Buildings

The Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and the University of Minnesota have been conducting a three-year study of residential retrofit wall systems. The researchers have identified, tested, and verified the hygrothermal performance of 16 wall assemblies in retrofit applications. The approach to this study includes a comprehensive literature review, the involvement of an advisory group of thermal enclosure experts, smallscale experimental in situ testing of the wall assemblies at the University of Minnesota’s Cloquet Residential Research Facility, and energy and hygrothermal simulation of wall assemblies using EnergyPlus, THERM, and WUFI. Simulation and experimental results are then combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits.This presentation summarizes the findings of this research project and is intended to guide architects and designers on how to retrofit existing wall assemblies without creating durability issues.

Desjarlais, Andre Omer↗

Hygrothermal simulation of exterior retrofits in a cold climate

This work presents results from moisture modeling as part of a project undertaken by Pacific Northwest National Laboratory and its research partners, the University of Minnesota, and the Oak Ridge National Laboratory. The research goal is to identify exterior wall retrofit systems for cold climates that are low cost, energy efficient, and do not result in moisture durability problems. A base case wall was identified representing a typical wood frame construction, circa 1950. Retrofit options were selected based on input from industry, academia, and published work and seven options were constructed and installed at the University of Minnesota’s cold weather exposure facility in Cloquet, MN. Measurements were carried out during winter months and the data was used for model validation. Hygrothermal simulations were then carried out using WUFI (Version 6.4) in accordance with standard ANSI/ASRHAE 160-2016, Criteria for Moisture-Control Design Analysis in Buildings. Simulations were run out to three years and results show that the exterior retrofits improve thermal performance and do not negatively impact moisture durability of the existing wall.

Aldykiewicz Jr, Antonio↗

NETL's Carbon Capture Retrofit Databases

This PowerPoint presentation summarizes the recently published Carbon Capture Retrofit Databases and their supporting documents, such as user guides and studies used to inform cost and performance estimates. NETL publications used to develop slide contents include Cost of Capturing CO2 from Industrial Sources, 2022; Industrial CCRD, 2022; Eliminating the Derate of Carbon Capture Retrofits, 2023; PC CCRD, 2023; Cost and Performance of Retrofitting NGCC Units for Carbon Capture, 2023; and NGCC CCRD, 2023.

Hughes, Sydney↗

Concentrating photovoltaic retrofit for existing parabolic trough solar collectors: Design, experiments, and levelized cost of electricity

Photovoltaics and concentrating solar thermal power are two ways for generating electricity from sunlight, albeit through different methods. Parabolic trough style powerplants represent 3.6 GW of electricity production, but many of these plants are aging and being replaced with photovoltaics. An alternative option that could be employed to leverage the sunk capital cost associated with the primary optics would be the design of a pure photovoltaic retrofit working within the existing plant architecture. Here, a secondary optical concentrator is designed to use the existing primary optics of a parabolic trough type solar thermal powerplant. The design is a v-shaped secondary concentrator resulting in a predicted concentration ratio on a 20 mm wide target of 94. The concentrating photovoltaic receiver for retrofit of an RP-3 based parabolic trough has been constructed using multi-junction concentrator photovoltaic cells and experimentally demonstrated here for the first time. Calculated performance of the cells based on cell specifications should result in 31% efficiency at 85 °C. On-sun efficiencies were measured at an average value of 21% with operational temperatures between 55 and 120 °C. Levelized cost of electricity calculations predict the system to have the potential to be below 7¢/kWh based on predicted efficiencies and 13¢/kWh based on the measured values at cell costs of $5/cm 2 .

14 SOLAR ENERGY↗

Annual simulation of photovoltaic retrofits within existing parabolic trough concentrating solar powerplants

Solar power for electricity production comes from either photovoltaics or concentrating solar power plants. The former has seen rapid growth and expansion due to the rapid fall in global prices, while the latter has seen moderate growth due to ability to cheaply store thermal energy for later use. Hybridization, or combining photovoltaics with concentrating solar power represents a potential way for lowering cost while enabling long term storage. Over 5 GW of capacity exist worldwide using parabolic trough style technology for concentrating solar power which presents a unique option for optimization in the form of a photovoltaic retrofit. While it is possible to analyze the performance with detailed physics models, it is necessary to create a model that can handle simulating the plant level performance to fully understand the potential performance. Here, the first utility scale plant level model of a hybrid photovoltaic-concentrating solar power plant is developed. The model is applied to existing concentrating solar power plants around the world utilizing RP-3 mirrors without thermal energy storage to understand the impact on electricity production. Model results indicate that the photovoltaic retrofit can increase yearly electricity production by up to 30% for plants with solar multiples exceeding 1.5, and that increasing the fraction of solar energy reflected further increases the yield. The increased electrical production declines as the plant solar multiple is decreased. The minimum LCOE observed was $0.07/kWh for plants with larger solar multiple and fraction of solar energy reflected to the PV is 50% of the total aperture.

14 SOLAR ENERGY↗

Advancing insulation retrofits from flexible inexpensive lucid materials (AIR FILMs) for single-pane windows

This project focused on Advancing Insulation Retrofits from Flexible Inexpensive Lucid Materials (AIR FILMs) for Single-Pane Windows. The team developed innovative porous materials that can improve the energy efficiency of existing single-pane windows in commercial and residential buildings in two technical product categories: (1) retrofits that can be applied onto existing windowpanes and (2) manufactured windowpanes that can be installed into the existing window sash.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Colorado Residential Retrofit Energy District (CoRRED) Phase I: Final Modeling Results

Electrification of buildings and transportation coupled with increased deployment of distributed energy resources (DERs) has been identified as a key step toward meeting emissions reduction goals across the U.S. Examples of pilot projects that feature innovative, 'smart' electric neighborhoods are largely focused on new construction projects, but there is a need to address the millions of existing homes so that they too may accommodate cleaner yet variable energy production in ways that benefit both the utility grid and the homes' residents. The Colorado Residential Retrofit Energy District (CoRRED) project used building and grid co-simulation tools to model an advanced energy district demonstration in an existing residential neighborhood in Denver, Colorado, and explored how existing building and utility infrastructures can be enhanced with combinations of traditional energy-efficiency retrofit measures and integration of solar panels and other DER technologies to provide better affordability and reliability. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate. Our results clearly indicate that incorporating DERs into efficient electrification produces much bigger utility bill savings on an annual basis than efficient electrification without DERs. While electrifying a neighborhood will increase the maximum load, batteries and solar panels can reduce load during peak hours so that the community can be a net producer during peak periods. A remaining challenge is to overcome first cost barriers to implementing energy-efficiency and DER technologies, as modest utility bill savings require long payback periods that are not practical for most homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗