Search NASA⌕ Search

SEARCH · Search NASA

Results for “safety testing protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Exploring the Use of Large Immersive Display Systems in the Nuclear Industry

Large immersive display systems play a critical role in the nuclear industry by enabling advanced training, design reviews, scientific visualization, and safety simulations. These systems, such as CAVE and powerwalls, allow engineers and operators to interact with virtual nuclear environments in real-time, providing a deeper understanding of complex systems. Their ability to simulate real-world scenarios for testing and optimization in a safe, controlled environment ensures that operators and engineers can refine process, enhance safety protocols, and troubleshoot complex challenges. This article outlines key lessons learned from deploying these systems, practical insights into their applications, and considerations for future improvements, aiming to guide their broader adoption and effective use in the nuclear industry.

99 - GENERAL AND MISCELLANEOUS↗

Nuclear Rocket Facility Decommissioning Project: Controlled Explosive Demolition of Neutron Activated Shield Wall

Located in Area 25 of the Nevada Test Site (NTS), the Test Cell A (TCA) Facility was used in the early to mid-1960s for the testing of nuclear rocket engines, as part of the Nuclear Rocket Development Program, to further space travel. Nuclear rocket testing resulted in the activation of materials around the reactors and the release of fission products and fuel particles in the immediate area. Identified as Corrective Action Unit 115, the TCA facility was decontaminated and decommissioned (D&D) from December 2004 to July 2005 using the Streamlined Approach for Environmental Restoration (SAFER) process, under the ''Federal Facility Agreement and Consent Order''. The SAFER process allows environmental remediation and facility closure activities (i.e., decommissioning) to occur simultaneously provided technical decisions are made by an experienced decision maker within the site conceptual site model, identified in the Data Quality Objective process. Facility closure involved a seven-step decommissioning strategy. Key lessons learned from the project included: (1) Targeted preliminary investigation activities provided a more solid technical approach, reduced surprises and scope creep, and made the working environment safer for the D&D worker. (2) Early identification of risks and uncertainties provided opportunities for risk management and mitigation planning to address challenges and unanticipated conditions. (3) Team reviews provided an excellent mechanism to consider all aspects of the task, integrated safety into activity performance, increase team unity and ''buy-in'' and promoted innovative and time saving ideas. (4) Development of CED protocols ensured safety and control. (5) The same proven D&D strategy is now being employed on the larger ''sister'' facility, Test Cell C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dual-Readout Immunochromatographic Assay by Utilizing MnO 2 Nanoflowers as the Unique Colorimetric/Chemiluminescent Probe

Manganese dioxide nanoflowers (MnO2 NFs) were synthesized and utilized as a dual readout probe to develop a novel immunochromatographic test strip (ITS) for detecting pesticide residues using chlorpyrifos as the model analyte. MnO2 NFs-labeled antibody for chlorpyrifos was employed as the signal tracer for conducting the ITS. After 10-min competitive immunoreaction, the tracer antibody was captured by the immobilized immunogen on test line in the test strip, resulting in the accumulation of MnO2 NFs. The accumulation of MnO2 NFs led to the appearance of brown color on the test line, which could be easily observed by the naked eye as a qualitative readout. Moreover, MnO2 NFs showed a remarkably enhancing effect on the luminol-H2O2 chemiluminescent (CL) system. Unlike peroxidase-like nanomaterials, the enhancing mechanism of MnO2 NFs was based on its oxidant activity to decompose H2O2 for forming reactive oxygen species. After initiating the CL system in the test zone, strong CL signal was collected as a quantitative readout to sensitively detect chlorpyrifos. Under optimal conditions, the linear range of chlorpyrifos was 0.1–50 ng/mL with a low detection limit of 0.033 ng/mL (S/N = 3). The reliability of the dual-readout ITS was successfully demonstrated by the application on traditional Chinese medicine and environmental water samples. Due to the simultaneous rapid-qualitative and sensitive-quantitative detection, the dual-readout protocol provides a promising strategy for rapid screening and field assay on various areas such as environmental monitoring, food safety and point-of-care testing.

Ouyang, Hui↗

Mechanically induced thermal runaway severity analysis for Li-ion batteries

Thermal runaway is one of the most important safety concerns in the deployment of Li-ion batteries. For this study, we developed a standardized single-side indentation test protocol to induce an internal short-circuit. Cell voltage, temperature, and applied compressive force are monitored as a function of time. Each cell is given an observed hazard severity (OHS in five categories) modified from the EUCAR table. Meanwhile a calculated hazard severity (CHS) is obtained solely based on temperature and voltage curves. The calculation formula considers the cell temperature, rate of temperature increase, cell capacity, state of charge (SOC), voltage drop, and voltage drop rate. Each term is assigned with an appropriate weight to scale the calculated score from 0 to100. This method was applied to >100 Li-ion batteries with various SOCs and chemistries, and their OHS and CHS were displayed against SOC. The purpose is to provide battery designers, manufacturers, and end-users a clear comparison of thermal runaway severity of different batteries.

25 ENERGY STORAGE↗

SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits.

60 APPLIED LIFE SCIENCES↗

Bringing Standardized Processes in Atom-Probe Tomography: I Establishing Standardized Terminology

Defining standardized methods requires careful consideration of the entire field and its applications. The International Field Emission Society (IFES) has elected a Standards Committee, whose task is to determine the needed steps to establish atom-probe tomography as an accepted metrology technique. Specific tasks include developing protocols or standards for: terminology and nomenclature; metrology and instrumentation, including specifications for reference materials; test methodologies; modeling and simulations; and science-based health, safety, and environmental practices. The Committee is currently working on defining terminology related to atom-probe tomography with the goal to include terms into a document published by the International Organization for Standards (ISO). A lot of terms also used in other disciplines have already been defined) and will be discussed for adoption in the context of atom-probe tomography.

47 OTHER INSTRUMENTATION↗

A status review of photovoltaic power conversion equipment reliability, safety, and quality assurance protocols

Data indicate that the inverter is the element of the photovoltaic plant that has the highest number of service calls and the greatest operation and maintenance cost burden. This paper describes the projects and relevant background needed in developing design qualification standards that would serve to establish a minimum level of reliability, along with a review of photovoltaic inverter quality and safety standards, most of which are in their infancy. We compare stresses and levels for accelerated testing of inverters proposed in the standard drafts, and those proposed by manufacturers and purchasers of inverters. We also review bases for the methods, stress types, and stress levels for durability testing of key inverter components. Many of the test protocols appear to need more comprehensive inclusion of stress factors existing in the natural environment such as wind driven rain, dust, and grid disturbances. Further understanding of how temperature, humidity ingress, and voltage bias affect the inverters and their components is also required. We provide data indicating inconsistent quality of the inverters and the durability of components leading to greater cost for the photovoltaic plant operator. Accordingly, the recommendation for data collection within quality standards for obtaining cost of ownership metrics is made. Design validation testing using realistic operation, environmental, and connection conditions, including under end-use field conditions with feedback for continuous improvement is recommended for inclusion within a quality standard.

14 SOLAR ENERGY↗

Testing Protocol for Module Encapsulant Creep (Presentation)

Recently there has been an interest in the use of thermoplastic encapsulant materials in photovoltaic modules to replace chemically crosslinked materials, e.g., ethylene-vinyl acetate. The related motivations include the desire to: reduce lamination time or temperature; use less moisture-permeable materials; or use materials with better corrosion characteristics. However, the use of anythermoplastic material in a high-temperature environment raises safety and performance concerns, as the standardized tests currently do not expose the modules to temperatures in excess of 85C, yet modules may experience temperatures above 100C in operation. Here we constructed eight pairs of crystalline-silicon modules and eight pairs of glass/encapsulation/glass mock modules using differentencapsulation materials of which only two were designed to chemically crosslink. One module set was exposed outdoors with insulation on the back side in Arizona in the summer, and an identical set was exposed in environmental chambers. High precision creep measurements and performance measurements indicate that despite many of these polymeric materials being in the melt state at some of thehighest outdoor temperatures achievable, very little creep was seen because of their high viscosity, temperature heterogeneity across the modules, and in the case of the crystalline-silicon modules, the physical restraint of the backsheet. These findings have very important implications for the development of IEC and UL qualification and safety standards, and in regards to the necessary level ofcure during the processing of crosslinking encapsulants.

14 SOLAR ENERGY↗

PBX 9404 detonation copper cylinder tests: a comparison of new and aged material

We present detonation copper cylinder test results on aged PBX 9404 (94 wt% HMX, 3 wt% CEF, 2.9 wt% NC, 0.1 wt% DPA) explosive. The charges were newly pressed from 37.5 year-old molding powder. We compare these results to equivalent data performed on the same lot when it was 3.5 years old. Comparison of the detonation energy inferred from detonation speed to that inferred from wall motion suggests that the HMX energy is unchanged but the NC energy has decreased to {approx}25% of its original value. The degradation of explosives and their binders is a subject of continual interest. Secondary explosives such as HMX are sufficiently stable near room temperature that they do not measurably degrade over a period of at least several decades. For formulated systems the bigger concern is binder degradation, for which the three main issues are strength, initiation safety, and (if the binder is energetic) energy content. In this paper we examine the detonation energy of new and aged PBX 9404 (94 wt% HMX, 3 wt% tris-{beta} chloroethylphosphate (CEF), 2.9 wt% nitrocellulose (NC), 0.1 wt% diphenylamine (DPA) [1, 2]), measured via the detonation copper cylinder test. In 1959, two independent PBX 9404 accidents [3] raised serious concerns about the safety of the formulation. Over about a decade's time, Los Alamos pursued a safer, energetically equivalent replacement, which ultimately became PBX 9501. In order to accurately compare the performance of the PBX 9404 and PBX 9501 formulations, W. Campbell and R. Engelke (C & E) developed a stringent cylinder test protocol that they called the Los Alamos Precision Cylinder Test [4]. The present aging study is possible because excellent PBX 9404 data from those qualification tests endures.

66↗

PACT Module Design Acceptance Criteria (Industry)

For the PACT center to both develop testing protocols and provide service to the metal halide perovskite (MHP) PV community, PACT will seek modules (mini and full-sized) for testing purposes. To ensure both safety and high-quality samples PACT publishes acceptance criteria to define the minimum characteristics of modules the center will accept for testing. These criteria help to ensure we are accepting technologies that are compatible with our technical facilities and testing equipment and can transition to large scale commercial manufacturing. This module design acceptance criteria document is for industry partners and is different from the acceptance criteria for research partners (academia, national laboratories) partners.

14 SOLAR ENERGY↗

PACT Module Design Acceptance Criteria (Research)

For the PACT center to both develop testing protocols and provide service to the metal halide perovskite (MHP) PV community, PACT will seek modules (mini and full-sized) for testing purposes. To ensure both safety and high-quality samples PACT publishes acceptance criteria to define the minimum characteristics of modules the center will accept for testing. These criteria help to ensure we are accepting technologies that are compatible with our technical facilities and testing equipment and can transition to large scale commercial manufacturing. This module design acceptance criteria document is for research partners (academia, national laboratories) and is different from the acceptance criteria for industry partners.

36 MATERIALS SCIENCE↗

Battery Testing FY 2017 Annual Progress Report

Abuse tests are designed to determine the safe operating limits of HEV\PHEV energy storage devices. Testing is intended to achieve certain worst-case scenarios to yield quantitative data on cell\module\pack response, allowing for failure mode determination and guiding developers toward improved materials and designs. Standard abuse tests with defined start and end conditions are performed on all devices to provide comparison between technologies. New tests and protocols are developed and evaluated to more closely simulate real-world failure conditions. When scaling from cell to the battery level, a detailed understanding of cell interactions provides insight on safety performance. Single point failures from a cell or group of cells can be initiated by a number of triggers including internal short circuit, misuse or abuse, or component failure at the battery or system level. Propagation of a single failure event (regardless of the initiation trigger) through an entire battery, system, or vehicle is an unacceptable outcome with regards to EV battery safety. In this FY, our work has focused on evaluating the propagation of a single cell thermal runaway event through a battery using a variety of design considerations with an emphasis on passive thermal management impacts. This has been coupled with thermal modeling by NREL for these testing conditions. In addition, alternative failure initiation methods have been evaluated to provide direct comparisons of possible energy injection between modes. This data was compiled to better identify what propagation test method is appropriate given certain battery designs. Expanding the analysis of short circuit current during failure propagation has been done for EV relevant chemistries. Ongoing test development and validation to obtain these values has been achieved. While robust mechanical models for vehicles and vehicle components exist, there is a gap for mechanical modeling of EV batteries. The challenge with developing a mechanical model for a battery is the heterogeneous nature of the materials and components (polymers, metals, metal oxides, liquids). Our work will provide empirical data on the mechanical behavior of batteries under compressive load to understand how a battery may behave in a vehicle crash scenario. This work is performed in collaboration with the U.S. Council for Automotive Research (USCAR) and Computer Aided Engineering of Batteries (CAEBAT). These programs have supported the design and development of a drop tower testing apparatus to close the gap between cell/string level testing and full scale crash testing with true dynamic rate effects.

25 ENERGY STORAGE↗

Extreme Fast Charging: Effect of Positive Electrode Material on Crosstalk

Extreme fast charging (XFC) is a key requirement for the adoption of battery-based electric vehicles by the transportation sector. However, XFC has been shown to accelerate degradation, causing the capacity, life, and safety of batteries to deteriorate. We tested cells containing five positive electrode chemistries, LFP (olivine structure), LMO (spinel), LCO (layered), NMC811 (layered) and NCA (layered), using fast-charging protocols. After testing, the negative electrodes from cells containing positive electrodes crystallizing with a layered structure were found to have more lithium deposited on their surfaces. Further, those crystallizing with a layered structure also tended to have a larger increase in impedance than those crystallizing with a spinel or olivine structure. Characterization of the negative electrodes by X-ray photoelectron spectroscopy showed that using the concentrations of LiF and Li x PO y F z as metrics, the concentration of LiF in the SEI from the cell with different positive electrodes is LFP > LMO > LCO ~ NMC811 > NCA; and for Li x PO y F z , the order is LMO > LFP > NCA > NMC811 > LCO. Clearly, the positive-electrode material was influencing the amounts of these materials formed.

25 ENERGY STORAGE↗

Is Hyalella azteca a Suitable Model Leaf-Shredding Benthic Crustacean for Testing the Toxicity of Sediment-Associated Metals in Europe?

The leaf-shredding crustacean Hyalella azteca, which is indigenous to Northern and Central America, is used to assess environmental risks associated with (metal-)contaminated sediments and to propose sediment quality standards also in Europe. Yet, it is unknown if H. azteca is protective for European crustacean shredders. We thus compared the sensitivity of H. azteca with that of the European species Asellus aquaticus and Gammarus fossarum towards copper- and cadmium-contaminated sediments (prepared according to OECD 218) under laboratory conditions employing mortality and leaf consumption as endpoints. H. azteca either reacted approximately fourfold more sensitive than the most tolerant tested species (as for cadmium) or its sensitivity was only 1.6 times lower than the highest sensitivity determined (as for copper), which should be covered by safety factors applied during risk assessments. Therefore, the results for the sediment type and the two heavy metals tested during the present study in combination with the existence of standardized testing protocols, their ease of culture, and short generation time, suggest H. azteca as suitable crustacean model shredder for assessing the toxicity of sediment-associated metals in Europe.

54 ENVIRONMENTAL SCIENCES↗

Dataset of mechanically induced thermal runaway measurement and severity level on Li-ion batteries

The deployment of Li-ion batteries covers a wide range of energy storage applications, from mobile phones, e-bikes, electric vehicles (EV) and stationary energy storage systems. However, safety issue such as thermal runaway is always one of the most important concerns to prevent Li-ion batteries from further market penetration. A standardized single-side indentation test protocol was developed to mechanically induce an internal short-circuit. The cell voltage, compressive load, indenter stroke, and temperature at the indentation point are measured in time series. The test data of each cell, along with cell parameters such as dimensions, mass, chemistry, state of charge (SOC), capacity, are integrated together to calculate a thermal runaway severity score from 0 to100. Complete data collection process including the original measured record, test method, severity score calculation scheme is presented in this article. The thermal runaway severity analysis and the more than 100 tested Li-ion battery records provide a good data source for further comparison and ranking of thermal runaway risks.

25 ENERGY STORAGE↗

CNG Cylinder Safety - Education, Outreach, and Next Steps (Presentation)

Mr. Schroeder discussed the work that NREL is performing for the U.S. Department of Transportation on compressed natural gas cylinder end-of-life requirements. CNG vehicles are different from most other vehicles in that the CNG fuel storage cylinders have a pre-determined lifetime that may be shorter than the expected life of the vehicle. The end-of-life date for a cylinder is based on construction and test protocols, and is specific to the construction and material of each cylinder. The end-of-life date is important because it provides a safe margin of error against catastrophic cylinder failure or rupture. The end-of-life dates range from 15 to 25 years from the date of manufacture. NREL worked to develop outreach materials to increase awareness of cylinder end-of-life dates, has provided technical support for individual efforts related to cylinder safety and removal, and also worked with CVEF to document best practices for cylinder removal or inspection after an accident. Mr. Smith discussed the engagement of the DOE Clean Fleets Partners, which were surveyed to identify best practices on managing cylinder inventories and approached to provide initial data on cylinder age in a fleet environment. Both DOE and NREL will continue to engage these fleets and other stakeholders to determine how to best address this issue moving forward.

03 NATURAL GAS↗

Draft Electric Rule 21 Test Protocols for Advanced Inverter Functions

Disclaimer: The following document includes draft certification protocols and should not be viewed as a consensus-based performance standard. Distributed energy resources (DERs), such as photovoltaic (PV) systems, when deployed in a large scale, are capable of significantly influencing the operation of bulk and local power systems. Looking to the future, European and American stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. One of the jurisdictions considering modifications to the DER interconnection requirements is California. To determine what changes could improve electric grid reliability and allow greater penetrations of renewable energy, the California Public Utilities Commission (CPUC) and the California Energy Commission (CEC), in conjunction with consultant Frances Cleveland, convened the Smart Inverter Working Group (SIWG) in January 2013. The SIWG--composed of state agencies, utility engineers, national laboratories, manufacturers, trade associations, and advocacy groups--provided the CPUC a set of recommendations in early 2014 1 . The recommendations included specific advanced DER functions and interoperability requirements, along with a proposed timeline, for California to add new capabilities to grid-interconnected DER. On August 18, 2014 the three California Investor-Owned Utilities (IOUs)--Pacific Gas and Electric Company (PG&E), Southern California Edison Company (SCE) and San Diego Gas & Electric Company (SDG&E)--drafted a Advice Letter filing to the CPUC setting forth revisions to Electric Tariff Rule 21 to conform to the seven recommendations made by the Working Group 2 . After a comment period, the CPUC issued an update to the IOU recommendations 3 . At the time of this publication, there was no final legal ruling on the CPUC Rulemaking (R.) 11-09-011 ("Order Instituting Rulemaking on the Commission's Own Motion to improve distribution level interconnection rules and regulations for certain classes of electric generators and electric storage resources"). In the U.S., Nationally Recognized Test Laboratories (NRTLs) independently verify products to safety and functional standards. PV inverters are certified to Underwriters Laboratories (UL) Standard 1741 4 . However, new advanced inverter functions described in the SIWG and IOU proposals are not included in this standard, so there is a critical need to develop test protocols for these functions in preparation of a positive ruling by the CPUC. Through a California Solar Initiative Grant, Sandia National Laboratories (Sandia or SNL), Underwriters Laboratories (UL), Electric Power Research Institute, Inc. (EPRI), Xanthus Consulting, SunSpec Alliance, Loggerware, and utility and PV inverter manufacturers have collaborated to draft this certification protocol for the Rule 21 SIWG Phase 1 advanced inverter functions. This report also includes test procedures for Phase 2 and Phase 3 functions that will be demonstrated later in the CSI4 project. This collaborative effort was performed in close junction with the UL 1741 Standards Technical Panel (STP) working group. This document represents a snapshot of the draft testing protocols at the time of publication and not a consensus certification protocol for advanced inverters. 1 California Public Utilities Commission, "Recommendations for Updating the Technical Requirements for Inverters in Distributed Energy Resources, Smart Inverter Working Group Recommendations," Filed 7 Feb 2014. 2 J.J. Newlander, R.G. Litteneker, S.W. Walter, M. Dwyer, Joint motion of Pacific Gas and Electric Company (U 39 E), Southern California Edison Company (U 338 E) and San Diego Gas & Electric Company (U 902 E) regarding implementation of smart inverter functionalities, Rulemaking 11-09-011 Advice Letter, 18 July, 2014. 3 J.T. Sullivan, CPUC Rulemaking 11-09-011 Agenda ID #13460, 13 Nov, 2014. 4 Underwriters Laboratories Std. 1741 Ed. 2, "Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources," 2010.

42 ENGINEERING↗

Final Report for the Contractor Readiness Assessment of the Transient Reactor Test Facility Resumption of Transient Testing Activity at the Idaho National Laboratory

The purpose of this review was to verify readiness for the TREAT restart of transient testing activity at the INL and inform the startup authorization authority decision-making for startup authorization by providing a deliberate and managed determination of the state of readiness preparation and determination of whether operations can be performed safely. Verification of readiness included assuring that equipment operability, procedure viability, and personnel knowledge, skills, and performance are adequate for operations. Because the TREAT (including restart of transient testing activity) is a hazard category-2 nuclear facility and because reactor operation and transient testing activities were suspended for programmatic and funding reasons in excess of a year, DOE O 425.1D required that both a contractor and DOE RA be satisfactorily completed prior to startup of the TREAT and restart of transient testing activity. To this end, DOE directed that a CRA and federal RA be conducted. The CRA IP defined the depth of the CRA through the objectives and CRADs, delineated in Appendix A of the IP; established roles and responsibilities for CRA team activities; and established processes, practices, and protocols for preparation, conduct, documentation, and reporting of the CRA. The approaches and methodologies identified in the IP were used to verify that the BEA management team has established SSCs, developed personnel capabilities and competencies, and implemented safety features, programs, and procedures in a manner that provides reasonable assurance for adequate protection of workers, the public, and the environment in preparation for and execution of the TREAT restart of transient testing activity. This CRA was intended to confirm that (1) the facility is in a state of readiness to safely conduct operations in accordance with the safety basis; and (2) the management control programs are in place to ensure safe operations can be sustained. This equated to mature implementation of the integrated safety management (ISM) in conjunction with implementation of the individual facility authorization basis. This CRA was structured to verify the readiness to conduct restart of transient testing activity safely, and that facility programs were in place to support the restart of transient testing activity.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗