Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Characterization Data Package for Containerized Sludge Samples Collected from Engineered Container SCS-CON-210

This data package contains the K Basin sludge characterization results obtained by Pacific Northwest National Laboratory during processing and analysis of four sludge core samples collected from Engineered Container SCS-CON-210 in 2010 as requested by CH2M Hill Plateau Remediation Company. Sample processing requirements, analytes of interest, detection limits, and quality control sample requirements are defined in the KBC-33786, Rev. 2. The core processing scope included reconstitution of a sludge core sample distributed among four to six 4-L polypropylene bottles into a single container. The reconstituted core sample was then mixed and subsampled to support a variety of characterization activities. Additional core sludge subsamples were combined to prepare a container composite. The container composite was fractionated by wet sieving through a 2,000 micron mesh and a 500-micron mesh sieve. Each sieve fraction was sampled to support a suite of analyses. The core composite analysis scope included density determination, radioisotope analysis, and metals analysis, including the Waste Isolation Pilot Plant Hazardous Waste Facility Permit metals (with the exception of mercury). The container composite analysis included most of the core composite analysis scope plus particle size distribution, particle density, rheology, and crystalline phase identification. A summary of the received samples, core sample reconstitution and subsampling activities, container composite preparation and subsampling activities, physical properties, and analytical results are presented. Supporting data and documentation are provided in the appendices. There were no cases of sample or data loss and all of the available samples and data are reported as required by the Quality Assurance Project Plan/Sampling and Analysis Plan.

core sampling↗

The Scientific Value of Collecting Samples From the Jezero Crater Rim

The Mars 2020 mission has been conducting ground-based investigation of the geology, habitability, and biosignature preservation potential and collecting samples for return to Earth in Jezero crater, Mars for nearly 3 years. Analysis of these samples will address outstanding questions in Mars science including potential habitability and how and why the climate the interior of the planet evolved through time. As of December 2023, samples of 4 igneous rocks of the Jezero crater floor and 9 sedimentary rocks of the Jezero fan and inner margin, remain on the rover. 15 tubes remain to be filled to enhance the diversity of the cache and broaden the scope of the science questions that can be addressed with returned sample studies. The next step in the mission is to explore the Jezero crater rim. It will be imperative to investigate and sample the diversity of crater rim rocks because they represent materials from Mars’ most ancient crust older than those sampled in Jezero crater, a diversity of geologic processes, and potential ancient habitable environments that have not yet been investigated or sampled. Ongoing mapping efforts are using orbiter data and long-distance images from Perseverance to identify and interpret the geologic context of the crater rim. Building on this effort and the broader geologic context for the crater rim put forward by previous studies, we identify diverse targets for in situ investigation and potential sampling by Mars 2020.

Mars sample return↗

Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

Davis, Morgan P.↗

Extravehicular Activity Asteroid Exploration and Sample Collection Capability

NASA's Asteroid Redirect Crewed Mission (ARCM) is challenged with primary mission objectives of demonstrating deep space Extravehicular Activity (EVA) and tools, and obtaining asteroid samples to return to Earth for further study. Although the Modified Advanced Crew Escape Suit (MACES) is used for the EVAs, it has limited mobility which increases fatigue and decreases the crews' capability to perform EVA tasks. Furthermore, previous Shuttle and International Space Station (ISS) spacewalks have benefited from EVA interfaces which have been designed and manufactured on Earth. Rigid structurally mounted handrails, and tools with customized interfaces and restraints optimize EVA performance. For ARCM, some vehicle interfaces and tools can leverage heritage designs and experience. However, when the crew ventures onto an asteroid capture bag to explore the asteroid and collect rock samples, EVA complexity increases due to the uncertainty of the asteroid properties. The variability of rock size, shape and composition, as well as bunching of the fabric bag will complicate EVA translation, tool restraint and body stabilization. The unknown asteroid hardness and brittleness will complicate tool use. The rock surface will introduce added safety concerns for cut gloves and debris control. Feasible solutions to meet ARCM EVA objectives were identified using experience gained during Apollo, Shuttle, and ISS EVAs, terrestrial mountaineering practices, NASA Extreme Environment Mission Operations (NEEMO) 16 mission, and during Neutral Buoyancy Laboratory testing in the MACES suit. The proposed concept utilizes expandable booms and integrated features of the asteroid capture bag to position and restrain the crew at the asteroid worksite. These methods enable the capability to perform both finesse, and high load tasks necessary to collect samples for scientific characterization of the asteroid. This paper will explore the design trade space and options that were examined for EVA, the overall concept for the EVAs including translation paths and body restraint methods, potential tools used to extract the samples, design implications for the Asteroid Redirect Vehicle (ARV) for EVA, the results of early development testing of potential EVA tasks, and extensibility of the EVA architecture to NASA's exploration missions.

Scoville, Zebulon↗

Analysis of Dust Samples Collected from a Near-Marine East Coast ISFSI Site ("Site C")

In June of 2022, dust samples were collected from the surface of an in-service spent nuclear fuel dry storage canister during an inspection at an Independent Spent Fuel Storage Installation. The site is anonymous but is a near-marine or brackish water east coast location referred to here as "Site C". The purpose of the sampling was to assess the composition and abundance of the soluble salts present on the canister surface, information that provides a metric for potential corrosion risks. Following collection, the samples were delivered to Sandia National Laboratories for analysis. At Sandia, the soluble salts were leached from the dust and quantified by ion chromatography. In addition, subsamples of the dust were taken for scanning electron microscopy to determine the particle sizes, morphology, and mineralogy of the dust and salts. The results of those analyses are presented in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Dust Samples Collected from an In-Service Interim Storage System at the Maine Yankee Nuclear Site.

In July, 2016, the Electric Power Research Institute and industry partners performed a field test at the Maine Yankee Nuclear Site, located near Wiscasset, Maine. The primary goal of the field test was to evaluate the use of robots in surveying the surface of an in-service interim storage canister within an overpack; however, as part of the demonstration, dust and soluble salt samples were collected from horizontal surfaces within the interim storage system. The storage system is a vertical system made by NAC International, consisting of a steel-lined concrete overpack containing a 304 stainless steel (SS) welded storage canister. The canister did not contain spent fuel but rather greater-than-class-C waste, which did not generate significant heat, limiting airflow through the storage system. The surfaces that were sampled for deposits included the top of the shield plug, the side of the canister, and a shelf at the bottom of the overpack, just below the level of the pillar on which the canister sits. The samples were sent to Sandia National Laboratories for analysis. This report summarizes the results of those analyses. Because the primary goal of the field test was to evaluate the use of robots in surveying the surface of the canister within the overpack, collection of dust samples was carried out in a qualitative fashion, using paper filters and sponges as the sampling media. The sampling focused mostly on determining the composition of soluble salts present in the dust. It was anticipated that a wet substrate would more effectively extract soluble salts from the surface that was sampled, so both the sponges and the filter paper were wetted prior to being applied to the surface of the metal. Sampling was accomplished by simply pressing the damp substrate against the metal surface for two minutes, and then removing it. It is unlikely that the sampling method quantitatively collected dust or salts from the metal surface; however, both substrates did extract a significant amount of material. The paper filters collected both particles, trapped within the cellulose fibers of the filter, and salts, while the sponges collected only the soluble salts, with very few particles. Upon delivery to Sandia, both collection media were analyzed using the same methods. The soluble salts were leached from the substrates and analyzed via ion chromatography, and insoluble minerals were analyzed by scanning electron microscopy and energy dispersive X-ray spectroscopy. The insoluble minerals were found to consist largely of terrestrially-derived mineral fragments, dominantly quartz and biotite. Large (mm-sized) aggregates of calcium carbonate, calcium silicate, and calcium aluminum silicate were also present. The aggregates had one flat, smooth surface and one well crystallized surface, and were interpreted to be efflorescence on the inside of the overpack and in the vent, formed by seepage of cement pore fluids through joints in the steel liner of the overpack. Such efflorescence was commonly observed during the boroscope inspection of the storage system at the site. The material may have flaked off and fallen to the point where the dust was collected, or may have brushed off onto the sponges when the robot was retrieved through the inlet vent. Chemical analysis showed that the soluble salts on the shield plug were Ca- and Na-rich, with lesser K and minor Mg; the anionic component was dominated by SO 4 and Cl, with minor amounts of NO 3 . The cation composition of the soluble salts from the overpack shelf and the canister surface was similar to the filter samples, but the anions differed significantly, being dominantly NO 3 with lesser Cl and only trace SO 4 . The salts appear to represent a mixture of sea-salts (probably partially converted to nitrates and sulfates by particle-gas conversion reactions) and continental salt aerosols. Ammonium, a common component in continental aerosols, was not observed and may have been lost by degassing from the canister surface or after collection during sample storage and transportation. The demonstration at Maine Yankee has shown that the robot and sampling method used for the test can successfully be used to collect soluble salts from metal surfaces within an interim storage system overpack. The results were consistent from sample to sample, suggesting that a representative sample of the soluble salts was being collected. However, it is unlikely that the salt samples collected here represent quantitative sampling of the salts on the surfaces evaluated; for that reason, chloride densities per unit area are not presented here. It should also be noted that the relevance to storage systems at the site that contain SNF may be limited, because a heat- generating canister will result in greater airflow through the overpack, affecting dust deposition rates and possibly salt compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Case Study: Systems Analysis of Y-12 Waste Sample Collection

The Environmental Management Organization has established a 90-Day Goal for characterizing, packaging, and dispositioning all waste after it has been declared. If adequate process knowledge is not available, a waste sample must be collected and analyzed. The objective of this case study is to reduce the cycle time for waste sample collection from 14.5 calendar days to 10 calendar days 95% of the time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Dust Samples Collected from an Inland ISFSI Site (Site A)

In September of 2020, dust samples were collected from the surface of spent nuclear fuel (SNF) dry storage canisters during an inspection at an inland Independent Spent Fuel Storage Installation. The purpose of the sampling was to assess the composition and abundance of the soluble salts present on the canister surface, information which provides a metric for potential corrosion risks. The samples were delivered to Sandia National laboratories for analysis. At Sandia, the soluble salts were leached from the dust and quantified by ion chromatography. In addition, subsamples of the dust were taken for scanning electron microscope analysis to determine the texture and mineralogy of the dust and salts. The results of those analyses are presented in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of water samples collected during LANDSAT-1 overpasses of the lower Chesapeake Bay area

Water samples were collected on 18 days when the LANDSAT-1 satellite was passing over the lower Chesapeake Bay area. A correlation between the various water parameters has been performed for the more than 300 surface samples. Six days were sufficiently cloudless that MSS digital tapes were useful for analysis. Correlation of radiance values with the water parameters revealed a low correlation for chlorophyll and good correlations with particles and sediment. The relation of total particles to sediment was linear, but varied from day to day.

Bowker, D. E.↗

Water sample-collection and distribution system

Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

Brooks, R. R.↗

Analysis of Dust Samples Collected from an Inland ISFSI Site (''Site B'').

In October of 2020, dust samples were collected from the surface of spent nuclear fuel (SNF) dry storage canisters during an inspection at an inland Independent Spent Fuel Storage Installation, the second inland site at which surface deposits have been sampled. The purpose of the sampling was to assess the composition and abundance of the soluble salts present on the canister surface, information which provides a metric for potential corrosion risks. The samples were delivered to Sandia National laboratories for analysis. At Sandia, the soluble salts were leached from the dust and quantified by ion chromatography. In addition, subsamples of the dust were taken for scanning electron microscopy to determine the texture and mineralogy of the dust and salts. The results of those analyses are presented in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

As codified in NASA Policy Directive 7100.10F, the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. JSC Curation curates all or part of nine astromaterial collections in seven clean room suites: (1) Apollo Samples (1969; ISO 6-7), (2) Luna Samples (from USSR; 1972; ISO 7), (3) Antarctic Meteorites (1976; ISO 7), (4) Cosmic Dust (1981; ISO 5), (5) Microparticle Impact Collection (formerly called Space Exposed Hardware; 1985; ISO 5), (6) Genesis Solar Wind Atoms (2004; ISO 4); (7) Stardust Comet Particles (2006; ISO 5), (8) Stardust Interstellar Particles (2006; ISO 5), (9) Hayabusa Asteroid Particles (from JAXA; 2010; ISO 5). In addition to the labs that house the samples, we have installed and maintained a wide variety of facilities and infrastructure required to support the clean-rooms: more than 10 different HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system (UPW) and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam (FIB) sections to meet the research requirements of scientists. To ensure that we are keeping the samples as pristine as possible, we routinely monitor the cleanliness of our clean rooms and infrastructure systems. This monitoring includes: daily monitoring of the quality of our UPW, weekly airborne particle counts in the labs, monthly monitoring of the stable isotope composition of the gaseous N2 system, and annual measurements of inorganic or organic contamination in processing cabinets. We track within our databases the current and ever-changing characteristics of more than 250,000 individual samples across our various collections (including the 19,141 samples on loan to 433 Principal Investigators in 24 countries). The next sample return missions that NASA will participate in are Hayabusa2 and OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security - Regolith Explorer). The designs for a new state-of-the-art suite of clean rooms to house these samples at JSC have been finalized. This includes separate ISO class 5 clean rooms to house each collection, a common ISO class 7 area for general use, an ISO class 7 microtome laboratory, and a separate thin section lab. Additionally, a new cleaning facility is being designed and procedures developed that will allow for enhanced cleaning of cabinets and tools in an inorganically, organically, and biologically clean manner. We are also designing a large multi-purpose Advanced Curation laboratory that will allow us to develop the techniques necessary to fully support the Hayabusa2 and OSIRIS-REx missions, as well as future possible sample return missions (e.g., Lunar Polar Volatiles, Mars, Comet Surface). A micro-CT (micro Computed Tomography) laboratory dedicated to the study of astromaterials has come online within JSC Curation, and we plan to add additional facilities that will enable non-destructive (or minimally-destructive) analyses of astromaterials in the near future (e.g., micro-XRF (micro X-Ray Fluorescence), confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions, (2) be utilized by PET (Positron Emission Tomography) for future sample return missions, (3) for retroactive PET-style analyses of our existing collections, and (4) for periodic assessments of the existing sample collections.

Zeigler, Ryan A.↗

Wipe Sampling Collection Efficiencies and Holding Time Studies

Despite the fact that wipe sampling is commonly performed and the data produced by this technique is used to make numerous decisions, there is not an overwhelming consensus on the best method for collecting a wipe sample. It is generally agreed that, in order to produce reproducible quantitative results, consistent wetting solvents, wipe materials, sampling techniques, and sampling areas must be used. In addition, wetting solvents should be selected with consideration of the analyte of interest and wet wipes are better than dry wipes for the collection of organic chemicals. Thus, the goal of the Lawrence Livermore National Laboratory (LLNL) study was to understand factors affecting wipe sampling for specific chemical warfare agents (CWAs), including sarin (GB), soman (GD), cyclosarin (GF), distilled sulfur mustard (HD), and O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate (VX), and the pesticides diazinon and malathion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DISTRIBUTION COEFICIENTS (KD) GENERATED FROM A CORE SAMPLE COLLECTED FROM THE SALTSTONE DISPOSAL FACILITY

Core samples originating from Vault 4, Cell E of the Saltstone Disposal Facility (SDF) were collected in September of 2008 (Hansen and Crawford 2009, Smith 2008) and sent to SRNL to measure chemical and physical properties of the material including visual uniformity, mineralogy, microstructure, density, porosity, distribution coefficients (K{sub d}), and chemical composition. Some data from these experiments have been reported (Cozzi and Duncan 2010). In this study, leaching experiments were conducted with a single core sample under conditions that are representative of saltstone performance. In separate experiments, reducing and oxidizing environments were targeted to obtain solubility and Kd values from the measurable species identified in the solid and aqueous leachate. This study was designed to provide insight into how readily species immobilized in saltstone will leach from the saltstone under oxidizing conditions simulating the edge of a saltstone monolith and under reducing conditions, targeting conditions within the saltstone monolith. Core samples were taken from saltstone poured in December of 2007 giving a cure time of nine months in the cell and a total of thirty months before leaching experiments began in June 2010. The saltstone from Vault 4, Cell E is comprised of blast furnace slag, class F fly ash, portland cement, and Deliquification, Dissolution, and Adjustment (DDA) Batch 2 salt solution. The salt solution was previously analyzed from a sample of Tank 50 salt solution and characterized in the 4QCY07 Waste Acceptance Criteria (WAC) report (Zeigler and Bibler 2009). Subsequent to Tank 50 analysis, additional solution was added to the tank solution from the Effluent Treatment Project as well as from inleakage from Tank 50 pump bearings (Cozzi and Duncan 2010). Core samples were taken from three locations and at three depths at each location using a two-inch diameter concrete coring bit (1-1, 1-2, 1-3; 2-1, 2-2, 2-3; 3-1, 3-2, 3-3) (Hansen and Crawford 2009). Leaching experiments were conducted with a section of core sample 3-2. All cores from location 3 were drilled without using water. Core sample 3-2 was drilled from approximately six inches to a depth of approximately 13 inches. Approximately six inches of the core was removed but it broke into two pieces during removal from the bit. At the time of drilling, core material appeared olive green in color (Smith 2008). The fact that the samples were cored as olive green and were received after storage with a gray outer layer is indicative that some oxidation had occurred prior to leaching studies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assembly for collecting samples for purposes of identification or analysis and method of use

An assembly and an associated method for collecting a sample of material desired to be characterized with diagnostic equipment includes or utilizes an elongated member having a proximal end with which the assembly is manipulated by a user and a distal end. In addition, a collection tip which is capable of being placed into contact with the material to be characterized is supported upon the distal end. The collection tip includes a body of chemically-inert porous material for binding a sample of material when the tip is placed into contact with the material and thereby holds the sample of material for subsequent introduction to the diagnostic equipment.

Thompson, Cyril V↗

Sample Collection from Small Airless Bodies: Examination of Temperature Constraints for the TGIP Sample Collector for the Hera Near-Earth Asteroid Sample Return Mission

There have been a number of missions that have explored the solar system with cameras and other instruments but profound questions remain that can only be addressed through the analysis of returned samples. However, due to lack of appropriate technology, high cost, and high risk, sample return has only recently become a feasible part of robotic solar system exploration. One specific objective of the President s new vision is that robotic exploration of the solar system should enhance human exploration as it discovers and understands the the solar system, and searches for life and resources [1]. Missions to small bodies, asteroids and comets, will partially fill the huge technological void between missions to the Moon and missions to Mars. However, such missions must be low cost and inherently simple, so they can be applied routinely to many missions. Sample return from asteroids, comets, Mars, and Jupiter s moons will be an important and natural part of the human exploration of space effort. Here we describe the collector designed for the Hera Near-Earth Asteroid Sample Return Mission. We have built a small prototype for preliminary evaluation, but expect the final collector to gather approx.100 g of sample of dust grains to centimeter sized clasts on each application to the surface of the asteroid.

Franzen, M. A.↗

Variability of collagen crosslinks: impact of sample collection period

Because of the variability of collagen crosslinks, their use as markers for bone resorption is often criticized. We hypothesized that the variability could be reduced by collecting urine for 24 hours (or longer) instead of using single voids, and by not normalizing to creatinine. Urine samples were collected from 22 healthy subjects during two or more 24-hour periods. Each 24-hour pool and each 2nd void of the day were analyzed for N-telopeptide (NTX), pyridinium (PYD), and deoxypyridinoline (DPD) crosslinks. Data were analyzed by using linear regression. For NTX, R2 for the two, 2nd-void samples (n = 38) was 0.55, whereas R2 for the two 24-hour pools was 0.51 or 0.52, expressed per day or per creatinine. For PYD and DPD, R2 for the 2nd-void samples was 0.26 and 0.18, R2 for the 24-hour pools expressed per day was 0.58 and 0.74, and R2 for the 24-hour pools expressed per creatinine was 0.65 and 0.76, respectively. Regression of the 2nd void and the corresponding 24-hour pool, expressed per day, yielded R2 = 0.19, 0.19, and 0.08, for NTX, PYD, and DPD, respectively (n = 76 each). For the 2nd-void sample and its corresponding 24-hour pool, expressed per creatinine, R2 = 0.24, 0.33, and 0.08, respectively. In a separate study, the coefficient of variation for NTX was reduced (P < 0.05) when data from more than one 24-hour collection were combined. Thus, the variability inherent in crosslink determinations can be reduced by collecting urine for longer periods. In research studies, the high variability of single-void collections, compounded by creatinine normalization, may alter or obscure findings.

Specimen Handling/methods↗