Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample sealing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Self-contained, automated, long-term sensor system for monitoring of soil and water nutrients in fields

An automated, fieldable ion-selective sensor system for frequent detection of nutrients in soils or water is set forth. In one aspect, an integrated small form-factor housing includes a battery, processor, a fluid manipulation unit and reservoirs, and a chemical species detection cell. A flow-through sampling head can be connected to the detection cell and a waste reservoir by flexible tubing sealingly connected at opposite ends of the tube. In one aspect, improved performance of the ion-selective sensor includes adding an ion-to-electron transfer interlayer between an ion-selective membrane and its working electrode. In one aspect, the sensor is solid-state and uses printed polymeric composite of POT-MoS$_{2}$. The use of a porous tube for a sampling head and fluid connection at opposite ends allows not only fluid to be removed from the head to the detection cell for measurement but also flow in an opposite direction and out to a waste reservoir to clean and reset for a next sample measurement.

60 APPLIED LIFE SCIENCES↗

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

lllinois Storage Corridor CarbonSAFE Phase III: Pre-drilling Site Assessment: Prairie State Generating Company

The Illinois Storage Corridor project will drill a stratigraphic test well as part of the Illinois Storage Corridor CarbonSAFE Phase 3 project near the Prairie State Generating Company coal-fired power plant near Marissa, Illinois. The pre-drilling site evaluation has considered the primary target reservoirs, the Potosi Dolomite and St. Peter Sandstone, and primary seal, the Maquoketa Group. Data to be collected from the well include core, fluid samples, in situ well tests, geophysical logs intended to provide information on lithologic, geomechanical, and geophysical characteristics to determine the feasibility for the geologic sequestration of 50 million metric tons or more of injected carbon dioxide. The planned drilling site has been evaluated using available subsurface geologic data and analyses from the Illinois Basin. These data provide lithologic and structural information, shallow groundwater resource distribution, location of known nearby wellbores, and regional drilling characteristics. The data were used to generate geologic structure and isopach maps for the target reservoir and caprock strata and for prognosing the tops of major lithologic units to aid drilling and coring procedures. The regional analyses indicate that no known structural features are expected to negatively impact the target storage reservoir or caprock. No protected and sensitive areas, groundwater resources, or existing resource development are expected to be impacted by the proposed well drilling activities. The well is planned to be drilled to a total depth of approximately 5,600 feet (1,707 m) and terminate in the Precambrian. Cores (up to 5 intervals) will be collected from the Maquoketa Group, confining units above the St. Peter Sandstone, St. Peter Sandstone, confining units of the Potosi Dolomite and the Potosi Dolomite. Water samples will be attempted to be collected from the St. Peter Sandstone and Potosi Dolomite. Potential impact on drilling progress is a lost circulation zone in the Potosi Dolomite, which has been demonstrated to have intermittent cavernous porosity from karstification elsewhere in the Illinois Basin. This document also presents a preliminary coring and sampling program, proposed logging suite, and well testing program, all of which will be reviewed during drilling.

01 COAL, LIGNITE, AND PEAT↗

University of Washington Harborview Research and Training Building Environmental Sample Plan for Cs-137 in Soils and Sediments

On May 2, 2019, a release of Cs-137 from a breached sealed source containing 2,800 curies (Ci) (1E14 Bq) of Cesium-137 (Cs-137) occurred at the University of Washington (UW) Harborview Research and Training Building (HRB). The release occurred during removal of the source from its holder within a portable hot cell in the second floor loading dock area. The loading dock and northeast corner of the building above the ground floor were heavily impacted by the release, while the remaining portions of the building and the exterior of the building were minimally impacted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Williston Basin Resource Study for Commercial-Scale Subsurface Hydrogen Storage

The Energy & Environmental Research Center (EERC), in partnership with the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), the EERC’s State Energy Research Center (SERC), MPLX Operations LLC, and TC Energy Development Holdings Inc. (a subsidiary of TC Energy Corporation), studied the potential for subsurface hydrogen storage and recovery in the Williston Basin of western North Dakota. The project’s goal was to evaluate the feasibility of large-scale, secure geologic H 2 storage to support future hydrogen generation, storage, and use. This work included laboratory testing, H 2 –rock–fluid exposure experiments, literature reviews on H 2 embrittlement, and reservoir modeling and simulations. The study included an assessment of storage potential across three types of storage reservoirs using both reservoir simulation and DOE’s web-based tool SHASTA-HELP (Subsurface Hydrogen Assessment, Storage, and Technology Acceleration – Hydrogen Estimator for Logistical Planning), as well as investigation of potential H 2 production and markets for commercial-scale deployment. Building on prior EERC gas storage research, three storage options were selected for detailed evaluation: the Broom Creek Formation (a clastic saline reservoir), the Dickinson Lodgepole Mounds (DLM) complex (carbonate mud mound structures) of the Lodgepole Formation (an active oil and gas producing reservoir), and the Dunham Salt Interval of the Piper Formation (to be used for engineered salt cavern development). These targets were prioritized based on prior EERC research using datasets related to seal capacity, reservoir quality, mechanical integrity, and injectivity. Exposure tests on Broom Creek and DLM samples showed mineral dissolution and precipitation that increased brine salinity and altered reservoir rock surfaces. Although these results provide useful insight, they are limited by small sample sizes and short-term (30-day) exposure, requiring further study to assess long-term storage integrity. Salt formations were not tested because of their known nonreactivity and established mechanical stability. Results of reservoir simulations performed for a single site demonstrated that the Broom Creek Formation may be capable of receiving up to 42,000 tonnes of injected H 2 over 7 months via one well. H 2 recovery took place over 5 months, resulting in approximately 26,000 tonnes (~62% without cushion gas [CG]). This work suggests water production may be important and subsequent cycles of injection and production may perform more efficiently; however, significant site-specific work in the future is needed to assess actual reservoir performance of injection and withdrawal of H 2 storage. For oil reservoir potential, a multiple-well model was used to simulate injection of approximately 32,000 tonnes of H 2 into a single wellbore while simultaneously producing in place reservoir fluids from four offset wells to maintain reservoir pressure. The simulation results suggested a high recovery (~98%); in addition, cost advantages through existing infrastructure could be realized. Challenges in this reservoir include vi managing gas purity and leakage risks. In both scenarios, production of H 2 takes place in a single-well scenario with 10 cycles (7 months of injection and 5 months of production) over 10 years. Finally, the use of engineered caverns in the Dunhan Salt was evaluated, and the results suggest that while they have a smaller capacity (<1000 tonnes per cavern), they exhibit nearly complete gas recovery (>99%), fast response times, and low purity risk. While caverns in North Dakota may be smaller in capacity, fields can be developed in galleries to accommodate the volumetric needs and rapid turnaround times necessary to meet market demands. Geographic limitations and thin salt intervals in North Dakota may represent less total storage potential than salt domes elsewhere, but significant opportunities exist to expand this market for gas storage in North Dakota. A basinwide assessment was performed to estimate a first-of-its-kind value for H 2 storage on a large scale. DOE’s SHASTA-HELP, combined with EERC simulation work, was used to perform the assessment. Estimated H 2 storage potential varied widely for each formation type. The Broom Creek saline formation was estimated to have a storage potential of approximately 1.7–90.5 million tonnes (MMt). The DLM oil reservoirs were estimated to have 0.07–0.19 MMt of capacity. Notably, each of these estimates relies on significant assumptions regarding reservoir thickness, porosity, permeability, and CG needed for operation. Much research is needed to understand the true site-specific storage resource potential of each formation. Using the Dunham Salt Interval for cavern development may result in as much as 4.79 MMt (up to 2.87 MMt working gas) of H 2 storage potential. An important note for consideration is that the values presented here need significantly more geological characterization and engineering assessments prior to gaining confidence in performance. This will be a focal point for future research and development needs. The basinwide evaluation also indicated that North Dakota has significant H 2 generation potential, with estimates up to a possible 13 MMt annually, suggesting a substantial opportunity for H 2 market development and thus the need for commercial-scale H 2 storage to facilitate growth and resilience. Key Recommendations 1. Conduct detailed site characterization (3D seismic, well logs, core sampling) to reduce geologic uncertainty. 2. Perform techno-economic analyses incorporating market, regulatory, and incentive frameworks. 3. Investigate long-term interactions among H 2 , CGs, well materials, and formations to assess risks. 4. Develop pilot- and field-scale demonstrations to validate models and establish best practices.

03 NATURAL GAS↗

Wabash CarbonSAFE. Geologic Analysis of the Potosi Dolomite Reservoir Interval and Potential Confining Units, at the Wabash #1 Well, Vigo Co., Indiana, Subtask 7.2, Technical Report

The Wabash CarbonSAFE project drilled the Wabash #1 stratigraphic test well (ID# 168045) at the Wabash Valley Resources (WVR) IGCC facility in Vigo County, Indiana, to evaluate the feasibility of commercial-scale CO 2 storage near the site. The Mt. Simon Sandstone was the initial target for storage evaluation and was found to have generally poor reservoir qualities in the Wabash #1 well. Focus was then placed on the secondary target, the Potosi Dolomite. For storage and containment evaluation an extensive suite of geophysical logs was collected throughout the borehole, and whole cores were obtained from the Mt. Simon Sandstone, Eau Claire Formation, and Maquoketa Group. The Maquoketa Group is identified as a regionally extensive secondary sealing interval above the Mt. Simon Sandstone and as a primary seal for the Potosi Dolomite storage complex. Due to concerns over potential lost circulation zones in the Potosi Dolomite during drilling, no core samples or Formation Micro Imager (FMI) logs were acquired in the Potosi Dolomite. However, cased hole well testing was performed over a 20 feet (6 m) interval within the Potosi Dolomite during which a fluid swab sample was obtained. Approximately 35 miles of 2D seismic information was acquired in the project area near Wabash #1 to aid in reservoir and caprock characterization. The highly porous and permeable zones in the Potosi Dolomite and lower Oneota Dolomite observed within the Wabash #1 well are, for the purpose of this report, considered the same reservoir package and referred to as the Potosi reservoir interval. This report presents a regional depositional context for the Potosi reservoir interval, the overlying confining zones in the Knox Group, and Maquoketa Group primary seal. This context is developed through detailed information obtained from the Wabash #1 well such as lithologic data collected from cuttings and core, geophysical logging, geomechanical analysis of core samples, and well testing and fluid sampling within the Potosi reservoir interval. Information discussed in this report was compiled as a basis for the development of static and dynamic geologic models of the Potosi Dolomite storage complex. The static and dynamic modeling of CO 2 injection in the Potosi reservoir interval are discussed in a separate report (Dessenberger et al., 2022) under the Wabash CarbonSAFE project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization of the Insoluble Solids of the 241-17F and 241-49H Pump house Water Sample

Six different water samples from 241-17F and 241-49H pump house were analyzed for chemical and physical characteristics as part of efforts to understand recent mechanical seal failures associated with four new cooling water pumps. A focus of this work was characterization of any “as found” insoluble solids. The insoluble material found in the FCRW (F-Area caustic water treated with sodium chromate at 241-17F) sample are mostly magnetite (Fe3O4 or possibly equipment rust) and silica. It was found that 26% of measured FCRW particles have at least one dimension larger than 15 microns. The insoluble particles found in the source water, domestic water (FDW), are mostly kaolin (aluminosilicate) and some iron oxide. All found FDW particles were larger than 15 microns. The insoluble particles of the other source water, FArea well water (FWW), were mostly iron oxide with some trapped cations like calcium. Only 8% of found FWW particles were bigger than 15 microns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-Phase Flow Mechanisms Controlling CO2 Intrusion into Shaly Caprock

Abstract Geologic carbon storage in deep saline aquifers has emerged as a promising technique to mitigate climate change. CO 2 is buoyant at the storage conditions and tends to float over the resident brine jeopardizing long-term containment goals. Therefore, the caprock sealing capacity is of great importance and requires detailed assessment. We perform supercritical CO 2 injection experiments on shaly caprock samples (intact caprock and fault zone) under representative subsurface conditions. We numerically simulate the experiments, satisfactorily reproducing the observed evolution trends. Simulation results highlight the dynamics of CO 2 flow through the specimens with implications to CO 2 leakage risk assessment in field practices. The large injection-induced overpressure drives CO 2 in free phase into the caprock specimens. However, the relative permeability increase following the drainage path is insufficient to provoke an effective advancement of the free-phase CO 2 . As a result, the bulk CO 2 front becomes almost immobile. This implies that the caprock sealing capacity is unlikely to be compromised by a rapid capillary breakthrough and the injected CO 2 does not penetrate deep into the caprock. In the long term, the intrinsically slow molecular diffusion appears to dominate the migration of CO 2 dissolved into brine. Nonetheless, the inherently tortuous nature of shaly caprock further holds back the diffusive flow, favoring safe underground storage of CO 2 over geological time scales.

58 GEOSCIENCES↗

Fixed-target serial crystallography at the Structural Biology Center

Serial synchrotron crystallography enables the study of protein structures under physiological temperature and reduced radiation damage by collection of data from thousands of crystals. The Structural Biology Center at Sector 19 of the Advanced Photon Source has implemented a fixed-target approach with a new 3D-printed mesh-holder optimized for sample handling. The holder immobilizes a crystal suspension or droplet emulsion on a nylon mesh, trapping and sealing a near-monolayer of crystals in its mother liquor between two thin Mylar films. Data can be rapidly collected in scan mode and analyzed in near real-time using piezoelectric linear stages assembled in an XYZ arrangement, controlled with a graphical user interface and analyzed using a high-performance computing pipeline. Here, the system was applied to two β-lactamases: a class D serine β-lactamase from Chitinophaga pinensis DSM 2588 and L1 metallo-β-lactamase from Stenotrophomonas maltophilia K279a.

59 BASIC BIOLOGICAL SCIENCES↗

Progress Update on the In Situ Load Retention Aging Vessel

To improve upon our conventional thermally accelerated aging study methods which require periodic interruption of aging to perform load testing in an Instron machine, a new aging system is being developed to: (1) automate/facilitate data acquisition/analysis, (2) improve data quality, and (3) enable uninterrupted aging conditions (compression, temperature, atmosphere) which represents the service condition. In FY24, a thermal aging vessel instrumented with load cells was fabricated and tested. That unit demonstrated the primary function of the vessel: to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary objective, not realized in the unit due to inadequate sealing, was to enable a single initial nitrogen backfill (as opposed to a continuous purge) and gas sampling of the vessel headspace during thermal aging. Heating of the vessel was achieved using a custom heater jacket.

36 MATERIALS SCIENCE↗

Carrier gas attenuation in gamma assay of radioactive xenon samples

Gamma attenuation attributable to xenon and carbon dioxide carrier gas in radioactive xenon assay samples has been calculated using Monte Carlo n-Particle (MCNP) transport code for the 0.65 mL flame sealed ampoule (bean), and 15 mL and 50 mL Schlenk tube geometries. The attenuation was correlated as a % loss per standard mL of carrier gas. In this work, high Purity Ge gamma spectroscopy experiments were performed to measure against the MCNP results. The experimental results from the 133 Xe in xenon carrier gas in a bean geometry showed 0.97 ± 0.4% loss per standard mL xenon, which was in agreement with the MCNP predictions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

On Caprock Seal Integrity of Tuscaloosa Mudstone at Cranfield, MS (USA), CO 2 Injection Site

Saline formations deep underground are among the most promising targets for large-scale geologic carbon storage. The caprock seal integrity evaluation is an important component of commercial-scale CO 2 sequestration projects. Measurements of the porosity and permeability of mudstone samples from the NETL-supported Cranfield Project were performed using a helium porosimeter and a core flow apparatus, before and after exposure in a CO 2 -saturated brine environment. The permeability of the core samples rapidly decreased with the increase in confining pressure and did not fully recover after decompression. On the other hand, exposure to CO 2 led to an increase in the permeability by at least an order of magnitude. The porosity changes after the exposure were not substantial. The post-exposure increase in permeability was subsequently offset by its rapid decrease during the higher-pressure confinement. Extrapolation of the observed permeability trends to in situ reservoir conditions suggests that Tuscaloosa mudstone can effectively serve as a natural seal.

58 GEOSCIENCES↗

Review and Summary of Corrosion Behavior for Aluminum-Clad Spent Nuclear Fuel in Dry Storage

A description of the corrosion behavior of aluminum alloys used for cladding on aluminum-based, aluminum-clad nuclear fuel used in research reactors under potential dry storage conditions has been compiled. An evaluation is made of potential additional corrosion with water postulated to not be removed during drying. The relative humidity (RH) produced by typical dryness criteria for industrial spent nuclear fuel drying is expected to be low, particularly at high temperatures (17% RH at 20°C and lower at higher temperatures). Existing corrosion data suggests that negligible vapor-phase corrosion of aluminum is expected at such low humidity, even for nominally bare aluminum surfaces. That is, the predicted relative humidity from free water (e.g., 17% RH) is below the “critical” relative humidity (~40% RH at room temperature), below which no significant corrosion is observed for bare aluminum. Furthermore, reported room-temperature corrosion rates are very low even under saturated (100% RH) water vapor. Existing results showing significant vapor-phase corrosion corresponded specifically to conditions of high temper ed with high relative humidity. A relatively large reservoir of (chemically bound) water exists in the aluminum (oxy)hydroxide films on the SNF cladding surface. The estimated total could saturate the gas even at relatively high temperature if fully released; however, its release as molecular water is expected to only be plausible if the temperature during storage exceeds both the drying temperature and the threshold for thermal decomposition of the trihydroxides (~220°C). Therefore, the combination of high temperature and high relative humidity that could drive significant corrosion is considered implausible during sealed dry storage following an appropriate drying process, to include >220°C drying for canisters that may approach or exceed this temperature during storage. Vapor-phase testing of aluminum samples with an adherent (oxy)hydroxide layer, prepared in liquid water to resemble those on actual aluminum-clad spent nuclear fuel (ASNF), did not observe evidence of additional corrosion even at combined high-temperature (up to 180°C) and high-humidity (up to 100% RH) conditions. Instead, small net mass losses were observed for most specimens and attributed to dehydration of the samples, which had been air-dried only prior to testing. ASNF being moved to dry storage is expected to have an existing (oxy)hydroxide film, suggesting that the cladding will be less prone to additional corrosion than bare aluminum metal. If significant corrosion did occur during sealed storage, the overall extent and impact is expected to be small. Corrosion post-closure of a canister would not alter the total amount of hydrogen in the canister, so it would have no effect on the maximum H 2 release already assessed in existing bounding calculations. In addition, the total amount of water in a 25-µm dense bayerite film would consume a only ~8 µm additional aluminum metal on average, if fully consumed by oxidizing aluminum metal to Al 2 O 3 . These conclusions are consistent with ASNF-in-canister simulations to date, which included a reaction pathway for corrosion using kinetics from previous literature and believed to be conservative and predicted very low rates of corrosion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Absolute quantitation of propranolol from 200-μm regions of mouse brain and liver thin tissues using laser ablation-dropletProbe-mass spectrometry

Rationale: The ability to quantify drugs and metabolites in tissue with sub-mm resolution is a challenging but much needed capability in pharmaceutical research. To fill this void, a novel surface sampling approach combining laser ablation with the commercial dropletProbe automated liquid surface sampling system (LA-dropletProbe) was developed and presented here.Methods: Parylene C-coated 200 × 200 μm tissue regions of mouse brain and kidney thin tissue sections were analyzed for propranolol by laser ablation of tissue directly into a preformed liquid junction. Propranolol was detected by high performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry. Quantitation was achieved via application of a stable isotope-labeled internal standard and an external calibration curve.Results: Absolute concentration of propranolol determined from 200 × 200 µm tissue regions were compared to propranolol concentrations obtained from 2.3-mm-diameter tissue punches of adjacent, non-coated sections using standard bulk tissue extraction protocols followed by regular HPLC-MS/MS analysis. Average concentration of propranolol in both organs determined by the two employed methods agreed within ±12%. Furthermore, the relative abundance of phase II hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous results.Conclusions: This work illustrates that depositing a thin parylene C layer onto thin tissue prior to analysis, which seals the surface and prevents direct liquid extraction of the drug from the tissue, coupled to the novel LA-dropletProbe surface sampling system is a viable approach for sub-mm resolution quantitative drug distribution analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated experimental studies of pore structure and fluid uptake in the Bossier Shale in eastern Texas, USA

Within the Haynesville-Bossier Shale complex, the Bossier Shale has not been extensively studied by either industry and academia, despite it being an unconventional gas reservoir and a potential caprock for carbon storage in the underlaying Haynesville Shale. The lack of knowledge of the complex pore structures and fluid-rock interactions hinders the effective extraction of gas and the characterization of fluid reservoirs and sealing capacity. Integrated experimental studies of pore structure and fluid-rock interactions were conducted in seven Bossier Shale core samples collected in eastern Texas. Petrographic, geochemical, and petrophysical properties such as mineral composition, organic richness, thermal maturity, porosity, pore/pore throat diameter distribution, water-accessible pores, liquid water imbibition, and water vapor adsorption were characterized using complementary approaches of thin-section petrography, scanning electron microscopy, X-ray diffraction, total organic matter, pyrolysis, mercury intrusion porosimetry, nuclear magnetic resonance, (Ultra-) small angle X-rays scattering as well as small angle neutron scattering with deuterated liquids and contrast variation. Further, the results show that the thermally mature Bossier Shales are composed of mixed argillaceous mudstone, mixed mudstone, and mixed carbonate mudstone. The shale contains both organic and inorganic pores, with porosities of 3.24-9.37 %, pore-to-throat ratios of 1.65 to 19.4, and water-accessible pores accounting for 28.7-72.6 % of total pores. Approaches of liquid water imbibition and water vapor adsorption, with and without direct contact of water with shale samples, indicate that liquid water first enters the nano-sized pores under high capillary pressures, and water vapor adsorption is mainly controlled by both clay minerals and pores with diameters less than 10 nm. These findings contribute to a better understanding of pore structures and water-shale interactions and their controlling factors in the Bossier Shale.

58 GEOSCIENCES↗

Triaxial Shear Tests on Simulated Sierra White Fault Gouge & Borehole Simulation in Sierra White Gouge

Laboratory shear tests were conducted on pulverized Sierra White granite (SWG) to investigate slip mechanisms in naturally occurring faults. Synthetic fault geometries were constructed by sandwiching fine grained SWG powder in between steel forcing blocks. For dry experiments, ~3.5 g of SWG powder was poured onto the face of the lower steel forcing block and leveled. For saturated experiments, enough fluid was added to the ~3.5 g of Sierra White granite powder to form a slurry. This slurry was applied to the lower forcing block and leveled. Inclined forcing blocks with 25.4 mm diameter and 35° faces, which were machined from ground steel rods with fine teeth on the faces, help to hold the gouge in place and prevent delamination at the interface. The top forcing block had a 2.03 mm centered hole to allow pore fluid access to the gouge. A fine steel mesh prevented back flow of the gouge into pore fluid lines. Samples were isolated from the confining medium using three layers of heat shrink polyolefin, as shown in Figure 1. The outer layer was shrunk over the o-rings on the end caps to form an impermeable seal, which was reinforced with steel tie wires on both sides of the o-rings. Hardened steel spacers and copper shim stock was placed between the steel forcing blocks and the end caps to preserve the parallelism of the Hastelloy wetted parts. For dry samples, the end caps were plugged, while the end caps for the saturated samples were connected to pore lines.

58 GEOSCIENCES↗