Geant4-based Analysis of Faraday Cup Performance for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab marks a significant advancement in high-energy physics research. This initiative aims to enhance Fermilab's accelerator complex by replacing the existing linear accelerator (linac) with a warm front end (WFE) capable of accelerating H- beams up to 2.1 MeV. Subsequently, a superconducting linac (SCL), that further accelerates these beams up to 800 MeV. To accurately measure the transverse beam profile, traditional wire scanners will be utilized in the WFE section, while Laser wire scanners will be implemented along the SCL. The Faraday cup for the Laser wire scanners has been designed using the GEANT4 simulation toolkit. This poster presents a detailed analysis of its performance along the SCL, focusing on electron absorption, secondary electron emission, backscattering, etc.

Wijethunga, S. A.K.↗

Emittance Measurements with Wire Scanners in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instru-ments to directly collect information on the beam s transverse distribution. The manipulation of the condi-tions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

43 PARTICLE ACCELERATORS↗

Oceanographic scanner system design study, volume 1

The design is reported of a dual mode multispectral scanner, capable of satisfying both overland and oceanographic requirements. A complete system description and performance summary of the scanner are given. In addition, subsystem and component descriptions and performance analyses are treated in individual sections. The design of the scanner, with minimum modifications, interfaces to the ERTS spacecraft and the ground data handling system.

Source record↗

Determining density of maize canopy. 2: Airborne multispectral scanner data

Multispectral scanner data were collected in two flights over a light colored soil background cover plot at an altitude of 305 m. Energy in eleven reflective wavelength band from 0.45 to 2.6 microns was recorded. Four growth stages of maize (Zea mays L.) gave a wide range of canopy densities for each flight date. Leaf area index measurements were taken from the twelve subplots and were used as a measure of canopy density. Ratio techniques were used to relate uncalibrated scanner response to leaf area index. The ratios of scanner data values for the 0.72 to 0.92 micron wavelength band over the 0.61 to 0.70 micron wavelength band were calculated for each plot. The ratios related very well to leaf area index for a given flight date. The results indicated that spectral data from maize canopies could be of value in determining canopy density.

Stoner, E. R.↗

Land use classification utilizing remote multispectral scanner data and computer analysis techniques

An airborne multispectral scanner was used to collect the visible and reflective infrared data. A small subdivision near Lafayette, Indiana was selected as the test site for the urban land use study. Multispectral scanner data were collected over the subdivision on May 1, 1970 from an altitude of 915 meters. The data were collected in twelve wavelength bands from 0.40 to 1.00 micrometers by the scanner. The results indicated that computer analysis of multispectral data can be very accurate in classifying and estimating the natural and man-made materials that characterize land uses in an urban scene.

Leblanc, P. N.↗

Systematic monitoring and evaluation of M7 scanner performance and data quality

An investigation was conducted to provide the information required to maintain data quality of the Michigan M7 Multispectral scanner by systematic checks on specific system performance characteristics. Data processing techniques which use calibration data gathered routinely every mission have been developed to assess current data quality. Significant changes from past data quality are thus identified and attempts made to discover their causes. Procedures for systematic monitoring of scanner data quality are discussed. In the solar reflective region, calculations of Noise Equivalent Change in Radiance on a permission basis are compared to theoretical tape-recorder limits to provide an estimate of overall scanner performance. M7 signal/noise characteristics are examined.

Stewart, S.↗

A general solution for the registration of optical multispectral scanners

The paper documents a general theory for registration (mapping) of data sets gathered by optical scanners such as the ERTS satellite MSS and the Skylab S-192 MSS. This solution is generally applicable to scanners which have rotating optics. Navigation data and ground control points are used in a statistically weighted adjustment based on a mathematical model of the dynamics of the spacecraft and the scanner system. This adjustment is very similar to the well known photogrammetric adjustments used in aerial mapping. Actual tests have been completed on NASA aircraft 24 channel MSS data, and the results are very encouraging.

Rader, M. L.↗

A coherent light scanner for optical processing of large format transparencies

A laser scanner is discussed in which the scanning beam is random-access addressable and perpendicular to the image input plane and the irradiance of the scanned beam is controlled so that a constant average irradiance is maintained after passage through the image plane. The scanner's optical system and design are described, and its performance is evaluated. It is noted that with this scanner, data in the form of large-format transparencies can be processed without the expense, space, maintenance, and precautions attendant to the operation of a high-power laser with large-aperture collimating optics. It is shown that the scanned format as well as the diameter of the scanning beam may be increased by simple design modifications and that higher scan rates can be achieved at the expense of resolution by employing acousto-optic deflectors with different relay optics.

Callen, W. R.↗

Data-handling considerations for advanced high-resolution multispectral scanners

Several scanner design parameters that greatly affect data rates were varied to determine overall effect on data rates. Bit rates were calculated for scanners with 10-, 15-, 20-, and 30-meter instantaneous fields of view; with 5, 7, and 10 channels; and with swath widths of 46.3, 92.6, 138.9, and 185.2 kilometers (25, 50, 75, and 100 nautical miles). The data were analyzed to determine whether they could be (1) recorded onboard the spacecraft with currently available equipment, (2) recorded onboard with the equipment proposed for the 1980-90 period, (3) transmitted to earth with current or proposed equipment; and (4) compressed and decompressed without significant degradation of classification accuracy. The effect of classifying 10-meter scanner data on the existing and the development pattern-recognition systems was examined.

Whitley, S. L.↗

Evaluation of an infrared horizon scanner bias determination algorithm for earth-oriented spacecraft

An algorithm for estimating infrared horizon scanner biases for earth-oriented spacecraft is presented. A mathematical description of the proposed algorithm is given, and the algorithm is evaluated for use by two earth-oriented spacecraft: the Applications Explorer Missions-A/Heat Capacity Mapping Mission (AEM-A/HCMM) and Seasat-A. The results of this study indicate that scanner alignment and calibration errors appear as nearly constant biases in the scanner pitch and roll data and that these constant biases can be estimated to within 0.05 degree for AEM-A and 0.03 degree for Seasat-A.

Hotovy, S. G.↗

Trophic classification of Colorado lakes utilizing contact data, Landsat and aircraft-acquired multispectral scanner data

Multispectral scanner data, acquired over several Colorado lakes using Landsat-1 and aircraft, were used in conjunction with National Eutrophication Survey contact-sensed data to determine the feasibility of assessing lacustrine trophic levels. A trophic state index was developed using contact-sensed data for several trophic indicators (chlorophyll a, inverse of Secchi disk transparency, conductivity, total phosphorous, total organic nitrogen, algal assay yield). Relationships between the digitally processed multispectral scanner data, several trophic indicators, and the trophic index were examined using a supervised multispectral classification technique and regression techniques. Statistically significant correlations exist between spectral bands, several of the trophic indicators (chlorophyll a, Secchi disk transparency, total organic nitrogen), and the trophic state index. Color-coded photomaps were generated which depict the spectral aspects of trophic state. Multispectral scanner data acquired from satellite and aircraft platforms can be used to advantage in lake monitoring and survey programs.

Boland, D. H. P.↗

The time-space relationship of the data point (Pixels) of the thematic mapper and multispectral scanner or the myth of simultaneity

A simplified explanation of the time space relationships among scanner pixels is presented. The examples of the multispectral scanner (MSS) on Landsats 1, 2, and 3 and the thematic mapper (TM) of Landsat D are used to describe the concept and degree of nonsimultaneity of scanning system data. The time aspects of scanner data acquisition and those parts of the MSS and TM systems related to that phenomena are addressed.

Gordon, F., Jr.↗

Design study for Thermal Infrared Multispectral Scanner (TIMS)

The feasibility of dividing the 8-12 micrometer thermal infrared wavelength region into six spectral bands by an airborne line scanner system was investigated. By combining an existing scanner design with a 6 band spectrometer, a system for the remote sensing of Earth resources was developed. The elements in the spectrometer include an off axis reflective collimator, a reflective diffraction grating, a triplet germanium imaging lens, a photoconductive mercury cadmium telluride sensor array, and the mechanical assembly to hold these parts and maintain their optical alignment across a broad temperature range. The existing scanner design was modified to accept the new spectrometer and two field filling thermal reference sources.

Stanich, C. G.↗

A radiation-hardened star scanner for spacecraft guidance and control

A star scanner for the Galileo Project is described. Because it must function in the intense Jupiter radiation field, which consists primarily of high-energy electrons and protons, this star scanner is designed with radiation-hardness as a prime objective. The optics and the multiplier phototube are specially designed to minimize fluorescence and Cerenkov effects, and the electronic components to minimize ionization and displacement damage. The star-scanner layout provides maximum shielding for the optics and phototube. Test results predict successful operation in the expected Jovian radiation environment.

Birnbaum, M. M.↗

Radiometric performance of the test-bed aircraft multispectral scanner /TBAMS/ system

Laboratory and flight radiometric performance testing of an experimental multispectral scanner system is described. High sensitivity performance is confirmed by test results using noise equivalent spectral radiance as the primary figure of merit. A performance comparison between the test-bed aircraft multispectral scanner (TBAMS) and the Bendix modular multispectral scanner (M2S) is presented. Methods for achieving high sensitivity operation are discussed as well as some of the practical implications of such operation for flight remote sensing experiments.

Jobson, D. J.↗

Preliminary analysis of ocean color scanner data from Superflux III

The ocean color scanner collected data Superflux III Experiment Single channel gray scale data products generated 5 minutes after the scanner data were collected showed details of the Chesapeake Plume structure, suggesting that this quick-look capability could have potential use to experimenters in real time. The Chesapeake Bay Plume extended offshore between 5 and 7 nautical miles on two occasions. The scanner data also show many other water features within the lower bay itself.

Ohlhorst, C. W.↗

Eddy current X-Y scanner system

The Nondestructive Evaluation Branch of the Materials and Processes Laboratory became aware of a need for a miniature, portable X-Y scanner capable of performing eddy current or other nondestructive testing scanning operations such as ultrasonic, or small areas of flat plate. The technical description and operational theory of the X-Y scanner system designed and built to fulfill this need are covered. The scanner was given limited testing and performs according to its design intent, which is to scan flat plate areas of approximately 412 sq cm (64 sq in) during each complete cycle of scanning.

Kurtz, G. W.↗

Development of Great Lakes algorithms for the Nimbus-G coastal zone color scanner

A series of experiments in the Great Lakes designed to evaluate the application of the Nimbus G satellite Coastal Zone Color Scanner (CZCS) were conducted. Absorption and scattering measurement data were reduced to obtain a preliminary optical model for the Great Lakes. Available optical models were used in turn to calculate subsurface reflectances for expected concentrations of chlorophyll-a pigment and suspended minerals. Multiple nonlinear regression techniques were used to derive CZCS water quality prediction equations from Great Lakes simulation data. An existing atmospheric model was combined with a water model to provide the necessary simulation data for evaluation of the preliminary CZCS algorithms. A CZCS scanner model was developed which accounts for image distorting scanner and satellite motions. This model was used in turn to generate mapping polynomials that define the transformation from the original image to one configured in a polyconic projection. Four computer programs (FORTRAN IV) for image transformation are presented.

Tanis, F. J.↗