Search NASA⌕ Search

SEARCH · Search NASA

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

ARM FY2025 Radar Plan

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility is dedicated to delivering high-quality radar data that significantly advance our understanding of cloud and precipitation processes, improving climate models. With radars operating across diverse frequencies, scanning modes, and global climate conditions, extensive staffing is essential for effective management. Due to current staffing constraints, achieving the expected level of operational excellence requires a more strategic approach. To address this challenge, ARM has developed an operational radar plan for the upcoming Fiscal Year 2025 (FY25) based on budget and staffing considerations. This report summarizes the Fiscal Year 2024 (FY24) ARM radar-related activities and outlines the strategic plan for FY25. It presents a comprehensive radar plan that includes detailed activities, priorities, and a projected timeline aligned with the ARM radar roadmap. Key tasks, detailed in Table 1, cover various radar operational stages and coordinated efforts among ARM teams.

54 ENVIRONMENTAL SCIENCES↗

Automatic cartography techniques for earth resources research

Progress in developing instrumentation and software for the EROS user facilities is reported. Significant progress has been made in developing the USGS binary-mode scanning digitizer which is described in detail. Other instrumentation and processes discussed include profile-generating techniques, a manual digitizer, image correlation systems, and some new photomechanical data processing techniques.

Edson, D. T.↗

Ultrasonics

Ultrasonic testing is discussed as a primary means of nondestructive evaluation of subsurface flaws. The advantages and disadvantages are listed. The elementary principles, basic components of test units, scan modes, resonance testing, detection of fatigue cracks, monitoring fatigue crack growth, and determination of residual stress are discussed.

Leonard, B. E.↗

The imaging experiment on Pioneer 10

In the period plus or minus 4 days from Jovian pericenter, Pioneer 10 returned data from 153 imaging sequences. Data were obtained with the imaging photopolarimeter, a 2.54-cm-diam and 8.6-cm-focal-length steerable telescope configured as a narrow beam (0.5-mrad) photometer in a spin scan mode of operation. Images were obtained in two spectral bands (390 to 500 nm and 595 to 720 nm), and seven of the most interesting pictures are shown and discussed.

Swindell, W.↗

Silicon solid/state linear arrays for multispectral high resolution imaging systems

Solid-state, electronically scanned, linear detector arrays are now available which can be used in a pushbroom scan mode imaging system for high-resolution multispectral earth resource survey applications. These arrays provide high performance in the visible to near-IR region. Two performance criteria must be assessed in the choice of a detector array: signal-to-noise ratio and spectral response. Consideration of diffraction limitations shows that optics size cannot be significantly reduced by using very low-noise detectors. The required spectral response for a viable detector array should not have spectral ripples that cause a low-level, but significant, error in the detected effective reflectance of the target.

Thompson, L. L.↗

Soil moisture detection by Skylab's microwave sensors

Terrain microwave backscatter and emission response to soil moisture variations are investigated using Skylab's 13.9 GHz RADSCAT (Radiometer-Scatterometer) system. Data acquired on June 5, 1973 over a test site in west-central Texas indicates a fair degree of correlation with composite rainfall. The scan mode was cross-track contiguous (CTC) with a pitch of 29.4 deg and no roll offset. Vertical polarization was employed with both radiometer and scatterometer. The composite rainfall was computed according to the flood prediction technique using rainfall data supplied by weather reporting stations.

Ulaby, F. T.↗

Bone mineral measurement - Skylab experiment M-078

Experimental observations of loss of bone mineral due to prolonged bedrest or weightlessness are reported. A new, precise method was employed that featured an essentially monoergetic photon source (125I) and a scintillation detector operating in a rectilinear scanning mode to measure bone mineral in the radius, ulna, and os calcis by the absorptiometric technique. Variable but small losses were found during 4-6 weeks of bedrest; losses of up to 40% were noted in the os calcis after 9 months. When the technique was used during the Apollo 14, 15, and 16 missions, only one crewmen showed significant losses in the os calcis and none in the radius or ulna. The variability recorded during bedrest was connected with the initial 24-hr urinary hydroxyproline excretion and the initial os calcis mineral content. The relevance of prediction terms based on bedrest data to Skylab and longer missions is discussed.

Vogel, J. M.↗

Biomedical ultrasonoscope

Portable, battery-powered device permits noninvasive examination of body's interior and is particularly well suited to real-time examination of heart. Instrument is capable of C-mode, A-mode, and M-mode scan display.

Lee, R. D.↗

Shuttle/spacelab MMAP/electromagnetic environment experiment phase B definition study

Progress made during the first five months of the Phase B definition study for the MMAP/Electromagnetic Environment Experiment (EEE) was described. An antenna/receiver assembly has been defined and sized for stowing in a three pallet bay area in the shuttle. Six scanning modes for the assembly are analyzed and footprints for various antenna sizes are plotted. Mission profiles have been outlined for a 400 km height, 57 deg inclination angle, circular orbit. Viewing time over 7 geographical areas are listed. Shuttle interfaces have been studied to determine what configuration the antenna assembly must have to be shared with other experiments of the Microwave Multi-Applications Payload (MMAP) and to be stowed in the shuttle bay. Other results reported include a frequency plan, a proposed antenna subsystem design, a proposed receiver design, preliminary outlines of the experiment controls and an analysis of on-board and ground data processing schemes.

Horton, J. B.↗

The imaging photopolarimeter - The first extraterrestrial spin-scan imager

The paper describes the imaging photopolarimeter used to take close-ups of Jupiter from Pioneers 10 and 11. The instrument operates in a steerable spin-scan mode of operation, contains a 1 in. diameter, f/3.4 Maksutov telescope with a focal plane aperture whose size is selectable. The paper examines those aspects of the design that are substantially influenced by the unusual design constraints, such as choice of detector and method of steering the telescope, and demonstrates the image processing and display techniques used to create the images from the telemetry and correct them for distortion and other defects.

Swindell, W.↗

Lander imaging as a detector of life on Mars

Biological goals were among the important science objectives of the Viking lander camera. The camera performance characteristics relevant to these goals are discussed. They include the ability to observe (1) morphological detail, (2) color and reflectance spectra, and (3) motion and change. The scenes obtained by the cameras were scrutinized in many ways: monoscopically, stereoscopically, in color, and by computerized differencing of camera events. At the lander sites and during the times that observations were carried out on the surface of Mars, no evidence, direct or indirect, has been obtained for macroscopic biology on Mars. No obvious examples of geometric distortion that might have been motion induced have been observed. Using the repeated line scanning mode of the camera has revealed no changes or motion suggesting life. These negative results may be due to limitations in sampling, in camera design, or in our understanding of Martian biology, but they are certainly consistent with the hypothesis that macroscopic life is absent on Mars.

Levinthal, E. C.↗

Diffuse-direct ultraviolet ratios with a compact double monochromator

An improved system has been implemented for measuring the ratio of the diffuse skylight to the direct sunlight in the biologically active region of the UV near the atmospheric limit. It combines a double monochromator employing holographic gratings for reduction of stray light with a cooled photomultiplier tube to provide a greatly improved SNR below 300 nm. Data may be obtained in either a scan mode or a narrowband photometry mode; in the latter mode accurate ratios have been obtained near 290 nm. Representative data are discussed along with a theoretical model of the ratio. The system is compact enough for use in a mobile monitoring system.

Garrison, L. M.↗

The WX-32193, a new 70 mm SEC image tube for astronomical application

The new SEC image camera tube is designed for astronomical application. Its large target allows a wide viewing angle with excellent resolution and little distortion, as the tube is magnetically focussed. The target is able to store information over several days and with proper cooling integration of weak light signals is possible over several hours. A sequential writing - reading slow scan mode is suggested for most effective application. The window is transmissive far into the vacuum UV-spectrum. Zooming with a fourfold magnification has been successfully demonstrated employing a magnetic lens in front of the image section. The tube construction is ruggedized to withstand the shock and vibration requirements of rocket launch.

Pietrzyk, J. P.↗

The MSFC Doppler lidar system, appendix B

The development of pulsed and continuous wave Doppler lidars for atmospheric measurement is discussed. A description of how the lidar systems operate is presented. The scanning mode is also described.

Bilbro, J. W.↗

Variable X-ray spectra of BL Lac objects: HEAO-1 observations of PKS 0548-322 and 2A 1219+305

X-ray spectra for the BL Lac objects PKS 0548-322 and 2A 1219+305 measured with the HEAO-1 A2 detectors during pointing maneuvers on September 30, 1978 and May 31, 1978 respectively are presented. Both fit single power law components with low energy absorption. For 2A 1219+305, a thermal bremsstrahlung form gives an unacceptable fit. From a comparison with other statistically poorer observations taken at 6 month intervals while the satellite was in its normal scanning mode, it is found that the sources exhibit spectral variability. A summary of measurements of the 5 BL Lac objects detected with the A2 experiment is presented and it is concluded that X-ray spectral changes in this class of source are common. Their general X-ray spectral characteristics distinguish BL Lac objects from other classes of X-ray emitting active galactic nuclei. Analysis of their total spectra indicates that most of the energy is emitted in the 5 to 100 eV band.

Worrall, D. M.↗

The soft X-ray polychromator for the Solar Maximum Mission

The paper considers the soft X-ray polychromator (XRP) operating in the 1.4-22.4 A range of the soft X-ray spectrum which includes many emission lines important for the diagnosis of plasmas in the 1.5-50 million deg temperature range. The flat crystal scanning spectrometer provides for a channel polychromatic mapping of flares and active regions in the resonance lines of O VIII, Ne IX, and Mg XI; in its spectral scanning mode it covers essentially the entire 1.4-22.5 A region.

Acton, L. W.↗

Determination of carrier concentration and compensation microprofiles in GaAs

Simultaneous microprofiling of semiconductor free carrier, donor, and acceptor concentrations was achieved for the first time from the absolute value of the free carrier absorption coefficient and its wavelength dependence determined by IR absorption in a scanning mode. Employing Ge- and Si-doped melt-grown GaAs, striking differences were found between the variations of electron concentration and those of ionized impurity concentrations. These results showed clearly that the electronic characteristics of this material are controlled by amphoteric doping and deviations from stoichiometry rather than by impurity segregation.

Jastrzebski, L.↗

PKS 2155-304 relativistically beamed synchrotron radiation from BL LAC object

The newly discovered BL Lacertae object, PKS 2155-304, was observed with the medium and high intensity energy detectors of the HEAO-1 A2 experiment. The variability by a factor of two in less than a day reported by Snyder, et al (1979) is confirmed. Two spectra, obtained a year apart, while the satellite was in scanning mode, are well fit by simple power laws with energy spectral index alpha sub 1 equals approximately 1.4. A third spectrum, of higher statistical quality, obtained while the satellite was pointed at its source, has has two components. An acceptable fit was obtained using a two power law model, with indices alpha sub 1 equals 2.0 (+1.2, -0.6) and alpha sub 2 equals -1.5 (+1.5, -2.3). An interpretation of the overall spectrum from radio through X-rays in terms of a synchrotron self-Compton model gives a good description of the data if allowance is made for relativistic beaming. Thus, from a consideration of the spectrum, combined with an estimate of the size of the source, the presence of jets is inferred without their observation.

Urry, C. M.↗