Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluating space transportation sensitivities with Taguchi methods

The lunar and Mars transportation system sensitivities and their effect on cost is discussed with reference to several design concepts using Taguchi analysis. The general features of the approach are outlined, and the selected Taguchi matrix (L18) is described. The modeling results are displayed in a Design of Experiments format to aid the evaluation of sensitivities.

Brown, Norman S.↗

A Method for Monitoring Organic Chlorides, Hydrochloric Acid and Chlorine in Air

While not commonly presented in nonurban atmospheres, organic chlorides, hydrochloric acid and chlorine are significant in industrial air pollution and industrial hygiene. Based on a microcoulometer, a much more sensitive method than has heretofore been available has been developed for monitoring these air impurities. The method has a response time (90%) of about twenty seconds, requires no calibration, is accurate to +/- 2.5%, and specific except for bromide and iodide interferences. The instrument is portable and has been operated unattended for 18 hours without difficulty.

Dennison, J. E.↗

Sensitivity analysis as an aid in modelling and control of (poorly-defined) ecological systems

A literature review of the use of sensitivity analyses in modelling nonlinear, ill-defined systems, such as ecological interactions is presented. Discussions of previous work, and a proposed scheme for generalized sensitivity analysis applicable to ill-defined systems are included. This scheme considers classes of mathematical models, problem-defining behavior, analysis procedures (especially the use of Monte-Carlo methods), sensitivity ranking of parameters, and extension to control system design.

Hornberger, G. M.↗

Fuels characterization studies

Current analytical techniques used in the characterization of broadened properties fuels are briefly described. Included are liquid chromatography, gas chromatography, and nuclear magnetic resonance spectroscopy. High performance liquid chromatographic ground-type methods development is being approached from several directions, including aromatic fraction standards development and the elimination of standards through removal or partial removal of the alkene and aromatic fractions or through the use of whole fuel refractive index values. More sensitive methods for alkene determinations using an ultraviolet-visible detector are also being pursued. Some of the more successful gas chromatographic physical property determinations for petroleum derived fuels are the distillation curve (simulated distillation), heat of combustion, hydrogen content, API gravity, viscosity, flash point, and (to a lesser extent) freezing point.

Seng, G. T.↗

Saltation threshold detection in a wind tunnel by the measurement of the net electrostatic charge

The Mars surface wind tunnel (MARSWIT) is an open circuit wind tunnel used for aeolian studies and is located inside a large vacuum chamber allowing testing at Martian surface atmospheric pressure. Since direct access is not available to the tunnel during operation at low pressure, a remote method of saltation detection is needed. The bed is observed by means of closed circuit video, but it is often difficult to determine the initiation of threshold. The measurement by means of an electrometer of the net electric charge produced by the saltating particles has provided a reliable means of saltation threshold detection. Saltating particles become charged several ways, both in wind tunnels and in a natural environment. The most significant of these methods are tribo-charging and contact charging, which always occur. Fracture charging may also occur under the high velocities associated with particle transport on Mars or under simulated Martian conditions. Detection in MARSWIT is achieved by allowing the saltating particles to impinge on a planar conducting surface normal to the flow that is connected to ground through a Keithly electrometer. The signal from the electrometer is connected to a strip chart recorder along with the analog signal from the pitot tube transducer that is used to determine the wind velocity in the tunnel. Thus, a record of wind velocity and the initiation of particle saltation is conveniently displayed together. While both positive and negative charges are produced during saltation, this method measures only the net charge; thus the charge may be either positive or negative depending upon the particles being tested, the size and size distribution of the test material, and the wind velocity. This has proven to be a very trustworthy and sensitive method of saltation threshold detection, being especially useful with the smaller sized particles which are the most difficult to observe visually.

Leach, Rodman N.↗

PAHs and the Diffuse Interstellar Bands. What have we Learned from the New Generation of Laboratory and Observational Studies?

Polycyclic Aromatic Hydrocarbons (PAHs) are an important and ubiquitous component of carbon-bearing materials in space. PAHs are the best-known candidates to account for the IR emission bands (UIR bands) and PAH spectral features are now being used as new probes of the ISM. PAHs are also thought to be among the carriers of the diffuse interstellar absorption bands (DIBs). In the model dealing with the interstellar spectral features, PAHs are present as a mixture of radicals, ions and neutral species. PAH ionization states reflect the ionization balance of the medium while PAH size, composition, and structure reflect the energetic and chemical history of the medium. A major challenge for laboratory astrophysics is to reproduce (in a realistic way) the physical conditions that exist in the emission and/or absorption interstellar zones, An extensive laboratory program has been developed at NASA Ames to characterize the physical and chemical properties of PAHs in astrophysical environments and to describe how they influence the radiation and energy balance in space and the interstellar chemistry. In particular, laboratory experiments provide measurements of the spectral characteristics of interstellar PAH analogs from the ultraviolet and visible range to the infrared range for comparison with astronomical data. This paper will focus on the recent progress made in the laboratory to measure the direct absorption spectra of neutral and ionized PAHs in the gas phase in the near-W and visible range in astrophysically relevant environments. These measurements provide data on PAHs and nanometer-sized particles that can now be directly compared to astronomical observations. The harsh physical conditions of the IS medium - characterized by a low temperature, an absence of collisions and strong V W radiation fields - are simulated in the laboratory by associating a molecular beam with an ionizing discharge to generate a cold plasma expansion. PAH ions are formed from the neutral precursors in an isolated environment at low temperature (of the order of 100 K). The spectra of neutral and ionized PAHs are measured using the high sensitivity methods of cavity ring down spectroscopy (CRDS). These experiments provide unique information on the spectra of free, cold large carbon molecules and ions in the gas phase. Intrinsic band profiles and band positions of cold gas-phase PAHs can now be measured with high- sensitivity spectroscopy and directly compared to the astronomical data. The electronic bands measured for ionized PAH are found to be intrinsically broad (about 20/cm) while the bands associated with the neutral precursors are narrower (of the order of 2 - 10/cm).

Salama, Farid↗

Interstellar PAH in the Laboratory and in Space. What have we Learned from the New Generation of Laboratory and Observational Studies?

Polycyclic Aromatic Hydrocarbons (PAHs) are an important and ubiquitous component of carbon-bearing materials in space. PAHs are the best-known candidates to account for the IR emission bands (UIR bands) and PAH spectral features are now being used as new probes of the ISM. PAHs are also thought to be among the carriers of the diffuse interstellar absorption bands (DIBs). In the model dealing with the interstellar spectral features, PAHs are present as a mixture of radicals, ions and neutral species. PAH ionization states reflect the ionization balance of the medium while PAH size, composition, and structure reflect the energetic and chemical history of the medium. A major challenge for laboratory astrophysics is to reproduce (in a realistic way) the physical conditions that exist in the emission and/or absorption interstellar zones. An extensive laboratory program has been developed at NASA Ames to assess the physical and chemical properties of PAHs in such environments and to describe how they influence the radiation and energy balance in space and the interstellar chemistry. In particular, laboratory experiments provide measurements of the spectral characteristics of interstellar PAH analogs from the ultraviolet and visible range to the infrared range for comparison with astronomical data. This paper will focus on the recent progress made in the laboratory to measure the direct absorption spectra of neutral and ionized PAHs in the gas phase in the near-UV and visible range in astrophysically relevant environments. These measurements provide data on PAHs and nanometer-sized particles that can now be directly compared to astronomical observations. The harsh physical conditions of the IS medium - characterized by a low temperature, an absence of collisions and strong VUV radiation fields - are simulated in the laboratory by associating a molecular beam with an ionizing discharge to generate a cold plasma expansion. PAH ions are formed from the neutral precursors in an isolated environment at low temperature (of the order of 100 K). The spectra of neutral and ionized PAHs are measured using the high sensitivity methods of cavity ring down spectroscopy (CRDS). These experiments provide unique information on the spectra of free, cold large carbon molecules and ions in the gas phase. Intrinsic band profiles and band positions of cold gas-phase PAHs can now be measured with high-sensitivity spectroscopy and directly compared to the astronomical data. The electronic bands measured for ionized PAH are found to be intrinsically broad (about 20 cm(sup -1)) while the bands associated with the neutral precursors are narrower (of the order of 2 - 10 cm(sup -1)). The laboratory data are discussed and compared with recent astronomical spectra of large and narrow DIBs and with the spectra of circumstellar environments of selected carbon stars and the implications for the interstellar PAH population are derived. Preliminary results also show that carbon nanoparticles are formed during the short residence time of the precursors in the plasma.

Salama, Farid↗

Comparison of GEOS-5 AGCM Planetary Boundary Layer Depths Computed with Various Definitions

Accurate models of planetary boundary layer (PBL) processes are important for forecasting weather and climate. The present study compares seven methods of calculating PBL depth in the GEOS-5 atmospheric general circulation model (AGCM) over land. These methods depend on the eddy diffusion coefficients, bulk and local Richardson numbers, and the turbulent kinetic energy. The computed PBL depths are aggregated to the Koppen climate classes, and some limited comparisons are made using radiosonde profiles. Most methods produce similar midday PBL depths, although in the warm, moist climate classes, the bulk Richardson number method gives midday results that are lower than those given by the eddy diffusion coefficient methods. Additional analysis revealed that methods sensitive to turbulence driven by radiative cooling produce greater PBL depths, this effect being most significant during the evening transition. Nocturnal PBLs based on Richardson number are generally shallower than eddy diffusion coefficient based estimates. The bulk Richardson number estimate is recommended as the PBL height to inform the choice of the turbulent length scale, based on the similarity to other methods during the day, and the improved nighttime behavior.

AGCM↗

Laboratory Methods for the Measurement of Pollutants in Water and Waste Effluents

The requirement for accurate, precise, and rapid analytical procedures for the examination of water and waste samples requires the use of a variety of instruments. The instrumentation in water laboratories includes atomic absorption, UV-visible. and infrared spectrophotometers, automatic colorimetric analyzers, gas chromatographs and mass spectrometers. Because of the emphasis on regulatory action, attention is being directed toward quality control of analytical results. Among the challenging problems are the differentiation of metallic species in water at nanogram concentrations, rapid measurement of free cyanide and free ammonia, more sensitive methods for arsenic and selenium and improved characterization of organic contaminants.

Ballinger, Dwight G.↗

Comparative Study in Laboratory Rats to Validate Sperm Quality Methods and Endpoints

Abstract The Naval Health Research Center, Detachment (Toxicology) performs toxicity studies in laboratory animals to characterize the risk of exposure to chemicals of Navy interest. Research was conducted at the Toxicology Detachment at WPAFB, OH in collaboration with Wright State University, Department of Biological Sciences for the validation of new bioassay methods for evaluating reproductive toxicity. The Hamilton Thorne sperm analyzer was used to evaluate sperm damage produced by exposure to a known testicular toxic agent, methoxyacetic acid and by inhalation exposure to JP-8 and JP-5 in laboratory rats. Sperm quality parameters were evaluated (sperm concentration, motility, and morphology) to provide evidence of sperm damage. The Hamilton Thorne sperm analyzer utilizes a DNA specific fluorescent stain (similar to flow cytometry) and digitized optical computer analysis to detect sperm cell damage. The computer assisted sperm analysis (CASA) is a more rapid, robust, predictive and sensitive method for characterizing reproductive toxicity. The results presented in this poster report validation information showing exposure to methoxyacetic acid causes reproductive toxicity and inhalation exposure to JP-8 and JP-5 had no significant effects. The CASA method detects early changes that result in reproductive deficits and these data will be used in a continuing program to characterize the toxicity of chemicals, and combinations of chemicals, of military interest to formulate permissible exposure limits.

Price, W. A.↗

Vibro-Acoustic Modulation Based Damage Identification in a Composite Skin-Stiffener Structure

The vibro-acoustic modulation method is applied to a composite skin-stiffener structure to investigate the possibilities to utilize this method for damage identification in terms of detection, localisation and damage quantification. The research comprises a theoretical part and an experimental part. An impact load is applied to the skin-stiffener structure, resulting in a delamination underneath the stiffener. The structure is interrogated with a low frequency pump excitation and a high frequency carrier excitation. The analysis of the response in a frequency band around the carrier frequency is employed to assess the damage identification capabilities and to gain a better understanding of the modulations occurring and the underlying physical phenomena. Though vibro-acoustic is shown to be a sensitive method for damage identification, the complexity of the damage, combined with a high modal density, complicate the understanding of the relation between the physical phenomena and the modulations occurring. more research is recommended to reveal the physics behind the observations.

Ooijevaar, T. H.↗

Standardization of Spore Inactivation Method for PMA-PhyloChip Analysis

In compliance with the Committee on Space Research (COSPAR) planetary protection policy, National Aeronautics and Space Administration (NASA) monitors the total microbial burden of spacecraft as a means for minimizing the inadvertent transfer of viable contaminant microorganisms to extraterrestrial environments (forward contamination). NASA standard assay-based counts are used both as a proxy for relative surface cleanliness and to estimate overall microbial burden as well as to assess whether forward planetary protection risk criteria are met for a given mission, which vary by the planetary body to be explored and whether or not life detection missions are present. Despite efforts to reduce presence of microorganisms from spacecraft prior to launch, microbes have been isolated from spacecraft and associated surfaces within the extreme conditions of clean room facilities using state of the art molecular technologies. Development of a more sensitive method that will better enumerate all viable microorganisms from spacecraft and associated surfaces could support future life detection missions. Current culture-based (NASA standard spore assay) and nucleic-acid-based polymerase chain reaction (PCR) methods have significant shortcomings in this type of analysis. The overall goal of this project is to evaluate and validate a new molecular method based on the use of a deoxyribonucleic acid (DNA) intercalating agent propidium monoazide (PMA). This is used in combination with DNA microarray (PhyloChip) which has been shown to identify very low levels of organisms on spacecraft associated surfaces. PMA can only penetrate the membrane of dead cells. Once penetrated, it intercalates the DNA and, upon photolysis using visible light it produces stable DNA monoadducts. This allows DNA to be unavailable for further PCR analysis. The specific aim of this study is to standardize the spore inactivation method for PMA-PhyloChip analysis. We have used the bacterial spores Bacillus subtilis 168 (standard laboratory isolate) as a test organism.

spore inactivation↗

Identification and evaluation of linear damping models in beam vibrations

Sensitive method, identifying effective damping mechanisms, involves comparing experimentally determined ratio of first to second mode magnification factors related to common point on beam. Cluster size has little effect on frequencies of elements, magnification factor decreases with cluster size, and viscous and stress damping are dominant damping mechanisms.

Boers, B. L.↗

The use of the transmission windows of the Fabry-Perot interferometer in the detection of Raman scattered radiation from atmospheric gases.

Demonstration that the use of the Fabry-Perot interferometer as a filter with transmission windows occurring at regular intervals in wave numbers provides a highly sensitive method for detection of atmospheric gases using their rotational Raman spectra excited by a suitable laser. Some of the operating advantages include signal gains of several orders of magnitude, a simple direct interpretation of the results in terms of the density and types of the gaseous constituents, size and weight reductions from conventional apparatus, ease of operation, and relative freedom from interference from other molecules in the scattering volume. This method is compared with the techniques that have been discussed in the literature by other workers in the field.

Smith, W. H.↗

The simultaneous quantitation of ten amino acids in soil extracts by mass fragmentography

A specific and sensitive method for the identification and simultaneous quantitation by mass fragmentography of ten of the amino acids present in soil was developed. The technique uses a computer driven quadrupole mass spectrometer and a commercial preparation of deuterated amino acids is used as internal standards for purposes of quantitation. The results obtained are comparable with those from an amino acid analyzer. In the quadrupole mass spectrometer-computer system up to 25 pre-selected ions may be monitored sequentially. This allows a maximum of 12 different amino acids (one specific ion in each of the undeuterated and deuterated amino acid spectra) to be quantitated. The method is relatively rapid (analysis time of approximately one hour) and is capable of the quantitation of nanogram quantities of amino acids.

Pereira, W. E.↗

Determination of hydrogen in milligram quantities of titanium and its alloys

An accurate, versatile, and sensitive method for the determination of hydrogen in milligram-size titanium samples is presented. It involves extraction of hydrogen at 1070 K while a mercury diffusion pump transfers the evolved gases into the inlet of a mass spectrometer. All the evolved gases may then be positively identified and determined. This method can be readily adapted for use with other metals and for the study of the slow evolution of hydrogen. Reduction of interferences due to the evolution of hydrogen by reactions involving vapors such as those of water, acetone, and vacuum grease is discussed.

Otterson, D. A.↗

Gas-liquid chromatography in lunar organic analysis.

Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

Gehrke, C. W.↗