Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evolutionary Adaptive Discovery of Phased Array Sensor Signal Identification

Tomography, used to create images of the internal properties and features of an object, from phased array ultasonics is improved through many sophisiticated methonds of post processing of data. One approach used to improve tomographic results is to prescribe the collection of more data, from different points of few so that data fusion might have a richer data set to work from. This approach can lead to rapid increase in the data needed to be stored and processed. It also does not necessarily lead to have the needed data. This article describes a novel approach to utilizing the data aquired as a basis for adapting the sensors focusing parameters to locate more precisely the features in the material: specifically, two evolutionary methods of autofocusing on a returned signal are coupled with the derivations of the forumulas for spatially locating the feature are given. Test results of the two novel methods of evolutionary based focusing (EBF) illustrate the improved signal strength and correction of the position of feature using the optimized focal timing parameters, called Focused Delay Identification (FoDI).

97 MATHEMATICS AND COMPUTING↗

Integrating Hybrid-Clustering and Localized Regression for Time Synchronization of a Hierarchical Underwater Acoustic Sensor Array

Time synchronization is a critical requirement for the application of underwater acoustic sensor network (UWSN). Although a number of time synchronization protocols have been proposed for UWSN, none of them can be directly applied to autonomous acoustic receivers due to lack of hardware platform to communicate with each other. In this paper, we propose a machine learning-based time synchronization framework for autonomous receiver arrays, using the Juvenile Salmon Acoustic Telemetry System as a case study. The proposed framework consists of array partition and time synchronization. Using detections of receiver attached beacons as input, this framework synchronizes all receiver clocks to a root receiver clock. The framework has been successfully used in a field study at Trevallyn Dam forebay in Tasmania, Australia.

Fu, Tao↗

Quantitative decoding of the response a ceramic mixed potential sensor array for engine emissions control and diagnostics

The development of on-board sensors for emissions monitoring is necessary for continuous monitoring of the performance of catalytic systems in automobiles. We have fabricated mixed potential electrochemical gas sensing devices with Pt, La 0.8 Sr 0.2 CrO 3 (LSCO), and Au/Pd alloy electrodes and a porous yttria-stabilized zirconia electrolyte. The three-electrode design takes advantage of the preferential selectivity of the Pt + Au/Pd and Pt + LSCO pairs towards different species of gases and has additional tunable selectivity achieved by applying a current bias to the latter pair. Voltages were recorded in single, binary, and ternary gas streams of NO, NO 2 , C 3 H 8 , and CO. We have also trained artificial neural networks to examine the voltage output from sensors in biased and unbiased modes to both identify which single test gas or binary mixture of two test gases is present in a gas stream as well as extract concentration values. We were then able to identify single and binary mixtures of these gases with accuracy of at least 98%. For determining concentration, the peak in the error distribution for binary mixtures was 5% and 80% of test data fell under <12% error. The sensor stability was also evaluated over the course of over 100 days and the ability to retrain ANNs with a small dataset was demonstrated.

33 ADVANCED PROPULSION SYSTEMS↗

Coolant Pressure Evaluations for a MEMS Sensor-Array Quench Detection in REBCO CICC Superconducting Cables

Here, the initial quench pressure developments for a CICC cable of REBCO tapes have been investigated by numerical analyzing the first law of thermodynamics. The temperature and pressure rise due to the quench has been evaluated for a REBCO CICC conductor operated in helium gas coolant at 26 K. Additionally, a MEMS sensor-in-tube array method has been proposed and discussed for quench detection.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Next Generation Ta-STJ Sensor Arrays for BSM Physics Searches

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment uses superconducting tunnel junction (STJ) sensors to search for physics beyond the standard model (BSM) with recoil spectroscopy of the 7 Be EC decay into 7 Li. A pulsed UV laser is used to calibrate the STJs throughout the experiment with ∼20 meV precision. Phase-III of the BeEST experiment revealed a systematic calibration discrepancy between STJs. We found these artifacts to be caused by resistive crosstalk and by intensity variations of the calibration laser. For phase-IV of the BeEST experiment, we have removed the crosstalk by designing the STJ array so that each pixel has its own ground wire. We now also use a more stable UV laser for calibration. The new STJ arrays were fabricated at STAR Cryoelectronics and tested at LLNL and FRIB. They have the same high energy resolution of ∼1-2~eV in the energy range of interest below 100~eV as before, and they no longer exhibit the earlier calibration artifacts. We discuss the design changes and the STJ array performance for the next phase of the BeEST experiment.

Laser Calibration↗

Exploitation of Geometric Occlusion and Covariance Spectroscopy in a Gamma Sensor Array

The National Security Technologies, LLC, Remote Sensing Laboratory has recently used an array of six small-footprint (1-inch diameter by 3-inch long) cylindrical crystals of thallium-doped sodium iodide scintillators to obtain angular information from discrete gamma ray–emitting point sources. Obtaining angular information in a near-field measurement for a field-deployed gamma sensor is a requirement for radiological emergency work. Three of the sensors sit at the vertices of a 2-inch isosceles triangle, while the other three sit on the circumference of a 3-inch-radius circle centered in this triangle. This configuration exploits occlusion of sensors, correlation from Compton scattering within a detector array, and covariance spectroscopy, a spectral coincidence technique. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. By evaluating the values of, and the uncertainties in, the photopeak areas, efficiencies, branching ratio, peak area correction factors, and the correlations between these quantities, one can determine the precise activity of a particular radioisotope from a mixture of radioisotopes that have overlapping photopeaks that are ordinarily hard to deconvolve. The spectral coincidence technique, often known as covariance spectroscopy, examines the correlations and fluctuations in data that contain valuable information about radiation sources, transport media, and detection systems. Covariance spectroscopy enhances radionuclide identification techniques, provides directional information, and makes weaker gamma-ray emission—normally undetectable by common spectroscopic analysis—detectable. A series of experimental results using the concept of covariance spectroscopy are presented.

occlusion, covariance spectroscopy, correlations, ↗

Four-channel optically pumped magnetometer for a magnetoencephalography sensor array

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

Iivanainen, Joonas (ORCID:0000000160344604)↗

L-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array

Here, we present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements then demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100–2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation tool for optical design of PET detector modules including scintillator material and sensor array

The appearance of single photon avalanche diodes (SPADs) in the field of PET detector modules made it necessary to apply more complex optical design methods to refine the performance of such assemblies. We developed a combined simulation tool that is capable to model complex detector structures including scintillation material, light guide, light collection optics and sensor, correctly taking into account the statistical behavior of emission of scintillation light and its absorbance in SPADs. As a validation we compared simulation results obtained by our software and another optical design program. Calculations were performed for a simple PET detector arrangement used for testing purposes. According to the results, deviation of center of gravity coordinates between the two simulations is 0.0195 mm, the average ratio of total counts 1.0052. We investigated the error resulting from finite sampling in wavelength space and we found that 20 nm pitch is sufficient for the simulation in case of the given spectral dependencies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research and Development of Non-Spectroscopic MEMS-Based Sensor Arrays for Targeted Gas Detection

In this report, we present our progress during Fiscal Year 2012 (FY12) in the research and development of a non-spectroscopic method for noble gas detection. During Fiscal Year 2011 (FY11), we demonstrated that coating-free damped resonance detection (cfDRD) could be used for the selective sensing of pure gases and simple (binary) admixtures. Specifically, it was found that a sensor response signature comprised of both resonant peak shape change and frequency shift data exhibited increased chemical selectivity over a response signature based only on the latter contribution. The sensor response signature is presently comprised of three distinct data inputs: two channels from the cfDRD sensor component [shape change (attenuation/amplification), frequency shift], and one from a thermal conductivity detection (TCD) sensor component. A single commercial-off-the-shelf (COTS) resonator (Bruker Active Probe microcantilever) was excited into either its 1 st or 4 th resonant modes, where it was found that the latter was apparently insensitive to compositional changes in the surrounding gas; this difference was attributed to the ~20x difference in average flexural displacement in the former versus the latter, and the expected dominance of inertial effects in the damping phenomenon.

42 ENGINEERING↗

Resonant Soft X-Ray Scattering from Stripe-Ordered La 2 - x Ba x Cu O 4 Detected by a Transition-Edge Sensor Array Detector

Resonant soft x-ray scattering (RSXS) is a leading probe of valence-band order in materials best known for detecting charge-density-wave order in copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background, which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the study of weak signals such as diffuse scattering from glassy or fluctuating order that is spread widely over momentum space. Recent advances in superconducting transition-edge-sensor (TES) detectors have led to major improvements in energy resolution and detection efficiency in the soft x-ray range. Here, we perform a RSXS study of stripe-ordered La 2 - x Ba x Cu O 4 at the Cu L 3 / 2 edge (932.2 eV) using a TES detector with 1.5-eV resolution, to evaluate its utility for mitigating the fluorescence-background problem. We find that, for suitable degree of detuning from the resonance, the TES rejects the fluorescence background, leading to a five to ten times improvement in the statistical quality of the data compared to an equivalent, energy-integrated measurement. We conclude that a TES introduces a promising method to reducing background in RSXS studies and may lead to discoveries in materials exhibiting valence-band order that is fluctuating or glassy.

36 MATERIALS SCIENCE↗