Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor data validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A portable time-domain LED fluorimeter for nanosecond fluorescence lifetime measurements

Fluorescence lifetime measurements are becoming increasingly important in chemical and biological research. Time-domain lifetime measurements offer fluorescence multiplexing and improved handling of interferers compared with the frequency-domain technique. In this paper, an all solid-state, filterless, and highly portable light-emitting-diode based time-domain fluorimeter (LED TDF) is reported for the measurement of nanosecond fluorescence lifetimes. LED based excitation provides more wavelengths options compared to laser diode based excitation, but the excitation is less effective due to the uncollimated beam, less optical power, and longer latency in state transition. Pulse triggering and pre-bias techniques were implemented in our LED TDF to improve the peak optical power to over 100 mW. The proposed pulsing circuit achieved an excitation light fall time of less than 2 ns. Electrical resetting technique realized a time-gated photo-detector to remove the interference of the excitation light with fluorescence. These techniques allow the LED fluorimeter to accurately measure the fluorescence lifetime of fluorescein down to concentration of 0.5 μM. In addition, all filters required in traditional instruments are eliminated for the non-attenuated excitation/emission light power. These achievements make the reported device attractive to biochemical laboratories seeking for highly portable lifetime detection devices for developing sensors based on fluorescence lifetime changes. The device was initially validated by measuring the lifetimes of three commercial fluorophores and comparing them with reported lifetime data. It was subsequently used to characterize a ZnSe quantum dot based DNA sensor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feasibility Study of Millimeter Wave Radars For Safeguards Applications

Containment and surveillance are fundamental measures in nuclear safeguards. Techniques such as video surveillance and laser curtain for containment provide effective monitoring in areas where maintaining continuity of knowledge is required. These systems, however, can be susceptible to loss of monitoring capabilities under certain environmental conditions such as poor visibility (i.e. low light conditions, smoke, fog, etc.) or extended power loss past the duration that the backup power system is designed for. Brookhaven National Laboratory has been investigating the feasibility of millimeter waves (mmWave) as a new perimeter seal in which radio frequency waves in the range of 60-64 GHz are used to detect and monitor objects of interest. Signals in this frequency range are not susceptible to environmental conditions. For proof-of-concept tests, mmWave sensors from Texas Instruments (TI), specificallyIWR6843, are used in a test bed at BNL's Waste Management facility to simulate the operations at nuclear facilities. The unique design of TI mmWave sensors requires less memory and power consumption compared to counterpart systems. These devices are capable of exporting 3D point-cloud data, which is visualized graphically and compared to videos recorded at the same time to validate the performance of the mmWave sensor. A set of experiments were planned to test the feasibility of the mmWave in this application, including monitoring static containers in a storage area and detecting intrusions at the boundaries of the area. In addition, the experiments also identify potential blind spots relative to sensor position and utilize multiple operating sensors simultaneously to reduce or eliminate such blind spots. The optimal positioning of multiple sensors was determined for the experimental room configuration. In this paper, we will discuss the details of this novel perimeter sealing concept and present the test results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Upcoming Irradiation of Ultrasonic and Fiber Optic Sensors in the MITR

Fiber optic and ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. These technologies, which have performed successfully in out-of-pile tests, have not been well qualified in a test reactor environment. The uncertainty of successful operation of instruments at this level of development has typically been a significant barrier to in-core deployment. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of these technologies to provide enhanced sensors for irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. The National Scientific User Facility (NSUF) is sponsoring a project to evaluate the performance of promising temperature sensors based on ultrasound and on fiber optics during an upcoming irradiation test in the Massachusetts Institute of Technology Research Reactor (MITR). Several types of thin-wire metallic waveguide ultrasonic thermometers will be tested along with fiber optic temperature sensors using regenerated Fiber-Bragg Grating technology. Additionally, samples of several new optical materials which are potentially much more radiation tolerant than commonly used materials, such as silica, will be included and analyzed post-irradiation. The irradiation is a collaborative effort between researchers from Idaho National Laboratory, the French Alternative Energies and Atomic Energy Commission, the University of Pittsburgh, the Massachusetts Institute of Technology, and AFO Research, Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upcoming irradiation of ultrasonic and fiber optic sensors in the MITR - 361

Fiber optic and ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. These technologies, which have performed successfully in out-of-pile tests, have not been well qualified in a test reactor environment. The uncertainty of successful operation of instruments at this level of development has typically been a significant barrier to in-core deployment. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of these technologies to provide enhanced sensors for irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. The National Scientific User Facility (NSUF) is sponsoring a project to evaluate the performance of promising temperature sensors based on ultrasound and on fiber optics during an upcoming irradiation test in the Massachusetts Institute of Technology Research Reactor (MITR). Several types of thin-wire metallic waveguide ultrasonic thermometers will be tested along with fiber optic temperature sensors using regenerated Fiber-Bragg Grating technology. Additionally, samples of several new optical materials which are potentially much more radiation tolerant than commonly used fiber materials, such as silica, will be included and analyzed post-irradiation. The irradiation is a collaborative effort between researchers from Idaho National Laboratory, the French Alternative Energies and Atomic Energy Commission, the University of Pittsburgh, the Massachusetts Institute of Technology, and AFO Research, Inc. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IPC-Fusion (Infrastructure Perception and Control (IPC): Multisensor Data Fusion Software) [SWR-25-153]

As part of the National Laboratory of the Rockies' (NLR’s) Infrastructure Perception and Control Laboratory, the IPC-Fusion toolkit provides a probabilistic, scalable, multi-sensor fusion framework that integrates (late-stage fusion) heterogeneous object detection data from traffic sensors to enable robust, real-time tracking of roadway occupants. The algorithmic design of the toolkit is motivated by the need for creating a digital twin of traffic at the edge in a scalable and affordable manner. The software operates by combining object-level measurements (such as position and velocity) from a suite of sensors (such as radar, lidar, camera) using Kalman filtering and probabilistic data association techniques to overcome individual sensor limitations and achieve superior tracking performance in complex traffic zones. The framework addresses key challenges including heterogeneous measurement uncertainties, asynchronous data streams, varying spatiotemporal data resolutions, robust data association, and adaptive object lifecycle management. Validated on real-world traffic intersection data including vehicles and pedestrians, IPC-Fusion demonstrates enhanced tracking reliability across scenarios involving occlusions, sensor failures, and varying traffic densities, supporting the broader IPC initiative's goal of transforming transportation infrastructure through advanced perception capabilities for intelligent transportation systems, traffic safety applications, and autonomous vehicle support.

Sandhu, Rimple [National Laboratory of the Rockies↗

NWB Sensors Infrared Cloud Imager Data Products from SGP

NWB Sensors is a company which has developed a commercially available Infrared Cloud Imager (ICI). For more information, consult the company's webpage, https://www.nwbsensors.com/infrared-cloud-imager. To validate the radiometric accuracy of the ICI, NWB Sensors deployed it to the ARM SGP User Facility in 2023. The primary motivation of this deployment was to perform an intercomparison between the ICI and the Atmospheric Emitted Radiance Interferometer (AERI). The AERI spectral radiance data product can be integrated across the response function of the ICI and directly compared to the zenith radiance observed by the ICI. In addition, the ICI uses proprietary models of the downwelling clear-sky radiance in its cloud processing algorithms. They are based on surface meteorology and precipitable water vapor (PWV). These models were validated by comparing their predicted radiances to those derived from radiative transfer models of the ARM radiosondes. Finally, PWV observations derived from the ICI's onboard GNSS-based PWV retrieval system were compared against those from the microwave radiometer. This dataset contains the ICI radiance and cloud data products.

Atmosphere↗

Thermal Hydraulic Experimental Test Article: Status Report for FY2019

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, the secondary system in the 18-inch Test Vessel #6, and its sodium-to-air heat exchanger will occupy the location for 18-inch Test Vessel #5 (Test Vessel #5 will not be installed), Figure 2. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article - Status Report for FY2019 (Rev. 1)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-omics approach identifies molecular mechanisms of plant-fungus mycorrhizal interaction

In mycorrhizal symbiosis, plant roots form close, mutually beneficial interactions with soil fungi. Before this mycorrhizal interaction can be established however, plant roots must be capable of detecting potential beneficial fungal partners and initiating the gene expression patterns necessary to begin symbiosis. To predict a plant root – mycorrhizal fungi sensor systems, we analyzed in vitro experiments of Populus tremuloides (aspen tree) and Laccaria bicolor (mycorrhizal fungi) interaction and leveraged over 200 previously published transcriptomic experimental data sets, 159 experimentally validated plant transcription factor binding motifs, and more than 120-thousand experimentally validated protein-protein interactions to generate models of pre-mycorrhizal sensor systems in aspen root. These sensor mechanisms link extracellular signaling molecules with gene regulation through a network comprised of membrane receptors, signal cascade proteins, transcription factors, and transcription factor biding DNA motifs. Modeling predicted four pre-mycorrhizal sensor complexes in aspen that interact with fifteen transcription factors to regulate the expression of 1184 genes in response to extracellular signals synthesized by Laccaria. Predicted extracellular signaling molecules include common signaling molecules such as phenylpropanoids, salicylate, and, jasmonic acid. Lastly, this multi-omic computational modeling approach for predicting the complex sensory networks yielded specific, testable biological hypotheses for mycorrhizal interaction signaling compounds, sensor complexes, and mechanisms of gene regulation.

59 BASIC BIOLOGICAL SCIENCES↗

Report on Initial Sodium Testing on the Thermal Hydraulic Experimental Test Article (THETA) (Fiscal Year 2024 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as to acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal thermal hydraulic conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. In fiscal year 2023, thermal stratification tests were completed with the primary system online, while the secondary system was being constructed [1]. These tests had shown that the core barrel and intermediate heat exchanger (IHX) outlet required increased thermal insulation. The THETA primary system was removed from METL, cleaned, thermal insulators installed, and then inserted into METL Test Vessel 4. At the time of this writing the THETA primary and secondary system are operational. During this fiscal year 100+ hours of testing was completed to characterize thermal hydraulic phenomena associated with steady state and transient conditions in a pool type liquid metal cooled reactor. A majority of the testing campaign was completed to satisfy the experimental data acquisition requirements for the GAIN Voucher with Oklo, CRADA 2021-21121. THETA is still operational at the time of this publication and future testing is planned for fiscal year 2025. Work is underway to publish existing and future data to an online database to facilitate collaboration with SFR engineers looking to validate their systems code or computational fluid dynamics models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Boundary Layer Climatology at ARM Southern Great Plains

Operational since 1992, the Atmospheric Radiation Measurement (ARM) southern great plains (SGP) site at Oklahoma, USA has become a reference research site for meteorological studies. Due to an open data policy the ARM data are used by researchers all over the world. In this report, we review the long-term climatology of the atmospheric boundary layer, SGP instrumentations, the site and some site-specific atmospheric conditions which potentially effect wind turbines within the region. As the atmospheric boundary layer is bounded and influenced by the surface, observations of surface radiation components and heat fluxes are crucial in understanding land-atmosphere interactions. The entrainment of air, updrafts, downdrafts and boundary layer height characteristics is needed for understanding the structure and growth of the atmospheric boundary layer. Therefore, measurements from both surface in-situ and remote sensing observations at SGP provide an overall climatology and their interactions from surface up to the boundary layer. Measurements from a 60 m meteorological tower, surface flux stations, disdrometers, soil temperature and moisture flux plates, coherent Doppler lidar, Raman lidar, radiosondes, and satellite data at SGP central facility were analyzed. All the measurements were generally within a few square kilometers of each other at the central facility. This report focuses on data from January 2010 to June 2020 at SGP central facility. The various sections describe the ARM SGP site and surrounding wind turbines; in-situ and remote sensing instrumentation used in the report; provides mathematical equations to analyze fluxes, turbulence and other boundary layer parameters; a climatological analysis of surface winds, fluxes and thermodynamic parameters for several years; an analysis of observed winds in the framework of Monin-Obukhov Similarity Theory; an analysis of the boundary layer winds and direction from a Doppler lidar; multi-year turbulence estimates through the boundary layer from a Doppler lidar; atmospheric boundary layer water vapor and relative humidity profiles from Raman lidar; cloud base height and boundary layer height from multiple sensors and satellite data; and finally site specific atmospheric conditions, such as nocturnal low-level jets. Diurnal, seasonal and yearly variations of surface, sub-surface and boundary layer quantities, such as wind speed, direction, temperature, atmospheric stability, soil temperature, and various atmospheric fluxes at SGP showed distinct trends useful for focused modeling studies. The applicability of surface similarity theory on ARM SGP data is also evaluated, which showed northerly flows are aligned with MO theory estimates compared to southerly flows. Boundary layer winds and direction profiles for several years from a Doppler lidar shows a consistent presence of a nocturnal low-level jet and predominant southerly wind directions through the boundary layer at SGP. The inter-annual variability at SGP is low (<3.5%), with a mean annual wind speed of approximately 7 m s -1 at 100 m above ground level. Boundary layer turbulence and moisture transport from Doppler and Raman lidars are evaluated, which provides evidence of increased water vapor mass flux into the great plains during nocturnal low-level jets. The moisture flux from nocturnal low-level jets is observed to be maximum during summer periods. A novel machine learning algorithm is implemented to accurately estimate the planetary boundary layer height, providing further insights into growth and destruction of the convective boundary layer height during various seasons and land-atmosphere conditions. The high frequency of low-level clouds during winter, spring and fall seasons is validated using the multi-sensor array and satellite estimates of cloud top height. Satellite vegetative fraction data provides insight into seasonal surface roughness and vegetation variability around SGP site.

54 ENVIRONMENTAL SCIENCES↗

Using Micro-Synchrophasor Data for Advanced Distribution Grid Planning and Operations Analysis

This report reviews the potential for distribution-grid phase-angle data that will be available from new micro-synchrophasors (µPMUs) to be utilized in existing distribution-grid planning and operations analysis. This data could augment the current diagnostic capabilities of grid analysis software, used in both planning and operations for applications such as fault location, and provide data for more accurate modeling of the distribution system. µPMUs are new distribution-grid sensors that will advance measurement and diagnostic capabilities and provide improved visibility of the distribution grid, enabling analysis of the grid’s increasingly complex loads that include features such as large volumes of distributed generation. Large volumes of DG leads to concerns on continued reliable operation of the grid, due to changing power flow characteristics and active generation, with its own protection and control capabilities. Using µPMU data on change in voltage phase angle between two points in conjunction with new and existing distribution-grid planning and operational tools is expected to enable model validation, state estimation, fault location, and renewable resource/load characterization. Our findings include: data measurement is outstripping the processing capabilities of planning and operational tools; not every tool can visualize a voltage phase-angle measurement to the degree of accuracy measured by advanced sensors, and the degree of accuracy in measurement required for the distribution grid is not defined; solving methods cannot handle the high volumes of data generated by modern sensors, so new models and solving methods (such as graph trace analysis) are needed; standardization of sensor-data communications platforms in planning and applications tools would allow integration of different vendors’ sensors and advanced measurement devices. In addition, data from advanced sources such as µPMUs could be used to validate models to improve/ensure accuracy, providing information on normally estimated values such as underground conductor impedance, and characterization of complex loads. Although the input of high-fidelity data to existing tools will be challenging, µPMU data on phase angle (as well as other data from advanced sensors) will be useful for basic operational decisions that are based on a trend of changing data.

25 ENERGY STORAGE↗

In-process monitoring and prediction of droplet quality in droplet-on-demand liquid metal jetting additive manufacturing using machine learning

Abstract In droplet-on-demand liquid metal jetting (DoD-LMJ) additive manufacturing, complex physical interactions govern the droplet characteristics, such as size, velocity, and shape. These droplet characteristics, in turn, determine the functional quality of the printed parts. Hence, to ensure repeatable and reliable part quality it is necessary to monitor and control the droplet characteristics. Existing approaches for in-situ monitoring of droplet behavior in DoD-LMJ rely on high-speed imaging sensors. The resulting high volume of droplet images acquired is computationally demanding to analyze and hinders real-time control of the process. To overcome this challenge, the objective of this work is to use time series data acquired from an in-process millimeter-wave sensor for predicting the size, velocity, and shape characteristics of droplets in DoD-LMJ process. As opposed to high-speed imaging, this sensor produces data-efficient time series signatures that allows rapid, real-time process monitoring. We devise machine learning models that use the millimeter-wave sensor data to predict the droplet characteristics. Specifically, we developed multilayer perceptron-based non-linear autoregressive models to predict the size and velocity of droplets. Likewise, a supervised machine learning model was trained to classify the droplet shape using the frequency spectrum information contained in the millimeter-wave sensor signatures. High-speed imaging data served as ground truth for model training and validation. These models captured the droplet characteristics with a statistical fidelity exceeding 90%, and vastly outperformed conventional statistical modeling approaches. Thus, this work achieves a practically viable sensing approach for real-time quality monitoring of the DoD-LMJ process, in lieu of the existing data-intensive image-based techniques.

Gaikwad, Aniruddha (ORCID:0000000285642621)↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗