Search NASASearch

SEARCH · Search NASA

Results for “serialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Serial-femtosecond crystallography reveals how a phytochrome variant couples chromophore and protein structural changes

The photoreaction and commensurate structural changes of a chromophore within biological photoreceptors elicit conformational transitions of the protein promoting the switch between deactivated and activated states. We investigated how this coupling is achieved in a bacterial phytochrome variant, Agp2-PAiRFP2. Contrary to classical protein crystallography, which only allows probing (cryo-trapped) stable states, we have used time-resolved serial femtosecond x-ray crystallography (tr-SFX) and pump-probe techniques with various illumination and delay times with respect to photoexcitation of the parent Pfr state. Thus, structural data for seven time frames were sorted into groups of molecular events along the reaction coordinate. They range from chromophore isomerization to the formation of Meta-F, the intermediate that precedes the functional relevant secondary structure transition of the tongue. Structural data for the early events were used to calculate the photoisomerization pathway to complement the experimental data. Late events allow identifying the molecular switch that is linked to the intramolecular proton transfer as a prerequisite for the following structural transitions.

59 BASIC BIOLOGICAL SCIENCES

Parallel-to-serial biphase-data converter

Data converter produces a serial biphase output signal from parallel input data. Alternate bits are loaded into a shift register in complement form so that the bits appear at the end of the shift register in a true-complement form sequence.

Truelove, R. D.

Serial segment method for measuring remnant

For tracking tasks where a sum of sine waves forcing function is used it is often difficult and/or expensive to obtain the pilot's remnant in the vicinity of the sine waves. For the case where each sine wave has at least four times an integer number of cycle per run length, this paper illustrates the serial segments method for measuring remnant power spectral density in a frequency band centered on each sine wave. This method can be implemented on digital, hybrid, or analog Fourier coefficient analyzers, and is particularly advantageous on the latter since properties of Fourier coefficients are exploited to yield both a remnant measure and an improved estimate of the correlated component.

Magdaleno, R. E.

The restoration of obliterated stamped serial numbers by ultrasonically induced cavitation in water

Seventeen out of 21 obliterated stamped serial numbers on test specimens of copper, brass, steel, and aluminum were successfully restored. Cavitation induced in water by a piezoelectric transducer was the mechanism used. Primarily, smeared metal was removed from the number grooves by the force of the cavitation, however, numbers were also restored at depths at or below the level of the stamped grooves. The feasibility of this technique as a low cost tool for crime laboratories has been clearly demonstrated. The technique is applicable to a variety of materials, and no previous surface or chemical treatments are necessary.

Young, S. G.

Process to restore obliterated serial numbers on metal surfaces

Metal smeared into grooves of serial numbers by grinding or filing can be cleaned out by process called cavitation. Ultrasonic vibrator generates very high frequency vibrations in water which create millions of microscopic bubbles. Cavitation bubbles impact metal surface at thousands of pounds per square inch pressure. Metal particles filling grooves are broken away.

Young, S. G.

Acceptance test report (MI-74067-009-00). SVWS access arm (Serial number AA-09-03) (drawing 75M08129-13)

Acceptance tests were conducted at Kennedy Space Center of the Saturn Vehicle Workshop Spacecraft Access Arm and related equipment. The tests were conducted to prove complete system capability to operate satisfactorily under conditions required to support spacecraft operations and activities. The SVWS Access Arm, serial number AA-09-03, is a Command Module Service Arm, S/A 9, which was removed from the mobile launcher and modified to support the SVWS operations. The C/M environmental chamber was removed and a completely new chamber was installed. The retract system was redesigned to remove the automatic/remote control capability and replaced with a local manual control. The SVWS Access Arm System was successfully tested and supported spacecraft processing without major problems.

Hagood, J. T.

Star adaptation for two-algorithms used on serial computers

Two representative algorithms used on a serial computer and presently executed on the Control Data Corporation 6000 computer were adapted to execute efficiently on the Control Data STAR-100 computer. Gaussian elimination for the solution of simultaneous linear equations and the Gauss-Legendre quadrature formula for the approximation of an integral are the two algorithms discussed. A description is given of how the programs were adapted for STAR and why these adaptations were necessary to obtain an efficient STAR program. Some points to consider when adapting an algorithm for STAR are discussed. Program listings of the 6000 version coded in 6000 FORTRAN, the adapted STAR version coded in 6000 FORTRAN, and the STAR version coded in STAR FORTRAN are presented in the appendices.

Howser, L. M.

Manufacture and static firing of X259-E6 rocket motor serial number XJ04/0001

A single motor was cast and static fired to demonstrate the performance of high energy crosslinked double base (XLDB) propellant in standard X259 rocket motor hardware. Prior to motor fabrication, the motor was analyzed to predict the results of static firing the X259 motor loaded with XLDB propellant. As a result of the analyses, a forward dome shrinkage liner was added to the design. With this design change it was determined that adequate margins of safety existed. The motor, designated the X259-E6 model with serial number XJ04/0001, was fabricated using a slurry-casting technique and was assembled with a standard X259-B4 nozzle which had the nozzle throat machined to a smaller inside diameter than the B4 model and the exit cone cut short for Bacchus Works altitude expansion. The motor was static fired on 20 February 1974 with the nozzle failing during motor operation. Nozzle failure was attributed to spalling of the throat material leading to complete nozzle break-up. However, the propellant functioned as predicted in the motor chamber, ignition was normal, and char and erosion of the internal insulator were as expected.

Robertson, D. R.

Applications of the Ultrasonic Serial Number Restoration Technique to Guns and Typical Stolen Articles

An ultrasonic cavitation method for restoring obliterated serial numbers has been further explored by application to articles involved in police cases. The method was applied successfully to gun parts. In one case portions of numbers were restored after prior failure by other laboratories using chemical etching techniques. The ultrasonic method was not successful on a heavily obliterated and restamped automobile engine block, but it was partially successful on a motorcycle gear-case housing. Additional studies were made on the effect of a larger diameter ultrasonic probe, and on the method's ability to restore numbers obliterated by peening.

Young, S. G.

Assessment of left ventricular ejection fraction by radionuclide angiography. Comparison to echocardiography and serial measurements in patients with myocardial infarction

Measurements of the left ventricular ejection fraction were compared in patients with previous myocardial infarctions. Left ventricular ejection fraction was measured by the radioisotopic method serially in patients early after an acute myocardial infarction and during the convalescence period. Ultrasound recordings were obtained utilizing a commercially available ultrasonoscope and a 1/9 cm transducer focused at 10 cm with a repetition rate of 1000 impulses per second. All recordings were made on a visicorder oscillography.

Schelbert, H. R.