Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulation analytics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

STS crew escape for steady state gliding flight

The Space Transportation System goal of return to safe flight required that the Orbiter vehicle provide the crewmembers with a means of escape during controlled gliding flight. Because of its simplicity and safety the pole escape concept was selected for use during crew escape. To show that this concept would work in the Orbiter, wind tunnel tests, flight testing, and analytical simulation of the pole concept were pursued. This paper addresses each of these activities, showing how the wind tunnel test demonstrated the feasibility of the concept, how the flight testing was used to extract crew aero and Orbiter clearance margins, and how analytical simulations were used to verify Orbiter clearance margins. The analytical assessment of the Orbiter clearance margins shows that the pole concept will provide a minimum of 7-ft dispersed clearance for the NASA astronaut corps.

Millard, S. W.↗

On the stability of nongyrotropic ion populations - A first (analytic and simulation) assessment

The wave and dispersion equations for perturbations propagating parallel to an ambient magnetic field in magnetoplasmas with nongyrotropic ion populations show, in general, the occurrence of coupling between the parallel (left- and right-hand circularly polarized electromagnetic and longitudinal electrostatic) eigenmodes of the associated gyrotropic medium. These interactions provide a means to driving linearly one mode with free-energy sources of other modes in homogeneous media. Different types of nongyrotropy bring about distinct classes of coupling. The stability of a hydrogen magnetoplasma with anisotropic, nongyrotropic protons that only couple the electromagnetic modes to each other is investigated analytically (via solution of the derived dispersion equation) and numerically (via simulation with a hybrid code). Nongyrotropy enhances growth and enlarges the unstable spectral range relative to the corresponding gyrotropic situation. The relevance of the properties of nongyrotropic populations to space plasma environments is also discussed.

Brinca, A. L.↗

Reducing dielectric loss and enhancing electrical insulation for multilayer polymer films by nanoconfined ion transport under high poling electric fields

High temperature polar polymers have demonstrated potential for good thermal stability and high dielectric constant at the same time. However, polarization of contaminated impurity ions in polar polymers, even at the ppm level, can significantly increase the dielectric loss at high temperature and low frequencies. One effective strategy to mitigate this problem is to multilayer them with a high temperature nonpolar dielectric polymer to confine impurity ion transport at the nanometer scale. In this study, confined ion transport in high temperature polycarbonate (HTPC)/poly(vinylidene fluoride) (PVDF) multilayer films under high AC electric fields was studied using a direct analytical simulation method. Different from the ion transport under low fields, the ion diffusion model failed to describe the ion transport under high electric fields. An exponential ion distribution profile, which was observed for the DC poling situation, was employed to implement the direct analytical simulation. Confined impurity ion transport under high AC fields was quantitatively understood. As the AC field increased, the mobile ion concentration decreased whereas the diffusion coefficient increased. The decrease of mobile ion concentration was explained by the blockage of impurity ions by the HTPC layers. This knowledge helped in the determination of optimal conditions to polarize impurity ions from the PVDF layers into the HTPC layers. After cooling below the glass transition temperature of HTPC, polarized impurity ions were locked inside the HTPC layers. As a result, increased discharge efficiency and enhanced electrical insulation (i.e., increased dielectric breakdown strength) were achieved for the polarized multilayer films.

36 MATERIALS SCIENCE↗

Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study

Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicated image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30°, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at ∼0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as incorporated in the forward- and back-projection steps. Meanwhile, the developed MC model and the analytical simulator of the system can be applied for further studies on development and evaluation of the system.

60 APPLIED LIFE SCIENCES↗

Surrogate model for third-integer resonance extraction at the Fermilab Delivery Ring

We present an ongoing work in which a surrogate model is being developed to reproduce the response dynamics of the third-integer resonant extraction process in the Delivery Ring (DR) at Fermilab. This is in pursuit of smoothly extracting circulating beam to the Mu2e Experiment’s production target, whereby the goal is to extract a uniform slice of the circulating 1e12 protons in the DR over 25,000 turns (43 ms). The DR contains 3 harmonic sextupoles that excite a third-integer resonance and three fast, tune-ramping quadrupole magnets that drive the horizontal tune towards the 29/3 resonance. In our initial work, the surrogate model trains on a semi-analytical simulation provided in the same format as live data. Using Reinforcement Learning (and other potential ML methods), the trained surrogate acts as the “environment” in which a simple ML control agent could learn to dynamically adjust the quadrupole ramp at 430 break points within the 43 microsecond spill window. The controller will be hosted on a dedicated Arria 10 FPGA. In this work, we report the accuracy and fidelity of the surrogate model in comparison to the response dynamics of the physics simulator.

Narayanan, Aakaash [Fermilab]↗

Simulated scatter performance of an inverse-geometry dedicated breast CT system

The purpose of this work was to quantify the effects of scatter for inverse-geometry dedicated breast CT compared to cone-beam breast CT through simulations. The inverse geometry was previously proposed as an alternative to cone-beam acquisition for volumetric CT. The inverse geometry consists of a large-area scanned-source opposite a detector array that is smaller in the transverse direction. While the gantry rotates, the x-ray beam is rapidly sequenced through an array of positions, acquiring a truncated projection image at each position. Inverse-geometry CT (IGCT) is expected to detect less scatter than cone-beam methods because only a fraction of the object is irradiated at any time and the fast detector isolates the measurements from sequential x-ray beams. An additional scatter benefit is the increased air gap due to the inverted geometry. In this study, we modeled inverse-geometry and cone-beam dedicated breast CT systems of equivalent resolution, field of view, and photon fluence. Monte Carlo simulations generated scatter and primary projections of three cylindrical phantoms of diameters 10, 14, and 18 cm composed of 50% adipose/50% glandular tissue. The scatter-to-primary ratio (SPR) was calculated for each breast diameter. Monte Carlo simulations were combined with analytical simulations to generate inverse-geometry and cone-beam images of breast phantoms embedded with tumors. Noise representing the photon fluence of a realistic breast CT scan was added to the simulated projections. Cone-beam data were reconstructed with and without an ideal scatter correction. The CNR between breast tumor and background was compared for the inverse and cone-beam geometries for the three phantom diameters. Results demonstrated an order of magnitude reduction in SPR for the IGCT system compared to the cone-beam system. For example, the peak IGCT SPRs were 0.05 and 0.09 for the 14 and 18 cm phantoms, respectively, compared to 0.42 and 1 for the cone-beam system. For both geometries, the effects of scatter on contrast-to-noise ratio (CNR) were small for the 10 cm diameter phantom. The inverse-geometry improved the CNR by factors of 1.16 for the 14 cm phantom and 1.48 for the 18 cm phantom compared to a cone-beam acquisition without scatter correction. When an ideal scatter correction was applied to the cone-beam acquisition, the IGCT CNR improvements were 1.03 and 1.25 for the 14 and 18 cm phantoms. Overall, the results suggest that the inverse geometry may be advantageous for dedicated breast CT, an application that requires high-contrast resolution, spatial resolution, and dose efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Composite Analytic and Simulation Package or RFI (CASPR) on a coded channel

CASPR is an analysis package which determines the performance of a coded signal in the presence of Radio Frequency Interference (RFI) and Additive White Gaussian Noise (AWGN). It can analyze a system with convolutional coding, Reed-Solomon (RS) coding, or a concatenation of the two. The signals can either be interleaved or non-interleaved. The model measures the system performance in terms of either the E(sub b)/N(sub 0) required to achieve a given Bit Error Rate (BER) or the BER needed for a constant E(sub b)/N(sub 0).

Freedman, Jeff↗

TU-CD-207-01: Characterization of Breast Tissue Composition Using Spectral Mammography

Purpose: To investigate the feasibility of characterizing the chemical composition of breast tissue, in terms of water and lipid, by using spectral mammography in simulation and postmortem studies. Methods: Analytical simulations were performed to obtain low- and high-energy signals of breast tissue based on previously reported water, lipid, and protein contents. Dual-energy decomposition was used to characterize the simulated breast tissue into water and lipid basis materials and the measured water density was compared to the known value. In experimental studies, postmortem breasts were imaged with a spectral mammography system based on a scanning multi-slit Si strip photon-counting detector. Low- and high-energy images were acquired simultaneously from a single exposure by sorting the recorded photons into the corresponding energy bins. Dual-energy material decomposition of the low- and high-energy images yielded individual pixel measurements of breast tissue composition in terms of water and lipid thicknesses. After imaging, each postmortem breast was chemically decomposed into water, lipid and protein. The water density calculated from chemical analysis was used as the reference gold standard. Correlation of the water density measurements between spectral mammography and chemical analysis was analyzed using linear regression. Results: Both simulation and postmortem studies showed good linear correlation between the decomposed water thickness using spectral mammography and chemical analysis. The slope of the linear fitting function in the simulation and postmortem studies were 1.15 and 1.21, respectively. Conclusion: The results indicate that breast tissue composition, in terms of water and lipid, can be accurately measured using spectral mammography. Quantitative breast tissue composition can potentially be used to stratify patients according to their breast cancer risk.

60 APPLIED LIFE SCIENCES↗