Search NASA⌕ Search

SEARCH · Search NASA

Results for “slice sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dark Energy Survey year 1 results: the relationship between mass and light around cosmic voids

What are the mass and galaxy profiles of cosmic voids? In this paper, we use two methods to extract voids in the Dark Energy Survey (DES) Year 1 redMaGiC galaxy sample to address this question. We use either 2D slices in projection, or the 3D distribution of galaxies based on photometric redshifts to identify voids. For the mass profile, we measure the tangential shear profiles of background galaxies to infer the excess surface mass density. The signal-to-noise ratio for our lensing measurement ranges between 10.7 and 14.0 for the two void samples. We infer their 3D density profiles by fitting models based on N-body simulations and find good agreement for void radii in the range 15–85 Mpc. Comparison with their galaxy profiles then allows us to test the relation between mass and light at the 10 per cent level, the most stringent test to date. We find very similar shapes for the two profiles, consistent with a linear relationship between mass and light both within and outside the void radius. We validate our analysis with the help of simulated mock catalogues and estimate the impact of photometric redshift uncertainties on the measurement. Our methodology can be used for cosmological applications, including tests of gravity with voids. Finally, this is especially promising when the lensing profiles are combined with spectroscopic measurements of void dynamics via redshift-space distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

The SYRMEP Beamline of Elettra: Clinical Mammography and Bio-medical Applications

At the SYnchrotron Radiation for MEdical Physics (SYRMEP) beamline of Elettra Synchrotron Light Laboratory in Trieste (Italy), an extensive research program in bio-medical imaging has been developed since 1997. The core program carried out by the SYRMEP collaboration concerns the use of Synchrotron Radiation (SR) for clinical mammography with the aim of improving the diagnostic performance of the conventional technique. The first protocol with patients, started in 2006 has been completed at the end of 2009 and the data analysis is now in progress.Regarding applications different from clinical imaging, synchrotron X-ray computed microtomography (micro-CT) is the most used technique, both in absorption and phase contrast. A new software tool, Pore3D, has been developed to perform a quantitative morphological analysis on the reconstructed slices and to access textural information of the sample under study.

43 PARTICLE ACCELERATORS↗

TESTING HOMOGENEITY WITH GALAXY STAR FORMATION HISTORIES

Observationally confirming spatial homogeneity on sufficiently large cosmological scales is of importance to test one of the underpinning assumptions of cosmology, and is also imperative for correctly interpreting dark energy. A challenging aspect of this is that homogeneity must be probed inside our past light cone, while observations take place on the light cone. The star formation history (SFH) in the galaxy fossil record provides a novel way to do this. We calculate the SFH of stacked luminous red galaxy (LRG) spectra obtained from the Sloan Digital Sky Survey. We divide the LRG sample into 12 equal-area contiguous sky patches and 10 redshift slices (0.2 < z < 0.5), which correspond to 120 blocks of volume {approx}0.04 Gpc{sup 3}. Using the SFH in a time period that samples the history of the universe between look-back times 11.5 and 13.4 Gyr as a proxy for homogeneity, we calculate the posterior distribution for the excess large-scale variance due to inhomogeneity, and find that the most likely solution is no extra variance at all. At 95% credibility, there is no evidence of deviations larger than 5.8%.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating multi-slice ptychography tomography for X-ray imaging

X-ray ptychography typically relies on single-slice reconstruction approaches that assume minimal beam propagation through the specimen. However, this approximation breaks down for thick samples or when using high numerical aperture optics, leading to reconstruction artifacts due to multiple scattering. Multi-slice ptychographic tomography (MSPT) addresses this limitation by explicitly modeling beam propagation through the specimen while reducing angular sampling requirements for tomography, but its performance depends critically on reconstruction parameters and experimental conditions. Here, we systematically evaluate MSPT using numerical simulations and experimental X-ray datasets to understand how factors such as object thickness, optical parameters, and initialization strategies affect reconstruction accuracy. We demonstrate that informed object initialization significantly improves depth resolution and enables accurate projection extension, reducing the angular sampling requirements for tomographic reconstruction. Experimental demonstration confirms that MSPT produces reconstructions with reduced artifacts, establishing it as a robust approach for nanoscale imaging at modern synchrotron facilities.

Luktuke, Amey [Argonne National Laboratory (ANL), ↗

The bias of a two‐dimensional view: comparing two‐dimensional and three‐dimensional mesophyll surface area estimates using noninvasive imaging

Summary The mesophyll surface area exposed to intercellular air space per leaf area ( S m ) is closely associated with CO 2 diffusion and photosynthetic rates. S m is typically estimated from two‐dimensional (2D) leaf sections and corrected for the three‐dimensional (3D) geometry of mesophyll cells, leading to potential differences between the estimated and actual cell surface area. Here, we examined how 2D methods used for estimating S m compare with 3D values obtained from high‐resolution X‐ray microcomputed tomography (microCT) for 23 plant species, with broad phylogenetic and anatomical coverage. Relative to 3D, uncorrected 2D S m estimates were, on average, 15–30% lower. Two of the four 2D S m methods typically fell within 10% of 3D values. For most species, only a few 2D slices were needed to accurately estimate S m within 10% of the whole leaf sample median. However, leaves with reticulate vein networks required more sections because of a more heterogeneous vein coverage across slices. These results provide the first comparison of the accuracy of 2D methods in estimating the complex 3D geometry of internal leaf surfaces. Because microCT is not readily available, we provide guidance for using standard light microscopy techniques, as well as recommending standardization of reporting S m values.

Théroux‐Rancourt, Guillaume↗

ODIN: Spectroscopic Validation of Lyα-emitting Galaxy Samples with DESI

The One-hundred-deg$^{2}$ DECam Imaging in Narrowbands (ODIN) survey is conducting the widest-field deep narrowband (NB) imaging of the equatorial and southern skies. ODIN uses three custom-built NB filters that sample Lyα-emitting galaxies (LAEs) within thin cosmic slices centered at z = 2.4, 3.1, and 4.5. In this work, we utilize extensive DESI spectroscopy of ODIN-selected galaxies in the COSMOS and XMM-LSS fields to validate our LAE selection. Exposures of 2-4 hr with DESI yielded redshift confirmation of 3075 ODIN LAE candidates with NB magnitudes brighter than 26 mag. Restricting to objects that yield high-confidence redshifts, the confirmation rates are (93%, 96%, 92%) at z = (2.4, 3.1, 4.5). The primary contaminants consist of active galactic nuclei at the expected Lyα-redshift range and lower redshifts (C iv , C iii ]), with the remainder being star-forming galaxies ([O ii ] and [O iii ]). We find minimal contamination from [O ii ] emitters in our sample (≲1%), implying that our rest-frame equivalent width (REW) > 20 Å NB excess photometry requirement is sufficient to remove them.

Pinarski, Ethan [Purdue U., West Lafayette] (ORCID↗

High-energy magnetic excitations in overdoped La 2-x Sr x CuO 4 studied by neutron and resonant inelastic X-ray scattering

We have performed neutron inelastic scattering and resonant inelastic x-ray scattering (RIXS) at the Cu-L 3 edge to study high-energy magnetic excitations at energy transfers of more than 100 meV for overdoped La 2₋x Sr x CuO 4 with x=0.25 (T c =15 K) and x=0.30 (nonsuperconducting) using identical single-crystal samples for the two techniques. From constant-energy slices of neutron-scattering cross sections, we have identified magnetic excitations up to ~250 meV for x=0.25. Although the width in the momentum direction is large, the peak positions along the (π,π) direction agree with the dispersion relation of the spin wave in the nondoped La 2 CuO 4 (LCO), which is consistent with the previous RIXS results of cuprate superconductors. Using RIXS at the Cu-L 3 edge, we have measured the dispersion relations of the so-called paramagnon mode along both (π,π) and (π,0) directions. Although in both directions the neutron and RIXS data connect with each other and the paramagnon along (π,0) agrees well with the LCO spin-wave dispersion, the paramagnon in the (π,π) direction probed by RIXS appears to be less dispersive and the excitation energy is lower than the spin wave of LCO near (π/2,π/2). Thus, our results indicate consistency between neutron inelastic scattering and RIXS, and elucidate the entire magnetic excitation in the (π,π) direction by the complementary use of two probes. The polarization dependence of the RIXS profiles indicates that appreciable charge excitations exist in the same energy range of magnetic excitations, reflecting the itinerant character of the overdoped sample. Lastly, we find a possible anisotropy in the charge excitation intensity might explain the apparent differences in the paramagnon dispersion in the (π,π) direction as detected by the x-ray scattering.

36 MATERIALS SCIENCE↗

Inferring Viral Transmission Time from Phylogenies for Known Transmission Pairs

When the time of an HIV transmission event is unknown, methods to identify it from virus genetic data can reveal the circumstances that enable transmission. We developed a single-parameter Markov model to infer transmission time from an HIV phylogeny constructed of multiple virus sequences from people in a transmission pair. Our method finds the statistical support for transmission occurring in different possible time slices. We compared our time-slice model results to previously described methods: a tree-based logical transmission interval, a simple parsimony-like rules-based method, and a more complex coalescent model. Across simulations with multiple transmitted lineages, different transmission times relative to the source’s infection, and different sampling times relative to transmission, we found that overall our time-slice model provided accurate and narrower estimates of the time of transmission. We also identified situations when transmission time or direction was difficult to estimate by any method, particularly when transmission occurred long after the source was infected and when sampling occurred long after transmission. Applying our model to real HIV transmission pairs showed some agreement with facts known from the case investigations. We also found, however, that uncertainty on the inferred transmission time was driven more by uncertainty from time calibration of the phylogeny than from the model inference itself. Encouragingly, comparable performance of the Markov time-slice model and the coalescent model—which make use of different information within a tree—suggests that a new method remains to be described that will make full use of the topology and node times for improved transmission time inference.

59 BASIC BIOLOGICAL SCIENCES↗

Ultra-broadband infrared pump-probe spectroscopy using synchrotron radiation and a tuneable pump

Synchrotron infrared sources have become popular mainly because of their excellent broadband brilliance, which enables spectroscopically resolved spatial-mapping of stationary objects at the diffraction limit. In this article we focus on an often-neglected further advantage of such sources - their unique time-structure - to bring such broadband spectroscopy to the time domain, for studying dynamic phenomenon down to the 100 ps limit. We describe the ultra-broadband (12.5 to 1.1 {mu}m) Fourier transform pump-probe setup, for condensed matter transmission- and reflection-spectroscopy, installed at the X01DC infrared beam-line of the Swiss Light Source (SLS). The optical pump consists of a widely tuneable 100 ps 1 kHz laser system, covering 94% of the 16 to 1.1 {mu}m range. A thorough description of the system is given, including (i) the vector-modulator providing purely electronic tuning of the pump-probe overlap up to 1 ms with sub-ps time resolution, (ii) the 500 MHz data acquisition system interfaced with the experimental physics and industrial control system (EPICS) based SLS control system for consecutive pulse sampling, and (iii) the step-scan time-slice Fourier transform scheme for simultaneous recording of the dual-channel pumped, un-pumped, and difference spectra. The typical signal/noise ratio of a single interferogram in a 100 ps time slice is 300 (measured during one single 140 s TopUp period). This signal/noise ratio is comparable to that of existing gated Globar pump-probe Fourier transform spectroscopy, but brings up to four orders of magnitude better time resolution. To showcase the utility of broadband pump-probe spectroscopy, we investigate a Ge-on-Si material system similar to that in which optically pumped direct-gap lasing was recently reported. We show that the mid-infrared reflection-spectra can be used to determine the optically injected carrier density, while the mid- and near-infrared transmission-spectra can be used to separate the strong pump-induced absorption and inversion processes present at the direct-gap energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron-Based Micro-CT Imaging of the Human Lung Acinus

Structural data about the human lung fine structure are mainly based on stereological methods applied to serial sections. As these methods utilize 2D images, which are often not contiguous, they suffer from inaccuracies which are overcome by analysis of 3D micro-CT images of the never-sectioned specimen. The purpose of our study was to generate a complete data set of the intact three-dimensional architecture of the human acinus using high-resolution synchrotron-based micro-CT (synMCT). A human lung was inflation-fixed by formaldehyde ventilation and then scanned in a 64-slice CT over its apex to base extent. Lung samples (8-mm diameter, 10-mm height, N = 12) were punched out, stained with osmium tetroxide, and scanned using synMCT at (4 {micro}m){sup 3} voxel size. The lung functional unit (acinus, N = 8) was segmented from the 3D tomographic image using an automated tree-analysis software program. Morphometric data of the lung were analyzed by ANOVA. Intra-acinar airways branching occurred over 11 generations. The mean acinar volume was 131.3 {+-} 29.2 mm{sup 3} (range, 92.5-171.3 mm{sup 3}) and the mean acinar surface was calculated with 1012 {+-} 26 cm{sup 2}. The airway internal diameter (starting from the bronchiolus terminalis) decreases distally from 0.66 {+-} 0.04 mm to 0.34 {+-} 0.06 mm (P < 0.001) and remains constant after the seventh generation (P < 0.5). The length of each generation ranges between 0.52 and 0.93 mm and did not show significant differences between the second and eleventh generation. The branching angle between daughter branches varies between 113-degree and 134-degree without significant differences between the generations (P < 0.3). This study demonstrates the feasibility of quantitating the 3D structure of the human acinus at the spatial resolution readily achievable using synMCT.

59 BASIC BIOLOGICAL SCIENCES↗

A robust and efficient approach to detect 3D rectal tubes from CT colonography

Purpose: The rectal tube (RT) is a common source of false positives (FPs) in computer-aided detection (CAD) systems for CT colonography. A robust and efficient detection of RT can improve CAD performance by eliminating such ''obvious'' FPs and increase radiologists' confidence in CAD. Methods: In this paper, we present a novel and robust bottom-up approach to detect the RT. Probabilistic models, trained using kernel density estimation on simple low-level features, are employed to rank and select the most likely RT tube candidate on each axial slice. Then, a shape model, robustly estimated using random sample consensus (RANSAC), infers the global RT path from the selected local detections. Subimages around the RT path are projected into a subspace formed from training subimages of the RT. A quadratic discriminant analysis (QDA) provides a classification of a subimage as RT or non-RT based on the projection. Finally, a bottom-top clustering method is proposed to merge the classification predictions together to locate the tip position of the RT. Results: Our method is validated using a diverse database, including data from five hospitals. On a testing data with 21 patients (42 volumes), 99.5% of annotated RT paths have been successfully detected. Evaluated with CAD, 98.4% of FPs caused by the RT have been detected and removed without any loss of sensitivity. Conclusions: The proposed method demonstrates a high detection rate of the RT path, and when tested in a CAD system, reduces FPs caused by the RT without the loss of sensitivity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IV Administered Gadodiamide Enters the Lumen of the Prostatic Glands: X-Ray Fluorescence Microscopy Examination of a Mouse Model

In our objective, we descibe how dynamic contrast-enhanced MRI (DCE-MRI) has become a standard component of multiparametric protocols for MRI examination of the prostate, and its use is incorporated into current guidelines for prostate MRI examination. Analysis of DCE-MRI data for the prostate is usually based on the distribution of gadolinium-based agents, such as gadodiamide, into two well-mixed compartments, and it assumes that gadodiamide does not enter into the glandular lumen. However, this assumption has not been directly tested. The purpose of this study was to use x-ray fluorescence microscopy (XFM) imaging in situ to measure the concentration of gadodiamide in the epithelia and lumens of the prostate of healthy mice after IV injection of the contrast agent. For our materials and methods, six C57Bl6 male mice (age, 28 weeks) were sacrificed 10 minutes after IV injection of gadodiamide (0.13 mmol/kg), and three mice were sacrificed after saline injection. Prostate tissue samples obtained from each mouse were harvested and frozen; 7-μm-thick slices were sectioned for XFM imaging, and adjacent 5-μm-thick slices were sectioned for H and E staining. Elemental concentrations were determined from XFM images. Our results show mean (± SD) baseline concentration of gadolinium of 0.01 ± 0.01 mM was determined from XFM measurements of prostatic tissue samples when no gadodiamide was administered, and it was used to determine the measurement error. When gadodiamide was added, the mean concentrations of gadolinium in the epithelia and lumens in 32 prostatic glands from six mice were 1.00 ± 0.13 and 0.36 ± 0.09 mM, respectively. In conclusion, our data suggest that IV administration of gadodiamide results in uptake of contrast agent by the glandular lumens of the mouse prostate. We were able to quantitatively determine gadodiamide distributions in mouse prostatic epithelia and lumens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-14: A Novel Approach to Evaluate the Dosimetric Effect of Rectal Variation During Image Guided Prostate Radiotherapy

Purpose: Deformable registration establishes the spatial correspondence back to the reference image in order to accumulate dose. However, in prostate radiotherapy the changing shape and volume of the rectum present a challenge to accurate deformable registration and consequently calculation of delivered dose. We explored an alternative approach to calculating accumulated dose to the rectum, independent of deformable registration. Methods: This study was performed on three patients who received online image-guided radiotherapy (IGRT) with daily CBCT (XVI-system,Elekta) and target localization using intraprostatic fiducials. On each CBCT, the rectum was manually contoured and bulk density assignments were made allowing dose to be calculated for each fraction. Dose-surface maps (DSM) were generated (MATLAB,Mathworks,Natick,MA) by considering the rectum as a cylinder and sampling the dose at 21-equispaced points on each CT slice. The cylinder was “cut” at the posterior-most position on each CT and unfolded to generate a DSM. These were normalised in the longitudinal direction by interpolation creating maps of 21×21 pixels. A DSM was produced for each CBCT and the dose was accumulated. Results: The mean accumulated delivered rectal surface dose was on average 7.5(+/−3.5)% lower than the planned dose. The dose difference maps consistently show that the greatest variation in dose between planned and delivered dose is away from where the rectal surface is adjacent to the prostate. Conclusion: Estimation of dose accumulation using DSM provides an alternative method for determining actual delivered dose to the rectum. The dose difference is greatest in areas away from the region where the rectal surface abuts the prostate, the region where set-up is verified. The change in size and shape of the rectum was shown to resultin a change in the accumulated dose compared to the planned dose and this will have an impact on determining the relationships between dose delivered and toxicity. We acknowledge funding from CRUK and acknowledge NHS funding to the NIHR Biomedical Research Centre for Cancer. Patients were treated within the CHHiP IGRT sub-study (CRUK/06/016, ISRCTN:97182923) funded by CRUK. RayStation was used under an evaluation agreement with RaySearch Laboratories AB.

60 APPLIED LIFE SCIENCES↗

Microsecond fingerprint stimulated Raman spectroscopic imaging by ultrafast tuning and spatial-spectral learning

Label-free vibrational imaging by stimulated Raman scattering (SRS) provides unprecedented insight into real-time chemical distributions. Specifically, SRS in the fingerprint region (400–1800 cm -1 ) can resolve multiple chemicals in a complex bio-environment. However, due to the intrinsic weak Raman cross-sections and the lack of ultrafast spectral acquisition schemes with high spectral fidelity, SRS in the fingerprint region is not viable for studying living cells or large-scale tissue samples. Here, we report a fingerprint spectroscopic SRS platform that acquires a distortion-free SRS spectrum at 10 cm -1 spectral resolution within 20 µs using a polygon scanner. Meanwhile, we significantly improve the signal-to-noise ratio by employing a spatial-spectral residual learning network, reaching a level comparable to that with 100 times integration. Collectively, our system enables high-speed vibrational spectroscopic imaging of multiple biomolecules in samples ranging from a single live microbe to a tissue slice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of low angle grain boundaries in lightly deformed superconducting niobium and their influence on hydride distribution and flux perturbation

This study shows that low angle grain boundaries (LAGBs) can be created by small 5% strains in high purity (RRR ≥ 200) SRF-grade single crystalline niobium (Nb) and that these boundaries act as hydrogen traps as indicated by the distribution of niobium hydrides (Nb 1-x H x ). Nb 1-x H x is detrimental to superconducting radio frequency (SRF) Nb cavities due to its normal conducting properties at cavity operating temperatures. By designing a single crystal tensile sample extracted from a large grain (>5 cm) Nb ingot slice for preferred slip on one slip plane, LAGBs and dense dislocation boundaries developed. With chemical surface treatments following standard SRF cavity fabrication practice, Nb1-xHx phases were densely precipitated at the LAGBs upon cryogenic cooling (8-10 K/min). Micro-crystallographic analysis confirmed heterogeneous hydride precipitation, which included significant hydrogen atom accumulation in LAGBs. Magneto-optical imaging (MOI) analysis showed that these sites can then act as sites for both premature flux penetration and eventually flux trapping. However, this hydrogen related degradation at LAGBs did not completely disappear even after a 800 °C/2hrs anneal typically used for hydrogen removal in SRF Nb cavities. These findings suggest that hydride precipitation at a LAGB is facilitated by a non-equilibrium concentration of vacancy-hydrogen (H) complexes aided by mechanical deformation and the hydride phase interferes with the recovery process under 800°C annealing.

36 MATERIALS SCIENCE↗

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics↗

SU-G-IeP3-07: High-Resolution, High-Sensitivity Imaging and Quantification of Intratumoral Distributions of Gold Nanoparticles Using a Benchtop L-Shell XRF Imaging System

Purpose: To demonstrate the ability to perform high-resolution imaging and quantification of sparse distributions of gold nanoparticles (GNPs) within ex vivo tumor samples using a highly-sensitive benchtop L-shell x-ray fluorescence (XRF) imaging system. Methods: An optimized L-shell XRF imaging system was assembled using a tungsten-target x-ray source (operated at 62 kVp and 45 mA). The x-rays were filtered (copper: 0.08 mm & aluminum: 0.04 mm) and collimated (lead: 5 cm thickness, 3 cm aperture diameter) into a cone-beam in order to irradiate small samples or objects. A collimated (stainless steel: 4 cm thickness, 2 mm aperture diameter) silicon drift detector, capable of 2D translation, was placed at 90° with respect to the beam to acquire XRF/scatter spectra from regions of interest. Spectral processing involved extracting XRF signal from background, followed by attenuation correction using a Compton scatter-based normalization algorithm. Calibration phantoms with water/GNPs (0 and 0.00001–10 mg/cm{sup 3}) were used to determine the detection limit of the system at a 10-second acquisition time. The system was then used to map the distribution of GNPs within a 12×11×2 mm{sup 3} slice excised from the center of a GNP-loaded ex vivo murine tumor sample; a total of 110 voxels (2.65×10{sup −3} cm{sup 3}) were imaged with 1.3-mm spatial resolution. Results: The detection limit of the current cone-beam benchtop L-shell XRF system was 0.003 mg/cm{sup 3} (3 ppm). Intratumoral GNP concentrations ranging from 0.003 mg/cm{sup 3} (3 ppm) to a maximum of 0.055 mg/cm{sup 3} (55 ppm) and average of 0.0093 mg/cm{sup 3} (9.3 ppm) were imaged successfully within the ex vivo tumor slice. Conclusion: The developed cone-beam benchtop L-shell XRF imaging system can immediately be used for imaging of ex vivo tumor samples containing low concentrations of GNPs. With minor finetuning/optimization, the system can be directly adapted for performing routine preclinical in vivo imaging tasks. Supported by NIH/NCI grant R01CA155446 This investigation was supported by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

SU-F-J-102: Lower Esophagus Margin Implications Based On Rapid Computational Algorithm for SBRT

Purpose: To quantify inter-fraction esophagus-variation. Methods: Computed tomography and daily on-treatment 0.3-T MRI data sets for 7 patients were analyzed using a novel Matlab-based (Mathworks, Natick, MA) rapid computational method. Rigid registration was performed from the cricoid to the gastro-esophageal junction. CT and MR-based contours were compared at slice intervals of 3mm. Variation was quantified by “expansion,” defined as additional length in any radial direction from CT contour to MR contour. Expansion computations were performed with 360° of freedom in each axial slice. We partitioned expansions into left anterior, right anterior, right posterior, and left posterior quadrants (LA, RA, RP, and LP, respectively). Sample means were compared by analysis of variance (ANOVA) and Fisher’s Protected Least Significant Difference test. Results: Fifteen fractions and 1121 axial slices from 7 patients undergoing SBRT for primary lung cancer (3) and metastatic lung disease (4) were analyzed, generating 41,970 measurements. Mean LA, RA, RP, and LP expansions were 4.30±0.05 mm, 3.71±0.05mm, 3.17±0.07, and 3.98±0.06mm, respectively. 50.13% of all axial slices showed variation > 5 mm in one or more directions. Variation was greatest in lower esophagus with mean LA, RA, RP, and LP expansion (5.98±0.09 mm, 4.59±0.09 mm, 4.04±0.16 mm, and 5.41±0.16 mm, respectively). The difference was significant compared to mid and upper esophagus (p<.0001). The 95th percentiles of expansion for LA, RA, RP, LP were 13.36 mm, 9.97 mm, 11.29 mm, and 12.19 mm, respectively. Conclusion: Analysis of on-treatment MR imaging of the lower esophagus during thoracic SBRT suggests margin expansions of 13.36 mm LA, 9.97 mm RA, 11.29 mm RP, 12.19 mm LP would account for 95% of measurements. Our novel algorithm for rapid assessment of margin expansion for critical structures with 360° of freedom in each axial slice enables continuously adaptive patient-specific margins which may reduce overlap with high-dose regions.

60 APPLIED LIFE SCIENCES↗