Search NASA⌕ Search

SEARCH · Search NASA

Results for “small sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Towards Realistic and High Fidelity Models for Nuclear Reactor Power Synthesis Simulation with Self-Powered Neutron Detectors

As presented in this report, a weighting function–based inferencing method is being applied to synthesize the power distribution in next-generation and university research reactors based on simulated self power neutron detector (SPND) responses. The overall goal is to assess the impacts of sensor uncertainty and true power distribution perturbations on the error in the synthesized power distribution. Regarding sensor uncertainty, the NuScale Small Modular Reactor (SMR) and the Westinghouse AP1000 serve as testbeds for analyzing the impact of varying the sensor uncertainty, as well as varying the number of sensors per sensor string in the reactor core. The reactor models are informed by Monte Carlo N-Particle (MCNP) neutron flux tallies. For the NuScale SMR and Westinghouse AP1000, the SPND response functions (i.e., the response of the SPNDs to individual segments of fuel) were determined homogeneously. Regarding an analysis of power distribution perturbation detection, the Texas A&M Testing, Research, Isotopes, General Atomics Reactor (TAMU TRIGA) reactor was used as a demonstration case with one particular arrangement of SPNDs; the response functions for this reactor model were determined heterogeneously, making this a uniquely high-fidelity demonstration of perturbation detection. Finally, SPND models generated in the Geometry and Tracking 4 (Geant4) code have been generated and tested for comparison with traditionally implemented analytical SPND models, with the intent for Geant4 integration with the full methodological framework. SPND current outputs as a function of distance from some fuel assembly segment in the NuScale SMR are compared with the analytically determined currents. Results from the sensor uncertainty simulations for the NuScale SMR and AP1000 indicate that the average error in the inferred power distribution on the fuel assembly segment level is reasonably low, being slightly less than the random uncertainty applied to all respective SPNDs in both cores. For example, if all SPNDs in the core have a random uncertainty of 5%, then the corresponding fuel assembly segment level error (i.e. difference between the true and inferred local power) is ~2–3%. However, the maximum error in the inferred power distribution on the fuel assembly segment level can be considerably high (>15%) when SPND random uncertainties start to exceed ~3%. In general, the average and maximum errors in the inferred power distribution were slightly higher in the AP1000 as opposed to the NuScale SMR for the sensor string configurations considered herein. Another result determined from analysis of the sensor uncertainty simulations was that increasing the number of SPNDs per string does not clearly reduce inferred power distribution error and can in fact make the error large in some cases; however, this assessment may skewed due to imposed iteration limits. Results from the perturbation detection demonstration using the high-fidelity TAMU TRIGA model indicate that, given the arrangement of 17 SPND strings and 4 SPNDs per string considered herein, there is a clear, provable ability to infer a localized Gaussian-type peak perturbation in the 3D power distribution. Such a perturbation was detected with an average fuel assembly segment level error of 0.19%, and the general visualization of the detected perturbation clearly indicates that the magnitude and shape were appropriately resolved. Finally, the electrical current output generated by the Geant4 modeled SPND indicates significant magnitude differences than the analytically modeled SPND, demonstrating the need for accurate SPND models which account for finite sensor geometry effects to inform the power synthesis work described herein.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Remote Sensing Low Signal-to-Noise-Ratio Target Detection Enhancement

In real-time remote sensing application, frames of data are continuously flowing into the processing system. The capability of detecting objects of interest and tracking them as they move is crucial to many critical surveillance and monitoring missions. Detecting small objects using remote sensors is an ongoing, challenging problem. Since object(s) are located far away from the sensor, the target’s Signal-to-Noise-Ratio (SNR) is low. The Limit of Detection (LOD) for remote sensors is bounded by what is observable on each image frame. In this paper, we present a new method, a “Multi-frame Moving Object Detection System (MMODS)”, to detect small, low SNR objects that are beyond what a human can observe in a single video frame. This is demonstrated by using simulated data where our technology-detected objects are as small as one pixel with a targeted SNR, close to 1:1. We also demonstrate a similar improvement using live data collected with a remote camera. The MMODS technology fills a major technology gap in remote sensing surveillance applications for small target detection. Our method does not require prior knowledge about the environment, pre-labeled targets, or training data to effectively detect and track slow- and fast-moving targets, regardless of the size or the distance.

47 OTHER INSTRUMENTATION↗

The Contact Stress Sensor _ Proposal to the FY2020 Technology Tech Mat Grants Program

The technology to be advanced is a very small and thin Contact Stress Sensor (CSS) that measures the contact stress between two contacting surfaces. It will be used to monitor the internal condition of a weapon in the stockpile over periods of decades. Monitoring the load path of a complex weapon assembly offers an important verification of the weapon’s mechanical state in both quasi-static or dynamic environments. Concurrently, the sensor can be used to measure temperature. This is useful for sensor calibration while installed in a system, as well as thermal monitoring in regions of the system that are difficult to access. Thus, the CSS is one way to monitor the internal “health” of a weapon. A sensor is shown below with each sensor being less then 2mm in width and 125 microns in thickness.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Simulation and Experimental Results of Interdigital Capacitor (IDC) Sensors to Monitor Insulation Degradation of Cables

The efficacy of using interdigital capacitor (IDC) sensors to monitor cable insulation aging was studied through electromagnetic simulations and experimental measurements. Simulation results on both planar and conformal dielectric materials indicated that IDCs on thin substrates and with conducting backplanes provide superior performance in terms of higher capacitance. An airgap study showed that even a very small airgap between the sensor and the cable’s insulation results in significant reduction in capacitance; therefore, airgaps should be minimized. Finally, cables that underwent accelerated aging exposure in an oven were tested using fabricated IDC sensors. Measurement results showed a 12.5% increase in capacitance when the IDC was pressed against the insulation versus a 91.3% increase in capacitance when the IDC was pressed against the jackets of the cables for cable specimens ranging from unaged to aged 35 days.

Cable NDE, Interdigital Capacitance↗

Remote sensing detection enhancement

Big Data in the area of Remote Sensing has been growing rapidly. Remote sensors are used in surveillance, security, traffic, environmental monitoring, and autonomous sensing. Real-time detection of small moving targets using a remote sensor is an ongoing, challenging problem. Since the object is located far away from the sensor, the object often appears too small. The object’s signal-to-noise-ratio (SNR) is often very low. Occurrences such as camera motion, moving backgrounds (e.g., rustling leaves), low contrast and resolution of foreground objects makes it difficult to segment out the targeted moving objects of interest. Due to the limited appearance of the target, it is tough to obtain the target’s characteristics such as its shape and texture. Without these characteristics, filtering out false detections can be a difficult task. Detecting these targets, would often require the detector to operate under a low detection threshold. However, lowering the detection threshold could lead to an increase of false alarms. In this paper, the author will introduce a new method that improves the probability to detect low SNR objects, while decreasing the number of false alarms as compared to using the traditional baseline detection technique.

47 OTHER INSTRUMENTATION↗

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

Inferring UAV Position Relative to Smartphone Sensor Based on Acoustic Characteristics

As commercial and non-commercial unmanned aerial vehicles (UAVs) improve technologically and increase in accessibility, their potential for use in actions antithetical to nuclear non-proliferation efforts increases as well. The ability to identify and locate UAVs using ubiquitous, inexpensive hardware and software would be advantageous as both a deterrent and an initial warning system. Our team looks to utilize smartphones as acoustic sensors to record and characterize UAV movement based on the sound produced while in flight. Multi-rotor UAVs produce identifiable acoustic spectral characteristics with frequencies and harmonics corresponding to motor revolutions per minute and the propeller characteristics. As the source moves closer to the receiver these spectral patterns remain relatively stable (at slow speeds), while the energy observed from the waves increases. The goal of this work is to utilize a small network of smartphone sensors with known, fixed positions to infer the relative position of an in-flight UAV with respect to the position of the smartphones through the variation in acoustic energy.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Design and Validation of a Cryogenic Dilatometer

This project focuses on the design and development of a cryogenic dilatometer capable of measuring the thermal expansion of materials at extremely low temperatures. Understanding how materials change dimension with temperature is critical for applications involving cryogenic environments, particularly laminated systems housing superconducting magnets, where small dimensional changes can significantly affect performance and reliability. To address this, a dilatometer system was designed to operate within a liquid nitrogen environment while accurately measuring displacements caused by thermal contraction. The purpose of this device is to determine the coefficient of thermal expansion (CTE) of a material. The design process involved defining functional requirements, developing mechanical and thermal concepts for the measurement apparatus, selecting appropriate materials compatible with cryogenic temperatures, and integrating sensors capable of detecting small dimensional changes. The resulting system aims to provide a practical and repeatable method for evaluating material thermal expansion at cryogenic temperatures, supporting research into composite use in superconducting applications that require accurate characterization of material behavior in low-temperature environments.

Schmitt, Nicholas [Northern Illinois U.]↗

Drone Video Platform—Collision Avoidance, Situational Awareness, and Communications

Small unmanned aerial systems are ideal for delivering sensors into areas that are inaccessible or too dangerous for human entry or manned aircraft over-flights. The systems can fly low and slow for enhanced sensitivity and in tight spaces where ordinary aircraft could never fit. We have configured and flown sensor payloads for radiation, chemical, and optical detection on small fixed-wing and rotary-wing aircraft. All the sensor packages provide telemetry, GPS coordinates, LIDAR distance ranging, and absolute time of day to microsecond accuracy. Payload weights range from less than 1 kg up to 5.5 kg. Currently, communications are over 2.4 GHz and 915 MHz radios, as well as over 4G LTE cellular data links. Real-time data feeds from the sensor payloads to web browser clients anywhere in the world are possible via a virtual EC2 server on the Amazon AWS cloud. In FY 2019, the Nevada National Security Site teamed with Virginia Tech, H3D Corp., and Unmanned Systems, Inc. to accomplish the four flight missions described in this report. A large part of this year’s mission goals were to demonstrate the ability to fly beyond visual line of sight (BVLOS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Arrays of Functionalized Graphene Chemiresistors for Selective Sensing of Volatile Organic Compounds

Real-time detection of volatile organic compounds (VOCs) is being spotlighted for its importance in environmental monitoring and disease detection from the breath. However, the selective detection of VOCs in a small form factor gas sensor remains a challenge. Here, we present the VOC sensing performance of phthalocyanine (Pc)-functionalized graphene chemiresistors supported by the theoretical prediction of Pc's VOC interactions. Pc functionalization, with and without metalation, was studied parametrically with varying deposition parameters to explore impacts on the gas sensing response toward VOCs as a function of substrate coverage. Sensing data were collected to establish fingerprint signatures for a variety of VOCs. In conclusion, improvement in selectivity is shown by successfully differentiating the VOCs from each other when combined into a gas sensor array tested with acetone, ethanol, formaldehyde, and toluene.

2D materials↗

Comparison of Power System Current Sensors via Playback of Electrical Disturbances

The need to accurately measure high-frequency content in power system voltage and current phenomena is increasingly becoming more of a priority. As the amount of distributed energy resources (DER) and nonlinear loads penetrating the grid increases, so do challenges associated with traditional measurement and metering applications. In this paper, three commercially-available medium-voltage-level current sensors are characterized in terms of their harmonic amplitude and phase performance against reference signals that are “played back” through the sensors through the use of an arbitrary waveform generator. It is shown that none of the three sensors studied are able to faithfully replicate all of the input signals completely, though there are advantages and disadvantages to each in terms of noise, resonance, and induced phase drift. Additionally, the Goodness-of-Fit metric, typically used for PMU model validation, is used to generate side-by-side comparisons of sensor accuracy over a small window around the events under study.

Wilson, Aaron↗

Lab-on-a-Fish Monitoring Software V1.0

This is the original monitoring software for processing and displaying data for Lab-on-a-Fish. Lab-on-a-Fish simultaneously evaluates and monitors the health, behavior, and environment of fish or small aquatic species. The sensor is a miniaturized underwater monitoring system that measures animal behavior (acceleration and gyration); physiology (electrocardiogram and electromyogram); and environmental parameters (temperature, pressure, and magnetic sensor).

Deng, Daniel↗

DigiFloat (Final Scientific/Technical Report)

This purpose of this report is to document the development of a floating offshore wind platform Digital Twin for the ARPA-E-funded DigiFloat project led by Principle Power, Inc. In Offshore Wind, Digital Twins are aimed at reducing farm-wide OPEX expenditures through reduced-basis inspection, assessing life extension methods, and obtaining better knowledge of the deployed assets for future product optimization. There is a high level of technical effectiveness and economic feasibility for the technology investigated, as it uses commercial off-the-shelf sensors, and a commercial software package. A substantial portion of the project goals are improvement of existing technology for use with floating wind turbines, and new application of an existing technology to a rapidly-growing sector. A few sensors applied to a small number of units bring benefit to the entire fleet of floating wind turbines in a given farm, and in other future wind farms. The benefits to the public of this project are further optimization and maturation of floating wind technology, to bring it to the U.S. market faster and cheaper.

17 WIND ENERGY↗

Low-Environmental-Impact Monitoring of CO 2 Using Seismic Methods in North Dakota

Conference poster presented at American Association of Petroleum Geologists (AAPG) Carbon Capture, Utilization, and Storage (CCUS) Conference, Houston, Texas, March 28–30, 2022. In 2021, the Energy & Environmental Research Center initiated a multiyear research project associated with Red Trail Energy’s Carbon Capture and Storage Project. The research is based on the scalable automated sparse seismic array (SASSA), a lower-cost, less invasive seismic method that could replace the large-scale 3D seismic surveys by using four stationary seismic sources called surface orbital vibrators (SOVs) and a small number of seismic sensors deployed sparsely within the same 8-square-mile area investigated with a 3D seismic survey conducted in 2019.

01 COAL, LIGNITE, AND PEAT↗

Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors

For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region, to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must exploit the large signal derivative and small noise provided by the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2×2 LGAD array of 1.1×1.1 mm 2 pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect, which arises from the different preamplifier response for various injected charges, can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Utility of Satellites and Autonomous Remote Sensing Platforms for Monitoring Offshore Aquaculture Farms: A Case Study for Canopy Forming Kelps

The emerging sector of offshore kelp aquaculture represents an opportunity to produce biofuel feedstock to help meet growing energy demand. Giant kelp represents an attractive aquaculture crop due to its rapid growth and production, however precision farming over large scales is required to make this crop economically viable. These demands necessitate high frequency monitoring to ensure outplant success, maximum production, and optimum quality of harvested biomass, while the long distance from shore and large necessary scales of production makes in person monitoring impractical. Remote sensing offers a practical monitoring solution and nascent imaging technologies could be leveraged to provide daily products of the kelp canopy and subsurface structures over unprecedented spatial scales. Here, we evaluate the efficacy of remote sensing from satellites and aerial and underwater autonomous vehicles as potential monitoring platforms for offshore kelp aquaculture farms. Decadal-scale analyses of the Southern California Bight showed that high offshore summertime cloud cover restricts the ability of satellite sensors to provide high frequency direct monitoring of these farms. By contrast, daily monitoring of offshore farms using sensors mounted to aerial and underwater drones seems promising. Small Unoccupied Aircraft Systems (sUAS) carrying lightweight optical sensors can provide estimates of canopy area, density, and tissue nitrogen content on the time and space scales necessary for observing changes in this highly dynamic species. Underwater color imagery can be rapidly classified using deep learning models to identify kelp outplants on a longline farm and high acoustic returns of kelp pneumatocysts from side scan sonar imagery signal an ability to monitor the subsurface development of kelp fronds. Current sensing technologies can be used to develop additional machine learning and spectral algorithms to monitor outplant health and canopy macromolecular content, however future developments in vehicle and infrastructure technologies are necessary to reduce costs and transcend operational limitations for continuous deployment in an offshore setting.

54 ENVIRONMENTAL SCIENCES↗