Search NASA⌕ Search

SEARCH · Search NASA

Results for “smart meter data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Guest Editorial: Advanced Data-Analytics for Power System Operation, Control, and Enhanced Situational Awareness

Along with the smart grid development, modern power systems are entering a ‘data-intensive’ era. A vast volume of data from power grids is being collected through advanced sensing and communication technologies, such as smart metering data, phasor measurement data, as well as meteorological data (e.g., wind speed and solar irradiance) related to renewable power generation. Such data contains comprehensive information about the power system covering equipment's health status, power grid's static and dynamic characteristics, renewable power generation, customers’ electricity usage pattern, etc. Therefore, advanced data-analytics techniques are needed to convert such data to knowledge for practical applications. In line with the trend of widespread data-driven applications in power systems, this Special Issue aims to present state-of-the-art research works on advanced data-analytics for power system's operation, control, and situational awareness. There are in total twenty-six papers accepted for publication in this Special Issue through careful peer reviews and revisions. Under the overarching theme of data-driven applications in power systems, the selected papers are broadly categorised into five topics. The summary of every topic is given below. You are, however, strongly encouraged to read the full paper if interested.

Xu, Yan↗

A Game-Theoretic Data-Driven Approach for Pseudo-Measurement Generation in Distribution System State Estimation

In this paper, we present an efficient computational framework with the purpose of generating weighted pseudo-measurements to improve the quality of distribution system state estimation (DSSE) and provide observability with advanced metering infrastructure (AMI) against unobservable customers and missing data. The proposed technique is based on a game-theoretic expansion of relevance vector machines (RVMs). This platform is able to estimate the nodal power consumption and quantify its uncertainty while reducing the prohibitive computational burden of model training for large AMI datasets. To achieve this objective, the large training set is decomposed and distributed among multiple parallel learning entities. The resulting estimations from the parallel RVMs are then combined using a game-theoretic model based on the idea of repeated games with vector payoff. It is observed that through this approach and by exploiting the seasonal changes in customers’ behavior the accuracy of pseudo-measurements can be considerably improved, while introducing robustness against bad training data samples. The proposed pseudo-measurement generation model is integrated into a DSSE using a closed-loop information system, which takes advantage of a branch current state estimator (BCSE) to further improve the performance of the designed machine learning framework. This method has been tested on a practical distribution feeder model with smart meter data for verification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Consumer safety-oriented scheduling of rotating power outages during heat waves

Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.

Building thermal simulation↗

Characterizing patterns and variability of building electric load profiles in time and frequency domains

The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. Furthermore, the commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The bill alignment test: Identifying trade-offs with residential rate design options

The proliferation of smart meter data allows the application of new analytic methods to inform regulatory deliberations. The bill alignment test (BAT) method, which compares the costs allocated to each residential customer with their electric bill, is introduced to help regulators consider how a proposed rate design balances various regulatory criteria. The BAT requires an explicit statement of preferences by policymakers or stakeholders and choices about allocating residual costs unassociated with customer-level causality. The BAT is applied to more than 35,000 smart-meter customer load profiles to assess the trade-offs associated with proposed rate designs. Here this example demonstrates the impact of residual cost allocation preferences and tariff design choices on proposed tariff evaluation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gaining Real-Time Water Leak Detection

Devens Reserve Forces Training Area is a United States Army Reserve (USAR) Installation that struggles with severe water leaks, often causing significant damage to the facility and requiring major renovation. Traditional water use is highly dependent on occupancy, so it can be difficult to benchmark a facility’s water use. It can be exceptionally difficult when occupancy is transient and/or varies. Pacific Northwest National Laboratory (PNNL) collaborated with Devens to implement real-time monitoring of their water consumption by utilizing the smart meter data from their existing 23 water meters. PNNL created a simple algorithm to calculate hourly water consumption and trigger an alert to be instantly emailed to Devens’ personnel when there appears to be a water leak in any building with a smart water meter. Here, this approach is expected to save hundreds of thousands of dollars in unnecessary water consumption costs and damages from leaks and was implemented with little-to-no costs or service disruptions. Next steps for this project include slow leak detection through nighttime monitoring and to extrapolate this water leak approach to the remainder 360 water meters on USAR’s Enterprise Building Control System so USAR sites across the country can be instantly notified of potential water leaks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quality Control Methods for Advanced Metering Infrastructure Data

While urban-scale building energy modeling is becoming increasingly common, it currently lacks standards, guidelines, or empirical validation against measured data. Empirical validation necessary to enable best practices is becoming increasingly tractable. The growing prevalence of advanced metering infrastructure has led to significant data regarding the energy consumption within individual buildings, but is something utilities and countries are still struggling to analyze and use wisely. In partnership with the Electric Power Board of Chattanooga, Tennessee, a crude OpenStudio/EnergyPlus model of over 178,000 buildings has been created and used to compare simulated energy against actual, 15-min, whole-building electrical consumption of each building. In this study, classifying building type is treated as a use case for quantifying performance associated with smart meter data. This article attempts to provide guidance for working with advanced metering infrastructure for buildings related to: quality control, pathological data classifications, statistical metrics on performance, a methodology for classifying building types, and assess accuracy. Advanced metering infrastructure was used to collect whole-building electricity consumption for 178,333 buildings, define equations for common data issues (missing values, zeros, and spiking), propose a new method for assigning building type, and empirically validate gaps between real buildings and existing prototypes using industry-standard accuracy metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated pipeline framework for processing of large-scale building energy time series data

Commercial buildings account for one third of the total electricity consumption in the United States and a significant amount of this energy is wasted. Therefore, there is a need for “virtual” energy audits, to identify energy inefficiencies and their associated savings opportunities using methods that can be non-intrusive and automated for application to large populations of buildings. Here we demonstrate virtual energy audits applied to large populations of buildings’ time-series smart-meter data using a systematic approach and a fully automated Building Energy Analytics (BEA) Pipeline that unifies, cleans, stores and analyzes building energy datasets in a non-relational data warehouse for efficient insights and results. This BEA pipeline is based on a custom compute job scheduler for a high performance computing cluster to enable parallel processing of Slurm jobs. Within the analytics pipeline, we introduced a data qualification tool that enhances data quality by fixing common errors, while also detecting abnormalities in a building’s daily operation using hierarchical clustering. We analyze the HVAC scheduling of a population of 816 buildings, using this analytics pipeline, as part of a cross-sectional study. With our approach, this sample of 816 buildings is improved in data quality and is efficiently analyzed in 34 minutes, which is 85 times faster than the time taken by a sequential processing. The analytical results for the HVAC operational hours of these buildings show that among 10 building use types, food sales buildings with 17.75 hours of daily HVAC cooling operation are decent targets for HVAC savings. Overall, this analytics pipeline enables the identification of statistically significant results from population based studies of large numbers of building energy time-series datasets with robust results. These types of BEA studies can explore numerous factors impacting building energy efficiency and virtual building energy audits. This approach enables a new generation of data-driven buildings energy analysis at scale.

36 MATERIALS SCIENCE↗

A Data-Driven Global Sensitivity Analysis Framework for Three-Phase Distribution System with PVs

Global sensitivity analysis (GSA) of distribution systems with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution systems. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of PV and load power injections. The sampling-based method approximates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-node distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.

14 SOLAR ENERGY↗

Insights from Smart Meters: Identifying Specific Actions, Behaviors, and Characteristics That Drive Savings in Behavior-Based Programs

In this report, we use smart meter data to analyze specific actions, behaviors, and characteristics that drive energy savings in a BB program. Specifically, we examine a Home Energy Report (HER) program. These programs typically obtain 1% to 3% annual savings, and recent studies have shown hourly savings of between 0.5% and 3%.1 But what is driving these savings? What types of households tend to be “high-savers,” and what behaviors are they adopting? There are several possibilities: one-time behaviors (e.g., changing thermostat settings), reoccurring habitual behaviors (e.g., turning off lights), and equipment purchase behaviors (e.g., energy efficient appliances); these may vary across households, regions, and over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Beyond Energy Efficiency: A clustering approach to embed demand flexibility into building energy benchmarking

The intermittency of carbon-free renewables and the demand changes associated with the widespread push for electrifying the transportation and building sectors provides an opportunity for buildings to go beyond energy efficiency and push towards providing demand flexibility to the electricity grid. The duality of energy efficiency and demand flexibility is necessary for success in a sustainable and reliable energy transition. Current building energy benchmarking models are limited in their ability to integrate concepts of demand flexibility and/or utilize granular smart meter data. Thus, current benchmarking methods are focused annual energy usage and fail to incorporate how the time of use of energy consumption impacts emissions in a quickly changing energy grid. Without a more comprehensive view of energy usage and associated real-time emissions, current benchmarking methods are unlikely to realize the full decarbonization potential of buildings. New emerging data streams provide an opportunity to develop a new generation of benchmarking energy models that embed dimensions of energy efficiency, grid interactivity, and demand flexibility into their analysis. In this paper, we propose a four-step method for embedding grid interactivity and demand flexibility into building benchmarking models that utilizes emerging building and time-series electricity data streams. We first engineer features to produce a mix-type dataset that encompasses many attributes of grid-interactive and efficient buildings, and then we apply K-medoids using Gower's Distance to produce peer-group clusters. We apply the method to a case study of 306 primary and secondary schools in southern California, USA. The results show that the method effectively clusters buildings by attributes of demand flexibility and energy efficiency. The clustering results reveal patterns in inefficient building operations and demand inflexibility at the building peer group level. In conclusion, the interpretation of clusters can serve as an integrated energy efficiency and demand flexibility benchmarking model and inform performance-specific policy targeting for buildings that go beyond traditional efficiency measures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Association rule mining based quantitative analysis approach of household characteristics impacts on residential electricity consumption patterns

The comprehensive understanding of the residential electricity consumption patterns (ECPs) and how they relate to household characteristics can contribute to energy efficiency improvement and electricity consumption reduction in the residential sector. After recognizing the limitations of current studies (i.e. unreasonable typical ECP (TECP) extraction method and the problem of multicollinearity and interpretability for regression and machine learning models), this paper proposes an association rule mining based quantitative analysis approach of household characteristics impact on residential ECPs trying to address them together. First, an adaptive density-based spatial clustering of applications with noise (DBSCAN) algorithm is utilized to create seasonal TECP of each individual customer only for weekdays. K-means is then adopted to group all the TECPs into several clusters. An enhanced Apriori algorithm is proposed to reveal the relationships between TECPs and thirty five factors covering four categories of household characteristics including dwelling characteristics, socio-demographic, appliances and heating and attitudes towards energy. Results of the case study using 3326 records containing smart metering data and survey information in Ireland suggest that socio-demographic and cooking related factors such as employment status, occupants and whether cook by electricity have strong significant associations with TECPs, while attitudes related factors almost have no effect on TECPs. The results also indicate that those households with more than one person are more likely to change ECP across seasons. The proposed approach and the findings of this study can help to support decisions about how to reduce electricity consumption and CO2 emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancement of Distribution System State Estimation Using Pruned Physics-Aware Neural Networks

Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classic state estimation algorithms. In this paper, a new method, called the pruned physics-aware neural network (P2N2), is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one- year smart meter data of load consumptions for three-phase power flow is developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS in terms of data redundancy and estimation accuracy.

distribution system state estimation↗

Mobilizing the anti-duck brigade: technology and market pathways for load-shifting demand response in California

With rapidly increasing renewable power generation, the California electricity system is experiencing the impacts of the so-called “duck curve,” with occasional over-generation in the middle of the day, followed by rapid ramping of net demand producing a sharp evening peak. Mitigating this pattern will require novel demand-side management approaches to shifting demand away from high net demand periods and toward high renewables generation periods. In this paper, drawing from more than 200,000 individual residential, commercial, and industrial customers’ hourly smart meter data, we disaggregate load shapes for certain key end-uses and then average the results across a highly granular set of customer segments by sector, building type, demand profile and geographic region, to yield a library of characteristic daily load profiles (“clusters”) for different end-uses and seasons. By categorizing the library into particularly desirable or undesirable load shapes in the context of mitigating the duck curve, we can gain insight into specific technologies, seasonal effects, or site-level attributes that may serve as helpful levers to use in developing future load-shifting programs. Based on these insights, we develop recommendations on technologies and new market structures and incentives that can create a future demand curve that more closely matches renewable generation patterns.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insights from Smart Meters. Identifying Specific Actions, Behaviors and Characteristics that drive savings in Behavior-Based Programs

In this report, we use smart meter data to analyze specific actions, behaviors, and characteristics that drive energy savings in a behavior-based (BB) program. Specifically, we examine a Home Energy Report (HER) program. These programs typically obtain 1% to 3% annual savings, and recent studies have shown hourly savings of between 0.5% and 3%. But what is driving these savings? What types of households tend to be “high-savers”, and what behaviors are they adopting? There are several possibilities: one-time behaviors (e.g., changing thermostat settings); reoccurring habitual behaviors (e.g., turning off lights); and equipment purchase behaviors (e.g., energy efficient appliances), and these may vary across households, regions, and over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential bill impacts of dynamic electricity pricing on California utility customers

The rapid growth of renewable generation is creating challenges for the California grid in the form of the “duck curve,” with increasingly steep ramping required for conventional generation resources in the morning and evening, and growing curtailment of solar resources in midday periods. Time-varying electricity tariffs have received considerable attention as a tool to address these challenges, with a renewed recent focus on the potential for dynamic tariffs that vary to reflect conditions on the grid in near-real time. Consideration of dynamic tariffs may raise concerns about the financial impact on utility customers, especially for those who have limited flexibility to modify their electricity consumption in response. Specific areas of concern include electricity bills, bill volatility, and equity implications related to cost shifting among customer groups. In this paper we leverage smart meter data for more than 400,000 California utility customers, spanning residential, commercial, industrial, and agricultural customers, to assess potential customer bill impacts arising from a multi-component dynamic tariff . Specifically, we compute impacts on customer bills and bill volatility under the assumption of fully inelastic demand, i.e., where customers do not change their consumption patterns in response to the tariff. We also assess various approaches designing subscription load shapes that customers can pre-purchase as a hedge that may provide a measure of protection against large negative impacts, while still incentivizing the modification of loads on the margin. We compare and contrast the relative impacts on different customer classes and discuss benefits and pitfalls of different dynamic tariff structures and subscription load shapes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancement of Distribution System State Estimation Using Pruned Physics-Aware Neural Networks: Preprint

Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classical state estimation algorithms. In this paper, a new method so-called pruned physics-aware neural network (P2N2) is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one-year smart meter data of load consumptions for threephase power flow is developed to generate the measurement and voltage state data. The IEEE 123 node system is selected as the test network to benchmark the proposed algorithm against the classical weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS, in terms of data redundancy and estimation accuracy.

distribution systems state estimation↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗