Search NASA⌕ Search

SEARCH · Search NASA

Results for “soft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

BMS symmetry, soft particles and memory

Here, in this work, we revisit unitary irreducible representations of the Bondi–Metzner–Sachs (BMS) group discovered by McCarthy. Representations are labelled by an infinite number of supermomenta in addition to 4-momentum. Tensor products of these irreducible representations lead to particle-like states dressed by soft gravitational modes. Conservation of 4-momentum and supermomentum in the scattering of such states leads to a memory effect encoded in the outgoing soft modes. We note there exist irreducible representations corresponding to soft states with strictly vanishing 4-momentum, which may nevertheless be produced by scattering of particle-like states. This fact has interesting implications for the S-matrix in gravitational theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Soft crystal martensites: An in situ resonant soft x-ray scattering study of a liquid crystal martensitic transformation

Liquid crystal blue phases (BPs) are three-dimensional soft crystals with unit cell sizes orders of magnitude larger than those of classic, atomic crystals. The directed self-assembly of BPs on chemically patterned surfaces uniquely enables detailed in situ resonant soft x-ray scattering measurements of martensitic phase transformations in these systems. The formation of twin lamellae is explicitly identified during the BPII-to-BPI transformation, further corroborating the martensitic nature of this transformation and broadening the analogy between soft and atomic crystal diffusionless phase transformations to include their strain-release mechanisms.

36 MATERIALS SCIENCE↗

Observation of coupled vortex gyrations by 70-ps-time- and 20-nm-space-resolved full-field magnetic transmission soft x-ray microscopy

We employed time- and space-resolved full-field magnetic transmission soft x-ray microscopy to observe vortex-core gyrations in a pair of dipolar-coupled vortex-state Permalloy (Ni{sub 80}Fe{sub 20}) disks. The 70 ps temporal and 20 nm spatial resolution of the microscope enabled us to simultaneously measure vortex gyrations in both disks and to resolve the phases and amplitudes of both vortex-core positions. We observed their correlation for a specific vortex-state configuration. This work provides a robust and direct method of studying vortex gyrations in dipolar-coupled vortex oscillators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of laser generated soft X-ray emission from irradiated gold foils

Soft x-ray emission from laser irradiated gold foils was measured at the Omega-60 laser system using the Dante photodiode array. The foils were heated with 2 kJ, 6 ns laser pulses and foil thicknesses were varied between 0.5, 1.0, and 2.0 μm. Initial Dante analysis indicates peak emission temperatures of roughly 100 eV and 80 eV for the 0.5 μm and 1.0 μm thick foils, respectively, with little measurable emission from the 2.0 μm foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic structure of cobalt doped CdSe quantum dots using soft X-ray spectroscopy

Here, the electronic structure and magnetic properties of cobalt doped CdSe quantum dots (QDs) are studied using electron microscopy, soft X-ray spectroscopy, and magnetometry. Magnetometry measurements suggest these QDs are superparamagnetic, contrary to a spin-glass state observed in the bulk analogue. Electron microscopy shows well formed QDs, but with cobalt existing as doped into the QD and as unreacted species not contained in the QD. X-ray absorption measurements at the Co L3-edge suggest that changes in spectra features as a function of particle size can be described considering combination of a cobalt ion in a tetrahedral crystal field and an octahedrally coordinated (impurity) phase. With decreasing particle sizes, the impurity phase increases, suggesting that small QDs can be difficult to dope.

36 MATERIALS SCIENCE↗

Calibration of a high resolution grating soft x-ray spectrometer

The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 A waveband at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) x-ray source with the EBIT calorimeter spectrometer. The HRGS instrument is designed for laser-produced plasma experiments and is important for making high dynamic range measurements of line intensities, line shapes, and x-ray sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved soft x-ray spectra from laser-produced Cu plasma

The volumetric heating of a thin copper target has been studied with time resolved x-ray spectroscopy. The copper target was heated by a plasma produced using the Lawrence Livermore National Laboratory's Compact Multipulse Terawatt (COMET) laser. A variable spaced grating spectrometer coupled to an x-ray streak camera measured soft x-ray emission (800-1550 eV) from the back of the copper target to characterize the bulk heating of the target. Radiation hydrodynamic simulations were modeled in two-dimensions using the HYDRA code. The target conditions calculated by HYDRA were post-processed with the atomic kinetics code CRETIN to generate synthetic emission spectra. A comparison between the experimental and simulated spectra indicates the presence of specific ionization states of copper and the corresponding electron temperatures and ion densities throughout the laser-heated copper target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas cell for in situ soft X-ray transmission-absorption spectroscopy of materials

A simple gas cell design, constructed primarily from commercially available components, enables in situ soft X-ray transmission-absorption spectroscopy of materials in contact with gas at ambient temperature. The cell has a minimum X-ray path length of 1 mm and can hold gas pressures up to ~300 Torr, and could support higher pressures with simple modifications. The design enables cycling between vacuum and gas environments without interrupting the X-ray beam, and can be fully sealed to allow for measurements of air-sensitive samples. The cell can attach to the downstream port of any appropriate synchrotron beamline, and offers a robust and versatile method for in situ measurements of certain materials. The construction and operation of the cell are discussed, as well as sample preparation and proper spectral analysis, illustrated by examples of spectral measurements. Potential areas for improvement and modification for specialized applications are also mentioned.

47 OTHER INSTRUMENTATION↗

Plasma response measurements of non-axisymmetric magnetic perturbations on DIII-D via soft x-ray imaging

Recent observations on DIII-D have advanced the understanding of plasma response to applied resonant magnetic perturbations (RMPs) in both H-mode and L-mode plasmas. Three distinct 3D features localized in minor radius are imaged via filtered soft x-ray emission: (i) the formation of lobes extending from the unperturbed separatrix in the X-point region at the plasma boundary, (ii) helical kink-like perturbations in the steep-gradient region inside the separatrix, and (iii) amplified islands in the core of a low-rotation L-mode plasma. In this study, these measurements are used to test and to validate plasma response models, which are crucial for providing predictive capability of edge-localized mode control. In particular, vacuum and two-fluid resistive magnetohydrodynamic(MHD) responses are tested in the regions of these measurements. At the plasma boundary in H-mode discharges with n = 3 RMPs applied, measurements compare well to vacuum-field calculations that predict lobe structures. Yet in the steep-gradient region, measurements agree better with calculations from the linear resistive two-fluid MHD code, M3D-C1. Relative to the vacuum fields, the resistive two-fluid MHD calculations show a reduction in the pitch-resonant components of the normal magnetic field (screening), and amplification of non-resonant components associated with ideal kink modes. However, the calculations still over-predict the amplitude of the measuredperturbation by a factor of 4. In a slowly rotating L-mode plasma with n = 1 RMPs, core islands are observed amplified from vacuum predictions. Finally, these results indicate that while the vacuum approach describes measurements in the edge region well, it is important to include effects of extended MHD in the pedestal and deeper in the plasma core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DRILL Interface Makes Ion Soft Landing Broadly Accessible for Energy Science and Applications

Polyoxometalates (POM) have been deposited onto carbon nanotube (CNT) electrodes using benchtop ion soft landing (SL) enabled by a vortex-confined electrohydrodynamic desolvation process. The device is based on the dry ion localization and locomotion (DRILL) mass spectrometry interface of Fedorov and co-workers. By adding electrospray emitters, heating the desolvation gas, and operating at high gas flow rates, it is possible to obtain stable ion currents up to -15 nA that are ideal for deposition. Coupled with ambient ion optics, this interface enables desolvated ions to be delivered to surfaces while excluding solvent and counterions. Electron microscopy of surfaces prepared using the device reveal discrete POM and no aggregation that degrades electrode performance. Characterization of POM-coated CNT electrodes in a supercapacitor showed an energy storage capacity similar to that achieved with SL in vacuum. For solutions that produce primarily a single ion by electrospray ionization, benchtop SL offers a simpler and less costly approach for surface modification with applications in catalysis, energy storage, and beyond.

Johnson, Grant E.↗

Histologic Appearance After Preoperative Radiation Therapy for Soft Tissue Sarcoma: Assessment of the European Organization for Research and Treatment of Cancer–Soft Tissue and Bone Sarcoma Group Response Score

Purpose: To critically assess the prognostic value of the European Organization for Research and Treatment of Cancer–Soft Tissue and Bone Sarcoma Group (EORTC-STBSG) response score and define histologic appearance after preoperative radiation therapy (RT) for soft tissue sarcoma (STS). Methods and Materials: For a cohort of 100 patients with STS of the extremity/trunk treated at our institution with preoperative RT followed by resection, 2 expert sarcoma pathologists evaluated the resected specimens for percent residual viable cells, necrosis, hyalinization/fibrosis, and infarction. The EORTC response score and other predictors of recurrence-free survival (RFS) and overall survival (OS) were assessed by Kaplan-Meier and proportional hazard models. Results: Median tumor size was 7.5 cm; 92% were intermediate or high grade. Most common histologies were unclassified sarcoma (34%) and myxofibrosarcoma (25%). Median follow-up was 60 months. The 5-year local recurrence rate was 5%, 5-year RFS was 68%, and 5-year OS was 75%. Distribution of cases according to EORTC response score tiers was as follows: no residual viable tumor for 9 cases (9% pathologic complete response); <1% viable tumor for 0, ≥1% to <10% for 9, ≥10% to <50% for 44, and ≥50% for 38. There was no association between EORTC-STBSG response score and RFS or OS. Conversely, hyalinization/fibrosis was a significant independent favorable predictor for RFS (hazard ratio 0.49, P=.007) and OS (hazard ratio 0.36, P=.02). Conclusion: Histologic evaluation after preoperative RT for STS showed a 9% pathologic complete response rate. The EORTC-STBSG response score and percent viable cells were not prognostic. Hyalinization/fibrosis was associated with favorable outcome, and if validated, may become a valid endpoint for neoadjuvant trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Soft matter from liquid crystals

We review advances in soft matter research based on liquid crystals, including recent studies of liquid crystals beyond equilibrium.

Kim, Young-Ki↗

Strain induced vortex-to-uniform polarization transitions in soft-ferroelectric nanoparticles

Domain structures of ferroelectric polarization in patterned nanostructures depend sensitively on an interplay between their geometry and crystallographic anisotropy. In the recently predicted layered perovskite PbSr2Ti2O7 [S. M. Nakhmanson and I. Naumov, Phys. Rev. Lett. 104, 097601 (2010)], the in-plane anisotropy can be controlled by strain to be along in-plane [110]-directions or to vanish, in which case the polarization is free to rotate in the perovskite-layer. Using a microscopic Landau-Ginzburg-Devonshire free energy functional theory, we demonstrate that the domain structure in patterned disks of PbSr2Ti2O7 can be varied between uniform polarization and a vortex structure, analogous to vortices in soft magnetic disks. This opens up the possibility of designing nanostructured layered materials whose dielectric response can be manipulated with small elastic distortions.

Lee, Byounghak↗

Complete recovery of actinides from UREX-like raffinates using a combination of hard and soft donor ligands. II. soft donor structure variation

The feasibility of simultaneous separation of uranium, neptunium, plutonium, americium, and curium from a simulated dissolved used fuel simulant adjusted to 1.0 M nitric acid is investigated using a mixture of the soft donor bis(bis-3,5-trifluoromethyl)phenyl) dithiophosphinic acid (“0”) and the hard donor synergist trioctylphosphine oxide (TOPO) dissolved in toluene. The results reported in this work are compared to our recent demonstration of a complete actinide recovery from a simulated dissolved fuel solution using a synergistic combination of bis(o-trifluoromethylphenyl)dithiophosphinic acid (“1”) and TOPO dissolved in either toluene or trifluoromethylphenyl sulfone. While the extraction efficiency of americium was enhanced for the liquid-liquid system containing “0”, enabling to accomplish a trivalent An/Ln separation at 1.0 M HNO3, the extraction of neptunium was drastically diminished, relative to “1”. The partitioning behavior of curium was also negatively impacted, introducing an effective opportunity for americium/curium separation. Radiometric and spectrophotometric studies demonstrate that the complete actinide recovery using the solvent based upon “0” and TOPO is not feasible. Additionally, the importance of radiolytic degradation processes is discussed through the comparisons of extraction properties of liquid-liquid systems based on both soft donor reagents.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗