Search NASA⌕ Search

SEARCH · Search NASA

Results for “soft errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Poster - 48: Clinical assessment of ExacTrac stereoscopic imaging of spine alignment for lung SBRT

Purpose: To evaluate the validity of using spine as a surrogate for tumor positioning with ExacTrac stereoscopic imaging in lung stereotactic body radiation therapy (SBRT). Methods: Using the Novalis ExacTrac x-ray system, 39 lung SBRT patients (182 treatments) were aligned before treatment with 6 degrees (6D) of freedom couch (3 translations, 3 rotations) based on spine matching on stereoscopic images. The couch was shifted to treatment isocenter and pre-treatment CBCT was performed based on a soft tissue match around tumor volume. The CBCT data were used to measure residual errors following ExacTrac alignment. The thresholds for re-aligning the patients based on CBCT were 3mm shift or 3° rotation (in any 6D). In order to evaluate the effect of tumor location on residual errors, correlations between tumor distance from spine and individual residual errors were calculated. Results: Residual errors were up to 0.5±2.4mm. Using 3mm/3° thresholds, 80/182 (44%) of the treatments required re-alignment based on CBCT soft tissue matching following ExacTrac spine alignment. Most mismatches were in sup-inf, ant-post, and roll directions which had larger standard deviations. No correlation was found between tumor distance from spine and individual residual errors. Conclusion: ExacTrac stereoscopic imaging offers a quick pre-treatment patient alignment. However, bone matching based on spine is not reliable for aligning lung SBRT patients who require soft tissue image registration from CBCT. Spine can be a poor surrogate for lung SBRT patient alignment even for proximal tumor volumes.

60 APPLIED LIFE SCIENCES↗

Relationship between the contact force strength and numerical inaccuracies in piecewise-smooth systems

This work studies the different types of behavior and inaccuracies that can occur when contact is not adequately accounted for in a dynamical system with freeplay, as the strength of the contact stiffness increases. The MATLAB® ode45 time integration solver, with the built-in Event Location capability, is first validated using past experimental data from a forced Duffing oscillator with freeplay. Next, numerical results utilizing event location are compared to results neglecting event location in order to highlight possible numerical errors and effects on multistable dynamical responses. Inaccuracies tend to occur in two different ways. First, neglecting event location can affect the boundaries between basins of attraction. Second, neglecting event location has little effect on the behaviors of the attractor solutions themselves besides merely resembling poorly converged solutions. Errors are less pronounced at the limits of soft or hard contact stiffness. Finally, this study shows the importance of accurately solving piecewise-smooth systems and the existing correlation between the strength of the contact force and possible numerical inaccuracies.

42 ENGINEERING↗

A review of setup error in supine breast radiotherapy using cone-beam computed tomography

Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design, Analyses and Validation of Sliding Mode Control for a DAB DC-DC Converter

In this paper, a comprehensive voltage control loop design for a dual active bridge (DAB)DC-DC converter is proposed using the sliding mode control (SMC), where the coefficients are formed to ensure both small signal and large signal stability of the system. The major objectives of the proposed SMC are to enhance the converter dynamics and attain a tight output voltage regulation under fast load fluctuations or during start-up. In addition, dynamic performance of the system is examined considering the steady state error and overshoot. The proposed control method is capable of achieving soft-switching operation by determining the effective duty phase displacement range. To verify the proposed method, a hardware prototype of a DAB converter is developed and evaluated, and the effectiveness of the loop design is validated by the experiment. It is observed that overshoot is eliminated in the start-up test and the fast settling time is achieved.

Zou, Shenli↗

A Fast-Response High-Accuracy Overvoltage Protection Circuit for Soft-Switching Current-Source Converters

Although voltage-source converters (VSCs) have been a focus of research for decades and are widely applied in numerous applications, they face great challenges in short-circuit failures, high dv/dt and electromagnetic interference (EMI), especially using wide bandgap devices. Instead, current-source converters (CSCs) are attracting increasing attention in recent years owing to their friendliness to short-circuit faults, improved EMI, etc. For CSCs, overvoltage is the most catastrophic failure since the semiconductor devices can hardly withstand an overvoltage for a short pulse. In this paper, a fast-response high-accuracy overvoltage protection (OVP) circuit is proposed to protect CSCs from overvoltage damage. It also features a small form factor, good noise-immunity, friendly retrofit capability, and no need for active switches. In this paper, the operating principle and design guideline of the proposed OVP circuit is introduced. Its effectiveness is validated in soft-switching solid-state transformer (S4T) at 500 V. In experiments, the voltage detection error of less than 5% and a propagation delay of fewer than 400 ns have been achieved.

30 DIRECT ENERGY CONVERSION↗

Kinematics of current region fragmentation in semi-inclusive deeply inelastic scattering

Different kinematical regions of semi-inclusive deeply inelastic scattering (SIDIS) processes correspond to different underlying partonic pictures, and it is important to understand the transition between them. We find criteria in semi-inclusive deeply inelastic scattering (SIDIS) for identifying the current fragmentation region — the kinematical region where a factorization picture with fragmentation functions is appropriate, especially for studies of transverse-momentum-dependent (TMD) functions. This region is distinguished from the central (soft) and target fragmentation regions. The basis of our argument is in the errors in approximations used in deriving factorization. As compared with previous work, we show that it is essential to take account of the transverse momentum of the detected hadron, and we find a much more restricted range for genuine current fragmentation. We show that it is important to develop an extended factorization formulation to treat hadronization in the central region, as well as the current and target fragmentation regions, and to obtain a unified formalism spanning all rapidities for the detected hadron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge Radius of Neutron-Deficient Ni 54 and Symmetry Energy Constraints Using the Difference in Mirror Pair Charge Radii

he nuclear root-mean-square charge radius of Ni 54 was determined with collinear laser spectroscopy to be R ( Ni 54 ) = 3.737 ( 3 ) fm . In conjunction with the known radius of the mirror nucleus Fe 54 , the difference of the charge radii was extracted as Δ R ch = 0.049 ( 4 ) fm . Based on the correlation between Δ R ch and the slope of the symmetry energy at nuclear saturation density ( L ), we deduced 21 ≤ L ≤ 88 MeV . The present result is consistent with the L from the binary neutron star merger GW170817, favoring a soft neutron matter EOS, and barely consistent with the PREX-2 result within 1 σ error bands. Our result indicates the neutron-skin thickness of Ca 48 as 0.15–0.21 fm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lattice QCD calculation of 𝑥-dependent meson distribution amplitudes at physical pion mass with threshold logarithm resummation

We present a lattice quantum chromodynamics (QCD) calculation of the 𝑥-dependent pion and kaon distribution amplitudes (DA) in the framework of large momentum effective theory. This calculation is performed on a fine lattice of 𝑎 = 0.076 fm at physical pion mass, with the pion boosted to 1.8 GeV and kaon boosted to 2.3 GeV. We renormalize the matrix elements in the hybrid scheme and match to Math output error with a subtraction of the leading renormalon in the Wilson-line mass. The perturbative matching is improved by resumming the large logarithms related to the small quark and gluon momenta in the soft-gluon limit. After resummation, we demonstrate that we are able to calculate a range of 𝑥 ∈[𝑥 0 ,1 − 𝑥 0 ] with 𝑥 0 = 0.25 for pion and 𝑥 0 = 0.2 for kaon with theoretical systematic errors under control. The kaon DA is shown to be slighted skewed, and narrower than pion DA. Although the 𝑥-dependence cannot be direct calculated beyond these ranges, we estimate higher moments of the pion and kaon DAs by complementing our calculation with short-distance factorization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying local and global mass balance errors in physics-informed neural networks

Physics-informed neural networks (PINN) have recently become attractive for solving partial differential equations (PDEs) that describe physics laws. By including PDE-based loss functions, physics laws such as mass balance are enforced softly in PINN. This paper investigates how mass balance constraints are satisfied when PINN is used to solve the resulting PDEs. We investigate PINN’s ability to solve the 1D saturated groundwater flow equations (diffusion equations) for homogeneous and heterogeneous media and evaluate the local and global mass balance errors. We compare the obtained PINN’s solution and associated mass balance errors against a two-point finite volume numerical method and the corresponding analytical solution. We also evaluate the accuracy of PINN in solving the 1D saturated groundwater flow equation with and without incorporating hydraulic heads as training data. We demonstrate that PINN’s local and global mass balance errors are significant compared to the finite volume approach. Tuning the PINN’s hyperparameters, such as the number of collocation points, training data, hidden layers, nodes, epochs, and learning rate, did not improve the solution accuracy or the mass balance errors compared to the finite volume solution. Mass balance errors could considerably challenge the utility of PINN in applications where ensuring compliance with physical and mathematical properties is crucial.

54 ENVIRONMENTAL SCIENCES↗

A Tale of Two Transients: GW 170104 and GRB 170105A

We present multi-wavelength follow-up campaigns by the AstroSat CZTI and GROWTH collaborations in search of an electromagnetic counterpart to the gravitational wave event GW 170104. At the time of the GW 170104 trigger, the AstroSat CZTI field of view covered 50.3% of the sky localization. We do not detect any hard X-ray (>100 keV) signal at this time, and place an upper limit of ≈4.5×10{sup −7} erg cm{sup −2} s{sup −1}, for a 1 s timescale. Separately, the ATLAS survey reported a rapidly fading optical source dubbed ATLAS17aeu in the error circle of GW 170104. Our panchromatic investigation of ATLAS17aeu shows that it is the afterglow of an unrelated long, soft GRB 170105A, with only a fortuitous spatial coincidence with GW 170104. We then discuss the properties of this transient in the context of standard long GRB afterglow models.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring the thermal conductivity of hydrogels with a bidirectional 3w method

Hydrogels are soft, water-absorbing polymer materials with diverse applications in biomedicine and agriculture. Recently, hydrogels have been proposed to encapsulate water-soluble phase change materials which store energy in their latent heat of solidification. In these applications, the thermal conductivity of these materials affects their performance. Few methods exist for measuring the thermal conductivity of small quantities of hydrogels. Here, we describe an implementation of the bidirectional 3w technique to measure the thermal conductivity of hydrogels with particular attention to their moisture content. Our implementation of the technique can probe sample volumes as little as ~20 mL and yields the thermal conductivity without requiring fitting of additional thermal parameters. We numerically simulate 3w sensor designs with frequency-domain 3-D models to quantify and reduce errors introduced by the choice of substrate and insulation layer thickness. Frequencies in the ~1−20 Hz range yield less error for the materials considered here. We verify our setup with measurements on water and report values for polyacrylamide and poly(2-acrylamido-2-methylpropane sulfonic acid) (PAMPS) hydrogels. Our swollen hydrogels exhibited thermal conductivities nearly equivalent to water, 0.6 W m-1 K-1, and we estimate thermal conductivities of 0.43 and 0.42 W m-1 K-1 for neat polyacrylamide and PAMPS, respectively. Finally, we estimate an error of ±7%, consistent with other 3ω methods, with the largest error coming from the sensor calibration. We find our implementation of the bidirectional 3w method gives reasonable results and can be employed for prototyping soft materials relevant for thermal storage.

3-omega, thermal conductivity, hydrogel, moisture ↗

Probing many-body localization on a noisy quantum computer

A disordered quantum system of interacting particles exhibits localized behavior when the disorder is large compared to the interaction strength. Studying this phenomenon on a quantum computer with no, or limited, error correction is challenging because even weak coupling to a thermal environment destroys most signatures of localization. Fortunately, spectral functions of local operators are known to contain features that can survive the presence of noise. In these spectra, discrete peaks and a soft gap at low frequencies compared to the thermal phase indicate localization. Here, we present the computation of spectral functions on a trapped-ion quantum computer for a one-dimensional Heisenberg model with disorder. Further, we design an error-mitigation technique which is effective at removing the noise from the measurement allowing clear signatures of localization to emerge as the disorder increases. Furthermore, we show that spectral functions can serve as a robust and scalable diagnostic of many-body localization on current and future generations of quantum computers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solving the Orszag–Tang vortex magnetohydrodynamics problem with physics-constrained convolutional neural networks

We study the 2D Orszag–Tang vortex magnetohydrodynamics (MHD) problem through the use of physics-constrained convolutional neural networks (PCNNs) for forecasting the density, ρ, and the magnetic field, B, as well as the prediction of B given the velocity field v of the fluid. In addition to translation equivariance from the convolutional architecture, other physics constraints were embedded: absence of magnetic monopoles, non-negativity of ρ, use of only relevant variables, and the periodic boundary conditions of the problem. The use of only relevant variables and the hard constraint of non-negative ρ were found to facilitate learning greatly. The divergenceless condition ∇·B=0 was implemented as a hard constraint up to machine precision through the use of a magnetic potential to define B=∇×A. Residual networks and data augmentation were also used to improve performance. This allowed for some of the residual models to function as surrogate models and provide reasonably accurate simulations. For the prediction task, the PCNNs were evaluated against a physics-informed neural network, which had the ideal MHD induction equation as a soft constraint. Several models were able to generate highly accurate fields, which are visually almost indistinguishable and have low mean squared error. Only methods with built-in hard constraints produced physical fields with ∇·B=0. The use of PCNNs for MHD has the potential to produce physically consistent real-time simulations to serve as virtual diagnostics in cases where inferences must be made with limited observables.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of combined function dipole-quadrupole PMQs magnets for NSLS-II upgrade

This paper focuses on the R&D performed for the development of permanent magnets-based dipoles-quadrupoles combined function magnets (PMQs) for the future NSLSII upgrade “complex bend” lattice (CB). This new lattice uses PMQs that provide both bending (dipole) and strong focusing (quadrupole) magnetic field on the electron beam. The permanent magnet (PM) technology is suitable for the high magnetic field strengths (0.5 T, 130 T/m) required for such combine function magnets. PM technology leads to a compact magnet design that is essential in realizing the complex bend lattice concept, as well as a passive magnet solution which does not require electrical power supply reducing power consumption by ~ 80% (from 1.7 MW to 0.3 MW for NSLS-II). Two PMQs magnets designs are under consideration: A hybrid design that use both PM and soft iron poles, and Halbach type that is a pure PM design. Both PMQs designs present challenges in achieving the specified magnetic field quality due to their higher sensitivity to errors (mechanical tolerances and PM properties). This paper presents cost-effective designs and prototypes results for hybrid and Halbach PMQs, addressing various technical challenges while meeting the field requirements of the complex bend lattice for the NSLS-II upgrade.

N'gotta, Patrick [Brookhaven]↗

Bayesian tomography and integrated data analysis in fusion diagnostics

In this article, a Bayesian tomography method using non-stationary Gaussian process for a prior has been introduced. The Bayesian formalism allows quantities which bear uncertainty to be expressed in the probabilistic form so that the uncertainty of a final solution can be fully resolved from the confidence interval of a posterior probability. Moreover, a consistency check of that solution can be performed by checking whether the misfits between predicted and measured data are reasonably within an assumed data error. In particular, the accuracy of reconstructions is significantly improved by using the non-stationary Gaussian process that can adapt to the varying smoothness of emission distribution. The implementation of this method to a soft X-ray diagnostics on HL-2A has been used to explore relevant physics in equilibrium and MHD instability modes. This project is carried out within a large size inference framework, aiming at an integrated analysis of heterogeneous diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gauging Metallicity of Diffuse Gas under an Uncertain Ionizing Radiation Field

Gas metallicity is a key quantity used to determine the physical conditions of gaseous clouds in a wide range of astronomical environments, including interstellar and intergalactic space. In particular, considerable effort in circumgalactic medium (CGM) studies focuses on metallicity measurements because gas metallicity serves as a critical discriminator for whether the observed heavy ions in the CGM originate in chemically enriched outflows or in more chemically pristine gas accreted from the intergalactic medium. However, because the gas is ionized, a necessary first step in determining CGM metallicity is to constrain the ionization state of the gas which, in addition to gas density, depends on the ultraviolet background radiation field (UVB). While it is generally acknowledged that both the intensity and spectral slope of the UVB are uncertain, the impact of an uncertain spectral slope has not been properly addressed in the literature. This Letter shows that adopting a different spectral slope can result in an order of magnitude difference in the inferred CGM metallicity. Specifically, a harder UVB spectrum leads to a higher estimated gas metallicity for a given set of observed ionic column densities. Therefore, such systematic uncertainties must be folded into the error budget for metallicity estimates of ionized gas. An initial study shows that empirical diagnostics are available for discriminating between hard and soft ionizing spectra. Applying these diagnostics helps reduce the systematic uncertainties in CGM metallicity estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

HSC-XXL: Baryon budget of the 136 XXL groups and clusters

Abstract We present our determination of the baryon budget for an X-ray-selected XXL sample of 136 galaxy groups and clusters spanning nearly two orders of magnitude in mass (M500 ∼ 1013–1015 M⊙) and the redshift range 0 ≲ z ≲ 1. Our joint analysis is based on the combination of Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP) weak-lensing mass measurements, XXL X-ray gas mass measurements, and HSC and Sloan Digital Sky Survey multiband photometry. We carry out a Bayesian analysis of multivariate mass-scaling relations of gas mass, galaxy stellar mass, stellar mass of brightest cluster galaxies (BCGs), and soft-band X-ray luminosity, by taking into account the intrinsic covariance between cluster properties, selection effect, weak-lensing mass calibration, and observational error covariance matrix. The mass-dependent slope of the gas mass–total mass (M500) relation is found to be $1.29_{-0.10}^{+0.16}$, which is steeper than the self-similar prediction of unity, whereas the slope of the stellar mass–total mass relation is shallower than unity; $0.85_{-0.09}^{+0.12}$. The BCG stellar mass weakly depends on cluster mass with a slope of $0.49_{-0.10}^{+0.11}$. The baryon, gas mass, and stellar mass fractions as a function of M500 agree with the results from numerical simulations and previous observations. We successfully constrain the full intrinsic covariance of the baryonic contents. The BCG stellar mass shows the larger intrinsic scatter at a given halo total mass, followed in order by stellar mass and gas mass. We find a significant positive intrinsic correlation coefficient between total (and satellite) stellar mass and BCG stellar mass and no evidence for intrinsic correlation between gas mass and stellar mass. All the baryonic components show no redshift evolution.

Akino, Daichi↗

Study on the assessment method of human error probabilities in the digitalized main control room - 170

Recently, nuclear power plants (NPPs) in Republic of Korea have been constructed with the new type of main control room (MCR) which is called as digitalized MCR. In digitalized MCR, as digital technologies are being adopted, the environment of MCR has been considerably changed. The operators may obtain the plant data via digitalized human system interfaces (HSIs), large display panel (LDP), computerized procedure system (CPS), soft controls and other system features. Accordingly, the necessity to consider the new environment of MCR has been raised when performing human reliability analysis (HRA) methods. However, none of HRA methods consider the newly installed MCRs. The goal of this paper is to propose new frameworks to assess the human error probabilities (HEPs) in digitalized MCR. Generally, the HEPs are obtained by summing the probabilities of diagnosis errors and the probabilities of execution errors and those probabilities are modified by performance shaping factors (PSFs). In this paper, two parts are included; (1) Assessing the probabilities of diagnosis errors, and (2) Assessing the probabilities of execution errors. In this paper, the process to develop the frameworks are introduced and we expect that the HEPs affecting the features of digitalized MCR can be calculated by using the proposed frameworks. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗