At least 73 records · Page 4

SiC As An Energetic Particle Detector

Several new technologies have been introduced recently in the region of semiconductor material for solid state detectors (SSD). Of particular interest is silicon carbide (SIC) since its band gap is larger than that of pure silicon, reducing its dark current and making SIC capable of operating at high temperatures and more tolerant of radiation damage. But the trade off is that a higher band gap also means fewer electron hole pairs generated, and thus a smaller signal, for detecting incident radiation. To determine what the lower limit of SiC detectors to energetic particles is, we irradiated a SiC diode with particles ranging in energy from 50 keV to 1.6 MeV and masses from 1 to 16 amu. We found that the SiC detectors sensitivity was comparable to that of pure silicon, with the SiC detector being able to measure particles down to 50 keV/amu and possibly lower.

Yan, F.↗

Development and Performance of a Suprathermal Electron Spectrometer to Study Auroral Precipitations

The design, development, and performance of Medium-energy Electron SPectrometer (MESP), dedicated to the in situ observation of suprathermal electrons in the auroral ionosphere, are summarized in this paper. MESP employs a permanent magnet filter with a light tight structure to select electrons with proper energies guided to the detectors. A combination of two avalanche photodiodes and a large area solid-state detector (SSD) provided 46 total energy bins (1 keV resolution for 3-20 keV range for APDs, and 7 keV resolution for greater than 20 keV range for SSDs). Multi-channel ultra-low power application-specific integrated circuits are also verified for the flight operation to read-out and analyze the detector signals. MESP was launched from Poker F1at Research Range on 3 March 2014 as a part of ground-to-rocket electrodynamics-electrons correlative experiment (GREECE) mission. MESP successfully measured the precipitating electrons from 3 to 120 keV in 120-ms time resolution and characterized the features of suprathermal distributions associated with auroral arcs throughout the flight. The measured electrons were showing the inverted-V type spectra, consistent with the past measurements. In addition, investigations of the suprathermal electron population indicated the existence of the energetic non-thermal distribution corresponding to the brightest aurora.

Ogasawara, Keiichi↗

Technology Needs for Gamma Ray Astronomy

Gamma ray astronomy is currently in an exciting period of multiple missions and a wealth of data. Results from INTEGRAL, Fermi, AGILE, Suzaku and Swift are making large contributions to our knowledge of high energy processes in the universe. The advances are due to new detector and imaging technologies. The steps to date have been from scintillators to solid state detectors for sensors and from light buckets to coded aperture masks and pair telescopes for imagers. A key direction for the future is toward focusing telescopes pushing into the hard X-ray regime and Compton telescopes and pair telescopes with fine spatial resolution for medium and high energy gamma rays. These technologies will provide finer imaging of gamma-ray sources. Importantly, they will also enable large steps forward in sensitivity by reducing background.

Gehrels, Neil↗

Technical issues in focal plane development for terrestrial resource observations

Performance goals for solid-state detector arrays operating in the pushbroom scan mode for the high-resolution, high-accuracy remote sensing of earth resources from space are discussed and some of the focal plane and system trades involved are identified. Issues in the development of solid-state pushbroom arrays with radiometric calibration to 0.5% precision detector-to-detector over a dynamic range of 1000:1 are considered, with calibration, temporal stability and spectral response conditions noted. Factors influencing the geometric precision of satellite-borne pushbroom scan mode sensors are then examined, including satellite orbit track and attitude errors, and geometric and radiometric correlation between information in the various spectral bands. Approaches to the alignment of linear arrays of thousands of detectors are then discussed that take into account tradeoffs between fabrication and test complexity and ground processing requirements. Continuing science experiments are indicated as necessary to establish tolerances on performance goals.

Thompson, L. L.↗

Astro-D Prelaunch Mission Operation Report (MOR)

The Prelaunch Mission Operation Report for the Astro-D mission is enclosed for your information. Astro-D is a Japanese-led program involving the United States as a participating partner. The Japanese Institute of Space and Astronautical Science (ISAS) provides overall program management, the launch vehicle, the spacecraft, and two Gas Scintillation Imaging System detectors. NASA is providing four nested, thin-foil, grazing-incidence telescope mirrors and two X-ray charged-coupled device solid-state detectors. NASA also provides telemetry tracking support using Deep Space Network ground stations. In return for its scientific instrument contribution, the U.S. will receive 15 percent of the observing time and will share an additional 25 percent for collaborative U.S./Japan scientific investigations. Launch is scheduled for mid- February 1993 from the ISAS launch center near Kagoshima in southern Japan. This MOR: (a) describes the NASA objectives for the Astro-D mission; (b) provides brief descriptions of the spacecraft and its scientific instruments; (c) provides a chronology of launch and deployment; and (d) describes the ground operation elements that support the mission. .

Source record↗

Signal Conditioning for Satellite Borne Energetic-Charged-Particle Experiments

Many of the spacecraft launched thus far have carried detectors for investigating cosmic rays, solar protons, solar plasmas, and the geomagnetically trapped radiation. These detectors, which will find continued application in the future, include ion chambers; proportional, Geiger-Muller, scintillation, Cerenkov, and solid state detectors; ion collectors; and nuclear emulsions. The instrumentation required to condition the signals from these detectors prior to telemetering is steadily growing more complex in order to permit more meaningful measurements. This report describes a number of instrumentation elements typical of the present state of the art, and a present-generation three-detector system which illustrates the integration of such basic elements into a complex system.

Ludwig, George H.↗

Radiation Design of Ion Mass Spectrometers

In the harsh radiation environment of Jupiter and with the JUpiter ICy moon Explorer (JUICE) mission including two Europa flybys where local intensities are approx. 150 krad/month behind 100 mils of Al shielding, so background from penetrating radiation can be a serious issue for detectors inside an Ion Mass Spectrometer (IMS). This can especially be important for minor ion detection designs. Detectors of choice for time-of-flight (TOF) designs are microchannel plates (MCP) and some designs may include solid state detectors (SSD). The standard approach is to use shielding designs so background event rates are low enough that the detector max rates and lifetimes are first not exceeded and then the more stringent requirement that the desired measurement can successfully be made (i.e., desired signal is sufficiently greater than background noise after background subtraction is made). GEANT codes are typically used along with various electronic techniques, but such designs need to know how the detectors will respond to the simulated primary and secondary radiations produced within the instrument. We will be presenting some preliminary measurements made on the response of MCPs to energetic electrons (20 ke V to 1400 ke V) using a Miniature TOF (MTOF) device and the High Energy Facility at Goddard Space Flight Center which has a Van de Graaff accelerator.

Sittler, Ed↗

Study of energetic solar particle events of 18 November 1968, 25 February 1969, and 30 March 1969

The solar particle events of 18 November 1968, 25 February 1969, and 30 March 1969 were studied using data from the detector system aboard the lunar orbiting satellite Explorer 35. Protons, alpha particles, and Z or = 3 nuclei were registered in the solid state detector of the system. Interplanetary propagation, particle anisotropy, and the intensity ratios of protons to alpha particles and of alpha particles to C, N, and O nuclei above a common specific energy of 0.5 MeV/nucleon were studied. Diffusion coefficients and decay constants for the three events are given, as well as magnitudes and directions of anisotropies.

Venkatarangan, P.↗

Hybrid X-ray telescope systems

It has been known for some time that glancing incidence X-ray optics have sharply peaked point response functions. The spatial resolution of Wolter X-ray telescope systems is frequently limited by the performance characteristics of the X-ray detector rather than by the optics, even when high resolution detectors such as photographic emulsions are used. This problem becomes even more severe when it is desirable to take advantage of the high sensitivity and broad wavelength response afforded by modern solid state detectors such as charge coupled devices or multi-anode microchannel arrays. Results of theoretical investigations of methods for increasing the telescope plate scale by the use of glancing incidence hyperboloid/ellipsoid X-ray microscope optics and normal incidence contoured layered synthetic microstructure optics for coupling the Wolter mirrors to the detector are reported. The relative merits of the different hybrid X-ray telescope systems which result will be discussed. Considerations will be made concerning applications of these systems to high resolution imagery and spectroscopy of astronomical X-ray/XUV sources.

Shealy, David L.↗

Techniques in balloon X-ray astronomy.

Since the first balloon observation of the Crab Nebula balloon data have provided much information on the positions, spectra, time variability and pulsed nature of localized sources, and on the spectrum and isotropy of diffuse galactic and universal components. Measurements are limited to energies above about 20 keV by atmospheric attenuation at 2 to 3 g/sq cm depth and to below several hundred keV by detector sensitivity. Detectors usually consist of large-area Na I or Cs I scintillation counters with anticoincidence collimators for rejection of charged particles and scattered X-rays. Proportional counters are occasionally used at lower energies and solid-state detectors are used where extreme energy resolution is important. The instruments require a pointing capability on the order of 1.0 to 0.1 deg, depending on the collimator aperture. Digital data is either recorded on board or telemetered using a PCM technique.

Peterson, L. E.↗

Si and GaAs photocapacitive MIS infrared detectors

Improvement of the previously reported photocapacitive MIS infrared detectors has led to the development of exceptional room-temperature devices. Unoptimized peak detectivities on the order of 10 to the 13th cm sq rt Hz/W, a value which exceeds the best obtainable from existing solid-state detectors, have now been consistently obtained in Si and GaAs devices using high-capacitance LaF3 or composite LaF3/native-oxide insulating layers. The measured spectral response of representative samples is presented and discussed in detail together with a simple theory which accounts for the observed behavior. The response of an ideal MIS photocapacitor is also contrasted with that of both a conventional photoconductor and a p-i-n photodiode, and reasons for the superior performance of the MIS detectors are given. Finally, fundamental studies on the electrical, optical, and noise characteristics of the MIS structures are analyzed and discussed in the context of infrared-detector applications.

Sher, A.↗

Apparatus and method using a holographic optical element for converting a spectral distribution to image points

A holographic optical element transforms a spectral distribution of light to image points. The element comprises areas, each of which acts as a separate lens to image the light incident in its area to an image point. Each area contains the recorded hologram of a point source object. The image points can be made to lie in a line in the same focal plane so as to align with a linear array detector. A version of the element has been developed that has concentric equal areas to match the circular fringe pattern of a Fabry-Perot interferometer. The element has high transmission efficiency, and when coupled with high quantum efficiency solid state detectors, provides an efficient photon-collecting detection system. The element may be used as part of the detection system in a direct detection Doppler lidar system or multiple field of view lidar system.

McGill, Matthew J.↗

Detectors for energies greater than 10 MeV

The detector telescopes used in gamma ray astronomy in general are more similar to particle detectors than to optical devices, since the high frequency of the radiation precludes the use of reflection or diffraction techniques, but the high energy content of each photon does enable them to be detected with scintillators, track imaging chambers, and solid state detectors. Within the gamma ray range, the basic design of the instrument changes as the energy of the gamma ray exceeds 10 to 20 MeV, and therefore, moves from the region where the Compton effect predominates in the absorption of the gamma ray to that where electron pair production is most important. In the energy range from 10 to 20 MeV to several times 10,000 MeV, gamma ray telescopes are usually built so that the electron pair may be seen and the properties of the electrons measured.

Source record↗

Rocket observations of energetic particles at the geomagnetic equator

Energetic particle detectors were included in the payloads of two rockets launched in Peru during the Condor campaign of 1983. These night-time flights reached altitudes of 587 and 535 km, respectively. The pitch-angle distribution is anisotropic with the maximum at 90 deg. Each payload included two solid-state detectors differing in the thickness of the aluminum coating. Comparison of the fluxes measured by the two detectors leads to the conclusion that, on both occasions, the energetic particles are predominantly helium ions. The flux is small below 200 km, increases linearly to 350 km, and then more slowly to apogee. The east-west asymmetry of flux, noted at 200 km in a previous equatorial launch, is not seen at greater altitudes, consistent with the flux profile and the large gyroradius of the ions.

Smith, L. G.↗

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

Delta-Doped CCDs as Detector Arrays in Mass Spectrometers

In a conventional mass spectrometer, charged particles (ions) are dispersed through a magnetic sector onto an MCP at an output (focal) plane. In the MCP, the impinging charged particles excite electron cascades that afford signal gain. Electrons leaving the MCP can be read out by any of a variety of means; most commonly, they are post-accelerated onto a solid-state detector array, wherein the electron pulses are converted to photons, which, in turn, are converted to measurable electric-current pulses by photodetectors. Each step in the conversion from the impinging charged particles to the output 26 NASA Tech Briefs, February 2007 current pulses reduces spatial resolution and increases noise, thereby reducing the overall sensitivity and performance of the mass spectrometer. Hence, it would be preferable to make a direct measurement of the spatial distribution of charged particles impinging on the focal plane. The utility of delta-doped CCDs as detectors of charged particles was reported in two articles in NASA Tech Briefs, Vol. 22, No. 7 (July 1998): "Delta-Doped CCDs as Low-Energy-Particle Detectors" (NPO-20178) on page 48 and "Delta- Doped CCDs for Measuring Energies of Positive Ions" (NPO-20253) on page 50. In the present developmental miniature mass spectrometers, the above mentioned miniaturization and performance advantages contributed by the use of delta-doped CCDs are combined with the advantages afforded by the Mattauch-Herzog design. The Mattauch- Herzog design is a double-focusing spectrometer design involving an electric and a magnetic sector, where the ions of different masses are spatially separated along the focal plane of magnetic sector. A delta-doped CCD at the focal plane measures the signals of all the charged-particle species simultaneously at high sensitivity and high resolution, thereby nearly instantaneously providing a complete, high-quality mass spectrum. The simultaneous nature of the measurement of ions stands in contrast to that of a scanning mass spectrometer, in which abundances of different masses are measured at successive times.

Nikzad, Shouleh↗