Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography

Purpose: The noise variance versus spatial resolution relationship in differential phase contrast (DPC) projection imaging and computed tomography (CT) are derived and compared to conventional absorption-based x-ray projection imaging and CT. Methods: The scaling law for DPC-CT is theoretically derived and subsequently validated with phantom results from an experimental Talbot-Lau interferometer system. Results: For the DPC imaging method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both in theory and experimental results, in DPC-CT the noise variance scales with spatial resolution following an inverse linear relationship with fixed slice thickness. Conclusions: The scaling law in DPC-CT implies a lesser noise, and therefore dose, penalty for moving to higher spatial resolutions when compared to conventional absorption-based CT in order to maintain the same contrast-to-noise ratio.

60 APPLIED LIFE SCIENCES↗

New Lens-Free X-ray Source for Laboratory Nano-CT with 50-nm Spatial Resolution

X-ray optics, such as zone plates, are often used to obtain a spatial resolution better than 100 nm in x-ray projection images. Such types of optics are not always suited for tomographic imaging due to their limited depth of focus, which restricts the size of the specimen to a few microns. To overcome these limitations, we developed a new lens-free setup for a nano-CT system. Spatial resolution of nano-CT systems is mainly defined by x-ray source performance. It is dependent on target shape and focusing of the electron beam. The typical way to improve spatial resolution is based on replacement of the bulk metal target to thin film. It allows getting submicron spot size, but significantly reduces x-ray flux. To overcome flux limitation without compromising with spatial resolution, we invented a new type of target shaped as a rod or needle towards the camera. It allows us to reach 50-nm resolution with reasonable flux.

07 ISOTOPE AND RADIATION SOURCES↗

Estimation of Orbital Neutron Detector Spatial Resolution by Systematic Shifting of Differential Topographic Masks

We present a method and preliminary results related to determining the spatial resolution of orbital neutron detectors using epithermal maps and differential topographic masks. Our technique is similar to coded aperture imaging methods for optimizing photonic signals in telescopes [I]. In that approach photon masks with known spatial patterns in a telescope aperature are used to systematically restrict incoming photons which minimizes interference and enhances photon signal to noise. Three orbital neutron detector systems with different stated spatial resolutions are evaluated. The differing spatial resolutions arise due different orbital altitudes and the use of neutron collimation techniques. 1) The uncollimated Lunar Prospector Neutron Spectrometer (LPNS) system has spatial resolution of 45km FWHM from approx. 30km altitude mission phase [2]. The Lunar Rennaissance Orbiter (LRO) Lunar Exploration Neutron Detector (LEND) with two detectors at 50km altitude evaluated here: 2) the collimated 10km FWHM spatial resolution detector CSETN and 3) LEND's collimated Sensor for Epithermal Neutrons (SETN). Thus providing two orbital altitudes to study factors of: uncollimated vs collimated and two average altitudes for their effect on fields-of-view.

McClanahan, T. P.↗

Calculation of the spatial resolution in two-photon absorption spectroscopy applied to plasma diagnosis

We report a detailed characterization of the spatial resolution provided by two-photon absorption spectroscopy suited for plasma diagnosis via the 1S-2S transition of atomic hydrogen for optogalvanic detection and laser induced fluorescence (LIF). A precise knowledge of the spatial resolution is crucial for a correct interpretation of measurements, if the plasma parameters to be analysed undergo strong spatial variations. The present study is based on a novel approach which provides a reliable and realistic determination of the spatial resolution. Measured irradiance distribution of laser beam waists in the overlap volume, provided by a high resolution UV camera, are employed to resolve coupled rate equations accounting for two-photon excitation, fluorescence decay and ionization. The resulting three-dimensional yield distributions reveal in detail the spatial resolution for optogalvanic and LIF detection and related saturation due to depletion. Two-photon absorption profiles broader than the Fourier transform-limited laser bandwidth are also incorporated in the calculations. The approach allows an accurate analysis of the spatial resolution present in recent and future measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High spatial resolution measurements of ram accelerator gas dynamic phenomena

High spatial resolution experimental tube wall pressure measurements of ram accelerator gas dynamic phenomena are presented. The projectile resembles the centerbody of a ramjet and travels supersonically through a tube filled with a combustible gaseous mixture, with the tube acting as the outer cowling. Pressure data are recorded as the projectile passes by sensors mounted in the tube wall at various locations along the tube. Data obtained by using a special highly instrumented section of tube has allowed the recording of gas dynamic phenomena with a spatial resolution on the order of one tenth the projectile length. High spatial resolution tube wall pressure data from the three regimes of propulsion studied to date (subdetonative, transdetonative, and superdetonative) are presented and reveal the 3D character of the flowfield induced by projectile fins and the canting of the projectile body relative to the tube wall. Also presented for comparison to the experimental data are calculations made with an inviscid, 3D CFD code.

Hinkey, J. B.↗

The effect of spatial resolution upon texture-based cloud field classifications

The loss of cloud-classification accuracy as a function of spatial resolution is assessed by investigating the variation of textural measures as a function of spatial resolution. Landsat MSS imagery is progressively averaged to produce degraded imagery of 1/8-km, 1/4-km, 1/2-km, and 1-km spatial resolution, and textural measures are computed from the Gray Level Difference Vector (GLDV) approach described by Chen et al. (1989). It is found that the classification accuracies obtained using the 1/8-km spatial resolution data are similar to those obtained using the full-resolution (1/16 km) texture measures, indicating that there is no advantage in using even higher spatial resolution 30-m Landsat Thematic Mapper and 10-m SPOT imagery for cloud classification.

Welch, R. M.↗

Sub-pixel Spatial Resolution Micro-roughness Measurements with Interlaced Stitching

In this paper we describe a method to increase the spatial resolution of surface micro-roughness measurements. As the surface specifications for precision optics become more demanding, the metrology instruments must cover a broad spatial frequency range. Generally, multiple instruments are used to cover the full range of the specifications. For example, a Fizeau interferometer would be used to test low spatial frequency surface errors, a white light interferometer would be used for mid spatial frequency errors, and an AFM would be used for high spatial frequency errors. For some precision optics, three instruments would be necessary. However, in many applications, an increase in the spatial resolution of a metrology instrument could negate the need for multiple instruments. A solution to increase the spatial resolution of micro-roughness measurements obtained using white light interferometry with "interlaced stitching" will be presented. In "interlaced stitching", multiple interferometric measurements are made as the optic under test (or the CCD array) is laterally shifted at sub-pixel increments. The measurements are then combined to construct a measurement with higher spatial resolution. Initial results obtained while implementing a similar process used to increase the spatial resolution of measurements made with a commercially available Fizeau interferometer will be presented.

Mooney, James T.↗

Effects of Spatial Resolution on the Simulated Dust Aerosol Lifecycle: Implications for Dust Event Magnitude and Timing in the NASA GEOS-5 AGCM

The NASA GEOS-5 atmospheric transport model simulates global aerosol distributions with an online aerosol module. GEOS-5 may be run at various horizontal spatial resolutions depending on the research application. For example, long integration climate simulations are typically run at 2 deg or 1 deg grid spacing, whereas aerosol reanalysis and forecasting applications may be performed at O.5 deg or 0.25 deg resolutions. In this study, we assess the implications of varying spatial resolution on the simulated aerosol fields, with a particular focus on dust. Dust emissions in GEOS-5 are calculated with one of two parameterizations, one based on the Goddard Chemistry, Aerosol, Radiation, and Transport (GO CART) model and another based on the Dust Entrainment and Deposition (DEAD) model. Emission fluxes are parameterized in terms of the surface wind speed, either the 10-m (GO CART) or friction (DEAD) wind speed. We consider how surface wind speeds and thus the dust emission rates are a function of the model spatial resolution. We find that spatial resolution has a significant effect on the magnitude of dust emissions, as higher resolution versions of the model have typically higher surface wind speeds. Utilizing space-borne observations from MISR, MODIS, and CALIOP, we find that simulated Aerosol Optical Thickness (AOT) distributions respond differently to spatial resolution over the African and Asian source regions, highlighting the need to regional dust emission tuning. When compared to ground-based observations from AERONET, we found improved timing of dust events with as spatial resolution was increased. In an attempt to improve the representation of the dust aerosol lifecycle at coarse resolutions, we found that incorporating the effects of sub-grid wind variability in a course resolution simulation led to improved agreement with observed AOT magnitudes, but did not impact the timing of simulated dust events.

Nowottnick, E.↗

Some effects of finite spatial resolution on skin friction measurements in turbulent boundary layers

The effects of finite spatial resolution often cause serious errors in measurements in turbulent boundary layers, with particularly large effects for measurements of fluctuating skin friction and velocities within the sublayer. However, classical analyses of finite spatial resolution effects have generally not accounted for the substantial inhomogeneity and anisotropy of near-wall turbulence. The present study has made use of results from recent computational simulations of wall-bounded turbulent flows to examine spatial resolution effects for measurements made at a wall using both single-sensor probes and those employing two sensing volumes in a V shape. Results are presented to show the effects of finite spatial resolution on a variety of quantitites deduced from the skin friction field.

Westphal, Russell V.↗

Experimental Estimation of CLASP Spatial Resolution: Results of the Instrument's Optical Alignment

The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a sounding-rocket experiment currently being built at the National Astronomical Observatory of Japan. This instrument aims to probe for the first time the magnetic field strength and orientation in the solar upper-chromosphere and lower-transition region. CLASP will measure the polarization of the Lyman-Alpha line (121.6nm) with an unprecedented accuracy, and derive the magnetic field information through the Hanle effect. Although polarization accuracy and spectral resolution are crucial for the Hanle effect detection, spatial resolution is also important to get reliable context image via the slit-jaw camera. As spatial resolution is directly related with the alignment of optics, it is also a good way of ensuring the alignment of the instrument to meet the scientific requirement. This poster will detail the experiments carried out to align CLASP's optics (telescope and spectrograph), as both part of the instrument were aligned separately. The telescope was aligned in double-pass mode, and a laser interferometer (He-Ne) was used to measure the telescope's wavefront error (WFE). The secondary mirror tilt and position were adjusted to remove comas and defocus aberrations from the WFE. Effect of gravity on the WFE measurement was estimated and the final WFE derived in zero-g condition for CLASP telescope will be presented. In addition, an estimation of the spot shape and size derived from the final WFE will also be shown. The spectrograph was aligned with a custom procedure: because Ly-light is absorbed by air, the spectrograph's off-axis parabolic mirrors were aligned in Visible Light (VL) using a custom-made VL grating instead of the flight Ly- grating. Results of the alignment in Visible Light will be shown and the spot shape recorded with CCDs at various position along the slit will be displayed. Results from both alignment experiment will be compared to the design requirement, and will be combined in order to estimate CLASP spatial resolution after its alignment in visible light.

spatial resolution↗

High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisition

Purpose: One of the technical advantages of functional magnetic resonance imaging (fMRI) is its precise localization of changes from neuronal activities. While current practice of fMRI acquisition at voxel size around 3 × 3 × 3 mm{sup 3} achieves satisfactory results in studies of basic brain functions, higher spatial resolution is required in order to resolve finer cortical structures. This study investigated spatial resolution effects on brain fMRI experiments using balanced steady-state free precession (bSSFP) imaging with 0.37 mm{sup 3} voxel volume at 3.0 T. Methods: In fMRI experiments, full and unilateral visual field 5 Hz flashing checkerboard stimulations were given to healthy subjects. The bSSFP imaging experiments were performed at three different frequency offsets to widen the coverage, with functional activations in the primary visual cortex analyzed using the general linear model. Variations of the spatial resolution were achieved by removing outerk-space data components. Results: Results show that a reduction in voxel volume from 3.44 × 3.44 × 2 mm{sup 3} to 0.43 × 0.43 × 2 mm{sup 3} has resulted in an increase of the functional activation signals from (7.7 ± 1.7)% to (20.9 ± 2.0)% at 3.0 T, despite of the threefold SNR decreases in the original images, leading to nearly invariant functional contrast-to-noise ratios (fCNR) even at high spatial resolution. Activation signals aligning nicely with gray matter sulci at high spatial resolution would, on the other hand, have possibly been mistaken as noise at low spatial resolution. Conclusions: It is concluded that the bSSFP sequence is a plausible technique for fMRI investigations at submillimeter voxel widths without compromising fCNR. The reduction of partial volume averaging with nonactivated brain tissues to retain fCNR is uniquely suitable for high spatial resolution applications such as the resolving of columnar organization in the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images

Purpose: To develop and validate an automated technique for evaluating the spatial resolution characteristics of clinical computed tomography (CT) images. Methods: Twenty one chest and abdominopelvic clinical CT datasets were examined in this study. An algorithm was developed to extract a CT resolution index (RI) analogous to the modulation transfer function from clinical CT images by measuring the edge-spread function (ESF) across the patient’s skin. A polygon mesh of the air-skin boundary was created. The faces of the mesh were then used to measure the ESF across the air-skin interface. The ESF was differentiated to obtain the line-spread function (LSF), and the LSF was Fourier transformed to obtain the RI. The algorithm’s ability to detect the radial dependence of the RI was investigated. RIs measured with the proposed method were compared with a conventional phantom-based method across two reconstruction algorithms (FBP and iterative) using the spatial frequency at 50% RI, f{sub 50}, as the metric for comparison. Three reconstruction kernels were investigated for each reconstruction algorithm. Finally, an observer study was conducted to determine if observers could visually perceive the differences in the measured blurriness of images reconstructed with a given reconstruction method. Results: RI measurements performed with the proposed technique exhibited the expected dependencies on the image reconstruction. The measured f{sub 50} values increased with harder kernels for both FBP and iterative reconstruction. Furthermore, the proposed algorithm was able to detect the radial dependence of the RI. Patient-specific measurements of the RI were comparable to the phantom-based technique, but the patient data exhibited a large spread in the measured f{sub 50}, indicating that some datasets were blurrier than others even when the projection data were reconstructed with the same reconstruction algorithm and kernel. Results from the observer study substantiated this finding. Conclusions: Clinically informed, patient-specific spatial resolution can be measured from clinical datasets. The method is sufficiently sensitive to reflect changes in spatial resolution due to different reconstruction parameters. The method can be applied to automatically assess the spatial resolution of patient images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

Super-resolution model for overlapping peak detection and improved spatial resolution in high-energy diffraction microscopy

Reconstruction quality in Far-field High-Energy Diffraction Microscopy (FF-HEDM) is limited by the spatial resolution of area detectors and the frequent occurrence of overlapping diffraction spots. To address these challenges, we developed a super-resolution (SR) framework using convolutional neural networks (CNNs) to recreate 2D diffraction peaks at up to ×8 resolution from raw detector data. A specialized simulation tool was created to generate synthetic training datasets with varying degrees of peak overlap. Integrated into the Microstructural Imaging using Diffraction Analysis Software (MIDAS), the SR model improves the spatial accuracy and precision of 3D grain reconstruction by an order of magnitude. This approach provides a robust solution for investigation of complex micromechanical states and material classes where the analysis is limited by the presence of overlapping peaks. Furthermore, the methodology developed here can potentially be extended to other techniques that require sub-pixel accuracy for high-fidelity data analysis.

High-energy diffraction microscopy↗

Spatially resolved and observer-free experimental quantification of spatial resolution in tomographic images

We present a novel framework and experimental method for the quantification of spatial resolution of a tomography system. The framework adopts the “black box” view of an imaging system, considering only its input and output. The tomography system is locally stimulated with a step input, viz., a sharp edge. The output, viz., the reconstructed images, is analysed by Fourier decomposition of their spatial frequency components, and the local limiting spatial resolution is determined using a cut-off threshold. At no point is an observer involved in the process. The framework also includes a means of translating the quantification region in the imaging space, thus creating a spatially resolved map of objectively quantified spatial resolution. As a case-study, the framework is experimentally applied using a gaseous propane phantom measured by a well-established chemical species tomography system. A spatial resolution map consisting of 28 regions is produced. In isolated regions, the indicated performance is 4-times better than that suggested in the literature and varies by 57% across the imaging space. A mechanism based on adjacent but non-interacting beams is hypothesised to explain the observed behaviour. The mechanism suggests that, as also independently concluded by other methods, a geometrically regular beam array maintains maximum objectivity in reconstructions. We believe that the proposed framework, methodology, and findings will be of value in the design and performance evaluation of tomographic imaging arrays and systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Simulations of Vegetation Dynamics over the Tibetan Plateau: Role of Atmospheric Forcing Data and Spatial Resolution

The efficacy of vegetation dynamics simulations in offline land surface models (LSMs) largely depends on the quality and spatial resolution of meteorological forcing data. In this study, the Princeton Global Meteorological Forcing Data (PMFD) and the high spatial resolution and upscaled China Meteorological Forcing Data (CMFD) were used to drive the Simplified Simple Biosphere model version 4/Top-down Representation of Interactive Foliage and Flora Including Dynamics (SSiB4/TRIFFID) and investigate how meteorological forcing datasets with different spatial resolutions affect simulations over the Tibetan Plateau (TP), a region with complex topography and sparse observations. By comparing the monthly Leaf Area Index (LAI) and Gross Primary Production (GPP) against observations, we found that SSiB4/TRIFFID driven by upscaled CMFD improved the performance in simulating the spatial distributions of LAI and GPP over the TP, reducing RMSEs by 24.3% and 20.5%, respectively. The multi-year averaged GPP decreased from 364.68 gC m –2 yr –1 to 241.21 gC m –2 yr –1 with the percentage bias dropping from 50.2% to –1.7%. When using the high spatial resolution CMFD, the RMSEs of the spatial distributions of LAI and GPP simulations were further reduced by 7.5% and 9.5%, respectively. This study highlights the importance of more realistic and high-resolution forcing data in simulating vegetation growth and carbon exchange between the atmosphere and biosphere over the TP.

54 ENVIRONMENTAL SCIENCES↗

Introduction to the Sub-pixel Spatial Resolution Interferometry Process

In this paper we describe a method called "Sub-Pixel Spatial Resolution Interferometry" used to increase the spatial resolution of interferometric measurements of precision optical surfaces. In this process, multiple interferometric measurements are made as the optic under test (or the CCD array)in shifted at sub-pixel increments. The measurements are then combined to construct a measurement with higher spatial resolution than the original measurements. The process will be described and initial results obtained using this process with a commercially available Fizeau interferometer will be presented.

Mooney, James T.↗

Additional studies of forest classification accuracy as influenced by multispectral scanner spatial resolution

First, an analysis of forest feature signatures was used to help explain the large variation in classification accuracy that can occur among individual forest features for any one case of spatial resolution and the inconsistent changes in classification accuracy that were demonstrated among features as spatial resolution was degraded. Second, the classification rejection threshold was varied in an effort to reduce the large proportion of unclassified resolution elements that previously appeared in the processing of coarse resolution data when a constant rejection threshold was used for all cases of spatial resolution. For the signature analysis, two-channel ellipse plots showing the feature signature distributions for several cases of spatial resolution indicated that the capability of signatures to correctly identify their respective features is dependent on the amount of statistical overlap among signatures. Reductions in signature variance that occur in data of degraded spatial resolution may not necessarily decrease the amount of statistical overlap among signatures having large variance and small mean separations. Features classified by such signatures may thus continue to have similar amounts of misclassified elements in coarser resolution data, and thus, not necessarily improve in classification accuracy.

Sadowski, F. E.↗

Methods of improving spatial resolution for IR spectroscopy in atmospheric-pressure plasma systems

High-temperature, atmospheric pressure plasma systems operated in molecular gases present complex diagnostic challenges. Infrared spectroscopy has been used to make measurements of the absorbance spectrum of complex molecular gas mixtures and thereby calculate the concentrations and species temperatures in these systems. For atmospheric-pressure systems, high spatial gradients arise and high spatial-resolution measurements are thus desirable. Some systems have achieved increased spatial resolution by reducing the beam diameter. However, this increase in spatial resolution comes at the expense of the optical throughput. Here we propose modifying a commercial Fourier Transform, Infrared spectrometer system with a set of simple optical elements. This design allows for scannable, high spatial resolution absorbance spectrum measurements of a complex molecular gas mix. We analyze the signal-to-noise ratio for this design and compare it with the diameter reduction method. For sufficiently low plasma radiation levels, this design improves the signal-to-noise ratio relative to reducing the beam diameter size while transmitting nearly all of the beam power. Furthermore, whether this design can achieve the desired sub-mm spatial resolution depends on the radiating area of the infrared light source in the spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗