Search NASASearch

SEARCH · Search NASA

Results for “specific heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

404 records · Page 4

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

The Design and Use of Calorimeters For Characterization of High-Enthalpy Flows in Arc-Heated Test Facilities

High-enthalpy, arc-heated flows used for aerothermal testing present a challenging environment for flow characterization. This paper describes the design and use of cooled dwell probes used for heat-transfer and pressure characterization of the NASA and United States Department of Defense (DoD) arc facilities located at Moffett Field, CA, and Arnold Air Force Base, TN. Dwell calorimeters designed, fabricated, and tested by Thermal Technologies, Inc. (TTI) in the NASA IHF and the USAF H1 and H2 arc test facilities provide heat flux and pressure data with excellent repeatability. These calorimeters use standard Gardon calorimeter gages and pressure ports with unique cooling systems enabling them to withstand the severe arc-heated environments for durations sufficient for acquisition of steady-state data. The TTI probes have proven very robust in the extreme aerothermal environments of these facilities. This paper provides an overview of calorimeter instruments typically used in arc facilities, discusses design features of the TTI dwell probes, presents selected data acquired by the TTI calorimeters, and provides comparisons with data acquired from using measurement techniques.

D Mark Smith

Aerothermal Shape Optimization of Actively-Cooled Battery Packs Using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

heat transfer

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

Aerothermal Shape Optimization of Actively-Cooled Battery Packs using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

thermal management

Thermal Considerations for 2039 Opposition Class Nuclear Electric Propulsion/Chemical Propulsion Crewed Mars Mission

The high specific impulse (Isp) of Nuclear Electric Propulsion (NEP) technology offers the potential for advanced space mission capabilities. However, the five critical technology elements of NEP vehicles have yet to prove technical maturity levels for consideration into mission design. In response to the critical reviews by the NASA Engineering and Safety Center (NESC) and the National Academies of Sciences, Engineering, and Medicine (NASEM), NASA’s Space Nuclear Propulsion (SNP) project created an NEP Technology Maturation Plan (TMP) for focused development of NEP technology. The TMP called for a coordinated set of technology development efforts to meet this objective. The Modular Assembled Radiators for NEP VehicLes (MARVL) Early Career Initiative (ECI) project was initiated to develop a portion of the fifth Critical Technology Element (CTE) of the NEP vehicle: the Primary Heat Rejection Subsystem (PHRS). A target application of a 2039 human-rated Mars mission was outlined in the TMP. For the outlined mission, a NEP vehicle will experience several thermal environments which will impact the design and operation of the PHRS. To maintain radiator temperatures within the required effective temperature range, the effect of natural, induced, and NEP internally generated heat loads on the radiator panel must be well understood. Furthermore, this analysis is critical for analyzing the influence of various orientations and positions of the NEP vehicle relative to nearby celestial bodies throughout the mission. This study conducted a complete enveloping analysis of the thermal environments influencing the NEP vehicle throughout the mission. Thermal analysis was conducted for the radiator panels based on the defined mission environments. This thermal analysis concludes with the selection of ideal radiator orientations for the NEP vehicle, and the identification of worst case hot and cold environmental sink temperatures throughout the mission. For the target application, the environmental sink temperature while the reactor is powered OFF or powered ON ranges from 30 K to 353 K and 2.7 K to 243 K respectively. When considering interplanetary space, the minimum environmental sink temperature when the reactor is powered OFF and the radiators are oriented “edge to Sun” is 2.7 K. The environmental thermal models generated in this study will be used for future studies with the full vehicle system model. The environmental sink temperature curves generated will be used for future radiator and component analysis to predict transient performance in the space environment. The environmental sink temperature and heat rejection capability curves will inform the trade between commissioning orbits that are in consideration. The model may also serve as a useful tool as reference for future crewed space missions, missions involving radiators or temperature sensitive equipment, or other missions requiring analysis of natural orbital thermal environments.

Nuclear Electric Propulsion

Simulated Lunar Gravity Testing of VIPER Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) mission consists of a rover designed to explore the lunar south pole. One of the main challenges faced by the rover during the lunar polar exploration is the adverse thermal environment. Temperatures can fluctuate more than a 100°C between day and night; potentially dropping to −246°C in permanent shadow regions. To maintain the rover components within temperature limits, VIPER’s Thermal Management System (TMS) relies heavily on Loop Heat Pipes (LHPs). To assist the design of the thermal management system, an Engineering Design Unit (EDU) LHP has been tested in several opportunities under thermal vacuum (TVAC) environment. Of particular interest was the LHP performance in lunar gravity. To that end, the EDU LHP was tested at the nominal orientation within the rover assembly, vertical, and inclined such that the gravitational component acting on the LHP evaporator and condenser was 1/6g (lunar gravity is 1/6 of Earth gravity) when compared to the vertical configuration. This paper will examine the LHP conductance as one the key parameters to assess the effect of the gravity on the LHP performance.

Loop Heat Pipe

Microstructural Evolution and Mechanical Properties of LP-DED NASA HR-1 – A Hydrogen Resistant AM Superalloy for Space Propulsion Applications

The National Aeronautics and Space Administration (NASA) has actively pursued metal additive manufacturing (AM) technologies for spaceflight applications since the late 2000s. AM offers transformative advantages in cost, schedule, part consolidation, and design flexibility. Among the various AM techniques, laser powder directed energy deposition (LP-DED) is particularly well suited for fabricating complex geometries with fine feature resolution. In propulsion systems that utilize high-pressure gaseous hydrogen—such as liquid hydrogen rocket engines—hydrogen environment embrittlement (HEE) presents a serious threat to material performance 1,2 . Mechanical property degradation under these conditions can compromise component reliability, especially under cyclic loading. To address this challenge, NASA developed NASA HR-1 (Hydrogen Resistant-1) as a solution for liquid rocket engine components operating in hydrogen-rich environments, using the LP-DED technique 3-9 . A key component in a liquid rocket engine is the exhaust nozzle, which is typically regeneratively cooled (regen) due to the high heat flux. NASA HR-1 was specifically developed for regen nozzle applications using hydrogen as a propellant, providing resistance to HEE, a critical issue for many materials. The AM version of NASA HR-1 was also formulated to achieve high ultimate tensile strength, along with high yield strength and ductility in this environment 5,6 . Low-cycle fatigue (LCF) is another important consideration in nozzle design, as components are expected to endure multiple starts and missions. Additionally, the LP-DED version of the alloy exhibits improved thermal conductivity compared to its wrought counterpart, which benefits nozzle cooling. Overall, NASA HR-1 offers an excellent balance of high strength, HEE resistance, LCF performance, thermal conductivity, and ductility to meet the demanding requirements of channel-cooled nozzles and other components used with hydrogen and other propellants. The LP-DED–processed NASA HR-1 requires several post-processing heat treatment steps to achieve the material properties desirable for its intended application 6 . These steps include stress relief, homogenization, solution annealing, and aging for precipitation hardening. The stress relief treatment mitigates residual stresses accumulated during the LP-DED process and minimizes the potential for distortion. Homogenization, a common step for AM materials, reduces elemental segregation and promotes recrystallization to develop a more equiaxed grain structure. The subsequent solution annealing treatment heats the part to a solid solution temperature to dissolve the undesirable η-phase that forms during cooling from homogenization, followed by rapid cooling to retain an η-phase–free microstructure. Finally, aging promotes precipitation of the strengthening γ′ phase in the alloy. The integration of compositional design and optimized thermal processing enables high-quality LP-DED NASA HR-1 components with excellent microstructural and mechanical stability. Improved chemical and microstructure homogeneity enhances ductility and fatigue resistance—both critical for safe and reliable operation in high-pressure hydrogen environments. NASA has successfully fabricated and hot-fire tested multiple subscale and full-scale channel wall nozzles using LP-DED NASA HR-1 5,6, 9-14 . These efforts included process refinements to support thin-wall construction and various channel geometries. Throughout development, several key observations emerged. After homogenization, the as-built columnar grain structure transforms into a fully equiaxed microstructure. However, subsequent treatments—such as solution annealing and aging—result in changes that are more difficult to track. The grain structure remains largely unchanged, and the γ′ precipitates, typically 5–10 nm in diameter, are beyond the resolution of scanning electron microscopy (SEM). While transmission electron microscopy (TEM) can resolve these fine precipitates, TEM sample preparation is time-consuming and difficult for LP-DED material. As an alternative, differential scanning calorimetry (DSC) offers a useful, qualitative approach to monitor precipitate evolution throughout different stages of heat treatment. The overall goal is to improve the understanding of how heat treatment affects the microstructure and mechanical performance of LP-DED NASA HR-1. This paper presents heat treatment design considerations, microstructural characterization, mechanical testing – including tensile and LCF testing in both air and hydrogen environments.

Superalloy

Cryogenic Flow Boiling in Microgravity: Effects of Reduced Gravity on Two-Phase Fluid Physics and Heat Transfer

With the growing interest in space exploration, cryogenic technologies involving two-phase flow and heat transfer are in high demand to successfully procure advanced space applications such as fuel depots and nuclear thermal propulsion (NTP) systems for deep space missions. However, the unique and extreme thermal properties of cryogenic fluids introduce distinct flow boiling fluid physics and energy transport phenomena, which differ significantly from those observed with conventional fluids. Understanding the unique two-phase physics in cryogenic flow boiling remains an ongoing challenge. Furthermore, the lack of readily available microgravity cryogenic steady-state heat transfer data hinders the assessment of gravitational effects on cryogenic flow boiling. This study aims to elucidate the gravitational effects on two-phase fluid physics and heat transfer by conducting the first-ever experimental measurement of cryogenic flow boiling performance using a steady-state heated method in a reduced gravity environment. Parabolic flight experiments were performed to acquire both heat transfer measurements and high-speed video of interfacial behaviors, under varying gravity levels (microgravity, hypergravity, Lunar gravity, and Martian gravity). The experiments involved flow boiling of liquid nitrogen (LN 2 ) with a near-saturated inlet along a circular heated tube of dimensions 8.5-mm inner diameter and 680-mm heated length. The operating parameters varied are mass velocity of 398.3 - 1342.8 kg/m2s, inlet quality of -0.08 to -0.01, and inlet pressure of 413.68 - 689.48 kPa. Captured microgravity flow patterns range from bubbly to annular, all having vapor structures that are larger than those under higher gravity levels. Under microgravity, absence of buoyancy yields symmetrical vapor structures without flow stratification, laying a physical foundation for the distinct two-phase heat transfer trends during LN 2 flow boiling in microgravity. Transient data collected during the flight parabolas exhibited decreasing heated wall temperature as the aircraft transitioned from hypergravity to microgravity phases. The temperature variation indicated an enhancement in flow boiling heat transfer with decreasing gravity levels and a reduction with increasing gravity levels. The effect of reduced gravity on cryogenic flow boiling heat transfer coefficient (HTC) is discussed based on steady state heat transfer analysis. Seminal HTC correlations are evaluated against the measured microgravity HTC data, of which one is identified for superior accuracy in predicting microgravity data. Finally, a new HTC correlation is proposed to improve accuracy of microgravity predictions, yet there still exists room for further improvement with future terrestrial flow boiling experiments at different flow orientations relative to Earth gravity.

Microgravity

NASA Alternative Orion Small Cell Battery Design Support

The NASA Orion Crew Module Reference Design was produced to address large scale thermal runaway (TR) hazard with specific safety controls for the Orion Spacecraft. The design presented provides the description of a full scale battery design reference for implementation as a drop in replacement to meet all spacecraft energy requirements with compatible 120 Vdc electrical and mechanical interface using small cell technology (18650) packaging. The 32V SuperBrick incorporates unique support features and an electrical bus bar arrangement that allows cells negative can insertion into heat sink that is compressively coupled to the battery enclosure to promote good thermal management. The housing design also provides an internal flame suppression "filter tray" and positive venting path internal to the enclosure to allow hot effluent ejecta to escape in the event of single cell TR. Virtual cells (14P Banks) that are supported to provide cell spacing with interstitial materials to prevent side can failures that can produce cell to cell TR propagation. These features were successfully test in four separate TR run with the full scale DTA1 test article in February 2016. Successfully Completed Test Objectives - Four separate TR test runs with Full-Scale DTA1 housing with Two SuperBricks, Two SuperBrick Emulators All Tests resulted in "clean" gas with less than 6 C rise at Battery vent All Tests resulted in less than 2 C temperature rise on cold-plate outlet All Tests resulted in less than 6 psi pressure rise in the battery housing Test Run 1 -One neighbor cell TR, highest remaining neighbor 139 C. Ejecta shorted to bus caused prolonged additional heating, One shorted cell did experience TR after 12 minutes, remaining cells had adequate thermal margin Test Run 2 - No cell to cell propagation, highest neighbor cell 112 C; Test Run 3 - No cell to cell propagation, highest neighbor cell 96 C; Test Run 4 - No cell to cell propagation, highest neighbor cell 101 C; Primary TR testing and analysis were completed and reviewed for endorsement by NASA Engineering and Safety Center team members. All Key Test Objectives were met and the small cell design alternative was demonstrated and selected to be a feasible drop in replacement for the MPCV Orion CM Battery for EM2 mission.

Haynes, Chuck

The Use of Immersion Rigs for High Temperature Hydrogen Exposure Testing Within the Nuclear Thermal Rocket Element Environmental Simulator (NTREES): NTREES-5 Hydrogen Heat Exchanger (N5HHX-01)

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility at NASA’s Marshall Space Flight Center (MSFC) subjects materials and components typically found on nuclear thermal propulsion (NTP) systems to non-nuclear simulations of prototypic NTP reactor thermohydraulic environments. With 1.2 MW of inductive power available, the currently employed methods to simulate nuclear heating in NTREES consist of 1) inductively heating a test specimen, which typically cannot be performed on ceramic materials, or 2) heating gas that envelops the test specimen. The latter of these has provided a basis for developing so-called “immersion rigs” to be used in NTREES. Furthermore, immersion rigs are especially useful in the case of smaller, technically challenging test specimens. One such device, the “NTREES-5 Hydrogen Heat Exchanger” (N5HHX-01), designed and deployed to test small material coupons to ~0.5 g/s of 2800 K, 500 psi Hydrogen, is discussed herein. To achieve this desired delivery temperature level, the most suitable material for the N5HHX’s construction was pure tungsten, which imposed budgetary and manufacturing challenges. Also discussed in this paper is the design of the N5HHX rig’s sample container, which became the first iteration of improving NTREES small material coupon test operations by permitting rapid changeout of different material samples.

Reactor Testing

Heat Capacity and Thermal Relaxation of Bulk Helium Very Near the Lambda Point

In October 1992 a low temperature experiment was flown on the Space Shuttle in low Earth orbit. The objective of the mission was to measure the heat capacity and thermal conductivity of helium very close to the lambda point with the smearing effect of gravity removed. We report preliminary results from the experiment, and compare them with related measurements performed on the ground. The sample was s sphere of helium 3.5 cm in diameter contained within a copper calorimeter of vey high thermal conductivity. The calorimeter was attached to a pair of high resolution paramagnetic salt thermometers with noise levels in the 10 -10 K range and suspended from a high stability thermal isolation system. During the mission we found that the resolution of the thermometers was degraded somewhat due to the impact of charged particles. This effect limited the useful resolution of the measurements to about two nanokelvins from the lambda point. The results reported here are limited to about ten nanokelvins from the transition.

John A Lipa