Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Asteroid shapes from radar echo spectra - A new theoretical approach

Asteroid shape determinations are presently made by means of a novel technique based on the geometric relation between spectral edge frequencies and the shape of a rotating, rigid radar target. By employing the echo spectra obtained at many rotational phases, the asteroid's convex polar silhouette hull is obtained; noise content is treated as a problem in weighted-least-squares optimization, subject to inequality constraints. The performance of this estimation method is assessed in a series of simulated data giving attention to spectral noise propagation into hull error; sensitivity to echo strength and spectral resolution are also evaluated.

Ostro, Steven J.↗

Spectral characteristics of time-dependent orbit errors in altimeter height measurements

A mean reference surface and time-dependent orbit errors are estimated simultaneously for each exact-repeat ground track from the first two years of Geosat sea level estimates based on the Goddard Earth model (GEM)-T2 orbits. Motivated by orbit theory and empirical analysis of Geosat data, the time-dependent orbit errors are modeled as 1 cycle per revolution (cpr) sinusoids with slowly varying amplitude and phase. The method recovers the known 'bow tie effect' introduced by the existence of force model errors within the precision orbit determination (POD) procedure used to generate the GEM-T2 orbits. The bow tie pattern of 1-cpr orbit errors is characterized by small amplitudes near the middle and larger amplitudes (up to 160 cm in the 2 yr of data considered here) near the ends of each 5- to 6-day orbit arc over which the POD force model is integrated. A detailed examination of these bow tie patterns reveals the existence of daily modulations of the amplitudes of the 1-cpr sinusoid orbit errors with typical and maximum peak-to-peak ranges of about 14 cm and 30 cm, respectively. The method also identifies a daily variation in the mean orbit error with typical and maximum peak-to-peak ranges of about 6 and 30 cm, respectively, that is unrelated to the predominant 1-cpr orbit error. Application of the simultaneous solution method to the much less accurate Geosat height estimates based on the Naval Astronautics Group orbits concludes that the accuracy of POD is not important for collinear altimetric studies of time-dependent mesoscale variability (wavelengths shorter than 1000 km), as long as the time-dependent orbit errors are dominated by 1-cpr variability and a long-arc (several orbital periods) orbit error estimation scheme such as that presented here is used.

Chelton, Dudley B.↗

Uncertainty of Passive Imager Cloud Optical Property Retrievals to Instrument Radiometry and Model Assumptions: Examples from MODIS

The optical and microphysical structure of clouds is of fundamental importance for understanding a variety of cloud radiation and precipitation processes. With the advent of MODIS on the NASA EOS Terra and Aqua platforms, simultaneous global-daily 1 km retrievals of cloud optical thickness (COT) and effective particle radius (CER) are provided, as well as the derived water path (WP). The cloud product (MOD06/MYD06 for MODIS Terra and Aqua, respectively) provides separate retrieval datasets for various two-channel retrievals, typically a VISNIR channel paired with a 1.6, 2.1, and 3.7 m spectral channel. The MOD06 forward model is derived from on a homogeneous plane-parallel cloud. In Collection 5 processing (completed in 2007 with a modified Collection 5.1 completed in 2010), pixel-level retrieval uncertainties were calculated for the following non-3-D error sources: radiometry, surface spectral albedo, and atmospheric corrections associated with model analysis uncertainties (water vapor only). The latter error source includes error correlation across the retrieval spectral channels. Estimates of uncertainty in 1 aggregated (Level-3) means were also provided assuming unity correlation between error sources for all pixels in a grid for a single day, and zero correlation of error sources from one day to the next. I n Collection 6 (expected to begin in late summer 2013) we expanded the uncertainty analysis to include: (a) scene-dependent calibration uncertainty that depends on new band and detector-specific Level 1B uncertainties, (b) new model error sources derived from the look-up tables which includes sensitivities associated with wind direction over the ocean and uncertainties in liquid water and ice effective variance, (c) thermal emission uncertainties in the 3.7 m band associated with cloud and surface temperatures that are needed to extract reflected solar radiation from the total radiance signal, (d) uncertainty in the solar spectral irradiance at 3.7 m, and (e) addition of stratospheric ozone uncertainty in visible atmospheric corrections. A summary of the approach and example Collection 6 results will be shown.

Cloud Properties Observations↗

Impact of Spectral Resolution on Quantifying Cyanobacteria in Lakes and Reservoirs: A Machine-Learning Assessment

Cyanobacterial harmful algal blooms are an increasing threat to coastal and inland waters. These blooms can be detected using optical radiometers due to the presence of phycocyanin (PC) pigments. The spectral resolution of best-available multispectral sensors limits their ability to diagnostically detect PC in the presence of other photosynthetic pigments. To assess the role of spectral resolution in the determination of PC, a large ( N=905 ) database of colocated in situ radiometric spectra and PC are employed. We first examine the performance of selected widely used machine-learning (ML) models against that of benchmark algorithms for hyperspectral remote sensing reflectance ( R_(rs) ) spectra resampled to the spectral configuration of the Hyperspectral Imager for the Coastal Ocean (HICO) with a full-width at half-maximum (FWHM) of < 6 nm. Results show that the multilayer perceptron (MLP) neural network applied to HICO spectral configurations (median errors < 65%) outperforms other ML models. This model is subsequently applied to R_(rs) spectra resampled to the band configuration of existing satellite instruments and of the one proposed for the next Landsat sensor. These results confirm that employing MLP models to estimate PC from hyperspectral data delivers tangible improvements compared with retrievals from multispectral data and benchmark algorithms (with median errors between ∼73 % and 126%) and shows promise for developing a globally applicable cyanobacteria measurement approach.

hyperspectral↗

Calibration of solar cells by the reference cell method - The spectral mismatch problem

The calibration of solar cells by means of solar simulators and calibrated reference cells has always been faced with the problem of errors due to source spectral irradiance mismatch and cell spectral response mismatch. A general expression is derived in this paper to enable calculation of mismatch error. The information required to make this calculation is the relative spectra responses of the test and reference cells, and the relative spectral irradiance of the simulator (over the spectral range defined by cell response). The spectral irradiance of the solar standard is assumed given. Experimental results are presented.

Seaman, C. H.↗

A robust pseudo-inverse spectral filter applied to the Earth Radiation Budget Experiment (ERBE) scanning channels

Computer simulations of a least squares estimator operating on the ERBE scanning channels are discussed. The estimator is designed to minimize the errors produced by nonideal spectral response to spectrally varying and uncertain radiant input. The three ERBE scanning channels cover a shortwave band a longwave band and a ""total'' band from which the pseudo inverse spectral filter estimates the radiance components in the shortwave band and a longwave band. The radiance estimator draws on instantaneous field of view (IFOV) scene type information supplied by another algorithm of the ERBE software, and on a priori probabilistic models of the responses of the scanning channels to the IFOV scene types for given Sun scene spacecraft geometry. It is found that the pseudoinverse spectral filter is stable, tolerant of errors in scene identification and in channel response modeling, and, in the absence of such errors, yields minimum variance and essentially unbiased radiance estimates.

Avis, L. M.↗

A study of pilot modeling in multi-controller tasks

A modeling approach, which utilizes a matrix of transfer functions to describe the human pilot in multiple input, multiple output control situations, is studied. The approach used was to extend a well established scalar Wiener-Hopf minimization technique to the matrix case and then study, via a series of experiments, the data requirements when only finite record lengths are available. One of these experiments was a two-controller roll tracking experiment designed to force the pilot to use rudder in order to coordinate and reduce the effects of aileron yaw. One model was computed for the case where the signals used to generate the spectral matrix are error and bank angle while another model was computed for the case where error and yaw angle are the inputs. Several anomalies were observed to be present in the experimental data. These are defined by the descriptive terms roll up, break up, and roll down. Due to these algorithm induced anomalies, the frequency band over which reliable estimates of power spectra can be achieved is considerably less than predicted by the sampling theorem.

Whitbeck, R. F.↗

Emissivity correction for interpreting thermal radiation from a terrestrial surface

A general method of accounting for emissivity in making temperature determinations of graybody surfaces from radiometric data is presented. The method differs from previous treatments in that a simple blackbody calibration and graphical approach is used rather than numerical integrations which require detailed knowledge of an instrument's spectral characteristics. Also, errors caused by approximating instrumental response with the Stephan-Boltzman law rather than with an appropriately weighted Planck integral are examined. In the 8-14 micron wavelength interval, it is shown that errors are at most on the order of 3 C for the extremes of the earth's temperature and emissivity. For more practical limits, however, errors are less than 0.5 C.

Sutherland, R. A.↗

A preliminary evaluation of LANDSAT-4 thematic mapper data for their geometric and radiometric accuracies

Some LANDSAT thematic mapper data collected over the eastern United States were analyzed for their whole scene geometric accuracy, band to band registration and radiometric accuracy. Band ratio images were created for a part of one scene in order to assess the capability of mapping geologic units with contrasting spectral properties. Systematic errors were found in the geometric accuracy of whole scenes, part of which were attributable to the film writing device used to record the images to film. Band to band registration showed that bands 1 through 4 were registered to within one pixel. Likewise, bands 5 and 7 also were registered to within one pixel. However, bands 5 and 7 were misregistered with bands 1 through 4 by 1 to 2 pixels. Band 6 was misregistered by 4 pixels to bands 1 through 4. Radiometric analysis indicated two kinds of banding, a modulo-16 stripping and an alternate light dark group of 16 scanlines. A color ratio composite image consisting of TM band ratios 3/4, 5/2, and 5/7 showed limonitic clay rich soils, limonitic clay poor soils, and nonlimonitic materials as distinctly different colors on the image.

Podwysocki, M. H.↗

A Preliminary Evaluation of LANDSAT-4 Thematic Mapper Data for Their Geometric and Radiometric Accuracies

Some LANDSAT thematic mapper data collected over the eastern United States were analyzed for their whole scene geometric accuracy, band to band registration and radiometric accuracy. Band ratio images were created for a part of one scene in order to assess the capability of mapping geologic units with contrasting spectral properties. Systematic errors were found in the geometric accuracy of whole scenes, part of which were attributable to the film writing device used to record the images of film. Band to band registration showed that bands 1 through 4 were registered to within one pixel. Likewise, bands 5 and 7 also were registered to within one pixel. However, bands 5 and 7 were misregistered with bands 1 through 4 by 1 to 2 pixels. Band 6 was misregistered by 4 pixels to bands 1 through 4. Radiometric analysis indicated two kinds of banding, a modulo-16 stripping and an alternate light dark group of 16 scanlines. A color ratio composite image consisting of TM band ratios 3/4, 5/2, and 5/7 showed limonitic clay rich soils, limonitic clay poor soils, and nonlimonitic materials as distinctly different colors on the image.

Podwysocki, M. H.↗

The NBS scale of radiance temperature

The measurement methods and instrumentation used in the realization and transfer of the International Practical Temperature Scale (IPTS-68) above the temperature of freezing gold are described. The determination of the ratios of spectral radiance of tungsten-strip lamps to a gold-point blackbody at a wavelength of 654.6 nm is detailed. The response linearity, spectral responsivity, scattering error, and polarization properties of the instrumentation are described. The analysis of the sources of error and estimates of uncertainty are presented. The assigned uncertainties (three standard deviations) in radiance temperature range from + or - 2 K at 2573 K to + or - 0.5 K at 1073 K.

Waters, William R.↗

High-speed architecture for the decoding of trellis-coded modulation

Since 1971, when the Viterbi Algorithm was introduced as the optimal method of decoding convolutional codes, improvements in circuit technology, especially VLSI, have steadily increased its speed and practicality. Trellis-Coded Modulation (TCM) combines convolutional coding with higher level modulation (non-binary source alphabet) to provide forward error correction and spectral efficiency. For binary codes, the current stare-of-the-art is a 64-state Viterbi decoder on a single CMOS chip, operating at a data rate of 25 Mbps. Recently, there has been an interest in increasing the speed of the Viterbi Algorithm by improving the decoder architecture, or by reducing the algorithm itself. Designs employing new architectural techniques are now in existence, however these techniques are currently applied to simpler binary codes, not to TCM. The purpose of this report is to discuss TCM architectural considerations in general, and to present the design, at the logic gate level, or a specific TCM decoder which applies these considerations to achieve high-speed decoding.

Osborne, William P.↗

High-spatial-resolution passive microwave sounding systems

The principal contributions of this combined theoretical and experimental effort were to advance and demonstrate new and more accurate techniques for sounding atmospheric temperature, humidity, and precipitation profiles at millimeter wavelengths, and to improve the scientific basis for such soundings. Some of these techniques are being incorporated in both research and operational systems. Specific results include: (1) development of the MIT Microwave Temperature Sounder (MTS), a 118-GHz eight-channel imaging spectrometer plus a switched-frequency spectrometer near 53 GHz, for use on the NASA ER-2 high-altitude aircraft, (2) conduct of ER-2 MTS missions in multiple seasons and locations in combination with other instruments, mapping with unprecedented approximately 2-km lateral resolution atmospheric temperature and precipitation profiles, atmospheric transmittances (at both zenith and nadir), frontal systems, and hurricanes, (3) ground based 118-GHz 3-D spectral images of wavelike structure within clouds passing overhead, (4) development and analysis of approaches to ground- and space-based 5-mm wavelength sounding of the upper stratosphere and mesosphere, which supported the planning of improvements to operational weather satellites, (5) development of improved multidimensional and adaptive retrieval methods for atmospheric temperature and humidity profiles, (6) development of combined nonlinear and statistical retrieval techniques for 183-GHz humidity profile retrievals, (7) development of nonlinear statistical retrieval techniques for precipitation cell-top altitudes, and (8) numerical analyses of the impact of remote sensing data on the accuracy of numerical weather predictions; a 68-km gridded model was used to study the spectral properties of error growth.

Staelin, D. H.↗

Thematic mapper radiomtric variability on ostensibly uniform agricultural scenes

The effects of the interaction of the sensor point spread function with a heterogeneous scene consisting of elements giving rise to different spectral radiant intensities cause errors in multitemporal signatures due to fractional pixel repositioning errors. In the case of a heterogeneous scene, the repositioning accuracy between acquisitions could affect the radiometric output in any band and could affect the spectral distribution of radiance between bands. Error caused by within-band and between-band variations in radiance with time could be compounded by resampling along and between scan lines during processing. The magnitude of both error sources depends on the degree of heterogeneity of the scene.

Duggin, M. J.↗

Proposed Recommendation for DDOR PN Spread Spectrum Systems

Currently, instrumental phase dispersion is a large error term in the Delta-Differential One-way Ranging (DDOR) error budget. This error arises from the spectral difference between the narrowband spacecraft signal and the broadband quasar signal. This error term can be reduced in modern transponders by implementing a pseudo-noise (PN) spread spectrum DOR signal instead of the classic sinusoidal DOR signal. To standardize PN DDOR cross-support, this paper proposes the definitions and specifications required to support a PN DDOR system. The motivation for PN DDOR is first presented. Then, informational background is presented on code selection, pulse shaping, and code parameters. Finally, Appendix A presents a new proposed Recommendation 2.5.7B for Spread Spectrum DDOR, to be included in CCSDS 401.

Volk, Christopher P↗

X-ray observations of BL Lacertae objects

Results are reported for OSO 8 and HEAO 1 X-ray observations of the BL Lac objects Mrk 421, Mrk 501, and PKS 0548-322 over the energy range from 2 to 60 keV. It is found that the X-ray spectra of Mrk 421 and 501 are similar, exhibit statistically significant soft X-ray excesses, lack low-energy absorption, and are best fitted by power laws over the 2-30-keV range with respective photon indices of approximately 0.91 and 1.2 and respective hydrogen column densities of less than 8 x 10 to the 21st per sq cm and no more than 1.8 x 10 to the 22nd per sq cm. It is noted that the spectral index for both sources is identical, within errors, to the HF radio spectral index and that Mrk 421 experienced a factor of 6 decrease in the 2-10-keV band over a six-month period. A tentative identification of PKS 0548-322 with the source H0548-32 is suggested.

Mushotzky, R. F.↗

Effect of radiometric errors on accuracy of temperature-profile measurement by spectral scanning using absorption-emission pyrometry

The spectral-scanning method may be used to determine the temperature profile of a jet- or rocket-engine exhaust stream by measurements of gas radiation and transmittance, at two or more wavelengths. A single, fixed line of sight is used, using immobile radiators outside of the gas stream, and there is no interference with the flow. At least two sets of measurements are made, each set consisting of the conventional three radiometric measurements of absorption-emission pyrometry, but each set is taken over a different spectral interval that gives different weight to the radiation from a different portion of the optical path. Thereby, discrimination is obtained with respect to location along the path. A given radiometric error causes an error in computed temperatures. The ratio between temperature error and radiometric error depends on profile shape, path length, temperature level, and strength of line absorption, and the absorption coefficient and its temperature dependency. These influence the choice of wavelengths, for any given gas. Conditions for minimum temperature error are derived. Numerical results are presented for a two-wavelength measurement on a family of profiles that may be expected in a practical case of hydrogen-oxygen combustion. Under favorable conditions, the fractional error in temperature approximates the fractional error in radiant-flux measurement.

Buchele, D. R.↗