Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral filter design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An airborne far-infrared spectrometer for astronomical observations

A Fabry-Perot spectrometer for airborne observations of astronomical spectral lines has been designed for use in the 50 to 200 micron region of the far-infrared. The spectrometer uses a fixed wavelength Fabry-Perot filter cooled to 4.2 K in conjunction with a high order scanning Fabry-Perot at room temperature. This arrangement provides high spectral resolution and also minimizes the thermal background radiation on the detector. The instrument has been successfully used to study all the presently detected fine structure lines between 50 and 120 microns.

Storey, J. W. V.↗

Visible and shortwave infrared focal planes for remote sensing instruments

The development of solid-state sensor technology for multispectral linear array (MLA) instruments is described. A buttable four-spectral-band linear-format CCD and a buttable two-spectral band linear-format short-wave IR CCD have been designed, and first samples have been demonstrated. In addition, first-sample four-band interference filters have been fabricated, and hybrid packaging technology is being developed. Based on this development work, the design and construction of focal planes for a Shuttle sortie MLA instrument have begun. This work involves a visible and near-IR focal plane with 2048 pixels x 4 spectral bands and a short-wave IR focal plane with 1024 pixels x 2 spectral bands.

Tower, J. R.↗

Development of a Compact Imaging Spectrometer Using Liquid Crystal Tunable Filter Technology

Liquid crystal tunable filters are useful in building compact multi-spectral instruments. The system is portable and adaptable for use in a variety of fields of study in the visible and near-infrared regions of the spectrum.We will present data from calibration targets and some applications, results of the spectral calibration of a spectrometer system, and results of environmental (vibration, radiation, shock, and thermal) testing. Data acquisition and system design are also discussed.

spectrometers imaging↗

Acousto-optic tunable filter field spectrometer for validation of airborne and spaceborne imaging spectrometers

A new concept for a field portable spectrometer designed to meet the needs of the remote sensing community is presented. This instrument uses acoustooptic tunable filters (AOTFs) as wavelength sorters, allowing the design of a rugged, compact, light-weight tool that provides broad spectral coverage, great versatility, and ease of utilization. The spectrometer provides continuous spectral coverage from 0.4 to 2.5 microns with two channels defined by detector technology, while a visible channel covering the 0.4 to 1.0 micron spectral range uses silicon PV photodiodes. The short-wavelength IR channel covers the 0.9 to 2.5 micron special range with thermoelectrically cooled lead sulfide PC detectors.

Rider, David M.↗

Tunable Optical Filters for Space Exploration

Spectrally tunable liquid crystal filters provide numerous advantages and several challenges in space applications. We discuss the tradeoffs in design elements for tunable liquid crystal birefringent filters with special consideration required for space exploration applications. In this paper we present a summary of our development of tunable filters for NASA space exploration. In particular we discuss the application of tunable liquid crystals in guidance navigation and control in space exploration programs. We present a summary of design considerations for improving speed, field of view, transmission of liquid crystal tunable filters for space exploration. In conclusion, the current state of the art of several NASA LaRC assembled filters is presented and their performance compared to the predicted spectra using our PolarTools modeling software.

Crandall, Charles↗

An astronomy camera for low background applications in the 1.0 to 2.5 micron spectral region

A description is given of a low-background astronomy camera system based on a short wavelength (1.0-2.5 micron) 128 x 128 focal plane array. The camera is designed to accept either a HgCdTe array for the 1-2.5 micron spectral region or an InSb array for the 3-5 micron spectral region. A cryogenic folded optical system is utilized to control excess stray light along with a cold eight-position filter wheel for spectral filtering. The camera head and electronics will also accept a 256 x 256 focal plane. Engineering evaluation of the system and two engineering runs at the JPL Table Mountain Observatory have been completed. System design, engineering performance, and sample imagery are presented.

Kaki, Said A.↗

Infrared focal plane design for the Comet Rendezvous/Asteroid Flyby and Cassini Visible and Infrared Mapping Spectrometers

A focal plane assembly combining hybrid electronic components with passive optical components within a single hermetically sealed package has been designed by Cincinnati Electronics to meet the performance requirements imposed by the Comet Rendezvous/Asteroid Flyby (CRAF) and Cassini Visible and Infrared Mapping Spectrometers (VIMSs). A single line array of 256 InSb photodiodes, accessed by two 1 x 128 multiplexers, provides continuous spectral coverage from 0.85 to 5.1 microns. Intrinsic field-of-view apertures and a unique order sorting filter require critical optical alignment within the hybrid. FPA performance requirements, design approach, and critical issues are discussed.

Staller, Craig↗

Design and performance characteristics of the Vertical Temperature Profile Radiometer /VTPR/ for atmospheric temperature soundings.

Description of the design and operation of a radiometer which derives atmospheric temperature profiles on the basis of spectral measurements in eight optical filter channels. The radiometer achieves its eight-channel capability by sequentially viewing the eight optical filters mounted in a rotating filter wheel, with a single IR detector and electronic amplification channel processing the signal for all the filters. The advantages and disadvantages of this sequential approach as compared to eight 'parallel' radiometric channels are discussed. The proposed radiometer provides a relative calibration accuracy between seven out of the eight channels of better than 0.1% rms of the full dynamic range. The absolute accuracy achievable between in-flight calibrations of six minutes, or between two-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the in-flight calibration source of the instrument and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

On-Orbit Performance of MODIS Solar Diffuser Stability Monitor

Moderate Resolution Imaging Spectroradiometer (MODIS) is currently operated on both the Terra and Aqua spacecraft. It collects data in 20 reflective solar bands (RSB) and 16 thermal emissive bands. MODIS RSB calibration is reflectance based via an on-board solar diffuser (SD). On-orbit changes in the SD bidirectional reflectance factor are tracked by an onboard solar diffuser stability monitor (SDSM). The SDSM functions as an independent ratioing radiometer with nine filtered detectors, covering wavelengths in the visible (VIS) and near-infrared (NIR) spectral regions. A brief overview of SDSM design functions, on-orbit operations, and performance for both Terra and Aqua MODIS is provided. In addition to the SD on-orbit degradation at different wavelengths, the changes in SDSM detector responses and their potential impact on tracking SD on-orbit degradation are examined. After more than 12 years of on-orbit operation, Aqua MODIS SD has shown degradation varying from 0.6% at 0.94 microns to 19.0% at 0.41 microns. Due to more frequent solar exposure and longer operation time, the Terra MODIS SD has experienced a much larger degradation, varying from 2.3% at 0.94 microns to 48.0% at 0.41 microns. For both Terra and Aqua MODIS, the SD has experienced more degradation at shorter wavelengths. Meanwhile, the SDSM detector responses have also experienced wavelength-dependent degradation. The largest change in the SDSM detector responses, however, occurred at longer NIR wavelengths. Since launch, the SDSM systems on both Terra and Aqua MODIS have continued their nominal operations, enabling critical parameters to be derived in support of the RSB on-orbit calibration. The calibration strategies developed for and lessons learned from MODIS SDSM operations, and a preliminary performance comparison with the S-NPP VIIRS SDSM are discussed.

MODIS↗

The ultraviolet imager (UVI) for ISTP

We report the design of an imager with 0.6-millirad angular resolution over an 8-deg field of view sampled with 39,500 pixels, yielding global auroral coherent imaging from above 6 R(E). High performance filters provide spectrally pure measurements of four key FUV features, with 10 exp -4 out-of-band rejection. Together with the solar blind intensified CCD detector, a net rejection of 10 exp -9 of all out-of-band emissions is achieved. The optical design comprises a three-mirror f/3 system which yields a noise equivalent sensitivity of 10 Rayleighs for a 37-sec frame rate. The instantaneous dynamic range is 1000 which can be windowed over a range of 10 exp 4.

Torr, D. G.↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Johnson, B. Carol↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Hooker, Stanford B.↗

A Compact, Multi-view Net Flux Radiometer for Future Uranus and Neptune Probes

A Net Flux Radiometer (NFR) is presented that can be included in an atmospheric structure instrument suite for future probe missions to the icy giants Uranus and Neptune. The baseline design has two spectral channels i.e., a solar channel (0.4-to-3.5 m) and a thermal channel (4-to-300 m). The NFR is capable of viewing five distinct viewing angles during the descent. Non-imaging Winston cones with band-pass filters are used for each spectral channel and to define a 5 angular acceptance. Uncooled thermopile detectors are used in each spectral channel and are read out using a custom radiation hard application specific integrated circuit (ASIC). The baseline design can easily be changed to increase the number of detector channels from two to seven.

Aslam, S.↗

Cryogenic refractor design techniques

The Infrared Astronomical Satellite (IRAS) was designed to operate at 2K, and over the spectral range of 8 to 120 micrometers. The focal plane is approximately 2 by 3 inches in size, and contains 62 individual field stop apertures, each with its own field lens, one or more filters and a detector. The design of the lenses involved a number of difficulties and challenges that are not usually encountered in optical design. Operating temperature is assumed during the design phase, which requires reliable information on dN/dT (Index Coefficient) for the materials. The optics and all supporting structures are then expanded to room temperature, which requires expansion coefficient data on the various materials, and meticulous attention to detail. The small size and dense packaging, as well as the high precision required, further contributed to the magnitude of the task.

Darnell, R. J.↗

An optimal control approach to the design of moving flight simulators

An abstract flight simulator design problem is formulated in the form of an optimal control problem, which is solved for the linear-quadratic-Gaussian special case using a mathematical model of the vestibular organs. The optimization criterion used is the mean-square difference between the physiological outputs of the vestibular organs of the pilot in the aircraft and the pilot in the simulator. The dynamical equations are linearized, and the output signal is modeled as a random process with rational power spectral density. The method described yields the optimal structure of the simulator's motion generator, or 'washout filter'. A two-degree-of-freedom flight simulator design, including single output simulations, is presented.

Sivan, R.↗

Trends in measurement of solar vector magnetic fields using the Zeeman effect

Trends in spectropolarimetry as applied to the problem of Zeeman effect measurement are discussed. The use of detector arrays to improve observing efficiency is obtained. Which required new polarization modulation schemes that match the time required to read detector arrays. Another significant trend is narrowband filters, to improve angular and temporal coverage, and to Fourier transform spectrometers, to improve spectral coverage and precision. Low-polarization designs and improved methods for compensating instrumental polarization were developed. A requirement for high angular resolution suggests using adaptive optical devices to subdue the effects of bad seeing. The ultimate strategy to beat the seeing is to loft the telescope above the atmosphere such as is planned with a 30-cm telescope in 1985 and a 1250-cm telescope in 1990.

Harvey, J. W.↗

Enhanced Aluminum Reflecting and Solar-Blind Filter Coatings for the Far-Ultraviolet

The advancement of far-ultraviolet (FUV) coatings is essential to meet the specified throughput requirements of the Large UV/Optical/IR (LUVOIR) Surveyor Observatory which will cover wavelengths down to the 100 nm range. The biggest constraint in the optical thin film coating design is attenuation in the Lyman-Alpha Ultraviolet range of 100-130 nm in which conventionally deposited thin film materials used in this spectral region (e.g. aluminum [Al] protected with Magnesium fluoride [MgF2]) often have high absorption and scatter properties degrading the throughput in an optical system. We investigate the use of optimally deposited aluminum and aluminum tri-fluoride (AlF3) materials for reflecting and solar blind band-pass filter coatings for use in the FUV. Optical characterization of the deposited designs has been performed using UV spectrometry. The optical thin film design and optimal deposition conditions to produce superior reflectance and transmittance using Al and AlF3 are presented.

optical thin films↗

Global tropospheric and total ozone monitoring with a Double-Etalon Fabry-Perot interferometer

Knowledge of the global scale distribution of atmospheric ozone and its temporal variability can be achieved using a satellite-based nadir-viewing device making high spectral resolution measurements with high signal-to-noise ratios. This would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface and interfering species. The Fabry-Perot interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. The periodic nature of the Fabry-Perot instrument function can be advantageous when observation of periodic spectra is desired. However, for most applications, additional optical elements are necessary to reduce the effect of unwanted passbands. This is frequently accomplished using additional Fabry-Perot etalons in a series configuration in conjunction with a bandpass filter. This paper discusses a Fabry-Perot interferometer conceptual instrument design to achieve tropospheric and total ozone monitoring capability from a satellite-based nadir-viewing geometry. The design involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). The impact of inter-etalon reflections has been reduced to acceptable levels by placement of a slightly attenuating medium in between the etalons. A passive device is selected for low power consumption, and continuous day/night coverage, independent of solar zenith angle, is enabled by observing within the strong 9.6 micron ozone infrared band. The IR-FPI detection will be performed through implementation of the new Circle to Line Interferometer Optical (CLIO) system, developed by researchers at the Space Physics Research Laboratory (SPRL) of the University of Michigan, to accomplish focal plane fringe detection; the CLIO system converts the circular interferometric fringes into a linear pattern which then can be detected by conventional linear array detectors. A multiplex signal advantage is achievable as all necessary frequencies can be measured simultaneously using a multichannel configuration. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance.

Larar, Allen M.↗