Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of a Computer Architecture to Support the Optical Plume Anomaly Detection (OPAD) System

The NASA OPAD spectrometer system relies heavily on extensive software which repetitively extracts spectral information from the engine plume and reports the amounts of metals which are present in the plume. The development of this software is at a sufficiently advanced stage where it can be used in actual engine tests to provide valuable data on engine operation and health. This activity will continue and, in addition, the OPAD system is planned to be used in flight aboard space vehicles. The two implementations, test-stand and in-flight, may have some differing requirements. For example, the data stored during a test-stand experiment are much more extensive than in the in-flight case. In both cases though, the majority of the requirements are similar. New data from the spectrograph is generated at a rate of once every 0.5 sec or faster. All processing must be completed within this period of time to maintain real-time performance. Every 0.5 sec, the OPAD system must report the amounts of specific metals within the engine plume, given the spectral data. At present, the software in the OPAD system performs this function by solving the inverse problem. It uses powerful physics-based computational models (the SPECTRA code), which receive amounts of metals as inputs to produce the spectral data that would have been observed, had the same metal amounts been present in the engine plume. During the experiment, for every spectrum that is observed, an initial approximation is performed using neural networks to establish an initial metal composition which approximates as accurately as possible the real one. Then, using optimization techniques, the SPECTRA code is repetitively used to produce a fit to the data, by adjusting the metal input amounts until the produced spectrum matches the observed one to within a given level of tolerance. This iterative solution to the original problem of determining the metal composition in the plume requires a relatively long period of time to execute the software in a modern single-processor workstation, and therefore real-time operation is currently not possible. A different number of iterations may be required to perform spectral data fitting per spectral sample. Yet, the OPAD system must be designed to maintain real-time performance in all cases. Although faster single-processor workstations are available for execution of the fitting and SPECTRA software, this option is unattractive due to the excessive cost associated with very fast workstations and also due to the fact that such hardware is not easily expandable to accommodate future versions of the software which may require more processing power. Initial research has already demonstrated that the OPAD software can take advantage of a parallel computer architecture to achieve the necessary speedup. Current work has improved the software by converting it into a form which is easily parallelizable. Timing experiments have been performed to establish the computational complexity and execution speed of major components of the software. This work provides the foundation of future work which will create a fully parallel version of the software executing in a shared-memory multiprocessor system.

Katsinis, Constantine↗

Distortion Representation of Forecast Errors for Model Skill Assessment and Objective Analysis

We completed the formulation of the smoothness penalty functional this past quarter. We used a simplified procedure for estimating the statistics of the FCA solution spectral coefficients from the results of the unconstrained, low-truncation FCA (stopping criterion) solutions. During the current reporting period we have completed the calculation of GEOS-2 model-equivalent brightness temperatures for the 6.7 micron and 11 micron window channels used in the GOES imagery for all 10 cases from August 1999. These were simulated using the AER-developed Optimal Spectral Sampling (OSS) model.

Hoffman, Ross N.↗

Near-infrared detection of potential evidence for microscopic organisms on Europa

The possibility of an ocean within the icy shell of Jupiter's moon Europa has established that world as a primary candidate in the search for extraterrestrial life within our Solar System. This paper evaluates the potential to detect evidence for microbial life by comparing laboratory studies of terrestrial microorganisms with measurements from the Galileo Near Infrared Imaging Spectrometer (NIMS). If the interior of Europa at one time harbored life, some evidence may remain in the surface materials. Examination of laboratory spectra of terrestrial extremophiles measured at cryogenic temperatures reveals distorted, asymmetric nearinfrared absorption features due to water of hydration. The band centers, widths, and shapes of these features closely match those observed in the Europa spectra. These features are strongest in reddish-brown, disrupted terrains such as linea and chaos regions. Narrow spectral features due to amide bonds in the microbe proteins provide a means of constraining the abundances of such materials using the NIMS data. The NIMS data of disrupted terrains exhibit distorted, asymmetric near-infrared absorption features consistent with the presence of water ice, sulfuric acid octahydrate, hydrated salts, and possibly as much as 0.2 mg cm(-3) of carbonaceous material that could be of biological origin. However, inherent noise in the observations and limitations of spectral sampling must be taken into account when discussing these findings.

Extraterrestrial Environment↗

Lunar and Planetary Science XXXVI, Part 5

Topics discussed include: Automation Recognition oF Crater-Like Structures in Terrestrial and Plantary Images; Condensation from Cluster-IDP Enriched Vapor Inside the Snow Line: Implications for Mercury, Asteroids, and Enstatite Chondrites; Tomographic Location of Potential Melt-Bearing Phenocrysts in Lunar Glass Spherules; Source and Evolution of Vapor Due to Impacts into Layered Carbonates and Silicates; Noble Gases and I-Xe Ages of the Zag Meteorite; The MArs Hand Lens Imager (MAHLI) for the 209 Mars Science Laboratory; The Sedimentary Rocks of Meridiani Planum, in Context; Three-System Isotopic of Lunar Norite 78238: Rb-Sr Results; Constraints on the Role of Curium-247 as a Source of Fission Xenon in the Early Solar System; New Features in the ADS Abstract Service; Cassini RADAR's First Look at Titan; Volcanism and Volatile Recycling on Venus from Lithospheric Delamination; The Fate of Water in the Martian Magma Ocean and the Formation of an Early Atmosphere; Mars Odyssey Neutron Spectrometer Water-Equivalent Hydrogen: Comparison with Glacial; Landforms on Tharsis; Using Models of Permanent Shadow to Constrain Lunar Polar Water Ice Abundances; Martian Radiative Transfer Modeling Using the Optimal Spectral Sampling Method; Petrological and Geochemical Consideration on the Tuserkanite Meteorite; and Mineralogy of Asteroids from Observations with the Spitzer Space Telescope.

Source record↗

Recent Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS)

Several improvements have been made to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS) since 1994--new focal plane arrays, a new analog and digital chain and an onboard calibration lamp controlled by radiance feedback. These changes increased the signal-to- noise ratio by 2 to 3 times, eliminated noise spikes and the need for spectral sampling, and greatly reduced dark-current noise.

AVRIS improvements spectrometer↗

Flora: A Proposed Hyperspectral Mission

In early 2004, one of the authors (Stephen Ungar, NASA GSFC) presented a mission concept called "Spectrasat" at the AVIRIS Workshop in Pasadena, CA. This mission concept grew out of the lessons learned from the Earth Observing-One (EO-1) Hyperion Imaging Spectrometer and was structured to more effectively accomplish the types of studies conducted with Hyperion. The Spectrasat concept represented an evolution of the technologies and operation strategies employed on EO-I. The Spectrasat concept had been preceded by two community-based missions proposed by Susan Ustin, UC Davis and Robert Green, NASA JPL. As a result of community participation, starting at this AVIRIS Workshop, the Spectrasat proposal evolved into the Flora concept which now represents the combined visions of Gregory Asner (Carnegie Institute), Stephen Ungar, Robert Green and Robert Knox, NASA GSFC. Flora is a proposed imaging spectrometer mission, designed to address global carbon cycle science issues. This mission centers on measuring ecological disturbance for purposes of ascertaining changes in global carbon stocks and draws heavily on experience gained through AVIRIS airborne flights and Hyperion space born flights. The observing strategy exploits the improved ability of imaging spectrometers, as compared with multi-spectral observing systems, to identify vegetation functional groups, detect ecosystem response to disturbance and assess the related discovery. Flora will be placed in a sun synchronous orbit, with a 45 meter pixel size, a 90 km swath width and a 31 day repeat cycle. It covers the spectral range from 0.4 to 2.5 micrometers with a spectral sampling interval of 10 nm. These specifications meet the needs of the Flora science team under the leadership of Gregory Asner. Robert Green, has introduced a spectrometer design for Flora which is expected to have a SNR of 600: 1 in the VNIR and 450: 1 in the SWIR. The mission team at NASA GSFC is designing an Intelligent Payload Module (IPM) designed to effectively reduce the volume of data required to be transmitted down to the ground. This paper discusses mission science objectives, describes the mission concept and presents the current status of possible funding opportunities leading to realization of the mission.

Ungar, Stephen↗

Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration

The most accurate astronomical data is available from space-based observations that are not impeded by the Earth's atmosphere. Such measurements may require spectral samples taken as long as decades apart, with the 1 cm/s velocity precision integrated over a broad wavelength range. This raises the requirements specifically for instruments used in astrophysics research missions -- their stringent wavelength resolution and accuracy must be maintained over years and possibly decades. Therefore, a stable and broadband optical calibration technique compatible with spaceflights becomes essential. The space-based spectroscopic instruments need to be calibrated in situ, which puts forth specific requirements to the calibration sources, mainly concerned with their mass, power consumption, and reliability. A high-precision, high-resolution reference wavelength comb source for astronomical and astrophysics spectroscopic observations has been developed that is deployable in space. The optical comb will be used for wavelength calibrations of spectrographs and will enable Doppler measurements to better than 10 cm/s precision, one hundred times better than the current state-of-the- art.

Strekalov, Dmitry V.↗

Assessment of Mars Atmospheric Temperature Retrievals from the Thermal Emission Spectrometer Radiances

Motivated by the needs of Mars data assimilation. particularly quantification of measurement errors and generation of averaging kernels. we have evaluated atmospheric temperature retrievals from Mars Global Surveyor (MGS) Thermal Emission Spectrometer (TES) radiances. Multiple sets of retrievals have been considered in this study; (1) retrievals available from the Planetary Data System (PDS), (2) retrievals based on variants of the retrieval algorithm used to generate the PDS retrievals, and (3) retrievals produced using the Mars 1-Dimensional Retrieval (M1R) algorithm based on the Optimal Spectral Sampling (OSS ) forward model. The retrieved temperature profiles are compared to the MGS Radio Science (RS) temperature profiles. For the samples tested, the M1R temperature profiles can be made to agree within 2 K with the RS temperature profiles, but only after tuning the prior and error statistics. Use of a global prior that does not take into account the seasonal dependence leads errors of up 6 K. In polar samples. errors relative to the RS temperature profiles are even larger. In these samples, the PDS temperature profiles also exhibit a poor fit with RS temperatures. This fit is worse than reported in previous studies, indicating that the lack of fit is due to a bias correction to TES radiances implemented after 2004. To explain the differences between the PDS and Ml R temperatures, the algorithms are compared directly, with the OSS forward model inserted into the PDS algorithm. Factors such as the filtering parameter, the use of linear versus nonlinear constrained inversion, and the choice of the forward model, are found to contribute heavily to the differences in the temperature profiles retrieved in the polar regions, resulting in uncertainties of up to 6 K. Even outside the poles, changes in the a priori statistics result in different profile shapes which all fit the radiances within the specified error. The importance of the a priori statistics prevents reliable global retrievals based a single a priori and strongly implies that a robust science analysis must instead rely on retrievals employing localized a priori information, for example from an ensemble based data assimilation system such as the Local Ensemble Transform Kalman Filter (LETKF).

Hoffman, Matthew J.↗

Cris-atms Retrievals Using an AIRS Science Team Version 6-like Retrieval Algorithm

CrIS is the infrared high spectral resolution atmospheric sounder launched on Suomi-NPP in 2011. CrISATMS comprise the IRMW Sounding Suite on Suomi-NPP. CrIS is functionally equivalent to AIRS, the high spectral resolution IR sounder launched on EOS Aqua in 2002 and ATMS is functionally equivalent to AMSU on EOS Aqua. CrIS is an interferometer and AIRS is a grating spectrometer. Spectral coverage, spectral resolution, and channel noise of CrIS is similar to AIRS. CrIS spectral sampling is roughly twice as coarse as AIRSAIRS has 2378 channels between 650 cm-1 and 2665 cm-1. CrIS has 1305 channels between 650 cm-1 and 2550 cm-1. Spatial resolution of CrIS is comparable to AIRS.

AIRS↗

Hyperspectral Radiative Transfer Modeling to Explore the Combined Retrieval of Biophysical Parameters and Canopy Fluorescence from FLEX - Sentinel-3 Tandem Mission Multi-Sensor Data

The FLuorescence EXplorer (FLEX) satellite mission, selected as ESA's 8th Earth Explorer, has been designed forthe measurement of sun-induced fluorescence (F) spectra emitted by plants. This will be accomplished through amulti-sensor approach by placing it in a common orbit in tandem with the Sentinel-3 (S3) mission, which willhave two optical sensors on board, OLCI (Ocean and Land Colour Instrument) and SLSTR (Sea and Land SurfaceTemperature Radiometer) to complement FLEX. These S3 instruments will be used in combination with theimaging spectrometers on board FLEX to provide data useful for atmospheric correction of FLEX data. However,a fully synergetic approach, i.e. by exploiting the spectral and directional information from all tandem missioninstruments together, is an attractive alternative which is explored in this paper. By employing all combined topof-atmosphere (TOA) spectral radiance data, one can (i) characterize the relevant optical properties of the atmosphere,(ii) retrieve biophysical canopy properties including the associated reflectance anisotropy, and (iii)retrieve a more accurate and consistent canopy F.Regarding retrieval methods, Fraunhofer Line Depth (FLD) and Spectral Fitting (SF) are well-known techniquesapplied to hyperspectral data. Both methods depend on a high spectral resolution and assume aLambertian (isotropic) canopy reflectance. However, most vegetation canopies are non-Lambertian. This impliesthat, in particular when ignoring the anisotropic surface reflection, substantial retrieval errors can occur due tothe interaction between atmospheric absorption bands and surface reflectance anisotropy. In this paper, a novelmethod based on spectral radiative transfer (RT) modeling is proposed, in which coupled RT models are used tosimulate TOA radiance spectra. These are then matched with ‘measured' spectra in order to retrieve surfacefluorescence, along with a suite of biophysical parameters, by model inversion through optimization. By applyingcoupled RT models of the soil-leaf-canopy and the surface-atmosphere systems, TOA radiance spectra canbe simulated for all optical sensors of this tandem mission. In this way, complex effects due to surface reflectanceanisotropy and the spectral sampling by the various instruments, which are difficult to compensate for in the endproducts, are properly taken into account by their incorporation in the forward modeling. Next, by model inversionof TOA radiance data via optimization, the most accurate F retrievals can be achieved in a consistentmanner, along with important canopy level biophysical parameters that may help interpret the F spectrum, suchas chlorophyll content and leaf area index (LAI). The potential of this approach has been explored in a numericalexperiment, and the results are presented in this paper. We find that, with the assumed well-characterized andplausible FLEX/S3 instrument performances, the simultaneous retrieval of biophysical canopy parameters and Fspectra would be possible with a remarkable accuracy, provided the correct atmospheric characterization isavailable.

Verhoef, Wouter↗

Differences Between OCO‐2 and GOME‐2 SIF Products From a Model‐Data Fusion Perspective

Space-borne retrievals of solar-induced chlorophyll fluorescence (SIF) over land surfaces have recently become a resource for studying and quantifying the broad scale dynamics of gross carbon uptake (gross primary productivity—GPP) across ecosystems. To prepare for the assimilation of SIF data in terrestrial biosphere models, we examine how differences between SIF products (due to differences in acquisition characteristics and processing chain) may affect the optimization of model parameters and the resultant GPP estimate. We compare recent daily mean SIF products (one from the Orbiting Carbon Observatory-2 [OCO-2] and two from the Global Ozone Monitoring Experiment–2 [GOME-2], GlobFluo [GF] and NASA-v28 [N28], missions), averaged at 0.5° × 0.5° spatial resolution and 16-day temporal resolution, at the biome level. Phase differences between these products are relatively small. A first-order correction of the difference in spectral sampling between the two instruments shows that OCO-2 and N28 are consistent in terms of magnitude and amplitude, while GF is twice as large as the others. Using a bias-blind toy data assimilation framework, we analyze how biases between SIF products, and between model and products, can be partially alleviated by optimizing the slope and intercept parameters of a linear GPP-SIF operator. As observation biases can transfer to biases in other optimized process-based parameters and to modeled carbon fluxes— thereby resulting in unidentified inaccurate parameter values—we argue that potential SIF biases should be treated cautiously in real-world experiments in order to achieve realistic and reliable future simulations.

Gross primary production↗

Optical design of the Mapping Imaging Spectrometer for Europa (MISE)

e Mapping Imaging Spectrometer for Europa (MISE) is a high-throughput pushbroom imaging spectrometer designed for NASA’s planned flyby mission to Jupiter’s moon Europa. The MISE design utilizes heritage from previously demonstrated instruments on airborne platforms, while advancing the state of the art to operate within Europa’s challenging environment. The instrument operates at F/1.4 and covers a spectral range from 0.8 to 5 microns with 10 nm spectral sampling. Through high resolution mapping, MISE is designed to identify distributions of organics, salts, acid hydrates, water ice phases, altered silicates, radiolytic compounds, and warm thermal anomalies at global, regional, and local scales. Such distribution maps will help study surface and subsurface geologic processes, and assess the habitability of Europa’s ocean. We discuss the optical specifications and baseline performance of the MISE optical design.

Van Gorp, Byron E.↗

A Deep Learning Approach to Fast Radiative Transfer

Due to the sheer volume of data, leveraging satellite instrument observations effectively in a data assimilation context for numerical weather prediction or for remote sensing requires a radiative transfer model as an observation operator that is both fast and accurate at the same time. Physics-based line-by-line radiative transfer (RT) models fulfil the requirement for accuracy, but are too slow and too costly in computational terms for operational applications. Therefore, fast methods were developed to be able to perform fast RT calculations using techniques such as spectral sampling or pre-computed look-up tables. The operational fast models currently calculate the absorption and scattering coefficients from the pre-computed regression coefficients and atmospheric state and cloud profiles. As a novel solution to this problem, this work investigates a deep learning approach to replace the regression coefficients in the fast RT models. A selection of hidden-layer neural network configurations is trained against atmospheric transmittance profile data computed by an accurate line-by-line model and their performance is evaluated and their advantages and disadvantages are discussed.

Machine learning↗

Optical Design of the Earth Surface Mineral Dust Source Investigation (EMIT) Imaging Spectrometer

The Earth Surface Mineral Dust Source Investigation (EMIT) instrument is a high fidelity imaging spectrometer developed to characterize surface mineralogy of the Earth’s dust source regions over the spectral range of 380- 2500 nm and spectral sampling of 7.4 nm. EMIT will close the current knowledge gap in dust source mineral composition by collecting over 1 billion high signal-to-noise ratio spectra in this region of our planet. These new measurements will be used in conjunction with state-of-the-art Earth System Models to understand and reduce the uncertainty in the radiative forcing effect of mineral dust aerosols. EMIT will be deployed on the International Space Station that has an orbit that is well suited for measuring the arid land regions of the Earth. The optical design utilizes a Dyson spectrometer to reduce volume and mass for a fast (F/1.8) and wide swath (1240 samples) optical system. An overview of the EMIT optical design, development, and current status are discussed.

Green, Robert O.↗

Manufacturing, Characterization and Terrestrial Passive Radiative Cooling Performance of Nanofibrous PTFR-PEO Composite Thermal Coatings

Passive heat management is desirable in many applications since it can reduce the energy expended for cooling, for example, in buildings and automobiles. Specifically, materials with wavelength-dependent reflectance and emittance can manage incident solar fluxes while enabling passive radiative cooling by thermal emission. This study demonstrates the use of polymeric nanofibers, specifically polytetrafluoroethylene (PTFE) and polyethylene oxide (PEO) composite, as thermal coatings for passive temperature control. Employing the electrospinning fabrication process, we engineer nano and micro-scale fibrous structures, studying the influence of fabrication parameters, such as precursor material concentration and rotating collector speed, on fiber geometry and optical properties. To understand the role of material and fiber geometry on optical performance, we characterize various samples' spectral reflectance, absorptance, and transmittance using spectrophotometers interfaced with integrating spheres. The results show the potential of nanofabricated PTFE-PEO coatings as promising candidates for passive thermal control. We highlight their competitive edge by comparing their solar reflectance and emittance values to existing passive radiative thermal control materials. In essence, this study contributes to advancing passive heat management technologies, offering insights into optimizing material composition and fabrication techniques for enhanced performance in various applications.

Chieloka Ibekwe↗

Studies on spectral analysis of randomly sampled signals: Application to laser velocimetry data

Spectral analysis is very useful in determining the frequency characteristics of many turbulent flows, for example, vortex flows, tail buffeting, and other pulsating flows. It is also used for obtaining turbulence spectra from which the time and length scales associated with the turbulence structure can be estimated. These estimates, in turn, can be helpful for validation of theoretical/numerical flow turbulence models. Laser velocimetry (LV) is being extensively used in the experimental investigation of different types of flows, because of its inherent advantages; nonintrusive probing, high frequency response, no calibration requirements, etc. Typically, the output of an individual realization laser velocimeter is a set of randomly sampled velocity data. Spectral analysis of such data requires special techniques to obtain reliable estimates of correlation and power spectral density functions that describe the flow characteristics. FORTRAN codes for obtaining the autocorrelation and power spectral density estimates using the correlation-based slotting technique were developed. Extensive studies have been conducted on simulated first-order spectrum and sine signals to improve the spectral estimates. A first-order spectrum was chosen because it represents the characteristics of a typical one-dimensional turbulence spectrum. Digital prefiltering techniques, to improve the spectral estimates from randomly sampled data were applied. Studies show that the spectral estimates can be increased up to about five times the mean sampling rate.

Sree, David↗

Determination of rare-earth elements in Luna 16 regolith sample by chemical spectral method

An analysis was made of regolith from layer A of the Luna 16 sample for rare earth elements, by a chemical spectral method. Chemical and ion exchange concentrations were used to determine the content of 12 elements and Y at the level 0.001 to 0.0001 percent with 10 to 15 percent reproducibility of the emission determination. Results within the limits of reproducibility agree with data obtained by mass spectra, activation, and X-ray fluorescent methods.

Stroganova, N. S.↗

Martian Analogue Sample Characterization and Spectral Library Development at the Johnson Space Center

An extensive collection of Martian analogue samples housed at the Johnson Space Center is the focus of ongoing research by the JSC Mars soil genesis group and their collaborators. Because the major element composition of Martian meteorites and in situ analyses of Martian soils and rocks indicate that Mars is predominantly an iron-rich basaltic world, the focus of active sample collection and analysis is basaltic materials and their hydrolytic (both aqueous and hydrothermal) and sulfatetic alteration products. Described below are the scope of the JSC Mars analogue sample collection, the characterization process, and plans to incorporate the data into spectral libraries for the Mars 2003 Mars Exploration Rover (MER) and Mars 2005 Mars Reconnaissance Orbiter (MRO) CRISM missions.

Morris, Richard V.↗