Search NASA⌕ Search

SEARCH · Search NASA

Results for “spray measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Phase/doppler spray analyzer for simultaneous measurements of drop size and velocity distributions

Research was conducted on a laser light scatter detection method for measuring the size and velocity of spherical particles. The method is based upon the measurement of the interference fringe pattern produced by spheres passing through the intersection of two laser beams. A theoretical analysis of the method was carried out using the geometrical optics theory. The instrument response function was determined to be linear with drop size. Experimental verification of the theory was obtained by using monodisperse droplet streams. Several optical configurations were tested to identify all of the parametric effects upon the size measurements. Both off-axis forward-scatter and back-scatter light detection were utilized. Simulated spray environments and fuel spray nozzles were used in the evaluation of the method. The measurements of the monodisperse drops showed complete agreement with the theoretical predictions. The method was demonstrated to be independent of the beam intensity and extinction resulting from the surrounding drops. An instrument based on the concept has been developed.

Bachalo, W. D.↗

Spontaneous Raman–LIF–CO–OH measurements of species concentration in turbulent spray flames

This paper presents new measurements of species concentrations, temperature and mixture fraction in selected regions of a turbulent ethanol spray flame. The line-Raman–LIF–COsingle bondOH setup developed at the Sandia's Combustion Research Facility is utilised to probe regions of a spray flame where laser breakdown of liquid droplets is avoided and the remaining interferences can be corrected. The spray flame is stabilised on the piloted Sydney needle spray burner, where axial translation of the liquid injecting needle in the air-blast stream can transition the spray from dilute to dense. The solution to obtaining successful measurements is found to be multifaceted and includes: the appropriate selection of flame conditions; high sensitivity of the Raman detection system permitting reduced laser energies; development of a pre-processing algorithm to reject strong droplet interferences; and application of the hybrid matrix inversion method combined with wavelet denoising to account for interference corrections and noise at the very low signal levels obtained. Unique and necessary for the successful measurements reported in this paper, a pre-processing algorithm is outlined that removes data points corrupted with strong interferences from droplets. These interferences arise from a range of sources, but the most intense are due to the laser interaction with surrounding mist or liquid fragments, such that measurements near the jet centreline are corrupted and hence discarded. Reliable measurements of mixture fraction, temperature obtained from the sum of the species number densities, and species mole fractions are reported for regions in the flames sufficiently far from the centreline. The paper demonstrates the feasibility of the judicious use of Raman scattering in turbulent spray flames, the results of which will be extremely useful for validating numerical simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements in liquid fuel sprays

Techniques for studying the events directly preceding combustion in the liquid fuel sprays are being used to provide information as a function of space and time on droplet size, shape, number density, position, angle of flight and velocity. Spray chambers were designed and constructed for: (1) air-assist liquid fuel research sprays; (2) high pressure and temperature chamber for pulsed diesel fuel sprays; and (3) coal-water slurry sprays. Recent results utilizing photography, cinematography, and calibration of the Malvern particle sizer are reported. Systems for simultaneous measurement of velocity and particle size distributions using laser Doppler anemometry interferometry and the application of holography in liquid fuel sprays are being calibrated.

Chigier, N.↗

Measurements of Fuel Distribution Within Sprays for Fuel-Injection Engines

Two methods were used to measure fuel distribution within sprays from several types of fuel-injection nozzles. A small tube inserted through the wall of an air tight chamber into which the sprays were injected could be moved about inside the chamber. When the pressure was raised to obtain air densities of 6 and 14 atmospheres, some air was forced through the tube and the fuel that was carried with it was separated by absorbent cotton and weighed. Cross sections of sprays from plain, pintle, multiple-orifice, impinging-jets, centrifugal, lip, slit, and annular-orifice nozzles were investigated, at distances of 1, 3, 5, and 7 inches from the nozzles.

Lee, Dana W↗

A Planar-Fluorescence Imaging Technique for Studying Droplet-Turbulence Interactions in Vaporizing Sprays

Droplet turbulence interactions directly affect the vaporization and dispersion of droplets in liquid sprays and therefore play a major role in fuel oxidizer mixing in liquid fueled combustion systems. Proper characterization of droplet turbulence interactions in vaporizing sprays require measurement of droplet size velocity and size temperature correlations. A planar, fluorescence imaging technique is described which is being developed for simultaneously measuring the size, velocity, and temperature of individual droplets in vaporizing sprays. Preliminary droplet size velocity correlation measurements made with this technique are presented. These measurements are also compared to and show very good agreement with measurements made in the same spray using a phase Doppler particle analyzer.

Santavicca, Dom A.↗

Velocity and drop size measurements in a swirl-stabilized, combusting spray

Velocity and drop size measurements are reported for a swirl-stabilized, combusting spray. For the gas phase, three components of mean and fluctuating velocity are reported. For the droplets, three components of mean and fluctuating velocity, diameter, and number flux are reported. The liquid fuel utilized for all the tests was heptane. The fuel was injected using an air-assist atomizer. The combustor configuration consisted of a center-mounted, air-assist atomizer surrounded by a coflowing air stream. Both the coflow and the atomizing air streams were passed through 45 degree swirlers. The swirl was imparted to both streams in the same direction. The combustion occurred unconfined in stagnant surroundings. The nonintrusive measurements were obtained using a two-component phase/Doppler particle analyzer. The laser-based instrument measured two components of velocity as well as droplet size at a particular point. Gas phase measurements were obtained by seeding the air streams with nominal 1 micron size aluminum-oxide particles and using the measured velocity from that size to represent the gas phase velocity. The atomizing air, coflow air, and ambient surroundings were all seeded with the aluminum-oxide particles to prevent biasing. Measurements are reported at an axial distance of 5 mm from the nozzle. Isothermal single-phase gas velocities are also reported for comparison with the combusting case.

Bulzan, Daniel L.↗

Experimental studies on effervescent atomizers with wide spray angles

An experimental investigation was conducted to examine the operating and spray characteristics of two internal-mixing twin-fluid atomizers that were designed to produce effervescent atomization at low air/liquid mass ratios (ALR's). These two experimental atomizers ejected the two phase flow so as to produce a wide spray angle. One atomizer was a plain orifice design that used a four-hole exit orifice which divided and turned the two phase flow just prior to ejection. The other atomizer, called the conical sheet atomizer, ejected the two phase flow through an annular passage in such a way as to form a hollow cone spray. The atomizer operating parameters varied during this investigation were the air/liquid mass ratio, atomizer operating pressure, and, in the case of the conical sheet atomizer, the exit gap width. Studies of spray characteristics included measurements of the spray Sauter mean diameter (SMD), drop size distribution, and, for the conical sheet atomizer, circumferential distribution of the liquid mass within the spray. For both atomizers it was found that SMD decreases with an increase in either ALR or operating pressure. The effect of ALR on SMD diminishes as the value of ALR increases. For the conical sheet atomizer, when operating at low values of pressure and ALR, SMD increases with increase in gap width, but the influence of gap width on SMD diminishes with an increase in either pressure or ALR. At the highest operating pressure of the conical sheet atomizer (552 kPa), SMD is independent of gap width at all ALR's. For both atomizers, changes in operating pressure and ALR have little effect on the distribution of drop sizes in the spray.

Whitlow, J. D.↗

Nonintrusive optical single-particle counter for measuring the size and velocity of droplets in a spray

A technique for measuring nonintrusively, and in real time, the size and velocity of droplets in a spray is presented. A small beam identifies the center of a larger beam, thus defining a region of almost uniform intensity, and only droplets crossing through such a center are measured. The size is obtained from the absolute scattered light and the velocity from the modulated signal produced by the interferometric pattern. A self-calibrating algorithm is also discussed. Results are presented for a spray of predictable chracteristics.

Hess, C. F.↗

Velocity measurement of particles in sprays

The approach described makes use of high-speed photography employing short-duration light sources. Drops are photographed in flight as they pass through a narrow slice of the spray on which the optical system is focussed. Two sparks fired at intervals of a few microseconds give double image photographs of drops. Drop velocity is calculated by measuring the distance between the two images of the drop and the time interval between sparks. Details regarding the optical and photographic system are described along with the design of the electronics system.

Chigier, N. A.↗

Quasistatic vs. Dynamic Modulus Measurements Of Plasma-Sprayed Thermal Barrier Coatings

Plasma-sprayed 8wt% yttria-stabilized zirconia (8YSZ) thermal barrier coatings (TBCs) have been demonstrated to exhibit nonlinear hysteretic elastic behavior by quasistatic cyclic compression and cylindrical punch indentation measurements. In particular, the instantaneous (tangential) elastic modulus increases with applied stress and exhibits significant hysteresis during cycling. Sound velocity (dynamic) measurements also show an increase in TBC modulus with applied compressive stress, but in contrast show no significant hysteresis for the modulus during cycling. The nonlinear elastic behavior of the TBCs evidenced by these tests is attributed to coating compaction and internal sliding. The differences between the quasistatic and dynamic measurements are explained by the relative absence of the effect of internal sliding in the dynamic modulus measurements. By incorporating short load reversals into the larger loading cycle and measuring the instantaneous modulus at the start of each load reversal, the effects of internal sliding can be substantially reduced in the quasistatic measurements, and the resulting modulus values show good agreement with the modulus values determined by dynamic sound velocity measurements.

Eldridge, J. I.↗

Bio-fuel effects and seasonal fuel property variations related to abnormal combustion occurrences observed in the field

Since 2015, the automotive industry has regularly observed sharp increases in customer complaints of poor driveability and increased warranty claims during the months of September and October. These persistent seasonal complaint increases have been tracked to occur from increased abnormal combustion events that coincide with the seasonal transition from summer to winter fuel volatility, beginning on September 15th annually. The Reid Vapor Pressure (RVP) of gasoline during this seasonal transition has been found to be the primary property attributed to this annual issue. It’s hypothesized that an increase in volatile butanes and pentanes from advanced petroleum recovery techniques and hydrofracking production has hastened the transition from summer to winter fuel volatility in the marketplace, rather than the gradual increase of the RVP over time as historically intended. At worst, mid-winter fuel, with an RVP ranging from 12 to 16 psi, depending on location in the U.S., enters the market while ambient temperatures can still be above average for the winter season. This combination of high volatility fuel with unseasonably warm weather will increase fuel system flash boiling, injector spray cavitation, and spray collapse inside the engine’s combustion chamber, ultimately linking fuel property variations to abnormal engine combustion processes. This CRADA program will investigate these known knowledge gaps by coupling with two national laboratories, Oak Ridge National Laboratory, and the National Renewable Energy Laboratory to employ both unique tools and expertise throughout the industry to provide the insight, knowledge, and data critical to understand the observed interactions. Overall findings of this work are that fuel wall retention increased SPI proportionally, and fuels with an increased distillation (i.e. energy fraction) above the wall temperature increased fuel retention. Likewise fuels with increased enthalpy of vaporization (HoV) increased fuel retention proportional to the temperature reduction from the HoV (~13K reduction in this work). Thus, fuel with increased HoV and increased fuel distillation above the linear temperature also exhibited increased SPI rates. Fuel with high RVP did exhibit increased fuel spray collapse form spray imaging measurements, but in SPI testing the high volatility of these fuels at the tested conditions did not necessarily increase SPI rates despite exhibiting increased spray collapse in injector imaging and increased spray-wall impingement measured in fired engine testing. It was also found that spray imaging showed collapse was possible at throttled conditions, but this was not relevant to high boost pressures relevant to SPI conditions, however, under transient load and or speed encountered in real-world operation fuel spray collapse could affect fuel retention and real-world SPI that were not probed in the automated high load test sequence of this work.

09 BIOMASS FUELS↗

Detailed mixing measurements from single-hole converging ECN injectors using Rayleigh scattering

Time resolved liquid and vapor fields of dodecane and oxymethylene ethers are measured from Spray A-3 and Spray D using high speed Rayleigh scattering and diffuse back illumination at the Engine Combustion Network (ECN) Spray A condition of 900 K and 22.8 kg/m 3 . Global quantities including mixture fraction, vapor and liquid penetration, as well as spreading angle are measured. The mixture fraction fields and vapor penetration profiles are well predicted by the 1-D Musculus-Kattke model. The mixture fraction field and vapor penetration from Spray A-3 are similar to those measured from Spray A in previous works. Spray D exhibits higher mixture fraction fields and vapor penetration due to its larger nozzle diameter. The quasi-steady mixture fraction fields from these injectors scale well when distance from the injector is normalized by the nozzle diameter. The turbulent dissipation structures were also analyzed based on the orientation, thickness, and magnitude of the mixing layers. Furthermore, the orientation and thickness are similar to other measurements in atmospheric gas jets, while the magnitude is lower. The thickness and magnitude are subject to uncertainties due to limitations in the imaging resolution of the system but still provide an order of magnitude as a useful reference for comparison against computational fluid dynamic simulations.

33 ADVANCED PROPULSION SYSTEMS↗

Velocity and drop size measurements in a confined, swirl-stabilized, combusting spray

Drop size and velocity measurements in a confined, swirl-stabilized, reacting spray are presented. The configuration consisted of a center-mounted research air-assist atomizer surrounded by a coflowing air stream. A quartz tube surrounded the burner and provided the confinement. Both the air-assist and coflow streams had swirl imparted to them in the same direction with 45-degree-angle swirlers. The fuel and air entered the combustor at ambient temperature. The gas-phase measurements reported were obtained from the velocity drops with a mean diameter of four microns. Heptane fuel was used for all the experiments. Measurements of drop size and velocity, gas-phase velocity and drop number flux are reported for axial distances of 23, 5, 10, 15, 25, and 50 mm downstream of the nozzle. The measurements were performed using a two-component phase/Doppler particle analyzer. Profiles across the entire flowfield are presented.

Bulzan, Daniel L.↗

The Effects of Sooting and Radiation on Droplet Combustion

The burning of liquid hydrocarbon fuels accounts for a significant portion of global energy production. With predicted future increases in demand and limited reserves of hydrocarbon fuel, it is important to maximize the efficiency of all processes that involve conversion of fuel. With the exception of unwanted fires, most applications involve introduction of liquid fuels into an oxidizing environment in the form of sprays which are comprised of groups of individual droplets. Therefore, tremendous benefits can result from a better understanding of spray combustion processes. Yet, theoretical developments and experimental measurements of spray combustion remains a daunting task due to the complex coupling of a turbulent, two-phase flow with phase change and chemical reactions. However, it is recognized that individual droplet behavior (including ignition, evaporation and combustion) is a necessary component for laying the foundation for a better understanding of spray processes. Droplet combustion is also an ideal problem for gaining a better understanding of non-premixed flames. Under the idealized situation producing spherically-symmetric flames (produced under conditions of reduced natural and forced convection), it represents the simplest geometry in which to formulate and solve the governing equations of mass, species and heat transfer for a chemically reacting two phase flow with phase change. The importance of this topic has promoted extensive theoretical investigations for more than 40 years.

Lee, Kyeong-Ook↗

A Spectroscopic Measurement of High Velocity Spray Plasma from an M-Class Flare and Coronal Mass Ejection

The M1.5-class flare and associated coronal mass ejection (CME) of 16 February 2011 was observed with the Extreme ultraviolet Imaging Spectrometer on board the Hinode spacecraft. Spray plasma associated with the CME is found to exhibit a Doppler blue-shift of 850 km s−1 – one of the largest values reported from spectroscopy of the solar disk and inner corona. The observation is unusual in that the emission line (Fe xii 193.51 Å) is not observed directly, but the Doppler shift is so large that the blue-shifted component appears in a wavelength window at 192.82 Å, intended to observe lines of O v, Fe xi and Ca xvii. The Fe xii 195.12 Å emission line is used as a proxy for the rest component of 193.51 Å. The observation highlights the risks of using narrow wavelength windows for spectrometer observations when observing highly-dynamic solar phenomena. The consequences of large Doppler shifts for ultraviolet solar spectrometers, including the upcoming Multi-slit Solar Explorer (MUSE) mission, are discussed.

Solar atmosphere↗

Measurements and predictions of a liquid spray from an air-assist nozzle

Droplet size and gas velocity were measured in a water spray using a two-component Phase/Doppler Particle Analyzer. A complete set of measurements was obtained at axial locations from 5 to 50 cm downstream of the nozzle. The nozzle used was a simple axisymmetric air-assist nozzle. The sprays produced, using the atomizer, were extremely fine. Sauter mean diameters were less than 20 microns at all locations. Measurements were obtained for droplets ranging from 1 to 50 microns. The gas phase was seeded with micron sized droplets, and droplets having diameters of 1.4 microns and less were used to represent gas-phase properties. Measurements were compared with predictions from a multi-phase computer model. Initial conditions for the model were taken from measurements at 5 cm downstream. Predictions for both the gas phase and the droplets showed relatively good agreement with the measurements.

Bulzan, Daniel L.↗

Measurements and predictions of a liquid spray from an air-assist nozzle

Droplet size and gas velocity were measured in a water spray using a two-component Phase/Doppler Particle Analyzer. A complete set of measurements was obtained at axial locations from 5 to 50 cm downstream of the nozzle. The nozzle used was a simple axisymmetric air-assist nozzle. The sprays produced, using the atomizer, were extremely fine. Sauter mean diameters were less than 20 microns at all locations. Measurements were obtained for droplets ranging from 1 to 50 microns. The gas phase was seeded with micron sized droplets, and droplets having diameters of 1.4 microns and less were used to represent gas-phase properties. Measurements were compared with predictions from a multi-phase computer model. Initial conditions for the model were taken from measurements at 5 cm downstream. Predictions for both the gas phase and the droplets showed relatively good agreement with the measurements.

Bulzan, Daniel L.↗