Search NASA⌕ Search

SEARCH · Search NASA

Results for “stable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Chlorine stable isotopes in sedimentary systems: does size matter?

Stable isotope abundances vary because of size differences. The chlorine stable isotope system was one of the first described theoretically, but had a slow, disappointment strewn development, relative to other elements. Method improvement gave only small, but significant, differences in compositions of geological materials. Eventually, brines and groundwater chlorides gave larger differences. Physical processes like diffusion and adsorption, probably are the main controls of groundwater compositions. Recent work on anthropogenic groundwater contaminants shows variations resulting from manufacturing processes; implying possibilities of tracing sources.

chlorine stable isotopes↗

Ultra-Stable Oscillators for Probe Radio Science Investigations

An Ultra-Stable Oscillator (USO) is: A frequency reference, and A clock It is stable, small, and sensitive. It is a science and an art form. It is flown on spacecraft/probes. It]is utilized at ground stations alone or as a cleanup loop. It eliminates lock-up time on uplink for occultation egress & effect of media on uplink signal. It has enabled significant planetary science investigations.

Ultra-Stable Oscillator (USO)↗

Chip Scale Ultra-Stable Clocks: Miniaturized Phonon Trap Timing Units for PNT of CubeSats

The Chip Scale Ultra-Stable Clocks (CSUSC) project aims to provide a superior alternative to current solutions for low size, weight, and power timing devices. Currently available quartz-based clocks have problems adjusting to the high temperature and extreme acceleration found in space applications, especially when scaled down to match small spacecraft size, weight, and power requirements. The CSUSC project aims to utilize dual-mode resonators on an ovenized platform to achieve the exceptional temperature stability required for these systems. The dual-mode architecture utilizes a temperature sensitive and temperature stable mode simultaneously driven on the same device volume to eliminate ovenization error while maintaining extremely high performance. Using this technology it is possible to achieve parts-per-billion (ppb) levels of temperature stability with multiple orders of magnitude smaller size, weight, and power.

Dual-mode resonators↗

Impact of Jason-2/T2L2 Ultra-Stable-Oscillator Frequency Model on DORIS stations coordinates and Earth Orientation Parameters

Doppler Orbitography and Radiopositioning Integrated on Satellite (DORIS)is a tracking technique based on a one-way ground to space Doppler link.For Low Earth Orbit (LEO) satellites, DORIS shows a robust capability interms of data coverage and availability, due to a wide and well-distributedground network, where data are made available by the International DorisService (IDS). However, systematic errors remain in the DORIS data, suchas instabilities of the on-board clock due to radiation encountered in space,which limit the accurate determination of station positions.The DORIS on-board clock frequency stability is degraded by the increased radiation found in the region of the South Atlantic Anomaly (SAA)and has been shown to degrade station position estimation. This paper in-troduces a new model correction to the DORIS data for the frequency ofthe Jason-2 Ultra Stable Oscillator (USO), derived from the Time Transferby Laser Link (T2L2) experiment (Belli and Exertier, 2018). We show thata multi-satellite DORIS solution including this T2L2-corrected data appliedto the frequency modelling for The DORIS data, improves the estimationof station coordinates. We show the tie residuals with respect to collocatedGPS stations are improved by several millimeters. We also demonstratethat the 117-day (Jason-2) draconitic signal in the geophysical parametersis reduced, implying that the origin of this signal is not just solar radiationpressure mis-modeling, but also radiation-induced clock perturbations onthe Jason-2 DORIS Ultra-Stable-Oscillator (USO). Finally we demonstratethrough comparisons with the International Earth Rotations and ReferenceSystems Service (IERS) C04 series for Earth Orientation Parameters (EOP),that the estimation of EOP is improved in both a Jason-2 DORIS-only anda multi-satellite DORIS solution for EOP.

DORIS↗

Noble Gases and Stable Isotopes Track the Origin and Early Evolution of the Venus Atmosphere

The composition the atmosphere of Venus results from the integration of many processes entering into play over the entire geological history of the planet. Determining the elemental abundances and isotopic ratios of noble gases (He, Ne, Ar, Kr, Xe) and stable isotopes (H, C, N, O, S) in the Venus atmosphere is a high priority scientific target since it could open a window on the origin and early evolution of the entire planet. This chapter provides an overview of the existing dataset on noble gases and stable isotopes in the Venus atmosphere. The current state of knowledge on the origin and early and long-term evolution of the Venus atmosphere deduced from this dataset is summarized. A list of persistent and new unsolved scientific questions stemming from recent studies of planetary atmospheres (Venus, Earth and Mars) are described. Important mission requirements pertaining to the measurement of volatile elements in the atmosphere of Venus as well as potential technical difficulties are outlined.

noble gases↗

Safe atmosphere entry of an isotope heat source with a single stable trim attitude at hypersonic speeds

A theoretical investigation has been made to design an isotope heat source capable of satisfying the conflicting thermal requirements of steady-state operation and atmosphere entry. The isotope heat source must transfer heat efficiently to a heat exchange during normal operation with a power system in space, and in the event of a mission abort, it must survive the thermal environment of atmosphere entry and ground impact without releasing radioactive material. A successful design requires a compatible integration of the internal components of the heat source with the external aerodynamic shape. To this end, configurational, aerodynamic, motion, and thermal analyses were coupled and iterated during atmosphere entries at suborbital through superorbital velocities at very shallow and very steep entry angles. Results indicate that both thermal requirements can be satisfied by a heat source which has a single stable aerodynamic orientation at hypersonic speeds. For such a design, the insulation material required to adequately protect the isotope fuel from entry heating need extend only half way around the fuel capsule on the aerodynamically stable (wind-ward) side of the heat source. Thus, a low-thermal-resistance, conducting heat path is provided on the opposite side of the heat source through which heat can be transferred to an adjacent heat exchanger during normal operation without exceeding specified temperature limits.

Levy, L. L., Jr.↗

On stiffly stable implicit linear multistep methods.

The motivation to increase the step size with no degradation of numerical accuracy and stability has led to the discovery of particular members of the class of stiffly stable implicit linear multistep algorithms. Sufficient conditions for a consistent linear multistep method to be stiffly stable are given. These conditions involve properties of the stability mapping from the extended complex plane onto itself.

Cooke, C. H.↗

Stability of large-scale systems with stable and unstable subsystems.

The purpose of this paper is to develop new methods for constructing vector Liapunov functions and broaden the application of Liapunov's theory to stability analysis of large-scale dynamic systems. The application, so far limited by the assumption that the large-scale systems are composed of exponentially stable subsystems, is extended via the general concept of comparison functions to systems which can be decomposed into asymptotically stable subsystems. Asymptotic stability of the composite system is tested by a simple algebraic criterion. With minor technical adjustments, the same criterion can be used to determine connective asymptotic stability of large-scale systems subject to structural perturbations. By redefining the constraints imposed on the interconnections among the subsystems, the considered class of systems is broadened in an essential way to include composite systems with unstable subsystems. In this way, the theory is brought substantially closer to reality since stability of all subsystems is no longer a necessary assumption in establishing stability of the overall composite system.

Grujic, Lj. T.↗

Quadrupole mass filter with means to generate a noise spectrum exclusive of the resonant frequency of the desired ions to deflect stable ions

A mass spectrometer for the separation or separate indication of ions of different specific electric charges is reported. The instrument uses a periodically varying electric field in its analyzing section to excite the injected ions into oscillations while traveling along their trajectories which are either stable or unstable depending on specific parameters. Only stable trajectory ions pass through the electric field to the collector for indication.

Langmuir, R. V.↗

Stable longitudes for 12-hr eccentric orbit satellites.

The accelerated longitude drift regimes of eccentric 12-hr orbits are considered, due to the resonant geopotential. These quasi-stationary orbits are under investigation at NASA for large payload earth surveillance spacecraft in the small applications technology satellite (SATS) program. Inclinations near 'critical' are especially attractive because of their possible long term stability, and these are examined in detail. 'Stable' equator crossing longitudes for these satellites are found as functions of the argument of perigee. As long as the argument of perigee is between plus or minus 100 deg, these stable longitudes lie within a narrow range. Maximum 'east-west' stationkeeping requirements for these satellites at nonequilibrium positions are in the range of 0.3 to 3 m/sec/yr.

Wagner, C. A.↗

Forward slanted slot throat stability bypass to increase the stable airflow range of a Mach 2.5 inlet with 60 percent internal contraction

The results of an experimental investigation to increase the stable airflow operating range of a supersonic mixed-compression inlet are presented. Two forward-slanted slot stability-bypass entrance configurations were tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of 18.5 percent was obtained with the superior configuration if a constant pressure was maintained in the bypass plenum. Limited unstart angle-of-attack data are presented.

Shaw, R. J.↗

Distributed porous throat stability bypass to increase the stable airflow range of a Mach 2.5 inlet with 60 percent internal contraction

The results of an experimental investigation to increase the stable airflow operating range of a supersonic, mixed-compression inlet with 60-percent internal contraction are presented. Various distributed-porous, throat stability-bypass entrance configurations were tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of about 25 percent was obtained with the optimum configuration if a constant pressure was maintained in the by-pass plenum. The location of the centerbody bleed region had a decided effect on the overall inlet performance. Limited unstart angle-of-attack data are presented.

Shaw, R. J.↗

Distributed educated throat stability bypass to increase the stable airflow range of a Mach 2.5 inlet with 60-percent internal contraction

The results of an experimental investigation to increase the stable airflow operating range of a supersonic mixed-compression inlet are presented. A distributed educated throat stability-bypass entrance configuration was tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of about 16.1 percent was obtained if a constant pressure was maintained in the bypass plenum. Limited unstart angle of attack data are presented.

Shaw, R. J.↗

Pressure activated stability-bypass-control valves to increase the stable airflow range of a Mach 2.5 inlet with 40 percent internal contraction

The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. The inlet stable airflow range provided by various stability-bypass entrance configurations in alternate combination with several stability-bypass exit controls was determined for both steady-state conditions and internal transient pulses. Transient results were also obtained for the inlet with a choke point at the diffuser exit. Instart angles of attack were determined for the various stability-bypass entrance configurations. The response of the inlet-coldpipe system to internal and external oscillating disturbances was determined. Poppet valves at the stability-bypass exit provided an inlet stable airflow range of 28 percent or greater at all static and transient conditions.

Mitchell, G. A.↗

Spectroradiometric calibration techniques in the far ultraviolet - A stable emission source for the Lyman bands of molecular hydrogen

The problems associated with making accurate spectroradiometric measurements in the far UV region are sketched briefly. The equipment and methods that were developed for providing absolute sensitivity calibration of an Apollo 17 far UV spectrometer are described. The absolute reference standards were photoelectric diodes calibrated at the National Bureau of Standards. A complete vacuum optical facility, which included a premonochromator and stable UV light sources, was developed to calibrate the Apollo 17 instrument, and it has been used for a number of other tasks. Absolute radiometric calibrations between about 1200 and 1700 A were performed with an absolute accuracy of + or - 10%. The light source, which was designed to provide a very stable light output, is a low-pressure molecular hydrogen lamp in which the pressure is stabilized by thermal control of uranium hydride powder.-

Fastie, W. G.↗

Poppet valve control of throat stability bypass to increase stable airflow range of a Mach 2.5. inlet with 60 percent internal contraction

The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. System variations included several stability bypass entrance configurations. Poppet valves controlled the bypass airflow. The inlet stable airflow range achieved with each configuration was determined for both steady state conditions and internal pulse transients. Results are compared with those obtained without a stability bypass system. Transient results were also obtained for the inlet with a choke point at the diffuser exit and for the inlet with large and small stability bypass plenum volumes. Poppet valves at the stability bypass exit provided the inlet with a stable airflow range of 20 percent or greater at all static and transient conditions.

Mitchell, G. A.↗

A class of stable, robust feedback controllers for large space structures

A two-level control system design is considered for large space structures, which consists of a primary and a secondary controller. The secondary or damping enhancement controller is shown to be stable and robust, even when time-invariant nonlinearities are present in the actuators and/or sensors. The use of Annular Momentum Control Devices (AMCD's) is also considered for secondary control. The primary attitude controller using collocated torque actuators and attitude and rate sensors is stable and robust. The effect of actuator/sensor dynamics on the stability of the primary and secondary controllers is considered. The AMCD's used for secondary control actuation can also be used for the primary controller.

Joshi, S. M.↗

Finite-element analysis of initiation, stable crack growth and instability using a crack-tip-opening displacement criterion

An elastic-plastic (incremental and small strain) finite element analysis was used with a crack growth criterion to study crack initiation, stable crack growth, and instability under monotonic loading to failure of metallic materials. The crack growth criterion was a critical crack-tip-opening displacement (CTOD) at a specified distance from the crack tip, or equivalently, a critical crack-tip-opening angle (CTOA). Whenever the CTOD (or CTOA) equaled or exceeded a critical value, the crack was assumed to grow. Single values of critical CTOD were used in the analysis to model crack initiation, stable crack growth, and instability for 7075-T651 and 2024-T351 aluminum alloy compact specimens. Calculated and experimentally measured CTOD values at initiation agreed well for both aluminum alloys. These critical CTOD values were also used to predict failure loads on center-crack tension specimens and a specially-designed three-hole-crack tension specimen made of the two aluminum alloys and of 304 stainless steel. All specimens were 12.7 mm thick. Predicted failure loads for 7075-T651 aluminum alloy and 304 stainless steel specimens were generally within + or - 15 percent of experimental failure loads, whereas the predicted failure loads for 2024-T351 aluminum alloy specimens were generally within + or - 5 percent of the experimental loads.

Newman, J. C., Jr.↗