A shock tube study of line broadening in a temperature range of 6100 to 8300 K

Line widths of the Ca(II) 3968 A and Na(I) 5890 A resonance lines broadened by electric microfields in a plasma were measured. A pressure-driven shock tube was used as the light source. Radiation from the equilibrium region behind the reflected shock wave was studied using a rapid scanning Fabry-Perot interferometer. Electron and argon atom densities of about 8 x 10 to the 16th and 1 x 10 to the 19th/cu cm, respectively, were achieved at the relatively low temperature of around 7500 K by vaporizing a cesium powder that had been added to the shock tube as a solid aerosol in argon gas. The measured line widths were predominantly Stark broadened by the electrons and ions in the plasma, although Doppler, van der Waals, instrument function and optical depth effects had to be taken into account.

Baur, J. F.↗

Experimental characterization of discharge plasma dynamics in a square capillary for prospective applications in laser wakefield acceleration

Research on plasma generated by electrical discharge in gas-filled capillaries plays an important role in advancing laser wakefield accelerators. We present a comprehensive study of the temporal and spatial distribution of plasma density within a short, 1 cm long, square-shaped capillary filled with hydrogen gas. Two transverse capillary sizes, 500 μm and 300 μm, were investigated achieving peak plasma densities of 0.9 × 10 18 cm −3 and 2.5 × 10 18 cm −3 , respectively, at the capillary center. In addition, we explore how these distributions depend on discharge parameters, specifically discharge current and gas flow through the capillary. Plasma density was determined by analyzing the Stark broadening of the hydrogen Balmer-alpha line. The results obtained were compared with the theoretical models and simulations. The comparison between the model predictions and the experimental data at the transient ionization stage of the discharge reveals a discrepancy of a factor of ∼1.3–2.1, depending on the capillary size, which is thoroughly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid-Density Ion Temperature from Redshifted and Double-Peaked Stark Line Shapes

Heβ spectral line shapes are important for diagnosing temperature and density in many dense plasmas. This work presents Heβ line shapes measured with high spectral resolution from solid-density plasmas with minimized gradients. The line shapes show hallmark features of Stark broadening, including quantifiable redshifts and double-peaked structure with a significant dip between the peaks; these features are compared to models through a Markov chain Monte Carlo framework. Line shape theory using the dipole approximation can fit the width and peak separation of measured line shapes, but it cannot resolve an ambiguity between electron density n e and ion temperature T i , since both parameters influence the strength of quasistatic ion microfields. Here a line shape model employing a full Coulomb interaction for the electron broadening computes self-consistent line widths and redshifts through the monopole term; redshifts have different dependence on plasma parameters and thus resolve the n e – T i ambiguity. The measured line shapes indicate densities that are 80–100% of solid, identifying a regime of highly ionized but well-tamped plasma. This analysis also provides the first strong evidence that dense ions and electrons are not in thermal equilibrium, despite equilibration times much shorter than the duration of x-ray emission; cooler ions may arise from nonclassical thermalization rates or anomalous energy transport. Furthermore, the experimental platform and diagnostic technique constitute a promising new approach for studying ion-electron equilibration in dense plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying Regimes During Plasma Catalytic Ammonia Synthesis

Herein, we demonstrate that the performance of mesoporous silica SBA-15 and SBA-15-Ag during plasma ammonia synthesis depends on the plasma conditions. At high power, the mesoporous silica SBA-15 without Ag produces the largest amount of ammonia, but the addition of Ag provides a minor benefit at lower powers. Plasma conditions were analyzed through optical emission spectroscopy using N 2 , N 2 + , and NH molecular bands and H α line. Stark broadening of H α line was used to find electron density, and N 2 molecular bands were used to assess N 2 vibrational excitation, important for plasma nitrogen decomposition. At similar input conditions, reactors with SBA-15 have higher electron density and higher N 2 vibrational temperature. Consistent with higher electron density, SBA-15 reactors have stronger N 2 + emission intensity relative to the neutral N 2 . The addition of Ag results in higher N 2 rotational temperature, possibly due to localized heating. From the materials point of view, SBA-15 is a more robust catalyst with good surface area retention after plasma exposure due to the lack of local heating generated when a metal is in the structure. Furthermore, we identify two possible regimes during ammonia synthesis, a metal and a surface-plasma driven. At lower plasma densities, the addition of metal is beneficial, while at higher power and plasma density, the best performance is achieved without the aid of a metal catalyst.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser absorption measurements of electron density in nanosecond-scale atmospheric pressure pulsed plasmas

We report on time-resolved measurements of electron number density by continuous-wave laser absorption in a low-energy nanosecond-scale laser-produced spark in atmospheric pressure air. Laser absorption is a result of free-free and bound-free electron excitation, with the absorption coefficient modeled and evaluated using estimates of the time-variation in electron temperature and probe laser absorption path length. Plasma electron number densities are determined to be as high as n e = 7 x 10 19 cm -3 , and decay to 1/e of their peak values over a period of about 50 ns following plasma formation using a 20 mJ, 10 ns pulse width frequency-doubled Nd:YAG laser. The measured plasma densities at later times are shown to be in reasonable agreement with Stark broadening measurements of the 3s[ 5 S o ]-3p[ 5 P] electronic transition in atomic oxygen at 777 nm. This study provides support for the use of such continuous wave laser absorption for time resolved electron density measurements in low energy spark discharges in air, provided that an estimate of the electron temperature and laser path length can be made by accompanying diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First observations from the Kr multi-monochromatic x-ray imager for time and spatially resolved diagnosis of hot implosion cores

This paper presents initial findings from the recently deployed Kr multi-monochromatic x-ray imager (Kr MMI) at the Omega laser facility. The experiment focuses on exploring implosion dynamics in exploding pusher capsules at three distinct initial gas fill densities. Utilizing time-gated and spatially integrated measurements, core size, electron temperature (Te), and electron densities (ne) are extracted through the analysis of the spectral region encompassing the Kr He α and its satellite lines. A comprehensive spectral database, incorporating atomic kinetics, spectroscopic-quality radiation transport, and Stark broadened line shapes, has been developed for rigorous data analysis. These measurements underscore the utility of the new Kr MMI instrument, which, combined with sophisticated analysis techniques, enables the diagnosis of plasma conditions at Te>2000 eV, thereby extending the capabilities beyond the prior Ar MMI design. This is an important stepping stone for achieving time-gated and space-resolved diagnostics of electron temperature, electron density, and heat transport in high temperature implosion cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unipolar arc plasmas on nanostructured tungsten surfaces under perpendicular magnetic field

Abstract Unipolar arcing is an important phenomenon in terms of wall erosion and the subsequent plasma contamination in nuclear fusion devices. In this study, unipolar arc plasmas are experimentally explored under the presence of the external magnetic field perpendicular to a tungsten (W) sample on which a ‘fuzz’ nanostructure surface is formed. It is found that the fuzz layer thickness, d fuzz , plays a dominant role in determining the motion of arc spots, the arc ignition probability, and arc plasma parameters. High-speed imaging reveals that the motion of arc spots becomes more collective, as d fuzz increases. Interestingly, arc spots make a circle while moving outward. With increasing d fuzz , the amount of eroded W atoms increases, as indicated from an observed increase in the total visible emission intensity, while the arc ignition probability is found to drop. The physical mechanisms are discussed, in detail, based on spectroscopic measurements of the electron temperature, obtained from Boltzmann plots of both W I and W II, and the electron density, determined from Stark broadening of W I lines.

Physics↗

On the origins of the continuum radiation of an underwater nanosecond pulsed discharge: an absolute-intensity optical emission spectroscopy study

The plasma properties of an underwater nanosecond pulsed discharge remain not fully understood despite being extensively studied for several decades. In this work, we focus on the continuum radiation generated in such discharges. The discharge is characterized by power measurements as well as by absolute emission spectroscopy. When observed, Stark broadenings of H α , H β and O (777 nm) are employed for electron number densities measurements. The discharge was generated by a 10 ns main voltage pulse followed by multiple secondary pulses, which last up to 4 μs after the primary pulse. It is shown that a peak power of 3.5 MW and energy of 35 mJ is coupled during the main voltage pulse. A quantitative estimation of the different possible continuum radiation sources is performed through analytical calculations. This includes emission (blackbody, free–bound and free–free bremsstrahlung radiations) and absorption (electron–ion and electron–neutral free–free inverse bremsstrahlung) mechanisms. Our results suggest that electron–neutral free–free bremsstrahlung is the principal mechanism responsible for the strong continuum radiation observed experimentally during the primary pulse. We also show that self-absorption through electron–neutral (and electron–ion) inverse bremsstrahlung plays an important role in the main discharge pulse. Further, our results indicate the non-negligible additional contribution of the H 2 continuum during the first reflected pulse which is likely ignited in bubbles generated by the first discharge pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hot Spot Evolution Measured by High-Resolution X-Ray Spectroscopy at the National Ignition Facility

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He β spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. Here these advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vacuum ultraviolet radiometry with a stabilized hydrogen arc.

Use of the spectral radiation emitted from a dense hydrogen plasma of at least 12,000 K, which is in local thermodynamic equilibrium (LTE), as a light source for vacuum UV radiometry. Its spectroscopic qualities are exactly known, and except for a few strongly Stark-broadened Lyman lines, its spectrum in the vacuum UV is essentially continuous. The calculated continuum output of this source for typical operating conditions is compared with the UV output of the tungsten strip lamp and the carbon arc.

Ott, W. R.↗

CPD-31 1701, an extremely helium-rich subluminous O-type star.

The bluest of thee 1500 southern OB stars discovered during an extensive photometric (UBV) and spectroscopic (MK) study of galactic structure in the southern hemisphere is discussed. The spectrum of this strikingly peculiar star is completely dominated by lines of neutral and ionized helium, most of which are extremely Stark-broadened. The spectral type is 08, with V = 10.52, B-V = -0.31, and U-B = -1.17. The absolute magnitude is probably +3. Located in the plane of the Milky Way, the CPD 31 1701 is hot, very underluminous, and extremely helium-rich.

Garrison, R. F.↗

On the effect of time-ordering for Lyman-alpha

Numerical calculations of the wings of the hydrogen Lyman-alpha line due to Stark broadening by electrons have been performed including time ordering effects. It is concluded that two recent calculations, which apparently disagree, are numerically correct within their respective approximations and their differences are explained.

Greene, R. L.↗

Dense plasma focus production in a hypocycloidal pinch

A type of high-power pinch apparatus consisting of disk electrodes was developed, and diagnostic measurements to study its mechanism of dense plasma production were made. The collapse fronts of the current sheets are well organized, and dense plasma focuses are produced on the axis with radial stability in excess of 5 microns. A plasma density greater than 10 to the 18th power/cubic cm was determined with Stark broadening and CO2 laser absorption. A plasma temperature of approximately 1 keV was measured with differential transmission of soft X-rays through thin foils. Essentially complete absorption of a high-energy CO2 laser beam was observed. The advantages of this apparatus over the coaxial plasma focus are in (1) the plasma volume, (2) the stability, (3) the containment time, (4) the easy access to additional heating by laser or electron beams, and (5) the possibility of scaling up to a multiple array for high-power operation.

Lee, J. H.↗