Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comparison of low-latitude ion and neutral zonal drifts using DE 2 data

We have used data from the ion drift meter and the wind and temperature spectrometer on the DE 2 spacecraft to make statistical comparisons of the zonal ion and neutral drifts at dip latitudes (DLAT) in the +/- 35 deg range over all local times. Fourier analysis indicates that the superrotation and the diurnal components of both flows are strongly peaked at the dip equator, with the superrotation term becoming negative for the absolute value DLAT greater than or equal 20 deg. One interesting feature is the presence of a period (2200-0500 solar local time) in the 300-400 km altitude region near the dip equator where the ion drift is more strongly eastward than the neutral flow. This would seem to indicate the presence of an electric field source of greater strength than the F region dynamo elsewhere along the geomagnetic field line. Model calculations indicate that a possible mechanism for this source lies in the vertical shear in the zonal neutral wind in the 100-200 km altitude region.

Coley, W. R.↗

Dosimetric effect of beam arrangement for intensity-modulated radiation therapy in the treatment of upper thoracic esophageal carcinoma

To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V{sub 5}, V{sub 13}, V{sub 20}, mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V{sub 30} for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

Surface Pressure Fluctuations Induced by a Hypersonic Turbulent Boundary Layer on a Sharp Cone at Angle of Attack

High-fidelity simulations are performed to characterize the turbulence-induced wall pressure fluctuations on a sharp cone at a 5.5° angle-of-attack in a Mach 8 flow. Wall-resolved large-eddy simulation (LES) and wall-modeled large-eddy simulation (WMLES) results are compared to measurements at several locations on the cone body, where comparisons with high-frequency PCB sensors are good, while comparison with low-frequency kulite sensors varies depending on the location. For a given streamwise location, simulation results show significant azimuthal variation in the wall pressure fluctuation statistics. Comparisons between LES and WMLES results indicate that WMLES can accurately reproduce the low-frequency component of the autospectra quite well, while slight sensitivity is apparent in the coherence. A grid sensitivity study for WMLES further demonstrated sensitivity in the wall pressure fluctuation coherence, but not in the autospectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LANDSAT-4 MSS interband registration

Interband registration on raw LANDSAT-4 MSS data was measured in the four MSS bands of the Mistassini, Quebec scene (path-row 16-24, June 21, 1983). Statistical comparison between line-pixel locations of uniformly distributed ground control points in the four different bands permitted quantitative measures of the offset over the entire scene. The statistical distribution of the offset measures permitted evaluation of the standard error on the mean values, giving confidence on their precision. Results obtained using a manual ground control point done on a digital image correction system and those obtained using digital band-to-band correlation adapted from a digital stereographic correlation algorithm are tabulated. The pixel misrepresentation values obtained are compared with published NASA figures.

Grieve, G.↗

Comparing two correlated C indices with right‐censored survival outcome: a one‐shot nonparametric approach

The area under the receiver operating characteristic curve is often used as a summary index of the diagnostic ability in evaluating biomarkers when the clinical outcome (truth) is binary. When the clinical outcome is right‐censored survival time, the C index, motivated as an extension of area under the receiver operating characteristic curve, has been proposed by Harrell as a measure of concordance between a predictive biomarker and the right‐censored survival outcome. In this work, we investigate methods for statistical comparison of two diagnostic or predictive systems, of which they could either be two biomarkers or two fixed algorithms, in terms of their C indices. We adopt a U ‐statistics‐based C estimator that is asymptotically normal and develop a nonparametric analytical approach to estimate the variance of the C estimator and the covariance of two C estimators. A z ‐score test is then constructed to compare the two C indices. We validate our one‐shot nonparametric method via simulation studies in terms of the type I error rate and power. We also compare our one‐shot method with resampling methods including the jackknife and the bootstrap. Simulation results show that the proposed one‐shot method provides almost unbiased variance estimations and has satisfactory type I error control and power. Finally, we illustrate the use of the proposed method with an example from the Framingham Heart Study. Copyright © 2014 John Wiley & Sons, Ltd.

Kang, Le↗

Improved Soil Moisture Estimation and Detection of Irrigation Signal By Incorporating SMAP Soil Moisture Into the Indian Land Data Assimilation System (ILDAS)

Land surface models have facilitated the estimation of soil moisture over a range of spatiotemporal scales. However, limitations in model parameterization and under-representation of anthropogenic processes restrict their ability to estimate local-scale soil moisture variability, especially over irrigated areas. Assimilation of satellite-based soil moisture retrievals into land surface models can be a viable approach to overcome these constraints, specially over highly irrigated countries such as India, where such applications are rare. Additionally, large-scale validation of modeled soil moisture has been limited over India till now due to lack of a representative station network. By assimilating Soil Moisture Active Passive (SMAP)-based estimates into the state-of-the-art Indian Land Data Assimilation System (ILDAS) and combining with a new soil moisture station network of more than 200 stations, this study demonstrates improved soil moisture estimations and capture of irrigation signals over the region. The Noah-MP land surface model is forced by multiple local and global meteorological datasets and Ensemble Kalman Filter (EnKF) is used for assimilation of soil moisture. Comparison of open-loop and data assimilated soil moisture against station soil moisture data shows relative spatial mean improvement of 0.0178 in correlation and 0.0029 m3/m3 in RMSE. Further statistical comparison with in-situ data has also shown better results over most of the stations, as evident from improved correlations and reduced unbiased RMSE after assimilation. Finally, the climatology of soil moisture over the different irrigation fractions reveals that data assimilated outputs over irrigated grid cells tend to have higher soil moisture during dry winter season, demonstrating the ability to capture irrigation signals. These findings quantify the value of data assimilation in improving soil moisture estimates and the ability to capture unmodeled processes such as irrigation, which lays the science groundwork for upcoming space missions such as NASA ISRO Synthetic Aperture Radar (NISAR).

Soil Moisture↗

Inorganic Element Concentrations in Passerine Eggs Collected at Technical Areas 36, 39, and 16 at Los Alamos National Laboratory

In 2018, nonviable avian eggs were opportunistically collected at Los Alamos National Laboratory near open detonation sites at Technical Area (TA) 36 and TA-39 and near the TA-16 burning grounds and were evaluated for inorganic elements (mostly metals). A total of eight western bluebird Sialia mexicana ) and ash-throated flycatcher ( Myiarchus cinerascens ) egg samples were collected among the three locations of interest. Due to the small sample size, statistical comparisons could not be made. However, concentrations of inorganic elements observed in this study were compared with the upper-level bounds of background concentrations (mean + three standard deviations = 99% confidence interval; regional statistical reference level [RSRL]). Several inorganic elements were not detected in avian eggs and the majority of inorganic elements detected were below the RSRL. The few elements that exceeded the RSRL were below the lowest observable adverse effect level (LOAEL), when available. These data suggest that inorganic element concentrations in eggs observed here are not of ecological concern. As these data are preliminary, more data are needed to make a robust assessment, including additional background samples.

54 ENVIRONMENTAL SCIENCES↗

Use of vision and sound to classify feller-buncher operational state

Productivity measures in logging involve simultaneous recognition and classification of event occurrence and timing, and the volume of stems being handled. In full-tree felling systems these measurements are difficult to implement in an autonomous manner because of the unfavorable working environment and the abundance of confounding extraneous events. This paper proposed a vision method that used a lowcost camera to recognize feller-buncher operational events including tree cutting and piling. It used a fine K-nearest neighbors (fKNN) algorithm as the final classifier based on both audio and video features derived from short video segments as inputs. The classifier’s calibration accuracy exceeds 94%. The trained model was tested on videos recorded under various conditions. The overall accurate rates for short segments were greater than 89%. Comparisons were made between the human- and algorithm derived event detection rates, events’ durations, and inter-event timing using continuously recorded videos taken during feller operation. Video results between the fKNN model and manual observation were similar. Statistical comparison using the Kolmogorov–Smirnov test to evaluate measured parameters’ distributions (manual versus automated event duration and inter-event timing) did not show significant differences with the lowest P-value among all Kolmogorov–Smirnov tests equal to 0.12. Here the result indicated the feasibility and potential of using the method for the automatic time study of drive-to-tree feller bunchers.

97 MATHEMATICS AND COMPUTING↗

Implications of Bioremediation of Polycyclic Aromatic Hydrocarbon-Contaminated Soils for Human Health and Cancer Risk

Background: Bioremediation uses microorganisms to degrade polycyclic aromatic hydrocarbons (PAHs) in contaminated soils. Its success is largely evaluated through targeted analysis of PAH concentrations in soil and cancer risk (exposure) estimates. However, bioremediation often fails to significantly degrade the most carcinogenic PAHs and can initiate formation of more polar metabolites, some of which may be more toxic. Objectives: We aimed to investigate whether the cancer risk associated with PAH-contaminated soils was reduced post-bioremediation and to identify the most effective bioremediation strategies for degrading the carcinogenic and high molecular weight (≥MW302) PAHs. Methods: Pre- and post-bioremediation concentrations of eight B2 group carcinogenic PAHs in soils were collated from the literature and used to calculate excess lifetime cancer risks (ELCR) for adult populations exposed via non-dietary ingestion, per current U.S. Environmental Protection Agency (USEPA) recommendations. Due to the nature of the collated data (reported as mean concentrations ± standard deviations pre- and post-bioremediation), we used simulation methods to reconstruct the datasets and enable statistical comparison of ELCR values pre- and post-bioremediation. Additionally, we measured MW302 PAHs in a contaminated soil prior to and following treatment in an aerobic bioreactor and examined their contributions to cancer risk. Results: 120 of 158 treated soils (76%) exhibited a statistically significant reduction in cancer risk following bioremediation; however, 67% (106/158) of soils had post-bioremediation ELCR values over 10 fold higher than the USEPA health-based ‘acceptable’ risk level. Composting treatments were most effective at biodegrading PAHs in soils and reducing the ELCR. MW302 PAHs were not significantly degraded during bioremediation and dibenzo(a,l)pyrene, alone, contributed an additional 35% to the cancer risk associated with the eight B2 group PAHs in the same bioremediated soil. Conclusions: Bioremediation strategies often fail to reduce carcinogenic PAH concentrations in contaminated soils below USEPA acceptable cancer risk levels. Additionally, MW302 PAHs and ‘unknown’ metabolites (compounds not routinely measured) are not included in current cancer risk assessments and could significantly contribute to soil carcinogenicity.

bioremediation↗

MO-G-201-01: A Multi-Institutional Study Investigating the Performance of a Knowledge-Based Planning System Against Pinnacle Auto-Planning Engine in SIB-IMRT for the Head-And-Neck Cancer

Purpose: Knowledge-based Planning (KBP) founded on prior planning experience and Auto-Planning Engine (APE; commercialized in Pinnacle v9.10 TPS) based on progressive optimization algorithm both aim to eliminate the trial-and-error process in radiotherapy inverse planning. This study investigates the performance of the approaches in a multi-institutional setting to evaluate their functionalities in oropharyngeal cancer and offers suggestions how they can be implemented in the clinic. Methods: Radboud University Medical Center (RUMC) provided 35 oropharyngeal cancer patients (SIB-IMRT with two-dose-level prescription: 68 Gy to PTV68 and 50.3 Gy to PTV50.3) with corresponding comparative APE plans. Johns Hopkins University (JHU) contributed to a three-dose-level (70 Gy 63 Gy and 58.1 Gy) plan library for RUMC’s patient KBP generation. MedStar Georgetown University Hospital (MGUH) contributed to a KBP approach employing overlap-volume histogram (OVH-KBP) for generating RUMC’s patient KBP plans using JHU’s plan library. Since both approaches need their own user-defined parameters as initial inputs the first 10 patients were set aside as training set to finalize them. Meanwhile cross-institutional comparisons and adjustments were implemented for investigating institutions’ protocol discrepancies and the approaches’ user-defined parameters were updated accordingly. The finalized parameters were then applied to the remaining 25 patients for OVH-KBP and APE generation. A Wilcoxon rank-sum test was used for statistical comparison with significance level of p<0.05. Results: On average PTV68’s V95 was 96.5% in APE plans vs. 97% in OVH-KBP plans (p=0.36); PTV50.3’s V95 in APE plans was 97.8% vs.97.6% in OVH-KBP plans (p=0.6); cord’s D0.1 cc was 38.6 Gy in OVH-KBP plans vs. 43.7 Gy in APE plans (p=0.0001); mean doses to larynxes oral cavities parotids and submandibular glands were similar with p>0.2. Conclusions: The study demonstrates that KBP and APE can generate plans of comparable quality in a multi-institutional setting. Variations in clinical protocols can be effectively addressed for cross-institutional adaptations. Binbin Wu and Todd McNutt are the co-inventors of a patent associated with the proposed knowledge-based planning system which was licensed to Varian Medical Systems in 2015; This research was in part supported by Philips Radiation Oncology Systems.

60 APPLIED LIFE SCIENCES↗

Comparison of wind speed measurements over the oceans with the Special Sensor Microwave/Imager and the Geosat altimeter

In order to compare wind speed estimates from the Geosat altimeter and the Special Sensor Microwave/Imager (SSM/I), 25 colocated passes, within 2 hours of each other, were selected and the SSM/I estimates of wind speed and atmospheric parameters extracted along the Geosat track. Both instruments and their algorithms are described. A statistical comparison of wind speed estimates is presented and the effects of the atmospheric parameters from Geosat are analyzed. Quasi-simultaneous measurements by Geosat and SSM/I, along a Geosat track in the North-East Pacific, are also presented.

Mognard, Nelly M.↗

Comparison of wind speed measurements over the oceans with the Special Sensor Microwave/Imager and the Geosat altimeter

In order to compare wind speed estimates from the Geosat altimeter and the Special Sensor Microwave/Imager (SSM/I), 25 colocated passes, within 2 hours of each other, were selected and the SSM/I estimates of wind speed and atmospheric parameters extracted along the Geosat track. Both instruments and their algorithms are described. A statistical comparison of wind speed estimates is presented and the effects of the atmospheric parameters from Geosat are analyzed. Quasi-simultaneous measurements by Geosat and SSM/I, along a Geosat track in the North-East Pacific, are also presented.

Mognard, Nelly M.↗

Comparison of winter-nocturnal geostationary satellite infrared-surface temperature with shelter-height temperature in Florida

Geostationary satellite surface temperatures derived from a Visible and Infrared Spin Scan Radiometer (VISSR) sensor (10.5 to 12.6 microns) were compared with 1.5-m air temperatures collected by a thermocouple on a traversing vehicle along rural highway transects in Florida, and with two fixed thermographs located in rural and agricultural areas. Statistical comparisons between satellite and 1.5-m observations yielded a mean correlation coefficient of 0.87 and an average sample standard deviation from regression of 1.57 C during clear nights for four winters (1978-1981). The satellite-temperature image of Lake Okeechobee was compared with its geographic outline for areal image registration. Manual overlays of temporal images were repeatable to within one pixel. Satellite-sensed water temperature of Lake Okeechobee was used as an indicator of satellite radiometer repeatability and stability.

Chen, E.↗

Graph Sampling for Visual Analytics

Effectively visualizing large graphs and capturing the statistical properties are two challenging tasks. To aid in these two tasks, many sampling approaches for graph simplification have been proposed, falling into three categories: node sampling, edge sampling, and traversal-based sampling. It is still unknown which approach is the best. We evaluate commonly used graph sampling methods through a combined visual and statistical comparison of graphs sampled at various rates. We conduct our evaluation on three graph models: random graphs, small-world graphs, and scale-free graphs. Initial results indicate that the effectiveness of a sampling method is dependent on the graph model, the size of the graph, and the desired statistical property. This benchmark study can be used as a guideline in choosing the appropriate method for a particular graph sampling task, and the results presented can be incorporated into graph visualization and analysis tools.

97 MATHEMATICS AND COMPUTING↗

CALIPSO IIR Version 2 Level 1b Calibrated Radiances: Analysis and Reduction of Residual Biases in the Northern Hemisphere

Version 2 of the Level 1b calibrated radiances of the Imaging Infrared Radiometer (IIR) on board the Cloud-Aerosol Lidar and Infrared Satellite Observation (CALIPSO) satellite has been released recently. This new version incorporates corrections of small but systematic seasonal calibration biases previously revealed in Version 1 data products mostly north of 30° N. These biases – of different amplitudes in the three IIR channels 8.65 µm (IIR1), 10.6 µm (IIR2), and 12.05 µm (IIR3) – were made apparent by a striping effect in images of IIR inter-channel brightness temperature differences (BTDs) and through seasonal warm biases of nighttime IIR brightness temperatures in the 30–60° N latitude range. The latter were highlighted through observed and simulated comparisons with similar channels of the Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Aqua spacecraft. To characterize the calibration biases affecting Version 1 data, a semi-empirical approach is developed, which is based on the in-depth analysis of the IIR internal calibration procedure in conjunction with observations such as statistical comparisons with similar MODIS/Aqua channels. Two types of calibration biases are revealed: an equalization bias affecting part of the individual IIR images and a global bias affecting the radiometric level of each image. These biases are observed only when the temperature of the instrument increases, and they are found to be functions of elapsed time since night-to-day transition, regardless of the season. Correction coefficients of Version 1 radiances could thus be defined and implemented in the Version 2 code. As a result, the striping effect seen in Version 1 is significantly attenuated in Version 2. Systematic discrepancies between nighttime and daytime IIR–MODIS BTDs in the 30–60° N latitude range in summer are reduced from 0.2 K in Version 1 to 0.1 K in Version 2 for IIR1–MODIS29. For IIR2–MODIS31 and IIR3–MODIS32, they are reduced from 0.4 K to close to zero, except for IIR3–MODIS32 in June, where the night-minus-day difference is around −0.1 K.

Garnier, Anne↗

Comparison of the information content of data from the Landsat-4 Thematic Mapper and the Multispectral Scanner

There has been a steady increase with respect to the available capability to monitor the earth's surface from satellite platforms. Developments regarding instrumentation should now be considered in the context of the possible commercialization of space systems. The satellite data user is to select his data with many variables in mind, including cost. The present investigation provides a statistical comparison of simultaneously acquired data from the Landsat-4 Thematic Mapper (TM) and the Multispectral Scanner (MSS) for five scenes acquired over agricultural areas. Simple examination of photographic products and manipulation and display of image data suggests that the utility of the TM data will be far greater than that of the MSS. However, factors of cost and frequency of observations can also be important. The approach employed in the investigation should facilitate evaluation of future remote sensing systems.

Price, J. C.↗

Retrieval of Aerosol Optical Depth Under Thin Cirrus from MODIS: Application to an Ocean Algorithm

A strategy for retrieving aerosol optical depth (AOD) under conditions of thin cirrus coverage from the Moderate Resolution Imaging Spectroradiometer (MODIS) is presented. We adopt an empirical method that derives the cirrus contribution to measured reflectance in seven bands from the visible to shortwave infrared (0.47, 0.55, 0.65, 0.86, 1.24, 1.63, and 2.12 μm, commonly used for AOD retrievals) by using the correlations between the top-of-atmosphere (TOA) reflectance at 1.38 micron and these bands. The 1.38 micron band is used due to its strong absorption by water vapor and allows us to extract the contribution of cirrus clouds to TOA reflectance and create cirrus-corrected TOA reflectances in the seven bands of interest. These cirrus-corrected TOA reflectances are then used in the aerosol retrieval algorithm to determine cirrus-corrected AOD. The cirrus correction algorithm reduces the cirrus contamination in the AOD data as shown by a decrease in both magnitude and spatial variability of AOD over areas contaminated by thin cirrus. Comparisons of retrieved AOD against Aerosol Robotic Network observations at Nauru in the equatorial Pacific reveal that the cirrus correction procedure improves the data quality: the percentage of data within the expected error +/-(0.03 + 0.05 ×AOD) increases from 40% to 80% for cirrus-corrected points only and from 80% to 86% for all points (i.e., both corrected and uncorrected retrievals). Statistical comparisons with Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) retrievals are also carried out. A high correlation (R = 0.89) between the CALIOP cirrus optical depth and AOD correction magnitude suggests potential applicability of the cirrus correction procedure to other MODIS-like sensors.

cirrus correction↗

SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

60 APPLIED LIFE SCIENCES↗