Search NASA⌕ Search

SEARCH · Search NASA

Results for “structural panels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

air-source heat pumps↗

Measured Performance and Analysis of Ground Source Heat Pumps for Space Conditioning and for Water Heating in a Low-Energy Test House Operated under Simulated Occupancy Conditions

In this paper we present measured performance and efficiency metrics of Ground Source Heat Pumps (GSHPs) for space conditioning and for water heating connected to a horizontal ground heat exchanger (GHX) loop. The units were installed in a 345m2 (3700ft2) high-efficiency test house built with structural insulated panels (SIPs), operated under simulated occupancy conditions, and located in Oak Ridge, Tennessee (USA) in US Climate Zone 4 . The paper describes distinctive features of the building envelope, ground loop, and equipment, and provides detailed monthly performance of the GSHP system. Space conditioning needs of the house were completely satisfied by a nominal 2-ton (7.0 kW) water-to-air GSHP (WA-GSHP) unit with almost no auxiliary heat usage. Recommendations for further improvement through engineering design changes are identified. The comprehensive set of data and analyses demonstrate the feasibility and practicality of GSHPs in residential applications and their potential to help achieve source energy and greenhouse gas emission reduction targets set under the IECC 2012 Standard.

efficiency↗

Whole House Mechanical Ventilation: A South Chicago Case Study

This case study describes a neighborhood of efficient, healthy, sustainable, affordable homes in South Chicago, IL, that feature structural insulated panels (SIPs), condensing furnaces, sealed combustion water heaters, and efficient lights and appliances.

affordable housing↗

DOE Zero Energy Ready Home Case Study: TC Legend Homes — Cedarwood, Bellingham, WA

This house was the Grand Winner in the Affordable Builder category of the 2014 Housing Innovation Awards, and has 6-inch SIP walls, a 10-inch structural insulated panel roof, and insulating concrete forms foundation walls with R-20 high-density rigid EPS foam under the slab.A single ductless heat pump heats and cools the home, which also gets passive solar heating from south-facing triple-pane windows that heat a concrete slab floor plus a connected greenhouse.

2014 housing innovation awards↗

DOE Zero Energy Ready Home Case Study: Leganza Residence - Greenbank, Washington

This case study describes a DOE Zero Energy Ready Home in Greenbank, Washington that scored HERS 37 without PV and a -5 with PV. This 1,955 ft2 custom home has 6.5-inch structural insulated panel (SIPs) walls, a 10.25-inch SIPS roof, an R-20 insulated slab, a 2-ton ground source heat pump, radiant floor heat, 7.1 kWh PV, and triple-pane windows.

builder↗

Building America Case Study: Columbia County Habitat for Humanity Passive Townhomes, Hudson, New York

Columbia County (New York) Habitat for Humanity built a pair of townhomes to Passive House criteria with the purpose of exploring approaches for achieving Passive House performance and to eventually develop a prototype design for future projects. The project utilized a 2x6 frame wall with a structural insulated panel curtain wall and a ventilated attic over a sealed OSB ceiling air barrier. Mechanical systems include a single head, wall mounted ductless mini-split heat pump in each unit and a heat recovery ventilator. Costs were $26,000 per unit higher for Passive House construction compared with the same home built to ENERGY STAR version 3 specifications, representing about 18 percent of total construction cost. This report discusses the cost components, energy modeling results and lessons from construction. Two alternative ventilation systems are analyzed: a central system; and, a point-source system with small through-wall units distributed throughout the house. The report includes a design and cost analysis of these two approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress in Hanford's Double-Shell Tank Integrity Project

The U.S. Department of Energy's Office of River Protection has an extensive integrity assessment program for the Hanford Site Double-Shell Tank System. The DOE Orders and environmental protection regulations provide the guidelines for the activities used to inspect and maintain 28 double-shell tanks (DSTs), the waste evaporator, and ancillary equipment that compose this system. This program has been reviewed by oversight and regulatory bodies and found to comply with the established guidelines. The basis for the DOE Order 435.1-1 for tank integrity comes from the Tank Structural Integrity Panel led by Brookhaven National Laboratory during the late 1990's. These guidelines established criteria for performing Non-Destructive Examination (NDE), for acceptance of the NDE results, for waste chemistry control, and for monitoring the tanks. The environmental regulations mirror these requirements and allow for the tank integrity program to provide compliant storage of the tanks. Both sets of requirements provide additional guidance for the protection of ancillary equipment. CH2M HILL uses two methods of NDE: visual inspection and Ultrasonic Testing (UT). The visual inspection program examines the primary tank and secondary liner of the DST. The primary tank is examined both on the interior surface above the waste in the tank and on the exterior surface facing the annulus of the DST. The interior surface of the tank liner is examined at the same time as the outer surface of the primary tank. The UT program examines representative areas of the primary tank and secondary liner by deploying equipment in the annulus of the tank. Both programs have led to the development of new equipment for remote inspection of the tanks. Compact camera and enhanced lighting systems have been designed and deployed through narrow access ports (called risers) into the tanks. The UT program has designed two generations of crawlers and equipment for deployment through risers into the thermally hot and radioactive environment. Also extensions were developed to allow inspection of the tank's curve upper (haunch) and lower (knuckle) surfaces. CH2M HILL primarily maintains chemistry control of the DST by ensuring that the concentrations of hydroxide and nitrite ions are favorable with respect to the nitrate ion concentration in the waste. This control program is supported by an extensive sampling program that obtains samples from the supernatant and solid layers in the tank to ensure compliance with the chemical specification. At DOE direction, CH2M HILL has embarked on a waste chemistry optimization program to enhance the protection of the tank surface and the understanding of the parameters that affect general and localized corrosion in the tanks. Over the past decade, DOE has deployed Electrochemical Noise corrosion probes in the DST to monitor localized corrosion. From the information gathered as part of the chemistry control, new information has been identified about the parameters requiring control to ensure tank integrity. CH2M HILL is deploying a series of corrosion probes to test and employ these parameters to provide real time corrosion monitoring of the DSTs. (authors)

42 ENGINEERING↗

PROGRESS IN HANFORDS DOUBLE SHELL TANK (DST) INTEGRITY PROJECT

The U.S. Department of Energy's Office of River Protection has an extensive integrity assessment program for the Hanford Site Double-Shell Tank System. The DOE Orders and environmental protection regulations provide the guidelines for the activities used to inspect and maintain 28 double-shell tanks (DSTs), the waste evaporator, and ancillary equipment that compose this system. This program has been reviewed by oversight and regulatory bodies and found to comply with the established guidelines. The basis for the DOE Order 435.1-1 for tank integrity comes from the Tank Structural Integrity Paneled by Brookhaven National Laboratory during the late 1990s. These guidelines established criteria for performing Non-Destructive Examination (NDE), for acceptance of the NDE results, for waste chemistry control, and for monitoring the tanks. The environmental regulations mirror these requirements and allow for the tank integrity program to provide compliant storage of the tanks. Both sets of requirements provide additional guidance for the protection of ancillary equipment. CH2M HILL uses two methods of NDE: visual inspection and Ultrasonic Testing (UT). The visual inspection program examines the primary tank and secondary liner of the DST. The primary tank is examined both on the interior surface above the waste in the tank and on the exterior surface facing the annulus of the DST. The interior surface of the tank liner is examined at the same time as the outer surface of the primary tank. The UT program examines representative areas of the primary tank and secondary liner by deploying equipment in the annulus of the tank. Both programs have led to the development of new equipment for remote inspection of the tanks. Compact camera and enhanced lighting systems have been designed and deployed through narrow access ports (called risers) into the tanks. The UT program has designed two generations of crawlers and equipment for deployment through risers into the thermally hot and radioactive environment. Also extensions were developed to allow inspection of the tank's curve upper (haunch) and lower (knuckle) surfaces. CH2M HILL primarily maintains chemistry control of the DST by ensuring that the concentrations of hydroxide and nitrite ions are favorable with respect to the nitrate ion concentration in the waste. This control program is supported by an extensive sampling program that obtains samples from the supernatant and solid layers in the tank to ensure compliance with the chemical specification. At DOE direction, CH2M HILL has embarked on a waste chemistry optimization program to enhance the protection of the tank surface and the understanding of the parameters that affect general and localized corrosion in the tanks. Over the past decade, DOE has deployed Electrochemical Noise corrosion probes in the DST to monitor localized corrosion. From the information gathered as part of the chemistry control, new information has been identified about the parameters requiring control to ensure tank integrity. CH2M HILL is deploying a series of corrosion probes to test and employ these parameters to provide real time corrosion monitoring of the DSTs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hypersonic Fluid–Structure Interaction on a Cone–Slice–Ramp Geometry

In this study, fluid–structure interactions were measured between a representative control surface and the hypersonic flow deflected by it. The control surface is simplified as a spanwise finite ramp placed on a longitudinal slice of a cone. The front surface of the ramp contains a thin panel designed to respond to the unsteady fluid loading arising from the shock-wave/boundary-layer interactions. Experiments were conducted at Mach 5 and Mach 8 with ramps of different angles. High-speed schlieren captured the unsteady flow dynamics and accelerometers behind the thin panel measured its structural response. Panel vibrations were dominated by natural modes that were excited by the broadband aerodynamic fluctuations arising in the flowfield. However, increased structural response was observed in two distinct flow regimes: 1) attached or small separation interactions, where the transitional regime induced the strongest panel fluctuations. This was in agreement with the observation of increased convective undulations or bulges in the separation shock generated by the passage of turbulent spots, and 2) large separated interactions, where shear layer flapping in the laminar regime produced strong panel response at the flapping frequency. In addition, panel heating during the experiment caused a downward shift in its natural mode frequencies.

33 ADVANCED PROPULSION SYSTEMS↗

High Velocity Joining of Multi-material Stacks Containing 3rd Generation Advanced High-Strength Stainless Steel and Aluminum Extrusion and Casting (Abstract)

Advanced lightweight materials, including multi-phase steels, aluminum extrusions and aluminum castings, have increasingly replaced mild steel to meet original equipment manufacturer (OEM) demand for increased fuel economy and crash-safety requirements. Third Generation (Gen 3) AHSS provides a superior combination of strength and ductility for crash energy management components in the vehicle body-in-white (BIW). Aluminum extrusions are widely used for bumper, door rocker panel, cradle and battery frame applications. Aluminum castings are increasingly being used in electric vehicles to provide part consolidation, weight saving and increased driving range. Rocker panels are, for example, an important component of the battery electric vehicle (BEV) body structure. The rocker panel serves several purposes, including structural support, crash resistance, protection for the vehicle's underbody and battery tray, and contributing to the overall aesthetics. In order to reduce weight, rocker panels are usually constructed using outer panels consisting of 3rd generation advanced high strength steels (AHSS) and an inner multicell aluminum extrusion structure for energy absorption which protects the batteries in a crash event. It is well known, however, that these material combinations provide significant challenges for joining and are susceptible to liquid metal embrittlement and loss of strength. The overall goal is to find a solution that addresses these challenges in order to produce multi-material vehicle components with reduced weight and minimal galvanic and recyclability issues. The approach being proposed here is to utilize a novel high velocity (HiVe) riveting and clinching technique recently demonstrated by Pacific Northwest National Laboratory (PNNL) to join (2T/3T) sheets of aluminum alloys and steel. This process will not only address the aforementioned challenges but also help significantly reduce the joining cycle time. This work will also demonstrate use of HiVe assemblies to be retrofitted to existing body-shop robots thus having minimal impact to existing body shop operations.

36 MATERIALS SCIENCE↗

A Fluid Solver for Studying Torsional Galloping in Solar-Tracking PV Panel Arrays

Solar-tracking photovoltaic arrays are susceptible to aeroelastic fluttering during high-wind events. This dynamic fluttering behavior can grow in amplitude until the panels enter an unstable mode known as torsional galloping which can lead to panel failure or total array destruction. To better understand the physics of the torsional galloping phenomenon, and to inform the discussion around panel design and recommended panel stow positions during high wind events, a fluid-structure interaction solver composed of a simulated atmospheric boundary layer with simplified panel structural responses was designed. The simulation choices and features of this solver were informed by the geometry and physical properties of an experimental panel array known to exhibit torsional galloping behavior during hind-wind events. These simulations revealed that the torsional galloping instability is driven by a combination of cyclic vortex shedding from the sun-facing side of the panel and the elastic properties of the torque tube linking the panel assemblies. Testing different stow angles across a range of wind speeds indicates that panels are generally more stable when stowed at negative angles where the leading edge is closer to the ground, hypothesized to be due to ground-blocking effects.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Power generation study of luminescent solar concentrator greenhouse

A Luminescent Solar Concentrator (LSC) greenhouse and an identical control greenhouse were constructed with photovoltaic (PV) cells attached to the roof panels of both structures. The placement and types of PV cells used in the LSC panels were varied for performance comparisons. Solar power generation was monitored continuously for one year, with leading LSC panels exhibiting a 37% increase in power production compared to the reference. The 22.3 m 2 greenhouse was projected to generate a total of 1342 kWh per year, or 57.4 kWh/m 2 if it were composed solely of the leading panel of Criss Cross panel design. The LSC panels also showed no signs of degradation throughout the trial demonstrating the material's robustness in field conditions.

14 SOLAR ENERGY↗

An Evaluation of Frangible Materials as Veneers on Vented Structural Member Designs

Literature shows there has been extensive research and testing done in the area of wall panels and frangible materials. There is evidence from past research that shows it is possible to vent a structure that has had an accidental internal explosion [1]. The reviewed literature shows that most designs vent the entire wall panel versus a frangible material attached to the wall panel. The frangible material attachment points are important to determine the overall loading of the wall panel structure [2]. The materials used in the reviewed literature were securely attached as well as strong enough to remain intact during the pressure loading to move the entire wall panel. Since the vented wall panel was the weakest part of the overall structure, the other walls of the structure were substantially larger. The structure was usually built from concrete and large amounts of steel with dirt and sand over the top of the structure.The study will be conducted at Sandia National Laboratories located in Albuquerque New Mexico. The skeletal structural design for evaluation is a rectangular frame with a square grid pattern constructed from steel. The skeletal structure has been given to the researcher as a design requirement. The grid pattern will be evaluated strictly on plastic deformation and the loading that is applied from the frangible material. The frangible material tested will either fit into the grid or will be a veneer lightly attached to the structure frame. The frangible material may be required on both sides of the structure to adequately represent the application.

36 MATERIALS SCIENCE↗

Fluid-Structure Interactions using Controlled Disturbances on a Slender Cone in Hypersonic Flow

Fluid-structure interactions were studied on a 7° half-angle cone in the Sandia Hypersonic Wind Tunnel at Mach 8 over a range of freestream Reynolds numbers between 3.3 and 14.5 × 10 6 /m. A thin panel with tunable structural natural frequencies was integrated into the cone and exposed to naturally developing boundary layers. An elevated panel response was measured during boundarylayer transition at frequencies corresponding to the turbulent burst rate, and lower vibrations were measured under a turbulent boundary layer. Controlled perturbations from an electrical discharge were then introduced into the boundary layer at varying frequencies corresponding to the structural natural frequencies of the panel. The perturbations were not strong enough to drive a panel response exceeding that due to natural transition. Instead at high repetition rates, the perturber modified the turbulent burst rate and intermittency on the cone and therefore changed the conditions for when an elevated transitional panel vibration response occurred. Studies were also conducted in the Boeing/AFOSR Mach 6 Quiet Tunnel at Purdue University. Under quiet flow, natural transition does not occur, and the controlled perturbations are the only disturbance source. A clear panel response to turbulent spots created by the controlled perturbations was observed at varying frequencies of spot generation. The quiet-flow measurements confirm the clear relationship between turbulent spot passage and panel vibration.

42 ENGINEERING↗

Hanford single-shell tank sidewall coring Project - 15548

As part of an enhanced Single-Shell Tank (SST) integrity project, Washington River Protection Solutions, the US DOE Hanford site Tank Operations Contractor, established an expert panel to provide recommendations for implementation of the project. In one of the main areas of interest, structural integrity, the panel recommended obtaining and testing a vertical core from the entire depth of the sidewall for SSTs that have leaked and have been operated at high temperatures for extended periods. Due to concerns over handling contaminated samples, the panel later recommended that the evaluation focus only on thermal degradation. SST 241-A-106 was selected as the best choice for sidewall coring based on heat exposure and other factors. During site preparation activities, nondestructive testing and evaluation of the exposed tank dome and sidewall was performed using impact echo, spectral analysis of surface waves, and sonic echo/impulse response acoustic wave test methods. Good results were observed in the tests performed on the dome, but results were inconclusive for the full wall height due to signal damping. Results indicated that no cracking was predicted in the upper wall. Sidewall coring of tank A-106 was completed over two weeks in May 2014. Over 38 feet of concrete core was successfully removed, to a depth approximately halfway through the tank footing. Nondestructive and destructive physical testing of the concrete core specimens was successfully performed and included visual examination and determination of transverse and longitudinal resonant frequency and dynamic modulus of elasticity; pulse velocity; static modulus of elasticity; Poisson's ratio; and compressive strength. The testing indicated favorable results with values generally greater, and in many cases significantly greater, than expected in comparison with the values originally specified and those used in the current structural analysis of record. Petrographic analysis was performed to assess the quality and condition of the concrete and the extent of any deterioration or deleterious reactions occurring within the concrete, and determined that the concrete within the examined core segments is in overall good condition, with a minor amount of microcracking and minor evidence of deleterious mechanisms that do not appear to have significantly affected the overall quality and integrity of the concrete. The results of the testing performed on the concrete core removed from the sidewall of SST 241-A-106 do not reveal any deficiencies with the structural integrity of the tank. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structure, function, and inhibition of drug reactivating human gut microbial β-glucuronidases

Bacterial β-glucuronidase (GUS) enzymes cause drug toxicity by reversing Phase II glucuronidation in the gastrointestinal tract. While many human gut microbial GUS enzymes have been examined with model glucuronide substrates like p-nitrophenol-β-D-glucuronide (pNPG), the GUS orthologs that are most efficient at processing drug-glucuronides remain unclear. Here we present the crystal structures of GUS enzymes from human gut commensals Lactobacillus rhamnosus, Ruminococcus gnavus , and Faecalibacterium prausnitzii that possess an active site loop (Loop 1; L1) analogous to that found in E. coli GUS, which processes drug substrates. We also resolve the structure of the No Loop GUS from Bacteroides dorei. We then compare the pNPG and diclofenac glucuronide processing abilities of a panel of twelve structurally diverse GUS proteins, and find that the new L1 GUS enzymes presented here process small glucuronide substrates inefficiently compared to previously characterized L1 GUS enzymes like E. coli GUS. We further demonstrate that our GUS inhibitors, which are effective against some L1 enzymes, are not potent towards all. Our findings pinpoint active site structural features necessary for the processing of drug-glucuronide substrates and the inhibition of such processing.

60 APPLIED LIFE SCIENCES↗