Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Charge-distribution effect of imaging molecular structure by high-order above-threshold ionization

Using a triatomic molecular model, we show that the interference pattern in the high-order above-threshold ionization (HATI) spectrum depends dramatically on the charge distribution of the molecular ion. Therefore the charge distribution can be considered a crucial factor for imaging a molecular geometric structure. Based on this study, a general destructive interference formula for each above-threshold ionization channel is obtained for a polyatomic molecule concerning the positions and charge values of each nuclei. Comparisons are made for the HATI spectra of CO{sub 2}, O{sub 2}, NO{sub 2}, and N{sub 2}. These results may shed light on imaging complex molecular structure by the HATI spectrum.

74 ATOMIC AND MOLECULAR PHYSICS↗

Extending the ICRF to Higher Radio Frequencies: Imaging and Source Structure

We present imaging results and source structure analysis of extragalactic radio sources observed using the Very Long Baseline Array (VLBA) at 24 GHz and 43 GHz as part of an ongoing NASA, USNO, NRAO and Bordeaux Observatory collaboration to extend the International Celestial Reference Frame (ICRF) to higher radio frequencies. The K/Q-band image database now includes images of 108 sources at 43 GHz (Q-braid) and images of 230 sources at 24 GHz (K-band). Preliminary analysis of the observations taken to date shows that the sources are generally more compact as one goes from the ICRF frequency of 8.4 GHz to 24 GHz. This result is consistent with the standard theory of compact extragalactic radio sources and suggests that reference frames defined at these higher radio frequencies will be less susceptible to the effects of intrinsic source structure than those defined at lower frequencies.

Boboltz, David A.↗

SU-F-18C-15: Model-Based Multiscale Noise Reduction On Low Dose Cone Beam Projection

Purpose: To improve image quality of low dose cone beam CT for patient positioning in radiation therapy. Methods: In low dose cone beam CT (CBCT) imaging systems, Poisson process governs the randomness of photon fluence at x-ray source and the detector because of the independent binomial process of photon absorption in medium. On a CBCT projection, the variance of fluence consists of the variance of noiseless imaging structure and that of Poisson noise, which is proportional to the mean (noiseless) of the fluence at the detector. This requires multiscale filters to smoothen noise while keeping the structure information of the imaged object. We used a mathematical model of Poisson process to design multiscale filters and established the balance of noise correction and structure blurring. The algorithm was checked with low dose kilo-voltage CBCT projections acquired from a Varian OBI system. Results: From the investigation of low dose CBCT of a Catphan phantom and patients, it showed that our model-based multiscale technique could efficiently reduce noise and meanwhile keep the fine structure of the imaged object. After the image processing, the number of visible line pairs in Catphan phantom scanned with 4 ms pulse time was similar to that scanned with 32 ms, and soft tissue structure from simulated 4 ms patient head-and-neck images was also comparable with scanned 20 ms ones. Compared with fixed-scale technique, the image quality from multiscale one was improved. Conclusion: Use of projection-specific multiscale filters can reach better balance on noise reduction and structure information loss. The image quality of low dose CBCT can be improved by using multiscale filters.

60 APPLIED LIFE SCIENCES↗

Radial image transfer by cylindrical, step-index optical waveguides

The theoretical extent of image transfer by perfect, cylindrical, step-index optical waveguides is examined. Azimuthal image structure is essentially removed by such waveguides, while substantial radial image structure is transmitted. The consequences of this behavior for optical-fiber image scramblers are discussed; such devices may be unsuitable for simple photometric applications but appear to be potentially useful in reducing zonal errors in slit spectroscopy.

Heacox, William D.↗

Imaging Coherent Structural Dynamics with Ultrafast Electron Microscopy

Development of ultrafast electron and X-ray scattering methods has enabled direct routes to probing atomic-scale structural dynamics. This in turn has led to new insight into lattice responses to a variety of dynamic processes associated with phase transformations, electron-lattice correlations, and nanoscale mechanical motion, to name a few. Presently, the most wide-spread approaches involve using table-top, laser-driven electron-scattering chambers or femtosecond (fs) X-ray beamlines to probe dynamics in reciprocal space and, in many instances, over specimen regions that are large relative to unit-cell dimensions and discrete (atomic and nanoscale) structural and morphological defects (e.g., vacancies, line and screw dislocations, grain boundaries, interfaces, etc.). As a result, the transients monitored for relatively large-spot-size reciprocal-space measurements – typically some aspect of a Bragg reflection (intensity, position, width, shape) – may be comprised of a range of responses occurring within the probed region. To directly resolve the role of distinct morphologies and structural features on dynamics associated with the nucleation, emergence, evolution, and decay of coherent phenomena, one would ideally directly image the local, nanoscale behaviors and precisely correlate responses to the nature of the feature. Here, I will show how such effects can be directly probed with ultrafast electron microscopy (UEM). After a brief overview of the operating principles of UEM, I will discuss how we are using real-space imaging to directly visualize coherent structural dynamics in a variety of nanostructured and nanoscale materials.

47 OTHER INSTRUMENTATION↗

WUS324: Multiscale Full Waveform Inversion Approaching Convergence Improves Waveform Fits While Imaging Seismic Structure of the Western United States

Abstract We report a new model of radially anisotropic crustal and upper mantle structure of the western United States (WUS324) obtained from full waveform inversion of earthquake data. We ran three multiscale inversion stages beyond model WUS256 (Rodgers et al., 2022, https://doi.org/10.1029/2022jb024549 ) allowing them to approach convergence to fit a larger data set to a shorter minimum period of 16 s. WUS324 is based on 324 total iterations from its starting model, significantly more (16 times) than previous studies. Waveform misfit reductions are 66%–70% for both the inversion data and an independent validation data set providing confidence in the predictive power of the model. WUS324 provides much better fits and reveals shear wavespeed, v S , structure of this large region with more detail than previous waveform tomography models. We show representative images demonstrating the resolution of diverse seismic structure across this highly heterogeneous region including oceanic lithosphere, subducting slabs and continental magmatism.

58 GEOSCIENCES↗

Imaging the inside of thick structures using cosmic rays

The authors present here a new method to image reinforcement elements inside thick structures and the results of a demonstration measurement performed on a mock-up wall built at Los Alamos National Laboratory. The method, referred to as “multiple scattering muon radiography”, relies on the use of cosmic-ray muons as probes. The work described in this article was performed to prove the viability of the technique as a means to image the interior of the dome of Florence Cathedral Santa Maria del Fiore, one of the UNESCO World Heritage sites and among the highest profile buildings in existence. Its result shows the effectiveness of the technique as a tool to radiograph thick structures and image denser object inside them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise-gating to Clean Astrophysical Image Data

I present a family of algorithms to reduce noise in astrophysical images and image sequences, preserving more information from the original data than is retained by conventional techniques. The family uses locally adaptive filters (“noise gates”) in the Fourier domain to separate coherent image structure from background noise based on the statistics of local neighborhoods in the image. Processing of solar data limited by simple shot noise or by additive noise reveals image structure not easily visible in the originals, preserves photometry of observable features, and reduces shot noise by a factor of 10 or more with little to no apparent loss of resolution. This reveals faint features that were either not directly discernible or not sufficiently strongly detected for quantitative analysis. The method works best on image sequences containing related subjects, for example movies of solar evolution, but is also applicable to single images provided that there are enough pixels. The adaptive filter uses the statistical properties of noise and of local neighborhoods in the data to discriminate between coherent features and incoherent noise without reference to the specific shape or evolution of those features. The technique can potentially be modified in a straightforward way to exploit additional a priori knowledge about the functional form of the noise.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared Chemical Nano-Imaging: Accessing Structure, Coupling, and Dynamics on Molecular Length Scales

This Perspective highlights recent advances in infrared vibrational chemical nano-imaging. In its implementations of scattering scanning near-field optical microscopy (s-SNOM) and photothermal-induced resonance (PTIR), IR nanospectroscopy provides few-nanometer spatial resolution for the investigation of polymer, biomaterial, and related soft-matter surfaces and nanostructures. Broad-band IR s-SNOM with coherent laser and synchrotron sources allows for chemical recognition with small-ensemble sensitivity and the potential for sensitivity reaching the single-molecule limit. Probing selected vibrational marker resonances, it gives access to nanoscale chemical imaging of composition, domain morphologies, order/disorder, molecular orientation, or crystallographic phases. Local intra- and intermolecular coupling can be measured through frequency shifts of a vibrational marker in heterogeneous environments and associated inhomogeneities in vibrational dephasing. In combination with ultrafast spectroscopy, the vibrational coherent evolution of homogeneous sub-ensembles coupled to their environment can be observed. Outstanding challenges are discussed in terms of extensions to coherent and multidimensional spectroscopies, implementation in liquid and in situ environments, general sample limitations, and engineering s-SNOM scanning probes to better control the nano-localized optical excitation and to increase sensitivity.

Environmental Molecular Sciences Laboratory↗

Addressing Critical Problems in Materials Science Through Multiscale and Multimode Characterization (Project 1); Characterization and Optimization of Novel Triple-Conducting Oxide Materials for Energy Applications (Project 2) (CRADA Final Report)

PROJECT 1: Address critical problems in materials science and simultaneously advance the state-of-the-art in multiscale and multimode characterization using the combined advanced analytical capabilities and expertise of Colorado School of Mines (CSM) and the National Renewable Energy Laboratory (NREL). The primary effort of the Phase I of this CRADA is to establish the International Center for Multiscale Characterization using shared resources at both NREL and CSM. Phase II will focus on capability development and marketing, choosing candidate materials science issues in the areas of structure imaging, chemical composition mapping, and correlating properties and performance of materials for impact in energy-related, environmental and critical materials areas. The CRADA will be modified to include specific topics of concern in materials science to industry member partners. Advanced analytical capabilities and expertise at CSM and NREL will be used to advance materials understanding and performance through characterization of multiscale phenomena including structural imaging, chemical composition mapping, and other techniques correlating properties and performance of materials. PROJECT 2: As part of the International Center for Materials Characterization, work under Modification #1 will be led by Colorado School of Mines (CSM), working in collaboration with NREL staff to mentor and advise CSM postdoctoral researchers on set up of diffusion annealing experiments. The purpose of the modification is to provide for NREL staff to mentor and advise CSM postdoctoral researchers on set up of diffusion annealing experiments, including mentoring and advising the CSM-NREL team on proper Secondary Ion Mass Spectrometry (SIMS) data analysis as needed. SIMS measurements of 10-20 samples will be performed at NREL during the project duration.

08 HYDROGEN↗

STUDIES OF NGC 6720 WITH CALIBRATED HST/WFC3 EMISSION-LINE FILTER IMAGES. I. STRUCTURE AND EVOLUTION ,

We have performed a detailed analysis of the Ring Nebula (NGC 6720) using Hubble Space Telescope WFC3 images and derived a new three-dimensional model. Existing high spectral resolution spectra played an important supplementary role in our modeling. It is shown that the Main Ring of the nebula is an ionization-bounded irregular non-symmetric disk with a central cavity and perpendicular extended lobes pointed almost toward the observer. The faint outer halos are determined to be fossil radiation, i.e., radiation from gas ionized in an earlier stage of the nebula when it was not ionization bounded. The narrowband WFC3 filters that isolate some of the emission lines are affected by broadening on their short wavelength side and all the filters were calibrated using ground-based spectra. The filter calibration results are presented in an appendix.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of nanotomographic images for structure analysis of carbonate rocks

Carbonate rocks store more than 50% of world's petroleum. These rocks' structures are highly complex and vary depending on many factors regarding their formation, e.g., lithification and diagenesis. In order to perform an effective extraction of petroleum it is necessary to know petrophysical parameters, such as total porosity, pore size and permeability of the reservoir rocks. Carbonate rocks usually have a range of pore sizes that goes from nanometers to meters or even dozen of meters. The nanopores and micropores might play an important role in the pores connectivity of carbonate rocks. X-ray computed tomography (CT) has been widely used to analyze petrophysical parameters in recent years. This technique has the capability to generate 2D images of the samples' inner structure and also allows the 3D reconstruction of the actual analyzed volume. CT is a powerful technique, but its results depend on the spatial resolution of the generated image. Spatial resolution is a measurement parameter that indicates the smallest object that can be detected. There are great difficulties to generate images with nanoscale resolution (nanotomographic images). In this work three carbonate rocks, one dolomite and two limestones (that will be called limestone A and limestone B) were analyzed by nanotomography. The measurements were performed with the SkyScan2011 nanotomograph, operated at 60 kV and 200 μA to measure the dolomite sample and 40 kV and 200 μA to measure the limestone samples. Each sample was measured with a given spatial resolution (270 nm for the dolomite sample, 360 nm for limestone A and 450 nm for limestone B). The achieved results for total porosity were: 3.09 % for dolomite, 0.65% for limestone A and 3.74% for limestone B. This paper reports the difficulties to acquire nanotomographic images and further analysis about the samples' pore sizes.

36 MATERIALS SCIENCE↗

Dynamic super-resolution structured illumination imaging in the living brain

Cells in the brain act as components of extended networks. Therefore, to understand neurobiological processes in a physiological context, it is essential to study them in vivo. Super-resolution microscopy has spatial resolution beyond the diffraction limit, thus promising to provide structural and functional insights that are not accessible with conventional microscopy. However, to apply it to in vivo brain imaging, we must address the challenges of 3D imaging in an optically heterogeneous tissue that is constantly in motion. We optimized image acquisition and reconstruction to combat sample motion and applied adaptive optics to correcting sample-induced optical aberrations in super-resolution structured illumination microscopy (SIM) in vivo. Lastly, we imaged the brains of live zebrafish larvae and mice and observed the dynamics of dendrites and dendritic spines at nanoscale resolution.

60 APPLIED LIFE SCIENCES↗

Deep learning of structural morphology imaged by scanning X-ray diffraction microscopy

Scanning X-ray nanodiffraction microscopy is a powerful technique for spatially resolving nanoscale structural morphologies by diffraction contrast. One of the critical challenges in experimental nanodiffraction data analysis is posed by the convergence angle of nanoscale focusing optics which creates simultaneous dependency of the far-field scattering data on three independent components of the local strain tensor-corresponding to dilation and two potential rigid body rotations of the unit cell. All three components are in principle resolvable through a spatially mapped sample tilt series; however, traditional data analysis is computationally expensive and prone to artifacts. In this study, we implement NanobeamNN, a convolutional neural network specifically tailored to the analysis of scanning probe X-ray microscopy data. NanobeamNN learns lattice strain and rotation angles from simulated diffraction of a focused X-ray nanobeam by an epitaxial thin film and can directly make reasonable predictions on experimental data without the need for additional fine-tuning. We demonstrate that this approach represents a significant advancement in computational speed over conventional methods, as well as a potential improvement in accuracy over the current standard.

Luo, Aileen [Cornell Univ., Ithaca, NY (United Sta↗

Imaging Antenna Structure For Submillimeter Wavelengths

Integrated-circuit antenna structure contains two-dimensional array of antennas and antenna reflectors. In receiving mode, each antenna acts as part of detector for one picture element in millimeter- or submillimeter-wavelength imaging radar system. Millimeter-wave imaging system used to view objects through fog, smoke, or smog with resolution intermediate between microwave and visible-light imaging systems. Antenna elements, supports, and reflectors made by integrated-circuit techniques. Structures fabricated on front and back substrates separately. Substrates then joined. Inexpensive way to provide large number of small antenna elements required for imaging, all mounted rigidly in way that does not degrade operation.

Rebeiz, G.↗

3D Imaging with Structured Illumination for Advanced Security Applications

Three-dimensional (3D) information in a physical security system is a highly useful discriminator. The two-dimensional data from an imaging systems fails to provide target distance and three-dimensional motion vector, which can be used to reduce nuisance alarm rates and increase system effectiveness. However, 3D imaging devices designed primarily for use in physical security systems are uncommon. This report discusses an architecture favorable to physical security systems; an inexpensive snapshot 3D imaging system utilizing a simple illumination system. The method of acquiring 3D data, tests to understand illumination design, and software modifications possible to maximize information gathering capability are discussed.

42 ENGINEERING↗

X-ray scattering based scanning tomography for imaging and structural characterization of cellulose in plants

X-ray and neutron scattering have long been used for structural characterization of cellulose in plants. Due to averaging over the illuminated sample volume, these measurements traditionally overlooked the compositional and morphological heterogeneity within the sample. Here, a scanning tomographic imaging method is described, using contrast derived from the X-ray scattering intensity, for virtually sectioning the sample to reveal its internal structure at a resolution of a few micrometres. This method provides a means for retrieving the local scattering signal that corresponds to any voxel within the virtual section, enabling characterization of the local structure using traditional data-analysis methods. This is accomplished through tomographic reconstruction of the spatial distribution of a handful of mathematical components identified by non-negative matrix factorization from the large dataset of X-ray scattering intensity. Joint analysis of multiple datasets, to find similarity between voxels by clustering of the decomposed data, could help elucidate systematic differences between samples, such as those expected from genetic modifications, chemical treatments or fungal decay. The spatial distribution of the microfibril angle can also be analyzed, based on the tomographically reconstructed scattering intensity as a function of the azimuthal angle.

36 MATERIALS SCIENCE↗

Imaging doped silicon test structures using low energy electron microscopy.

This document is the final SAND Report for the LDRD Project 105877 - 'Novel Diagnostic for Advanced Measurements of Semiconductor Devices Exposed to Adverse Environments' - funded through the Nanoscience to Microsystems investment area. Along with the continuous decrease in the feature size of semiconductor device structures comes a growing need for inspection tools with high spatial resolution and high sample throughput. Ideally, such tools should be able to characterize both the surface morphology and local conductivity associated with the structures. The imaging capabilities and wide availability of scanning electron microscopes (SEMs) make them an obvious choice for imaging device structures. Dopant contrast from pn junctions using secondary electrons in the SEM was first reported in 1967 and more recently starting in the mid-1990s. However, the serial acquisition process associated with scanning techniques places limits on the sample throughput. Significantly improved throughput is possible with the use of a parallel imaging scheme such as that found in photoelectron emission microscopy (PEEM) and low energy electron microscopy (LEEM). The application of PEEM and LEEM to device structures relies on contrast mechanisms that distinguish differences in dopant type and concentration. Interestingly, one of the first applications of PEEM was a study of the doping of semiconductors, which showed that the PEEM contrast was very sensitive to the doping level and that dopant concentrations as low as 10{sup 16} cm{sup -3} could be detected. More recent PEEM investigations of Schottky contacts were reported in the late 1990s by Giesen et al., followed by a series of papers in the early 2000s addressing doping contrast in PEEM by Ballarotto and co-workers and Frank and co-workers. In contrast to PEEM, comparatively little has been done to identify contrast mechanisms and assess the capabilities of LEEM for imaging semiconductor device strictures. The one exception is the work of Mankos et al., who evaluated the impact of high-throughput requirements on the LEEM designs and demonstrated new applications of imaging modes with a tilted electron beam. To assess its potential as a semiconductor device imaging tool and to identify contrast mechanisms, we used LEEM to investigate doped Si test structures. In section 2, Imaging Oxide-Covered Doped Si Structures Using LEEM, we show that the LEEM technique is able to provide reasonably high contrast images across lateral pn junctions. The observed contrast is attributed to a work function difference ({Delta}{phi}) between the p- and n-type regions. However, because the doped regions were buried under a thermal oxide ({approx}3.5 nm thick), e-beam charging during imaging prevented quantitative measurements of {Delta}{phi}. As part of this project, we also investigated a series of similar test structures in which the thermal oxide was removed by a chemical etch. With the oxide removed, we obtained intensity-versus-voltage (I-V) curves through the transition from mirror to LEEM mode and determined the relative positions of the vacuum cutoffs for the differently doped regions. Although the details are not discussed in this report, the relative position in voltage of the vacuum cutoffs are a direct measure of the work function difference ({Delta}{phi}) between the p- and n-doped regions.

36 MATERIALS SCIENCE↗