At least 73 records · Page 4

Q-18: Advanced System Development Fact Sheet

Q-18 provides Systems and Design Engineering for Future Weapons Systems and Technology up to Phase 3 or 6.3 with emphasis on improved performance, safety, produceability and agility of the future stockpile. The group regulars engages and partners with DoD customers, NNSA as well as other divisions across the LANL campus including to complete its mission. The group is forward leaning and provides Future System and System Agnostic Design and System Engineering support to a wide range of experiments from internally fielded technology tests to hydrodynamic and subcritical experiments including fabrication for small component level to full scale prototypes and test articles, test article assembly, and mechanical and electrical design.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

HEU Metal Delayed Critical Experiments with 10 to 19 Inch Thick Graphite Reflectors

Approximately 100 graphite-reflected highly enriched uranium (HEU, 93.14 wt % 235 U) metal annular and cylindrical critical experiments were performed in the early 1960s at the Oak Ridge Critical Experiments Facility (ORCEF). This report presents details from experiment logbooks, experimental data sheets and the author's memory for 44 HEU metal (93.14 wt % 235 U) critical assemblies with graphite reflectors varying from 10 to 19 in. thick, outside diameters varying from 7 to 15 in., inside diameters varying from 7 to 13 in. and critical HEU metal masses varying from 20.4 to 69.0 kg. The data from the 44 experiments described in this report are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Evaluation Program (ICSBEP) once the uncertainty analysis on the measured k eff is completed. Based on previous ICSBEP benchmarks with this HEU metal at ORCEF, the uncertainties in the measured k eff are expected to be as low as ±0.0004. Preparation of this report is part of an effort at Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented series of critical and subcritical experiments enumerated in Critical and Subcritical NEA Benchmark Possibilities for Measurements at ORCEF and Other US DOE Facilities (Mihalzo, ORNL/TM-2019/1188, 2019) and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities. More than 500 operational days of critical facility time were used, not including setup and dismantlement time. This documentation for a part of one series of graphite reflected highly enriched uranium metal critical experiments, that used 50 operational days of ORCEF time, was performed using funding received from the DOE Office of Nuclear Energy’s Nuclear Energy University Programs at the University of Tennessee Nuclear Engineering Department. This documentation was also supported by the Nuclear Criticality, Radiation Transport, and Safety programs at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Criticality Experiments Research Center (NCERC) - capabilities and recent measurements

The National Criticality Experiments Research Center (NCERC) located at the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS) and operated by Los Alamos National Laboratory (LANL) is home to four critical assemblies which are used to support of range of missions, including nuclear criticality safety and nuclear nonproliferation. Additionally, subcritical systems can also be assembled at NCERC. NCERC is providing critical and subcritical experiments valuable to the nuclear data community and experiments performed at NCERC are often published as benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. This manuscript will give a broad overview of recent experiments performed at NCERC, upcoming experiments, and why integral measurements are important and useful to the nuclear data community. The four critical assemblies are GODIVA IV, FLATTOP, COMET, and PLANET. GODIVA IV is a cylindrical metal fast burst reactor, the fourth in the GODIVA series that dates back to the 1950’s. FLATTOP is an highly enriched uranium (HEU) or Pu core reflected by natural uranium. COMET and PLANET are vertical lift assemblies, where one half of the reactor can be lifted to the upper half of the reactor to create a critical system. Some recent experiments include various critical intermediate energy assemblies with lead, and subcritical measurements of plutonium reflected by copper, tungsten, and nickel. Work is also underway to make a better measurement of the critical mass of neptunium, using a neptunium sphere surrounded by nickel shells. Additionally, measurements will be performed next year with HEU shells from Rocky Flats. These HEU shells will be stacked together to make larger systems, allowing for a large range of criticality (from subcritical to delayed critical). Other upcoming measurements include an HEU critical assembly sensitive to intermediate energy neutrons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Sensitivity-based Similarity Metrics for New Experiment Design Optimization

The nuclear data used in advanced reactor simulations requires validation. Data from nuclear criticality experiments can provide this validation. New nuclear criticality experiment design requires extensive knowledge and expert judgement such that the experimental design parameters are selected in such a way to keep the experiment subcritical. To aide in this experimental design process, professionals can utilize sensitivity and uncertainty analysis. Sensitivity and uncertainty analysis relies on matching new application experiments with currently existing benchmark experiments. Currently, there is functionality in the Whisper 1.1 software package to calculate a similarity metric based on neutron multiplication factor sensitivity coefficients between a new application designed by the user and existing International Criticality Safety Benchmark Experiment Project (ICSBEP) benchmarks. The Whisper 1.1 software package is included in Monte Carlo N-Particle ® Code Version 6.21 (MCNP ® 6.2). This work is geared toward expanding this capability to new similarity metrics based on beta-effective sensitivity coefficients and reactivity coefficient sensitivity coefficients. While the investigation of these sensitivity coefficients is presented in detail in separate works at this same conference, this work will be primarily focused on studying the similarity metrics in more detail. These similarity metrics will then be incorporated into the optimization algorithms used for experiment design in EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data), which is a Los Alamos National Laboratory (LANL) project designed to constrain nuclear data of interest, such that adjustments can be made to possible inaccuracies. A more detailed optimization can be subsequently performed by breaking down these similarity metrics by isotope, reaction, and energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Analysis of Neutron Multiplicity Counting Statistics Using First-Order Perturbation Theory and Application to a Subcritical Plutonium Metal Benchmark

It is frequently important to estimate the uncertainty and sensitivity of measured and computed detector responses in subcritical experiments and simulations. These uncertainties arise from the physical construction of the experiment, uncertainties in the transport parameters, and counting uncertainties. Perturbation theory enables sensitivity analysis (SA) and uncertainty quantification on integral quantities like detector responses. Here the aim of our work is to apply SA to the statistics of subcritical neutron multiplicity counting distributions. Current SA methods have only been applied to mean detector responses and the keff eigenvalue. For multiplicity counting experiments, knowledge of the higher-order counting moments and their uncertainties are essential for a complete SA. We apply perturbation theory to compute the sensitivity of neutron multiplicity counting moments to arbitrarily high order. Each moment is determined by solving an adjoint transport equation with a source term that is a function of the adjoint solutions for lower-order moments. This enables moments of arbitrarily high order to be sequentially determined, and it shows that each moment is sensitive to the uncertainties of all lower-order moments. To close our SA of the moments, we derive forward transport equations that are functions of the forward flux and lower-order moment adjoint fluxes. We verify our calculations for the first three moments by comparison with multiplicity counting measurements of a subcritical plutonium metal sphere. For the first three moments, the most influential parameters are ranked, and the validity of first-order perturbation theory is demonstrated by examining the series truncation error. This enables a detailed SA of subcritical multiplicity counting measurements of fissionable material based on transport theory.

42 ENGINEERING↗

Validation and Independent Uncertainty Analysis of the MIX-SOL-THERM-003 ICSBEP Benchmark

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) was started in 1992 by the United States Department of Energy and later in 1995 became an international project with contributions from 22 countries. The project is now organized by the OECD (Organisation for Economic Co-operation and Development) Nuclear Energy Agency (NEA). In its most recent iteration, the ICSBEP handbook contains over five thousand evaluations of critical, near-critical, and subcritical experiments conducted in facilities all around the world. These benchmarks serve as valuable information for criticality safety engineers who can use them to validate calculation techniques and establish minimum subcritical margins for operations with fissionable materials. The benchmarks in the handbook are categorized by their fissile material composition, material form (oxide, solution, or metal), and fission energy spectra. This is especially useful for those looking for benchmarks similar to a system they are working on to compare methods and identify trends. The ICSBEP Handbook Uncertainty Guide is document outlining recommended practices and methods for determining uncertainties in these benchmarks. Quantifying these uncertainties thoroughly is crucial as it allows a higher degree of confidence that data used from them is valid and relevant. The guide stresses the importance of a thorough and well documented uncertainty analysis when evaluating an experiment. All measured values of a system, whether they be dimensions or material compositions, have a certain amount of uncertainty associated with them and can be analyzed one by one to determine their effects on the system. Many evaluated benchmarks in the handbook present this in detail, however some do not, mostly earlier evaluations performed in the 1990’s and early 2000’s. Recently at Los Alamos National Laboratory (LANL), the Nuclear Criticality Safety Division (NCSD) of LANL has been validating MCNP6.2 ® input files of criticality benchmarks for use by Whisper, a criticality safety code developed at LANL. This effort is also part of the OECD NEA Working Party on International Nuclear Data Evaluation Co-operation (WPEC) Subgroup 45, also known as Validation of Nuclear Data Libraries (VaNDaL). The goal of VaNDaL is to compile a set of validated simulation inputs for use in validating nuclear data and simulation codes. As part of these efforts, one of the benchmarks reviewed was the MIX SOL-THERM-003 ICSBEP benchmark. This paper provides an independent uncertainty analysis of this benchmark experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the CERBERUS Evaluation for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook

Modeling & Simulation (M&S) tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers continue to improve, we are able to enhance resolution in our calculations. Therefore, the limitations of simulation capability are in the quality of data that is being used, including our ability to quantify the uncertainty and sensitivity of that data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. These experiments, along with differential measurements, can help improve the quality of nuclear data. Concerns regarding the accuracy of Cu nuclear data have been published. The large values and trend of C-E for the Zeus intermediate energy benchmark, being one of the primary examples. Furthermore, very few experiments have been designed to be sensitive to Cu (as shown in Figure 1), so an integral, critical experiment is needed to help resolve these differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of HEU-Pb in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook

The Department of Energy invests tens of millions of dollars each year to develop the next generation of nuclear engineering modeling & simulation (M&S) tools. These tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers become more powerful, we are able to enhance resolution in our calculations. This improved resolution is taking us to a point where the limitations of simulation capability are in the quality of data, including our ability to quantify the uncertainty and sensitivity of the data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. Thus, M&S tools need evaluated and quality-assured experimental data for validation purposes. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross-section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. Figure 1 organizes all the benchmark evaluations that have been performed by the isotope of interest, in this case Pb, and the average neutron energy the system. Compared to other isotopes of interest for nuclear applications, there are few benchmark evaluations for Pb systems. The lack of integral measurements to determine errors in Pb cross-section data has caused the latest nuclear cross-section libraries to over/underestimate k eff compared to experimental results. Therefore, this evaluation fills an important knowledge gap in benchmark evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How can a diverse set of integral and semi-integral measurements inform identification of discrepant nuclear data?

Nuclear data are used for a variety of applications, including criticality safety, reactor performance, and material safeguards. Despite the breadth of use-cases, the effective neutron multiplication factor, keff, of ICSBEP critical assemblies are primarily used for nuclear data validation; these are sensitive to specific energy regions and nuclides and are unable to uniquely constrain nuclear data. As a consequence, general-purpose nuclear data libraries, such as ENDF/B-VIII.0, may have deficiencies that, while not apparent in criticality applications, negatively impact other applications, such as non-destructive analysis of special nuclear material and neutron diagnosed subcritical experiments. Recent work by the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project developed a machine learning tool, RAFIEKI, which uses random forests and the SHAP metric to determine which nuclear data contribute most to predicted bias between measured and simulated responses (e.g. keff). This paper contrasts RAFIEKI analysis applied to keff only against RAFIEKI analysis with keff paired with either LLNL pulsed sphere measurements or subcritical benchmarks. Two examples show that a) including pulsed sphere measurements substantially increases 9Be nuclear data importance to bias between 2 and 15 MeV, and b) including subcritical benchmarks has the potential for disentangling compensating errors between 240Pu (n,el) and (n,il) cross-sections between 0.1 and 10 MeV. These results show that RAFIEKI analysis applied to response sets that include, but go beyond, keff can aid nuclear data evaluators in identifying issues in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

2013 Predictive Science Panel Meeting Summary Report

The Predictive Science Panel (PSP) met at LANL on 12-14 March 2013. The Panel appreciated the frank and open discussion of some very difficult issues with which LANL is grappling with. The meeting consisted of four related deep-dive sessions: (1) Certification – Strategies and challenges for Reuse; (2) Certification – The impact of Pu aging; (3) Certification – The role of subcritical experiments; (4) Certification – First campaigns for MaRIE 1.0 There was also discussion of LLNL’s feedback from the October 2012 report and a poster session featuring excellent work by early-career scientists and engineers.

97 MATHEMATICS AND COMPUTING↗

Models for HEU objects in the NDSE IV and III series

A Neutron-Diagnosed Subcritical Experiment (NDSE) proof-of-principle setup exists at area-11 in Nevada. An exquisite set of gamma-ray flux die-away data has been obtained at this facility for a number of highly-enriched uranium (HEU) objects, including objects referred to as IV, IV', IV'' (the object IV series), IIIa, and IIIb (the object III series). These objects are constructed via a set of hemi-spherical concentric HEU shells (known as the Rocky Flats shells), surrounded by a sphere of aluminum (Al), encased in an outer sphere of high-density polyethylene (HDP). The “as built” detailed MCNP-calculated k eff values obtained by Goorley, for the object IV and III series, are listed in Table II. These model calculations contain detailed information about the inner and outer radii and masses of each hemi-shell used to make each of the objects. Objects IV', and IV'' were obtained by replacing inner HEU shells with Al. The low k eff of object IIIa was obtained by substituting a single HEU shell, with an inner radius of ~5 cm, with an Al shell. For object IIIb the substitution was a little further out but only in one hemi-shell. Except for the inner most shell (ball), all HEU shells have a thickness close to 0.333 cm. Previously the k eff of objects IV', IV'', IIIa, and IIIb, were determined from measured gamma ray die-away data via an analysis using a simple modification of the density of the HEU in our simple three layered model (HEU, Al, and HDP) of object IV including the outer safety can. This was done to see the quality of the inference and investigate any limitations associated with not using detailed information about the known perturbations used to make these objects. In this work, we built models (priors) of objects IV', IV'', IIIa, and IIIb that make use of our knowledge about the nature of the perturbations. With these models, instead of adjusting the density of the HEU in our object IV model to match the data from objects IV', IV'', IIIa, and IIIb, as done previously, we will be able to (in future studies) adjust r AL , and r i to infer the k eff of the corresponding objects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

(U) Endpoint Energy and Scintillator Geometry Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy Radiography

High-energy radiography is used to image imploding materials to better understand weapon design and performance. The Enhanced Capabilities for Subcritical Experiments (ECSE) is a new facility proposal that aims to collect radiographic images of nuclear material. As part of the facility design, we aim to optimize data quality and radiographic performance by investigating different detector designs. We addressed design decisions by simulating different scintillator designs using M CNP6 and calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(O)). First, we investigated the effects of the x-ray endpoint energy on the detector response. We generated three x-ray spectra with endpoint energies of 20 MeV, 22 MeV, and 24 MeV. The three raw spectra were filtered using the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) line-of-sight materials along with 1) flat field filtration using 7 cm tungsten alloy in the bullnose and 2) an FTO with 4 plates. The scatter-to-direct radiation ratio was much larger for FTO with 4 plates (50-60%) compared to the flat field with 7 cm of bullnose material (8%). We used these filtered spectra to calculate the detector response for the original DARHT segmented scintillator design. We found that the endpoint energy and filtration had a negligible effect on the detector response. The quantum efficiency was 0.63, the Swank factor was 0.84, and the DQE(O) was 0.53 for all six spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NDSE Static Series V & VI Test Results

The purpose for the Neutron-Diagnosed Subcritical Experiment (NDSE) Static Test Series at the Nevada National Security Site (NNSS) Area 11 is to develop and validate the capability to make precise and accurate measurements of k eff for Special Nuclear Material (SNM) targets with k eff ~ 0.95.1 The series has now completed six sets of measurements using the deuterium-tritium (DT) Dense Plasma Focus (DPF) neutron source, with a Rocky-Flats-Shells Highly Enriched Uranium (RF HEU) target, to measure the gamma die-away to this purpose. The last of these series, Series V and VI, are the subject of this report. Both series were performed on a target comprised of the Object IV HEU + CH 2 configuration, which is identical to Object II but with smaller DPF collimators that limit the incident neutron flux to the HEU radius.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nimble Feedthrough Qualification - 125% High Explosive Overpressure Test Plan RevA

The primary purpose of this High Explosive (HE) Over-Pressure Test (OPT) is to qualify top cover diagnostic feedthroughs that will be used on LLNL Nimble Subcritical Experiment (SCE) Series designs per experimental design verification requirements specified in ASME Boiler and Pressure Vessel Code Case 2564, Impulsively-Loaded Pressure Vessels, Section VIII, Division 3; and to satisfy the over-test requirement of DOE-STD-1212. The diagnostic feedthroughs are part of the Vessel Confinement System (VCS), which is credited as a Safety Significant Design Feature per the U1a Facility Documented Safety Analysis (DSA). The OPT will be conducted at the LANL Area 1, R306 Firing Site (TA-15-R306) in a 3-foot diameter VCS depicted in Figure 1.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Impact of Changes in ENDF/B-VII.1 and ENDF/B-VIII.0 235U Nuclear Data Indicated by NDSE Studies on LLNL Pulsed Sphere Simulations

A recent journal article by J.A. Gomez et al. measured gamma-ray die-off curves of three subcritical static highly-enriched uranium (HEU) assemblies driven by an external neutron source with a new detector system. This new detector system was developed for being used in dynamically driven subcritical assemblies as part of the Neutron Diagnosed Subcritical Experiments (NDSE) program. Simulations of these die-off curves with various nuclear data and comparison to experimental data indicated that a decrease of the ENDF/B-VII.1 235 U(n,inl) cross section by a factor 0.8 and 0.85 for ENDF/B-VIII.0 would lead to better predictions of experimental data. Here, we test the proposed changes with another type of measurement response, namely neutron-leakage spectra emitted in LLNL pulsed sphere measurements. These spheres were pulsed by 14-MeV neutrons produced via the D+T reaction in their center. The proposed changes in nuclear data have a distinctly smaller impact on predicting pulsed-sphere neutron-leakage spectra than for the die-off curves; they lead to a worsened prediction of the inelastic valley of LLNL pulsed-sphere neutron spectra indicating that the proposed change could constitute a compensating error. Changes in the inelastic angular distributions along with the cross section might be worthwhile to study