Mirror Measurement Device

A Small Business Innovation Research (SBIR) contract led to a commercially available instrument used to measure the shape profile of mirror surfaces in scientific instruments. Bauer Associates, Inc.'s Bauer Model 200 Profilometer is based upon a different measurement concept. The local curvature of the mirror's surface is measured at many points, and the collection of data is computer processed to yield the desired shape profile. (Earlier profilometers are based on the principle of interferometry.) The system is accurate and immune to problems like vibration and turbulence. Two profilometers are currently marketed, and a third will soon be commercialized.

Source record↗

Measurement and image processing evaluation of surface modifications of dental implants G4 pure titanium created by different techniques

Foreign substances and organic tissue interaction placed into the jaw in order to eliminate tooth loss involves a highly complex process. Many biological reactions take place as well as the biomechanical forces that influence this formation. Osseointegration denotes to the direct structural and functional association between the living bone and the load-bearing artificial implant's surface. Taking into consideration of the requirements in the manufacturing processes of the implants, surface characterizations with high precise measurement techniques are investigated and thus long-term success of dental implant is emphasized on the importance of these processes in this study. In this research, the detailed surface characterization was performed to identify the dependence of the manufacturing techniques on the surface properties by using the image processing methods and using the scanning electron microscope (SEM) for morphological properties in 3D and Taylor Hobson stylus profilometer for roughness properties in 2D. Three implant surfaces fabricated by different manufacturing techniques were inspected, and a machined surface was included into the study as a reference specimen. The results indicated that different surface treatments were strongly influenced surface morphology. Thus 2D and 3D precise inspection techniques were highlighted on the importance for surface characterization. Different image analyses techniques such as Dark-light technique were used to verify the surface measurement results. The computational phase was performed using image processing toolbox in Matlab with precise evaluation of the roughness for the implant surfaces. The relationship between the number of black and white pixels and surface roughness is presented. FFT image processing and analyses results explicitly imply that the technique is useful in the determination of surface roughness. The results showed that the number of black pixels in the image increases with increase in surface roughness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time effect of erosion by solid particle impingement on ductile materials

Erosion and morphological studies of several metals and alloys eroded by normal impingement jets of spherical glass beads and angular crushed-glass erodent particles were conducted. Erosion morphology (the width, depth, and width-depth ratio of the pit) was studied in order to fully investigate the effect of time on erosion rate. The eroded surfaces were studied with a scanning electron microscope, and surface profiles were measured with a profilometer. A large amount of experimental data reported in the literature was also analyzed in order to understand the effect of variables such as the type of device, the erodent particle size and shape, the impact velocity, and the abrasive charge on erosion-rate-versus-time curves. In the present experiments the pit-width-versus-time or pit-depth-versus-time curves were similar to erosion-versus-time curves for glass-bead impingement. The pit-depth-rate-versus-time curves were similar to erosion-rate-versus-time curves for crushed-glass impingement. Analysis of experimental data with two forms of glass resulted in four types of erosion-rate-versus-time curves: (1) incubation, acceleration, and steady-state periods (type I), (2) incubation, acceleration, deceleration, and steady-state periods (type III), (3) incubation, acceleration, peak rate, and deceleration periods (type IV), and (4) incubation, acceleration, steady-state, and deceleration periods (type V).

Rao, P. V.↗

Effect of electric discharge machining on the fatigue life of Inconel 718

The effect of electric discharge machining on the fatigue life of Inconel 718 alloy at room temperature was investigated. Data were generated in the uniaxial tension fatigue mode at ambient temperature using flat 3.175 mm thick specimens. The specimens were machined on a wire-cut electric discharge machine at cutting speeds ranging from 0.5 to 2 mm per minute. The specimens were fatigued at a selected stress, and the resulting fatigue lives compared with that of the virgin material. The surfaces of the fatigued specimens were examined under optical and scanning electron microscopes, and the roughness of the surfaces was measured using a standard profilometer. From the results of the investigation, it was concluded that the fatigue life of the specimens machined using EDM decreased slightly as compared with that of the virgin material, but remained unchanged as the cutting speed was changed. The results are explained using data produced employing microhardness measurements, profilometry, and optical and scanning microscopy.

Jeelani, S.↗

Projected-Fringe Profilometer Maps Erosion Of Electrode

Report describes use of projected-fringe, phase-stepping optical profilometer to measure three-dimensional shape of surface of molybdenum electrode eroded in ion engine. Instrumentation used in these measurements similar to that described in "Projected-Fringe, Phase-Stepping Profilometer" (LEW-14996).

Macrae, Gregory S.↗

Defect Density Comparison of Detached versus Attached Bridgman Grown Germanium Crystals

Semiconductor Bridgman growth without contact between the growing crystal and the growth ampoule has been observed on Earth in the last few years during several experiments. Previously, this so-called detached or dewetted growth phenomenon occurred preferentially under microgravity conditions due to the absence of the hydrostatic pressure. Many theoretical as well as experimental investigations helped to provide a better understanding of the mechanism and to identify the parameters leading to the detachment. Thus, recent attempts to get stable detached growth under terrestrial conditions by Duffar et al. growing III-V compounds and our own group with germanium and germanium-silicon alloys were frequently successful. At this conference we present the results of several germanium growth experiments performed in pyrolytic boron nitride containers. To exert an influence on the pressure ratio above and below the melt we used closed-bottom and open-bottom containers. This resulted in mainly detached-grown single crystals with the closed-bottom crucibles and attached single crystals with the open-bottom tubes. Evidence of detached growth is obtained from the crystal surface with a combination of axial profilometer scans and optical and electron microscopy. Detailed investigations of the defect structure, which is the main focus of this presentation, have shown an improvement of the crystal quality in the detached-grown samples, with a strong reduction of the etch pit density by about two orders of magnitude.

Schweizer, M.↗

Detached Growth of Germanium by Directional Solidification

Detached crystal growth technique (dewetting) offers improvement in the quality of the grown crystals by preventing sticking to the walls of the crucible and thus reducing the possibility of parasitic nucleation and formation of lattice defects upon cooling. One of the factors relevant for the phenomena is the pressure differential across the meniscus at the crystal-melt interface. We investigated this effect experimentally. The growth took place in closed ampoules under the pressure of an inert gas (forming gas: 96% Ar + 4% H2). The pressure above the melt was adjustable and allowed for a control of the pressure difference between the top and bottom menisci. The crystals were characterized, particularly by taking profilometer measurements along the grown crystals surface. The effects of the experimental conditions on the detachment were compared with those predicted based on the theory of Duffar et al.

Palosz, W.↗

Wear-Resistance Investigations on Ceramic Coatings for Lunar Dust Mitigation

Lunar dust has posed a major challenge to exploration efforts due to abrasion and impact. This work focuses on fundamental studies on ceramic coatings as candidates for enhanced resistance to impact and wear. As a first step, standard and modified approaches to the method of abrasion testing were explored for options to incorporate lunar regolith as wear media, the effects of which were presented for AL6061-T6 control samples. Following this, wear results for air plasma-sprayed (APS) alumina coatings were investigated due to their superior strength and surface hardness. In addition, APS 8 wt % yttria-stabilized zirconia (8YSZ) coatings were studied for their strength and martensitic transformation toughness. Measurements were made by assessing the mass loss, with a standard scale at various intervals. In addition, surface roughness was measured with a profilometer and features identified with a high-resolution microscope. The findings demonstrated that wear media has a distinct effect on the abrasion. The alumina coatings demonstrated improved wear over 8YSZ. However, the tailorability of 8YSZ makes it an attractive option to continue to modify as a wear-resistant coating to protect against lunar dust abrasion. The results of these measurements provide insight into the wear behavior of future directions in candidate ceramic coatings for the harsh lunar environment.

ceramic coatings↗

Wear-Resistance Investigations on Ceramic Coatings for Lunar Dust Mitigation

Lunar dust has posed a major challenge to exploration efforts due to abrasion and impact. This work focuses on fundamental studies on ceramic coatings as candidates for enhanced resistance to impact and wear. As a first step, standard and modified approaches to the method of abrasion testing were explored for options to incorporate lunar regolith as wear media, the effects of which were presented for AL6061-T6 control samples. Following this, wear results for air plasma-sprayed (APS) alumina coatings were investigated due to their superior strength and surface hardness. In addition, APS 8 wt % yttria-stabilized zirconia (8YSZ) coatings were studied for their strength and martensitic transformation toughness. Measurements were made by assessing the mass loss, with a standard scale at various intervals. In addition, surface roughness was measured with a profilometer and features identified with a high-resolution microscope. The findings demonstrated that wear media has a distinct effect on the abrasion. The alumina coatings demonstrated improved wear over 8YSZ. However, the tailorability of 8YSZ makes it an attractive option to continue to modify as a wear-resistant coating to protect against lunar dust abrasion. The results of these measurements provide insight into the wear behavior of future directions in candidate ceramic coatings for the harsh lunar environment.

ceramic coatings↗

In-situ Diagnostic for Assessing Hall Thruster Wear

The design of a new diagnostic to measure the net erosion of Hall thruster surfaces is presented. This diagnostic consists of a pair of optical noncontact profilometer pens mounted to a set of motion stages, which can interrogate the surface features of multiple components of interest including the hollow cathode assembly, magnet front pole covers, and discharge channel. By comparing scans of these surfaces to reference features, estimates of the component erosion rates can be acquired throughout long-duration lifetime tests without venting and removing the thruster from the vacuum facility for external profilometry. This work presents a detailed overview of the diagnostic design including the precision positioning system. In addition, preliminary data are shown which verify diagnostic operation and establish a baseline that will be used to track the erosion of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) during an ongoing long-duration wear test.

Ahern, Drew M.↗

Mode I tensile fracture behavior of adhesively-bonded metal–metal, metal–CFRP, and CFRP–CFRP bi-material combinations analyzed by size effect method

Understanding the adhesive and interfacial fracture is important for developing and achieving better adhesive jointing in bi-materials, the location which becomes less vulnerable in engineered structure components. Still, to characterize the fracturing behavior of various adhesively-bonded materials, it was shown in this work that the Mode I fracture energies estimated from conventional methods (e.g., work-of-fracture, (modified) compliance calibration method, (modified) beam theory, etc.) can be strongly affected by adherent thickness, adhesive bond length, and material type. Consequently, this hindered the proper understanding of fracturing in adhesive jointing of bi-materials since the estimated fracture energies can exhibit unreasonable difference among various material combinations, thus leading to the confusion in the literature due to the unfair comparison on these non-objective results estimated by leveraging conventional methods on the specimens with different geometries. This work compared size effect method with conventional methods on the calculation of the Mode I fracture energies of metal-metal, metal-CFRP, and CFRP-CFRP material combinations via Double Cantilever Beam (DCB) tests. The results showed that the estimated fracture energies of various material combinations are not dependent on the specimen geometries. This aspect allowed the fair comparison particularly on the interfacial fracturing between metal/adhesive and CFRP/adhesive, and the difference was further explained and correlated with the damage morphology on the material surface after failure identified through three-dimensional profilometer.

36 MATERIALS SCIENCE↗

Modification on surface oxide layer structure and surface morphology of niobium by gas cluster ion beam treatments

Recently, it was demonstrated that significant reductions in field emission on Nb surfaces could be achieved by means of a new surface treatment technique called gas cluster ion beam (GCIB). Further study as shown in this paper revealed that GCIB treatments could modify surface irregularities and remove surface asperities leading to a smoother surface finish as demonstrated through measurements using a 3D profilometer, an atomic force microscope, and a scanning electron microscope. These experimental observations were supported by computer simulation via atomistic molecular dynamics and a phenomenological surface dynamics. Measurements employing a secondary ion mass spectrometry found that GCIB could also alter Nb surface oxide layer structure. Possible implications of the experimental results on the performance of Nb superconducting radio frequency cavities treated by GCIB will be discussed. First experimental results on Nb single cell superconducting radio frequency cavities treated by GCIB will be reported.

36 MATERIALS SCIENCE↗

In-Situ Diagnostic for Assessing Hall Thruster Wear

The design of a new diagnostic to measure the net erosion of Hall thruster surfaces is presented. This diagnostic consists of a pair of optical non-contact profilometer pens mounted to a set of motion stages, which can interrogate the surface features of multiple components of interest including the hollow cathode assembly, magnet front pole covers, and discharge channel. By comparing scans of these surfaces to reference features, estimates of the component erosion rates can be acquired throughout long-duration lifetime tests without venting and removing the thruster from the vacuum facility for external profilometry. This work presents a detailed overview of the diagnostic design including the precision positioning system. In addition, preliminary data are shown which verify diagnostic operation and establish a baseline that will be used to track the erosion of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) during an ongoing long-duration wear test.

Ahern, Drew M.↗

In-Situ Diagnostic for Assessing Hall Thruster Wear

The design of a new diagnostic to measure the net erosion of Hall thruster surfaces is presented. This diagnostic consists of a pair of optical non-contact profilometer pens mounted to a set of motion stages, which can interrogate the surface features of multiple components of interest including the hollow cathode assembly, magnet front pole covers, and discharge channel. By comparing scans of these surfaces to reference features, estimates of the component erosion rates can be acquired throughout long-duration lifetime tests without venting and removing the thruster from the vacuum facility for external profilometry. This work presents a detailed overview of the diagnostic design including the precision positioning system. In addition, preliminary data are shown which verify diagnostic operation and establish a baseline that will be used to track the erosion of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) during an ongoing long-duration wear test.

Ahern, Drew M.↗

Radial Profilometry

Radial profilometry is combination of optical and electronic techniques for measurement of inner surfaces of cylindrical or nearly cylindrical cavities. Profilometer inserted in pipe or other cavity to measure its shape optically. Illumination supplied through optical fiber, and image of inspected area of cavity transmitted through bundle of optical fibers. Applications include inspection of pipes, tubes, boreholes, and possibly measurements of contours in blood vessels or other internal organs.

Gilbert, J. A.↗

Bridgman Growth of Detached GeSi Crystals

The growth of detached crystals by the Bridgman technique, in which the growing crystal is not in contact with the crucible wall, has been observed both on earth and in microgravity conditions. Such detachment has particularly been in evidence in microgravity experiments, where the pressure head of the molten sample is absent. At present, the mechanisms contributing to the detachment are not completely understood and until recently detachment has not been reproducibly obtained. Key parameters which must be considered are the contact angle between the melt and the crucible and the growth angle. Another essential parameter is the pressure difference between the annular gap around the solid below the melt and the volume above the melt. Here we present results of the growth of Ge(0.98)Si(0.02) using adjustments in the applied temperature profile to control the pressure difference between the bottom and top of the melt. The technique is less susceptible to sample contamination than controlling the pressure by connecting the crucible to external gas sources. Using this technique, a pressure difference is created by decreasing the temperature in the volume above the melt while the sample is molten but prior to growth. A maximum pressure difference approximately equal to the pressure head of the molten sample can thus be obtained. Several GeSi crystals were grown in pyrolitic boron nitride crucibles. When a pressure difference was applied, samples were reproducibly grown mostly detached. For comparison, samples were also grown in a configuration in which gas could pass freely between the gap below the melt and the volume above the melt and no pressure difference could be established. These samples were initially attached. Existence of detachment was determined both by measuring the radius of the samples with a profilometer and by observations of the sample surfaces with optical and electron microscopy. The gap thickness between the crucible and detached crystal was on the order of 10 micron. The surfaces of the attached areas of the crystals had the same shape as the interior crucible wall whereas in the detached areas the crystal facets could usually be observed.

Volz, M. P.↗

Radius of Curvature Measurement of Large Optics Using Interferometry and Laser Tracker

The determination of radius of curvature (ROC) of optics typically uses either a phase measuring interferometer on an adjustable stage to determine the position of the ROC and the optics surface under test. Alternatively, a spherometer or a profilometer are used for this measurement. The difficulty of this approach is that for large optics, translation of the interferometer or optic under test is problematic because of the distance of translation required and the mass of the optic. Profilometry and spherometry are alternative techniques that can work, but require a profilometer or a measurement of subapertures of the optic. The proposed approach allows a measurement of the optic figure simultaneous with the full aperture radius of curvature.

Hagopian, John↗

A comparison between measured surface microtopography and observed scattering in the extreme ultraviolet

The paper presents comparative measurements of surface roughness on prepared samples. These measurements have been made with both Talystep profilometers and WYKO interferometers. In addition, the scattering distribution from these samples was measured at extreme ultraviolet wavelengths. The utility of the WYKO interferometer and Talystep device for specifying extreme ultraviolet mirror surface quality is discussed.