Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchronized sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Asynchronous timing and Doppler recovery in DSP based DPSK modems for fixed and mobile satellite applications

While conventional analog modems employ some kind of clock wave regenerator circuit for synchronous timing recovery, in sampled modem receivers the timing is recovered asynchronously to the incoming data stream, with no adjustment being made to the input sampling rate. All timing corrections are accomplished by digital operations on the sampled data stream, and timing recovery is asynchronous with the uncontrolled, input A/D system. A good timing error measurement algorithm is a zero crossing tracker proposed by Gardner. Digital, speech rate (2400 - 4800 bps) M-PSK modem receivers employing Gardner's zero crossing tracker were implemented and tested and found to achieve BER performance very close to theoretical values on the AWGN channel. Nyguist pulse shaped modem systems with excess bandwidth factors ranging from 100 to 60 percent were considered. We can show that for any symmetric M-PSK signal set Gardner's NDA algorithm is free of pattern jitter for any carrier phase offset for rectangular pulses and for Nyquist pulses having 100 percent excess bandwidth. Also, the Nyquist pulse shaped system is studied on the mobile satellite channel, where Doppler shifts and multipath fading degrade the pi/4-DQPSK signal. Two simple modifications to Gardner's zero crossing tracker enable it to remain useful in the presence of multipath fading.

Koblents, B.↗

Effects of square-wave and simulated natural light-dark cycles on hamster circadian rhythms

Circadian rhythms of activity (Act) and body temperature (Tb) were recorded from male Syrian hamsters under square-wave (LDSq) and simulated natural (LDSN, with dawn and dusk transitions) light-dark cycles. Light intensity and data sampling were under the synchronized control of a laboratory computer. Changes in reactive and predictive onsets and offsets for the circadian rhythms of Act and Tb were examined in both lighting conditions. The reactive Act onset occurred 1.1 h earlier (P < 0.01) in LDSN than in LDSq and had a longer alpha-period (1.7 h; P < 0.05). The reactive Tb onset was 0.7 h earlier (P < 0.01) in LDSN. In LDSN, the predictive Act onset advanced by 0.3 h (P < 0.05), whereas the Tb predictive onset remained the same as in LDSq. The phase angle difference between Act and Tb predictive onsets decreased by 0.9 h (P < 0.05) in LDSN, but the offsets of both measures remained unchanged. In this study, animals exhibited different circadian entrainment characteristics under LDSq and LDSN, suggesting that gradual and abrupt transitions between light and dark may provide different temporal cues.

NASA Discipline Regulatory Physiology↗

Sampling and Control Circuit Board for an Inertial Measurement Unit

A circuit board that serves as a control and sampling interface to an inertial measurement unit ("IMU") is provided. The circuit board is also configured to interface with a local oscillator and an external trigger pulse. The circuit board is further configured to receive the external trigger pulse from an external source that time aligns the local oscillator and initiates sampling of the inertial measurement device for data at precise time intervals based on pulses from the local oscillator. The sampled data may be synchronized by the circuit board with other sensors of a navigation system via the trigger pulse.

Chelmins, David T↗

Thomson Scattering Diagnostic Data Acquisition Systems for Modern Fusion Systems

Uniquely designed complex data acquisition system for Thomson scattering diagnostic was developed. It allows recording short duration (3-5 ns) scattered pulses with 2 GHz sampling rate and 10-bit total resolution in oscilloscope mode. The system consists up to 48 photo detector modules with 0- 200 MHz bandwidth, 1-48 simultaneously sampling ADC modules and synchronization subsystem. The photo detector modules are based on avalanche photodiodes (APD) and ultra-low noise trans-impedance amplifiers. ADC modules include fast analog to digital converters and digital units based on the FPGA (Field- Programmable Gate Array) for data processing and storage. The synchronization subsystem is used to form triggering pulses and to organize the simultaneously mode of ADC modules operation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronized Stress-strain Measurements in Dynamic Loading at High Pressure using D-DIA

A new data collection protocol for forced oscillation experiments using a multianvil high pressure device is reported. We derive the stress of the sample at high pressure and temperature from synchrotron x-ray diffraction that is synchronized with sample strain measurements from x-ray radiographs. This method yields stress directly from the sample rather than a stress proxy. Furthermore, the diffraction pattern yields useful information concerning time evolution of structurally related phenomena. Here we illustrate some of these possibilities with high pressure experimental data.

99 GENERAL AND MISCELLANEOUS↗

Stellar activity in synchronized binaries. I - Dependence on rotation

A large sample of late-type binaries with orbital periods from 1 to 100 days has been examined for relationships between stellar activity and rotation period (assumed - with a few exceptions - to be synchronized with the stellar orbital period). Most of the systems are in the RS Canum Venaticorum class of close binaries; none are contact binaries. The activity diagnostics were observed with the IUE and the Einstein Observatory and range from the mid-chromosphere to the corona. There is a dependence of activity on rotation in the synchronized binaries; surface flux is the preferable measure of activity and is best when steps are taken to remove variations in activity filling factors.

Basri, G.↗

Digital demodulator-correlator

An apparatus for demodulation and correlation of a code modulated 10 MHz signal is presented. The apparatus is comprised of a sample and hold analog-to-digital converter synchronized by a frequency coherent 40 MHz pulse to obtain four evenly spaced samples of each of the signal. Each sample is added or subtracted to or from one of four accumulators to or from the separate sums. The correlation functions are then computed. As a further feature of the invention, multipliers are each multiplied by a squarewave chopper signal having a period that is long relative to the period of the received signal to foreclose contamination of the received signal by leakage from either of the other two terms of the multipliers.

Layland, J. W.↗

Overview and Scientific Agenda of Global Precipitation Mission

This paper addresses the status of the Global Precipitation Mission (GPM) currently planned for launch in the 2007-2008 time frame. The GPM notional design involves a 9-member satellite constellation, one of which wilt be an advanced TRMM-like "core" satellite carrying a dual-frequency Ku-Ka band radar (DFPR) and a TMI-like radiometer. The other eight members of the constellation will be considered daughters of the core satellite, each carrying some type of passive microwave radiometer measuring across the 10.7 - 85 GHz ,frequency range - likely to include a combination of lightweight satellites and co-existing operational/Experimental satellites carrying passive microwave radiometers (i.e., SSM/I and AMSR-E & -F). The constellation is designed to provide no worse than 3-hour sampling at any spot on the globe using sun-synchronous orbit architecture for the daughter satellites, with the core satellite providing relevant measurements on internal cloud-precipitation microphysical processes and the "training-calibrating" information for retrieval algorithms used on daughter satellite measurements. The GPM is organized internationally, currently involving a partnership between NASA in the US, NASDA in Japan, and ESA in Europe (representing the European community nations). The mission is expected to involve additional international participants, sister agencies to the mainstream space agencies, and a diverse collection scientists from academia, government, and the private sector, A critical element in understanding the scientific thinking which has motivated the GPM project is an understanding of what scientific problems TRMM has and has not been able to address and at what scales. The TRMM satellite broke important scientific ground because it carried to space an array of rain-sensitive instruments, two of which were specifically designed for physical precipitation retrieval. These were the 9-channel TRMM Microwave Imager (TMI) and the 13.8 GHz Precipitation Radar (PR). By the same token, because TRMM is a single satellite in a low inclination, low altitude, non-sun-synchronous orbit, it cannot provide global coverage or regular diurnal sampling. These features are essential for many current scientific inquiries involving physical processes of climate and the global water cycle, the modeling of hydrometeorological-biogeochemical cycling, and coupled land-atmosphere/ocean-atmosphere exchanges. Moreover, TRMM has not been able to retrieve explicit properties of the drop size distribution (DSD), a final major barrier to making accurate rain measurements, because the single frequency TRMM radar cannot measure differential reflectivity. which is a minimal requirement for attacking rain retrieval within the framework of extinction cross-section-dependency. GPM is expected to surmount much of the DSD retrieval problem because its core satellite wilt have the capacity to make differential reflectivity measurements with its Ku-Ka band radar (13.6 - 35 GHz) called DFPR - being developed by NASDA/CRL in Japan. This paper will provide an overview of the above issues as well as present a discussion on the expected measurement improvements.

Smith, Eric A.↗

On Shaft Data Acquisition System (OSDAS)

On Shaft Data Acquisition System (OSDAS) is a rugged, compact, multiple-channel data acquisition computer system that is designed to record data from instrumentation while operating under extreme rotational centrifugal or gravitational acceleration forces. This system, which was developed for the Heritage Fuel Air Turbine Test (HFATT) program, addresses the problem of recording multiple channels of high-sample-rate data on most any rotating test article by mounting the entire acquisition computer onboard with the turbine test article. With the limited availability of slip ring wires for power and communication, OSDAS utilizes its own resources to provide independent power and amplification for each instrument. Since OSDAS utilizes standard PC technology as well as shared code interfaces with the next-generation, real-time health monitoring system (SPARTAA Scalable Parallel Architecture for Real Time Analysis and Acquisition), this system could be expanded beyond its current capabilities, such as providing advanced health monitoring capabilities for the test article. High-conductor-count slip rings are expensive to purchase and maintain, yet only provide a limited number of conductors for routing instrumentation off the article and to a stationary data acquisition system. In addition to being limited to a small number of instruments, slip rings are prone to wear quickly, and introduce noise and other undesirable characteristics to the signal data. This led to the development of a system capable of recording high-density instrumentation, at high sample rates, on the test article itself, all while under extreme rotational stress. OSDAS is a fully functional PC-based system with 48 channels of 24-bit, high-sample-rate input channels, phase synchronized, with an onboard storage capacity of over 1/2-terabyte of solid-state storage. This recording system takes a novel approach to the problem of recording multiple channels of instrumentation, integrated with the test article itself, packaged in a compact/rugged form factor, consuming limited power, all while rotating at high turbine speeds.

Pedings, Marc↗

Determination of Pass/Fail Criteria for Promoted Combustion Testing

Promoted ignition testing is used to determine the relative flammability of metal rods in oxygen-enriched atmospheres. In these tests, a promoter is used to ignite each metal rod to start the sample burning. Experiments were performed to better understand the promoted ignition test by obtaining insight into the effect a burning promoter has on the preheating of a test sample. Test samples of several metallic materials were prepared and coupled to fast-responding thermocouples along their length. Various ignition promoters were used to ignite the test samples. The thermocouple measurements and test video was synchronized to determine temperature increase with respect to time and length along each test sample. A recommended length of test sample that must be consumed to be considered a flammable material was determined based on the preheated zone measured from these tests. This length was determined to be 30 mm (1.18 in.). Validation of this length and its rationale are presented.

Sparks, Kyle M.↗

Progress towards materials science above 1000 GPa (10 Mbar) on the NIF laser

Solid state dynamics experiments at extreme pressures, P > 1000 GPa (10 Mbar), and ultrahigh strain rates (1.e6-1.e8 1/s) are being developed for the National Ignition Facility (NIF) laser. These experiments will open up exploration of new regimes of materials science at an order of magnitude higher pressures than have been possible to date. Such extreme, solid state conditions can be accessed with a ramped pressure drive. The experimental, computational, and theoretical techniques are being developed and tested on the Omega laser. Velocity interferometer measurements (VISAR) establish the high pressure conditions generated by the ramped drive. Constitutive models for solid state strength under these conditions are tested by comparing simulations with experiments measuring perturbation growth from the Rayleigh-Taylor instability in solid state samples of vanadium. Radiography techniques using synchronized bursts of x-rays have been developed to diagnose this perturbation growth. Experiments on Omega demonstrating these techniques at peak pressures of {approx}1 Mbar will be discussed. The time resolved observation of foil cracking and void formation show the need for tamped samples and a planar drive.

42 ENGINEERING↗

Automatic frequency control for FM transmitter

An automatic frequency control circuit for an FM television transmitter is described. The frequency of the transmitter is sampled during what is termed the back porch portion of the horizontal synchronizing pulse which occurs during the retrace interval, the frequency sample compared with the frequency of a reference oscillator, and a correction applied to the frequency of the transmitter during this portion of the retrace interval.

Honnell, M. A.↗

Integrating a Microwave Radiometer into Radar Hardware for Simultaneous Data Collection Between the Instruments

The conventional method for integrating a radiometer into radar hardware is to share the RF front end between the instruments, and to have separate IF receivers that take data at separate times. Alternatively, the radar and radiometer could share the antenna through the use of a diplexer, but have completely independent receivers. This novel method shares the radar's RF electronics and digital receiver with the radiometer, while allowing for simultaneous operation of the radar and radiometer. Radars and radiometers, while often having near-identical RF receivers, generally have substantially different IF and baseband receivers. Operation of the two instruments simultaneously is difficult, since airborne radars will pulse at a rate of hundreds of microseconds. Radiometer integration time is typically 10s or 100s of milliseconds. The bandwidth of radar may be 1 to 25 MHz, while a radiometer will have an RF bandwidth of up to a GHz. As such, the conventional method of integrating radar and radiometer hardware is to share the highfrequency RF receiver, but to have separate IF subsystems and digitizers. To avoid corruption of the radiometer data, the radar is turned off during the radiometer dwell time. This method utilizes a modern radar digital receiver to allow simultaneous operation of a radiometer and radar with a shared RF front end and digital receiver. The radiometer signal is coupled out after the first down-conversion stage. From there, the radar transmit frequencies are heavily filtered, and the bands outside the transmit filter are amplified and passed to a detector diode. This diode produces a DC output proportional to the input power. For a conventional radiometer, this level would be digitized. By taking this DC output and mixing it with a system oscillator at 10 MHz, the signal can instead be digitized by a second channel on the radar digital receiver (which typically do not accept DC inputs), and can be down-converted to a DC level again digitally. This unintuitive step allows the digital receiver to sample both the radiometer and radar data at a rapid, synchronized data rate (greater than 1 MHz bandwidth). Once both signals are sampled by the same digital receiver, high-speed quality control can be performed on the radiometer data to allow it to take data simultaneously with the radar. The radiometer data can be blanked during radar transmit, or when the radar return is of a power level high enough to corrupt the radiometer data. Additionally, the receiver protection switches in the RF front end can double as radiometer calibration sources, the short (four-microsecond level) switching periods integrated over many seconds to estimate the radiometer offset. The major benefit of this innovation is that there is minimal impact on the radar performance due to the integration of the radiometer, and the radiometer performance is similarly minimally affected by the radar. As the radar and radiometer are able to operate simultaneously, there is no extended period of integration time loss for the radiometer (maximizing sensitivity), and the radar is able to maintain its full number of pulses (increasing sensitivity and decreasing measurement uncertainty).

McLinden, Matthew↗

Excitation–emission matrices and synchronous fluorescence spectroscopy for the diagnosis of gastrointestinal cancers

We report the development of an improved fluorescence technique for cancer diagnostics in the gastrointestinal tract. We investigate the fluorescence of ex vivo colorectal (cancerous and healthy) tissue samples using excitation–emission matrix (EEM) and synchronous fluorescence spectroscopy (SFS) steady-state approaches. The obtained results are processed for revealing characteristic fluorescence spectral features with a valuable diagnostic meaning. The main tissue fluorophores, contributing to the observed fluorescence, are tyrosine, tryptophan, NADH, FAD, collagen and elastin. Based on the results of the Mann–Whitney test as useful parameters for differentiation of gastrointestinal cancer from normal mucosa, we suggest using excitation wavelengths in the range 300 – 360 nm for fluorescence spectroscopy and wavelengths intervals of 60 nm and 90 nm for SFS. (laser biophotonics)

60 APPLIED LIFE SCIENCES↗

A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double echo symmetry-based REDOR and RESPDOR pulse sequences for proton detected measurements of heteronuclear dipolar coupling constants

1 H{X} symmetry-based rotational echo double resonance pulse sequences (S-REDOR) and symmetry-based rotational echo saturation pulse double resonance (S-RESPDOR) solid-state NMR experiments have found widespread application for 1 H detected measurements of difference NMR spectra, dipolar coupling constants, and internuclear distances under conditions of fast magic angle spinning (MAS). In these experiments the supercycled $\text{R4}^2_1 (\text{SR4}^2_1)$ symmetry-based recoupling pulse sequence is typically applied to the 1 H spins to reintroduce heteronuclear dipolar couplings. However, the timing of $\text{SR4}^2_1$ and other symmetry-based pulse sequences must be precisely synchronized with the rotation of the sample, otherwise, the evolution of 1 H CSA and other interactions will not be properly refocused. For this reason, significant distortions are often observed in experimental dipolar dephasing difference curves obtained with S-REDOR or S-RESPDOR pulse sequences. Here we introduce a family of double echo (DE) S-REDOR/S-RESPDOR pulse sequences that function in an analogous manner to the recently introduced $t_1$-noise eliminated (TONE) family of dipolar heteronuclear multiple quantum coherence (D-HMQC) pulse sequences. Through numerical simulations and experiments the DE S-REDOR/S-RESPDOR sequences are shown to provide dephasing difference curves similar to those obtained with S-REDOR/S-RESPDOR. However, the DE sequences are more robust to the deviations of the MAS frequency from the ideal value that occurs during typical solid-state NMR experiments. In this work, the DE sequences are shown to provide more reliable 1 H detected dipolar dephasing difference curves for nuclei such as 15 N (with isotopic labelling), 183 W and 35 Cl. The double echo sequences are therefore recommended to be used in place of conventional S-REDOR/S-RESPDOR sequences for measurement of weak dipolar coupling constants and long-range distances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computation of absolute hydration and binding free energy with free energy perturbation distributed replica-exchange molecular dynamics.

Distributed Replica (REPDSTR) is a powerful parallelization technique enabling simulations of a group of replicas in a parallel/parallel fashion, where each replica is distributed to different nodes of a large cluster [Theor. Chem. Acc. 2003, 109, 140]. Here, we use the framework provided by REPDSTR to combine a staged free energy perturbation protocol with replica-exchange molecular dynamics (FEP/REMD). The structure of REPDSTR, which allows multiple parallel input/output (I/O), facilitates the treatment of replica-exchange to couple the N window simulations corresponding to different values of the thermodynamic coupling parameters. As a result, each of the N synchronous window simulations benefit from the sampling carried out by the N-1 others. As illustrative examples of the FEP/REMD strategy, calculations of the absolute hydration and binding free energy of small molecules were performed using the biomolecular simulation program CHARMM adapted for the IBM Blue Gene/P platform. The computations show that a FEP/REMD strategy significantly improves the sampling and accelerates the convergence of absolute free energy computations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗