Search NASA⌕ Search

SEARCH · Search NASA

Results for “system noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Operation of the SUPARAMP at 33GHz

A 9mm degenerate parametric amplifier was constructed using a linear, series array of unbiased Josephson junctions as the active, nonlinear element. A balanced diode mixer was used as a synchronous detector, with a single source serving both as the pump and as the mixer local oscillator. A stable, net gain of 15 dB in an instantaneous bandwith (FWHM) of 3.4 GHz was achieved. A system noise temperature of 220 K + or - 5 K (DSB) was measured with a SUPARAMP contribution of only 20 K x or - 10 K. Output saturation was observed and complicates the interpretation of the noise temperature measurements and may render them upper limits. A comparison was made with the results of an earlier 3 cm suparamp. The data is in substantial agreement with theoretical predictions.

Chiao, R. Y.↗

Operation of the SUPARAMP at 33 GHz

A 9-mm degenerate parametric amplifier has been constructed using a linear series array of unbiased Josephson junctions as the active nonlinear element. A balanced diode mixer was used as a synchronous detector, with a single source serving both as the pump and as the mixer local oscillator. A stable net gain of 15 dB in an instantaneous bandwidth (FWHM) of 3.4 GHz has been achieved. A system noise temperature of 220 plus or minus 5 K (DSB) was measured with a SUPARAMP contribution of only 20 plus or minus 10 K. Output saturation has been observed. This complicates the interpretation of noise-temperature measurements and may render them upper limits. Comparison is made with the results of an earlier 3-cm SUPARAMP.

Chiao, R. Y.↗

Adaptive multibeam phased array design for a Spacelab experiment

The parametric tradeoff analyses and design for an Adaptive Multibeam Phased Array (AMPA) for a Spacelab experiment are described. This AMPA Experiment System was designed with particular emphasis to maximize channel capacity and minimize implementation and cost impacts for future austere maritime and aeronautical users, operating with a low gain hemispherical coverage antenna element, low effective radiated power, and low antenna gain-to-system noise temperature ratio.

Noji, T. T.↗

A 230-GHz radiometer system employing a second-harmonic mixer

A radiometer system for use in the 1.3 mm region has been constructed and used for radio astronomical observations. A second-harmonic mixer employing a single Schottky diode downconverts the incident power to an IF frequency of about 1400 MHz. The measured double-sideband system noise temperature is 6000 K (noise figure = 13 dB) and the double-sideband mixer conversion loss is calculated to be 10 dB. The mixer is tunable over a range of at least 15 GHz.

Goldsmith, P. F.↗

Examination of the DSN X-band weather specification

Effects of weather on Deep Space Network system performance at X-band are examined by comparing a record of 64 meter system noise temperatures with weather observations taken at approximately the same times and places.

Source record↗

A tutorial introduction to Very Long Base-line Interferometry (VLBI) using bandwidth synthesis

The basic principles underlying very long baseline interferometry (VLBI) are described by using bandwidth synthesis. The basic signal processing approach is detailed. Summarized results show the tradeoff of measurement accuracy with spanned bandwidth, source strength, antenna size and efficiency, system noise temperature, and data volume. Minimization of required antenna time for a given baseline measurement accuracy is also discussed.

Molinder, J. I.↗

High-power dual-directional coupler

Water-cooled coupler installed in S-band polarization diversity (SPD) cone is used to calibrate receiving-station relay. Coupler operates without arcing at 400 kw and permits accurate calibration of entire system below antenna feed horn. Device has good directivity, contributes less than 0.01 K to system noise temperature, and eliminates saturation of ground station and spacecraft receivers during high-power operation.

Otoshi, T. Y.↗

Heterodyne detection of the 752.033-GHz H2O rotational absorption line

A tunable high resolution two stage heterodyne radiometer was developed for the purpose of investigating the intensity and lineshape of the 752.033 GHz rotational transition of water vapor. Single-sideband system noise temperatures of approximately 45,000 K were obtained using a sensitive GaAs Schottky diode as the first stage mixer. First local oscillator power was supplied by a CO2 laser pumped formic acid laser (761.61 GHz), generating an X-band IF signal with theoretical line center at 9.5744 GHz. Second local oscillator power was provided by means of a 3 GHz waveguide cavity filter with only 9 dB insertion loss. In absorption measurements of the H2O taken from a laboratory simulation of a high altitude rocket plume, the center frequency of the 752 GHz line was determined to within 1 MHz of the reported value. A rotational temperature 75 K, a linewidth 5 MHz and a Doppler shift 3 MHz were measured with the line-of-sight intersecting the simulated-plume axis at a distance downstream of 30 nozzle diameters. These absorption data were obtained against continuum background radiation sources at temperatures of 1175 and 300 K.

Dionne, G. F.↗

The table mountain 8-mm-wavelength interferometer

The system components, performance, and calibration of two element radio interferometer operating at 8.33 mm wavelength are discussed. The interferometer employs a 5.5 m and a 3 m diameter antenna on an east-west baseline of 60 or 120 m, yielding fringe spacings at transit of 28 or 14 in. respectively. The broad intermediate frequency bandpass of 100 to 350 MHz and the system noise temperature of 500 K provide high sensitivity for the measurement of continuum sources. The interferometer has been used for high resolution studies of the planets and the Sun, and it is currently being adapted to study solar flare emissions at high spatial and time resolution.

Janssen, M. A.↗

The Table Mountain 8-mm wavelength interferometer

A two-element radio interferometer operating at 8.33-mm wavelength has been developed at the Jet Propulsion Laboratory's Table Mountain Observatory near Wrightwood, CA. The interferometer employs a 5.5-m and a 3-m diameter antenna on an east-west baseline of 60 or 120 m, yielding fringe spacings at transit of 28 or 14 arcsec, respectively. The broad intermediate-frequency bandpass of 100-350 MHz and the system noise temperature of 500 K provide high sensitivity for the measurement of continuum sources. The interferometer has been used for high-resolution studies of the planets and the sun, and it is currently being adapted to study solar flare emissions at high spatial and time resolution.

Janssen, M. A.↗

Surface resistivity measurements of candidate subreflector surfaces

Subreflectors on DSN antennas have historically been of formed and welded sheet metal construction, which is quite costly. Flame-spray metallized fiberglass-epoxy offers an alternative technique at much lower cost. Results of a study to show that system noise temperature would be increased about 0.3 K at X-band when using the alternate material is presented.

Thom, E. H.↗

The System View

Analysis of spacecraft to ground communications link performance and a description of the Deep Space Network system is provided. Due to the tremendous distances involved in communicating between the spacecraft at the edge of our solar system and Earth, communications link performance is stretched to the limit of theoretical predictions. This is required in order to return the maximum amount of data possible during critical events such as planetary flybys. The link analysis provides a basis for the initial link design before spacecraft launch and performance prediction and monitoring during spacecraft flight. Additionally, it indicates what performance upgrades are required for mission extensions and new missions. Performance is improved through the use of a larger antenna collecting area, greater transmitter power, lower receiving system noise temperature and more sophisticated data coding schemes. The performance of the Deep Space Station configuration which serves as the ground portion of the communications link is assessed.

Noreen, G. K.↗

Low Noise Amplifiers

One of the great technical challenges facing the Deep Space Network is receiving signals from a severely weight limited spacecraft hundreds of thousands to billions of kilometers from Earth. This weight limitation has always imposed strict limitations on the size of the spacecraft antenna and the amount of transmitter power radiated. The communication burden is placed upon the ground systems of the Deep Space Network which must recover an extremely weak signal in the presence of nearly overwhelming amounts of noise. Two key parameters that determine the signal to noise ratio of a received signal using a deep space station are the collecting area and efficiency of the antenna, and the amount of noise which is generated in, as well as allowed to enter in, the antenna-mounted receiver. These parameters are used to describe the relative ability of a deep space station to receive weak signals. As spacecraft to Earth communication distances have increased, the Deep Space Network engages in a relentless effort to increase the figure of merit through larger and more efficient antennas, higher frequencies, and lower system noise temperature.

Petty, S. M.↗

The design and planning of feeder links to broadcasting satellites

Design and planning guidelines being followed to define feeder link parameters for the U.S. ITU Region 2 DBS system are outlined. The carrier/noise (C/N) ratio determines the signal quality acceptable to the consumer and sets the standards which the link must meet. A 10 dB margin is required to meet a 99 percent availability criterion for the times of heaviest rainfall attenuation. The receiver gain is limited by the bandwidth, system noise temperature, and the antenna size. Three mechanisms have been identified for ensuring receiver discrimination between desired and interfering signals. Test points must be selected to examine the effectiveness of the chosen feeder link configuration in maintaining signal reception and channel separation, of the antennas installed, and of the orbital positions of the satellites.

Kiebler, J. W.↗

Ultralow noise performance of an 8.4-GHz maser-feedhorn system

A total system noise temperature of 6.6 K was demonstrated with an 8.4-GHz traveling wave maser and feedhorn operating in a cryogenic environment. Both the maser and feedhorn were inserted in the helium cryostat, with the maser operating in the 1.6-K liquid bath and the feedhorn cooled in the helium gas, with a temperature gradient along the horn ranging from the liquid bath temperature at its lower end to room temperature at its top. The ruby maser exhibited 43 dB of gain with a bandwidth of 76 MHz(-3 dB) centered at 8400 MHz. Discussions of the maser, cooled feedhorn, and cryostat designs are presented along with a discussion of the noise temperature measurements.

Johnson, D. L.↗

Space-qualified submillimeter radiometer

The purpose of this research was to develop a reliable submillimeter wave spectrometer for space-borne high frequency spectral line work. The emphasis was on improving the efficiency of frequency multipliers to limit the system components to rugged, low power consumption solid-state devices. This research has allowed Millitech to develop increased efficiency and performance in Millitech's existing line of submillimeter components and systems. Millitech has fabricated and tested a complete solid-state spectrometer front end for use at 560 GHz (the 1(sub 10) to 1(sub 01) transition of water vapor). The spectrometer was designed with the rigors of flight conditions in mind. The spectrometer uses a phase-locked, solid-state Gunn diode oscillator as the local oscillator, employing a tripler to produce about 3 mW of power at 285 GHz, and a low noise second harmonic waveguide mixer which requires less than 2 mW of LO power. The LO (and the signal) is injected into the mixer by means of a quasioptical diplexer. The measured system noise temperature is 2800 K (DSB) over 400 MHz. The whole spectrometer front end is compact (21 cm by 21 cm by 24 cm), light (7.4 kg), and has a power consumption of less than 8 W. Other topics explored in this work include compact frequency agile phase lock loops, optical filters, and InP Gunn oscillators for low noise applications. As a result of this research, the improvement in the design of multipliers and harmonic mixers will allow their use as the LO power for a variety of satellite-borne receivers operating in the 200 to 600 GHz frequency range.

Huguenin, G. R.↗

The electrical conductivities of candidate beam-waveguide antenna shroud materials

The shroud on the beam-waveguide (BWG) antenna at DSS 13 is made from highly magnetic American Society for Testing and Materials (ASTM) A36 steel. Measurements at 8.42 GHz showed that this material (with paint) has a very poor electrical conductivity that is 600 times worse than aluminum. In cases where the BWG mirrors might be slightly misaligned, unintentional illumination and poor electrical conductivity of the shroud walls can cause system noise temperature to be increased significantly. This potential increase of noise temperature contribution can be reduced through the use of better conductivity materials for the shroud walls. An alternative is to attempt to improve the conductivity of the currently used ASTM A36 steel by means of some type of plating, surface treatment, or high-conductivity paints. This article presents the results of a study made to find improved materials for future shrouds and mirror supports.

Otoshi, T. Y.↗