Search NASA⌕ Search

SEARCH · Search NASA

Results for “system power and thermal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

HELIOCOMM: Wireless Controls State-of-the-Art Report

This report introduces the concept of wireless controls in heliostat-based concentrating solar thermal power (CSP) systems. Specifically, the need for wireless communications to be implemented within the heliostat-based CSP systems is identified versus the existing approaches that follow wireline connections which suffer from high installation, operation, and maintenance cost. Furthermore, this report analyzes the most recent advances in the field of developing wireless controls in heliostat-based CSP systems, which are highlighted to be in their infancy given the primitive wireless networking solutions that they currently utilize and test. The main contribution of this report is the introduction of a novel HELIOCOMM system that supports the wireless controls in heliostat-based CSP systems by exploiting the next generation networking technology of integrated access and backhaul. Furthermore, the proposed HELIOCOMM system performs an artificial intelligent clustering approach of the heliostats and clusterhead selection and develops an entropy-based routing model to enable the heliostats to communicate with the central station by considering their energy availability and network traffic. Also, towards efficiently exploiting the limited resources in the developed wireless communication system, a resource allocation module is introduced that performs the maximization of the energy efficiency of each heliostat by minimizing its corresponding experienced end-to-end latency to communicate with the central station, while performing an intelligent bandwidth splitting in the access and backhaul wireless links. The overall architecture is presented, and its individual building components are discussed in detail.

14 SOLAR ENERGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MODELING AND OPTIMIZATION OF A PCM-BASED OCEAN THERMAL ENERGY HARVESTER FOR POWERING UNMANNED UNDERWATER VEHICLES

As oceans cover over 70% of the planet’s surface, they represent a large reservoir of resources that remained vastly untapped. Uncrewed Underwater Vehicles (UUVs) are becoming key technology for ocean exploration. Ocean thermal gradient is a permanent and reliable energy source that can be used to power UUVs using phase change material (PCM)-based thermal engines. However, the main drawback of this technology is its low conversion efficiency. When using PCM-based thermal engines to power UUVs, there are different energy conversion stages, thermal-hydraulic, hydraulic-kinetic, kinetic-electrical, dependent of a wide variety of parameters. Thus, optimization of the overall energy conversion is still a challenge for powering the increasing energy demanding UUVs for long missions. The goal of this study is to propose a PCM-based ocean thermal energy harvesting system for powering the Solo II float. Using the ocean thermal energy reduces the cost for battery replacement and expands the float’s mission time. For this purpose, we developed a multiphysics model for a system consisting of thermal material, hydraulic, and electrical systems. This system is designed to provide the electrical power needed for the instruments aboard the underwater vehicle. The models of the hydraulic and the electric systems are implemented in MATLAB-Simulink/Simscape environment. The final model developed can provide 13.66 kJ of electrical energy, which is more than 1.5 times the energy requirement per cycle for the SOLO II float.

Ouro-Koura, Habilou↗

Thermal-Mechanical Analysis of an Additive Manufacturing Ceramic Heat Exchanger for High-Temperature Recuperator in a sCO2 Power System

Supercritical CO2 (sCO2) Brayton power cycle can be configured in a closed-loop power system and has a potentially high cycle efficiency. Compactness and high efficiency of a sCO2 power block make the sCO2 Brayton cycle a versatile power cycle in broad applications. While many heat sources are of sufficient intensity to produce high temperature working fluids to achieve high cycle efficiency, the thermal-mechanical stability of traditional materials (e.g., steels and nickel-based superalloys) used in construction of heat exchangers and turbine components limits the operating conditions and thus thermodynamic efficiency of the system. This effort seeks to establish the viability of ceramic heat exchanger technologies for the most extreme operating conditions envisioned for power generation and other high temperature processes. Heat exchangers constructed from ultra-high temperature ceramics, a class of extreme environment materials featuring melting points (Tmp.) above 3000 degrees C, is particularly appealing for sCO2 Brayton cycles given their ultra-low creep rates and very high retained strength at low homologous temperatures (i.e., T < 0.5 Tmp., or at least 1500 degrees C). To translate these materials properties to ultra-high temperature heat exchangers, innovations are required in ceramic manufacturing techniques to realize the complex architectures featured in compact heat exchangers with high power density. With appropriate processing, ZrB2-SiC based compositions can be sintered to near full density and shaped into complex topologies via ceramic additive manufacturing methods. This paper analyzes heat exchanger designs and explores thermal-mechanical implications of the operating environment. Thermal flow, heat transfer, and conjugate mechanical analyses provide insights into benefits and risks associated with the design approach.

additive manufacturing↗

Advanced Power Electronics and Electric Machines [Slides]

The presentation provides an overview of NREL's Advanced Power Electronics and Electric Machines (APEEM) group and its research activities. Power electronics thermal management systems for electric-drive vehicles are described and performance metrics are provided. Additionally, advanced cooling technologies developed at NREL are presented. Finally, an overview is provided for electric machine cooling, integrated drives, and thermomechanical research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Thermal Management Approaches for Integrated Traction Drives in Electric Vehicles

The continuous push to increase power densities of electric vehicle (EV) traction drive systems necessitates combining electric motor and power electronics into one unit. A single, compact traction drive unit with fewer interconnecting components also facilitates fast, automated assembly of electric vehicles, driving production costs down and enabling wider adoption of EVs. There are a number of challenges associated with the integration of power electronics with the electric machine, including thermal management of the combined traction drive system. However, one important benefit of integration from the thermal management system perspective is the potential for using a single fluid loop instead of two separate cooling systems for the electric machine and the power electronics/inverter. This paper reviews several integration approaches and, employing finite element analysis (FEA), compares thermal management solutions for the combined electric machine and power electronics systems. Namely, three different scenarios are modeled: (1) independent component (motor and power electronics) cooling, which is compared to the combined cooling system approach for (2) radially and (3) axially integrated power electronics modules into the motor enclosure. Temperature distributions for selected thermal loads and thermal resistances from the key heat-generating components to the cooling fluid are compared for each scenario.

47 OTHER INSTRUMENTATION↗

Core Design of the Holos-Quad Microreactor

The Holos-Quad micro-reactor concept, developed by HolosGen LLC, is equipped with a 22 MWt (Mega-Watt thermal) core and an integral power conversion system converting the core thermal energy into approximately 10 MWe (Mega-Watt electric). This design can be configured to support a wide range of applications. It is a very innovative high-temperature gas-cooled reactor concept using TRI-structural ISOtropic particle fuel (TRISO) distributed in graphite hexagonal blocks, cooled with helium in a direct Brayton cycle independently executed by four Subcritical Power Modules (SPMs) fitted into a hardened 40-foot container whose dimensions are in compliance with ISO shipping containers requirements. In FY2019 HolosGen LLC was awarded by the Department of Energy Advanced Research Project Agency-Energy (DOE ARPA-E) under the MEITNER funding program. As part of the MEITNER award, the Argonne National Laboratory (ANL) contributed expertise through two specialized teams: The “Design Team” and the “Resource Team”. The Design Team was dedicated to validate feasibility of the Holos-Quad core and to optimize its core design through neutronics analyses. The Resource Team was dedicated to feasibility verification via high-fidelity codes of Holos-Quad thermal-hydraulic, heat transfer, shielding, and structural aspects. This report summarizes the activities conducted by ANL Design Team. A rigorous design approach based on multi-criteria optimization and code-to-code comparison involving stochastic and high-fidelity deterministic solutions was developed and employed at several evolutionary stages of the Holos-Quad design. Several generations of the Holos-Quad core were designed within this project before converging to the current full-scale Gen 2+ design that is detailed in this report. Figure EA-1 illustrates a cross-sectional view of Gen 2+ Holos-Quad core configuration, and Figure EA-2 provides a simplified perspective view of 1-of-4 SPMs. The Holos-Quad uses four thermal-hydraulically independent SPMs locked into stationary positions during power operation, surrounded by BeO reflector and structural component fully comprised within the dimensional constraints represented by traditional ISO containers. One of the benefits of this approach is to enable transportation of each SPM promptly after irradiation in shielded containers. The core is designed to operate for approximately 8 full-power years while the reactivity controls and power conversion system enable load-following operations. The reactivity controls are represented by independent, diversified, and redundant reactivity control systems based on control drums and redundant sets of shutdown rods. The high-fidelity simulation tools were used to assess detailed power and flux distributions of the three-dimensional full-core or quarter-core of the Gen 2+ configuration. Single-physics and multi-physics simulations of the neutronics code PROTEUS and the thermal-hydraulic code System Analysis Module (SAM) were performed to analyze the Holos design configurations with detailed high-fidelity solutions. The design work performed confirmed feasibility of the Holos-Quad concept, provided realistic design description for detailed design of the operational system, and identified several core design improvements to be further considered for future reactor development activities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multistage robust optimization for the day-ahead scheduling of hybrid thermal-hydro-wind-solar systems

The integration of large-scale uncertain and uncontrollable wind and solar power generation has brought new challenges to the operations of modern power systems. In a power system with abundant water resources, hydroelectric generation with high operational flexibility is a powerful tool to promote a higher penetration of wind and solar power generation. In this paper, we study the day-ahead scheduling of a thermal-hydro-wind-solar power system. The uncertainties of renewable energy generation, including uncertain natural water inflow and wind/solar power output, are taken into consideration. We explore how the operational flexibility of hydroelectric generation and the coordination of thermal-hydro power can be utilized to hedge against uncertain wind/solar power under a multistage robust optimization (MRO) framework. To address the computational issue, mixed decision rules are employed to reformulate the original MRO model with a multi-level structure into a bi-level one. Column-and-constraint generation (C &CG) algorithm is extended into the MRO case to solve the bi-level model. The proposed optimization approach is tested in three real-world cases. Furthermore, the computational results demonstrate the capability of hydroelectric generation to promote the accommodation of uncertain wind and solar power.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

OLCF Summit Supercomputer GPU Snapshots During Double-Bit Errors and Normal Operations

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide double-bit errors using system telemetry data and logs collected from the Summit supercomputer, equipped with 27,648 Tesla V100 GPUs with 2nd-generation high-bandwidth memory (HBM2). The dataset relies on Nvidia XID records internally collected by GPU firmware at the time of failure occurrence, on the reboot-time logs of each Summit node, on node-level job scheduler records collected after each job termination, and on a 1Hz data rate from the baseboard management controllers (BMCs) of each Summit compute node using the OpenBMC event subscription protocol. Technical details can be found in the paper Oles et. al “Understanding GPU Memory Corruption at Extreme Scale: The Summit Case Study” ICS’24 (https://doi.org/10.1145/3650200.3656615).

97 MATHEMATICS AND COMPUTING↗

A Rapid Procedure Development Approach for Multi-stage Validation of Novel Nuclear Power Plant Systems

The integration of renewable energy sources into the modern grid introduces variability in generation, challenging nuclear reactors to remain economically viable amid low wholesale electricity prices. To address this, Idaho National Laboratory?s Flexible Plant Operation and Generation program explores alternative revenue streams, including commoditizing excess thermal energy. A Thermal Power Dispatch (TPD) system enables steam extraction from the secondary loop for industrial uses like hydrogen production via high-temperature steam electrolysis.

99 - GENERAL AND MISCELLANEOUS↗

Flexible Natural Gas/Hydrogen Combined Heat and Power System

District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity as well as heating and cooling to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.

CHP, ID/3D↗

Misuse Detection for a Generalized SFR Test Reactor

Sodium-cooled Fast Reactors (SFRs) present unique challenges for international safeguards. SFRs possess neutron physics characteristics that if configured appropriately could produce more fissile material than consumed. An adversary state may choose to build an SFR, justified by a lack of domestic natural uranium and limited access or interest to procuring uranium from international markets. Once constructed, the state may choose to misuse the SFR for the purpose of diverting fissile plutonium from declared operation. This work shows that a demonstration SFR does not need to be configured as a plutonium breeder to create one Significant Quantity (SQ) of plutonium in a short amount of time (e.g., one to few years). However, such an extreme case of misuse would change the core reactivity in such a way as to be easily indicated by deviations of control rod position compared to declared operation. In this work a contrived SFR demonstration reactor was modeled for the purpose of exploring proliferation scenarios and how such misuse could be detected using the SFR's Reactor Data Acquisition System (RDAS). Typically, the International Atomic Energy Agency (IAEA) does not have access to the control rod position, power, thermal, pressure sensing and indicating systems of nuclear power plants. However, this work shows that such data streams can be compared against a parallel detailed simulation model (a Digital Twin) to detect possible misuse.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Thermal Management System for an Electric Machine With Additively Manufactured Hollow Conductors With Integrated Heat Pipes

Here, this paper discusses steps taken to develop a novel thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal finite element analysis is used to determine optimum heat transfer coefficient of the convective boundaries. For some of the convective boundaries, fin-based surface area enhancement is required to reach a target combined overall heat transfer coefficient and surface area performance (UA). This enhancement is worked out using a combination of the Engineering Equation Solver tool and 3D thermal FEA. The thermal management system's UA, and by extension its specific power, sensitivity to coolant temperature is explored. Temperature distribution plots of optimized machine components are also presented and discussed. Lastly, additional heat pipe testing is carried out to study its maximum heat transfer capability's sensitivity to condenser coolant temperature and configuration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synergistic Heat Pumped Thermal Storage and Flexibly Carbon Capture System

As the U.S. grid evolves toward a lower-carbon system, fossil generation assets need to operate in energy markets with high variable renewable energy (VRE) penetration while also decreasing carbon emissions. Current carbon capture and storage (CCS) technologies suffer from high capital cost and an inability to operate flexibly during periods of oscillating demand. The ARPA-E FLECCS Program Phase 1 was created to fund designing and optimizing innovative CCS processes that enable flexibility on a high-VRE grid. To address this need, the Colorado State University (CSU) Team won funding to design a synergized system of thermal energy storage, power generation, and flexible carbon capture to enable breakthrough system performance that achieves an LCOE <$75/MWh with >99% capture rate. This approach will target new or existing natural gas combined cycle power plants. The proposed design utilizes novel hot and cold thermal energy storage (TES) technologies that store low-cost, off-peak electricity as thermal energy to power CCS solvent regeneration and boost plant output during periods of peak demand. The design provides an overall optimized net present value (NPV) by maximizing low carbon power to grid while prices are highest using Storworks Power’s concrete TES technology. The team also capitalizes on decades of ION Clean Energy’s (ION) development in low cost and flexible pioneering solvent technology, which has proven reductions in energy consumption and overall cost of 28% and 38%, respectively, compared with state-of-the-art CCS.

20 FOSSIL-FUELED POWER PLANTS↗