Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature control unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

COVID 19 vaccine distribution solution to the last mile challenge: Experimental and simulation studies of ultra-low temperature refrigeration system

Most COVID-19 vaccines require ambient temperature control for transportation and storage. Both Pfizer and Moderna vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (between -80 °C and -60 °C), while the Moderna vaccine requires -30 °C storage. Pfizer has designed a reusable package for transportation and storage that can keep the vaccine at the target temperature for 10 days. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine. Also, the need for a large amount of ultra-low temperature refrigeration equipment in a short time period creates tremendous pressure on the equipment suppliers. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages. As such, there is a need for a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics. The study proposes an effective, secure, and safe ultra-low temperature refrigeration solution to resolve the vaccine distribution last mile challenge. Furthermore, the approach is to utilize commercially available products, such as refrigeration container units, and retrofit them to meet the vaccine storage temperature requirement. Both experimental and simulation studies are conducted to evaluate the technical merits of this solution with the ability to control temperature at -30 °C or -70 °C as part of the last mile supply chain for vaccine candidates.

60 APPLIED LIFE SCIENCES↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

HYBRID Modeling of DETAIL Experimental Facility

Idaho National Laboratory continues to be at the forefront of advanced reactor systems and integrated energy systems research. Through the Thermal Energy Distribution System (TEDS) and Microreactor Agile Non-nuclear Test Bed (MAGNET) experiments in the Dynamic Energy Transport and Innovation Laboratory (DETAIL) within the Engineering Systems Laboratory, a mix of digital and physical testing systems can explore the operation of thermally and electrically integrated systems. Modeling of these systems has been done using the HYBRID modeling repository of the Integrated Energy Systems program. DETAIL also contains high temperature steam electrolysis (HTSE) units to produce hydrogen and generate the load imposed on MAGNET and TEDS. The dynamic modeling capabilities within the IES program describe the DETAIL components as-built and can be used to evaluate controls, process flows, and overall system conditions.

08 HYDROGEN↗

High-Temperature Wireless Sensor Platform Powered by Energy Scavenging

This paper reports on the development of key components required for a self-powered oscillator unit designed to wirelessly transmit its signal under full insertion in high-temperature (HT) harsh-environments (HE), such as those present in power plants and industrial settings (metallurgic, oil extraction, molding, and aerospace). The oscillator employed a silicon carbide (SiC) power transistor and HT passive components on a screen-printed alumina circuit board capable of operation beyond 300 °C. The HT oscillator circuit was powered solely by in-situ energy scavenging thermoelectric generator (TEG) modules using passive cooling, eliminating the need for an external power supply or active cooling. In addition, a silicon-based external booster circuit was used to achieve the required TEG voltage regulation to test the TEG-powered HT oscillator circuit. The TEG-powered oscillator circuit was tested inside a non-metallic furnace from room temperature to over 300 °C for transmission of a wireless signal, which was detected outside the furnace at 11 ft (3.4 m). Such a wireless transmitting system powered only by in-situ TEGs, with no requirement for external power or active cooling, is very attractive for flexible, mobile stand-alone control and sensor units targeted for operation in HT HE conditions found in power plants and industrial settings.

20 FOSSIL-FUELED POWER PLANTS↗

Self-consistent equilibrium and transport simulations for NSTX-U plasmas enhanced via machine learning surrogate models

The Control-Oriented Transport SIMulator (COTSIM) is an advanced equilibrium and transport code designed for simulating tokamak discharges at computational speeds suitable for control applications. COTSIM’s modular framework enables users to select models that balance accuracy with speed according to specific needs, allowing the code to operate from fast to faster-than-real-time performance levels. This work presents recent enhancements to COTSIM’s predictive accuracy for NSTX-U scenarios, achieved by integrating neural-network-based surrogate models and self-consistent equilibrium calculations. To improve source deposition predictions, a surrogate model for NUBEAM has been incorporated. Additionally, a surrogate model for the Multi-Mode Module (MMM) now supports predictions of anomalous thermal, momentum, and particle diffusivities—key factors for modeling the evolution of temperature and rotation. Each surrogate model was specifically trained for the NSTX-U operational regime to enhance COTSIM’s accuracy while maintaining computational efficiency. Moreover, COTSIM now couples fixed-boundary equilibrium solvers with its transport solvers, enabling self-consistent predictions of plasma profiles and equilibrium evolution over the discharge. Simulation results demonstrate strong agreement between COTSIM and TRANSP predictions for NSTX-U discharges. These substantial advancements expand COTSIM’s utility in model-based control applications for NSTX-U. Potential applications include simultaneous optimization of equilibrium and transport scenarios, integration into digital twins, real-time profile estimation (e.g., temperature and rotation) from limited or noisy measurements, and advanced feedback-based scenario control.

Equilibrium and transport modeling↗

Regional surrogates for predictive control of digital twins

Digital twins of complex systems must involve a model that is fast, generalizable, and usable for real-time control. For example, high-fidelity nonlinear multiphysics simulations can capture laser-material interactions, but are too slow for optimization or model predictive control (MPC). Reduced-order models, used to accelerate such computation, frequently fail to generalize to unseen inputs or control states. We show theoretically that this failure is intrinsic, i.e., that a learned model is non-unique outside the sampled subspace when its low-rank structure arises from limited excitation and clustered eigenvalues, rather than from a user-imposed truncation alone. Motivated by this result, we propose a control-ready regional surrogate-construction framework for both autonomous and nonautonomous dynamics; it employs Koopman lifting to represent nonlinearities, while preserving spatial locality. We illustrate our approach by constructing a control-ready surrogate for the digital twin of a thermal component of additive-manufacturing process. Our surrogate, localized in space through a von Neumann stencil, is learned from noisy high-fidelity simulations that emulate thermal-camera images collected during the manufacturing. It is linear in thermo-physically augmented states so that MPC reduces to a convex quadratic program. The surrogate requires no online correction, generalizes to unseen scan paths and power profiles of the laser, and is more than three orders of magnitude faster than a finite-difference solver. Furthermore, when the MPC sequence computed on the digital twin is applied to this solver, closed-loop temperature regulation is recovered, showing that the surrogate preserves control-relevant input-output behavior.

Data-driven model↗

Coordinated Thermal Safety Attack and Defense on EV Battery Management Systems

Battery temperature sensor and battery current sensor data which are key sensing inputs to the Battery Management Controllers in electric vehicles, are vulnerable to possible cyber/ physical manipulation due to known vulnerabilities inherited from CAN bus technology that is used for in-vehicle communications between electronic control units that transfer sensing and control data. In this paper, we first create a simulation that enables us to evaluate impact of cyber physical attacks on electric vehicle battery management system in a controlled environment that violates thermal safety. Specifically, we emulate a Level 3 - DC fast charging system with SAE J1772/CCS, integrated with standard charging controls and thermal safety controls on EVs, and various sensing data flows. Second, we propose a coordinated current and battery temperature attack that has crippling economic, and safety impacts. Third, we quantify the usability, economic and safety impacts of such attacks as a function of the extent of data manipulation. Finally, we propose a physics model driven detection technique to detect presence of such attacks.

25 ENERGY STORAGE↗

Spatially resolved phase transformation mapping in 410 stainless steel during additive manufacturing visualized via real-time infrared data

Here, in this study, we demonstrate that spatially resolved cooling curves derived from real-time infrared (IR) thermography during additive manufacturing (AM) can capture spatial variations in phase transformation temperatures through cooling curve analysis (CCA). Using this approach, we show that during laser hot-wire deposition of 410 stainless steel (410SS), the martensite start temperature (M s ) evolves dynamically throughout the build. The M s temperature is spatially nonuniform, ranging from 185 °C to 348 °C, with the lowest values toward the build center and higher values toward the upper region of the deposit. In the lower portion of the build, no M s inflection is detected via CCA, consistent with transformation occurring earlier during thermal cycling followed by tempering during subsequent thermal cycles. These trends in M s are corroborated by characterizing the microstructure by electron backscatter diffraction (EBSD). Traditionally, M s is assumed to be constant, and a single interpass temperature is applied during both deposition and residual stress modeling. Our results demonstrate that IR-derived cooling curves provide a route to spatially and temporally resolved transformation temperature tracking for dynamic interpass control and improved residual-stress modeling.

Additive manufacturing↗

Deciphering supramolecular and polymer-like behavior in metallogels: real-time insights into temperature-modulated gelation and rapid self-assembly dynamics

Bis(pyridyl) urea-based gelators, namely L2 and its isomeric mixture ( L1 + L2 ), are known to self-assemble into 1D architectures capable of inducing supramolecular gelation. Coordination with metal ions such as Ag( I ), Cu( II ), and Fe( III ) introduces structural reinforcement, enabling the formation of distinct 3D networks governed by metal-specific coordination geometries. Here, we present a comprehensive investigation into the temperature-responsive behavior (20–60 °C) of L2 and L1 + L2 , both in the absence and presence of Ag( I ), Dy( III ), Fe( III ), Cu( II ), and Ho( III ), using real-time small-angle neutron scattering (SANS). To probe long-term structural evolution/kinetics of self-assembly, real-time small-angle X-ray scattering (SAXS) was employed on L2 + Ag gels, complemented by differential scanning calorimetry (DSC) to evaluate thermal transitions. Our results reveal strikingly divergent gelation behaviors: L2 forms a highly rigid, covalent polymer-like network, while L1 + L2 exhibits remarkable thermal adaptability. Upon metal coordination, the assemblies exhibit pronounced crystallinity and exceptional thermal stability, as evidenced by persistent Bragg reflections and invariant d-spacings. Intriguingly, L2 : Fe (2 : 1) and L1 : L2 : Fe (0.5 : 0.5 : 1) in acetonitrile-d 3 (ACN-d 3 ) deviate from this trend, forming thermally labile amorphous gels. These systems show a complete loss of crystalline order, reduced Porod exponents—indicative of collapsed or branched fiber morphologies—and prominent melting and glass transition events in DSC. Fitting SANS and SAXS data to the correlation length model unveiled insightful nanostructural features. While most systems displayed minimal temperature-induced variation in mesh size or surface morphology, L2 : Ag in dimethyl sulfoxide-d 6 (DMSO-d 6 )/D 2 O and L2 : Fe (1 : 1) in ACN-d 3 exhibited a rare combination of thermally stable correlation lengths and increasing high- q exponents—strongly suggesting progressive fiber densification or surface smoothing within a robust gel framework. These findings highlight the tunability and structural resilience of supramolecular gels through precise control of ligand architecture, metal coordination, and temperature, offering valuable design principles for functional soft materials.

Pajoubpong, Jinnipha [Univ. of Cincinnati, OH (Uni↗

Wavelength-tunable infrared chiral metasurfaces with phase-change materials

Optical phase-change materials exhibit tunable permittivity and switching properties during phase transition, which offers the possibility of dynamic control of optical devices. Here, a wavelength-tunable infrared chiral metasurface integrated with phase-change material GST-225 is demonstrated with the designed unit cell of parallelogram-shaped resonator. By varying the baking time at a temperature above the phase transition temperature of GST-225, the resonance wavelength of the chiral metasurface is tuned in the wavelength range of 2.33 µm to 2.58 µm, while the circular dichroism in absorption is maintained around 0.44. The chiroptical response of the designed metasurface is revealed by analyzing the electromagnetic field and displacement current distributions under left- and right-handed circularly polarized (LCP and RCP) light illumination. Moreover, the photothermal effect is simulated to investigate the large temperature difference in the chiral metasurface under LCP and RCP illumination, which allows for the possibility of circular polarization-controlled phase transition. The presented chiral metasurfaces with phase-change materials offer the potential to facilitate promising applications in the infrared regime, such as chiral thermal switching, infrared imaging, and tunable chiral photonics.

36 MATERIALS SCIENCE↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Transition Metal Dichalcogenide MoS 2 : Oxygen and Fluorine Functionalization for Selective Plasma Processing

Low-temperature plasma processing is a promising technique for tailoring transition metal dichalcogenides (TMDs). For chalcogen substitution processing, a key challenge is to identify the ion energy window that enables selective chalcogen removal while preserving the metal lattice. Using ab initio molecular dynamics (AIMD), we demonstrate that oxygen and fluorine functionalization widen the processing window by significantly lowering the sulfur sputtering energy threshold (E sputt,S ) of MoS 2 from ∼30 to ∼10 eV via formation of sputtering products such as SO 2 and SF n . Additionally, we show that experimentally relevant cryogenic temperatures strongly affect E sputt,S (T). The dependence is confirmed via AIMD and also predicted by a mechanistic parameter-free theory, suggesting that E sputt (T) generalizes to other TMDs, functionalizations, and surface impact conditions. Our results highlight oxygen/fluorine functionalization, ionic impact angle, and material temperature to be key control parameters for selective, damage-controlled chalcogen removal in TMD processing.

Polyachenko, Yury [Princeton Plasma Physics Labora↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

In situ high-temperature Raman spectroscopy for online EAF slag analysis

Real-time monitoring of slag chemistry is critical for optimizing Electric Arc Furnace (EAF) steelmaking operations, where dynamic variations in slag composition directly influence slag foaming, refractory degradation, and thermal efficiency. Conventional techniques such as X-ray fluorescence (XRF), Fourier-transform infrared (FTIR), and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDS) are commonly used to analyze slag composition, but their offline nature and equipment constraints limit their applicability for online monitoring in harsh industrial environments. To address this challenge, we present an in situ, high-temperature analytical approach that integrates Raman spectroscopy with a custom designed fiber-optic probe for real-time slag characterization at 1550 °C. The system enables non destructive spectral acquisition from molten slags, providing molecular-level insights into silicate polymerization and iron oxidation states. Eight synthetic slag samples were evaluated, and key Raman features—such as Q n silicate units and FeO₄/FeO₆ coordination environments—were identified and quantitatively correlated with slag basicity and Fe₂O₃ content. The results demonstrate agreement between Raman spectral ratios and bulk slag chemistry, validating the method’s capability to track compositional and structural changes under molten temperature. This work establishes the feasibility of deploying fiber-optic Raman probe for online EAF slag monitoring and highlights their potential to support closed-loop control strategies, thereby enhancing process stability, refractory protection, and steel quality in industrial steelmaking applications.

47 OTHER INSTRUMENTATION↗

In-situ neutron radiography of pore-water movement in portland cement mortar under subzero temperature exposure: Insights from D 2 O-H 2 O systems

Neutron radiography was employed in this study to monitor real-time pore water movement in portland cement mortar exposed to subzero temperatures, providing novel insights into freeze-thaw (F-T) damage mechanisms. Deuterated water (D 2 O) was used to hydrate the cement in the mortar specimens, and the pore structure was saturated with water (H 2 O), allowing for a contrast that enabled detailed tracking of water movement predominantly in the pore structure. Furthermore, the mortar sample was placed on a chiller plate set to subzero temperatures, thereby providing a one-dimensional temperature gradient vertically in the sample. Neutron radiography revealed that unfrozen water migrated upward as the freezing front advanced, which can create hydraulic pressure within the mortar microstructure and may contribute to the initiation and propagation of microcracks during F-T cycles. Additional characterization of the concrete made with D 2 O showed a marked contrast to the samples made with H 2 O, including delayed hydration, diminished compressive strength, and greater porosity. Therefore, while mortar made with D 2 O allowed for greater neutron contrast to the pores filled with H 2 O, further study is required to produce mortars with similar properties to those made with H 2 O. In addition, further refinement is needed to the radiography experiment to allow for greater control of temperatures and potential quantification of the water concentration.

Air-void system↗

Molecular H 2 as the Reducing Agent in Low-Temperature Oxide Reduction Using Calcium Hydride

Low-temperature synthesis is crucial for advancing sustainable manufacturing and accessing novel metastable phases. Metal hydrides have shown great potential in facilitating the reduction of oxides at low temperatures, yet the underlying mechanism—whether driven by H - , H 2 , or atomic H—remains unclear. Here, in this study, we employ in situ electrical transport measurements and first- principles calculations to investigate the CaH 2 -driven reduction kinetics in epitaxial α-Fe 2 O 3 thin films. Intriguingly, samples in direct contact with or separated from CaH 2 powders exhibit similar apparent activation energies for H 2 reduction, although direct contact significantly increases the reduction rate. These findings indicate that molecular H 2 is the dominant reducing species in the low-temperature reduction of oxides using CaH 2 , with a key aspect of the hydrides' superior reducing power attributed to their ability to eliminate residual moisture. This work underscores the critical role of moisture control in enabling effective low-temperature oxide reduction for advanced material synthesis.

Wang, Jiayue [SLAC National Accelerator Laboratory↗

The Reservoir Temperature Estimator (RTEst): A multicomponent geothermometry tool

The Reservoir Temperature Estimator (RTEst) is a multicomponent geothermometry tool for estimating reservoir geochemical parameters including reservoir temperature, CO 2 fugacity, mass of water lost or gained, and a reaction factor. It estimates these parameters and their associated uncertainties by minimizing an objective function that is the weighted sum of squares of the saturation indices of a user-selected set of minerals believed to be equilibrated with the reservoir fluid. RTEst accomplishes these estimates by combining the geochemical modeling capabilities of The Geochemist’s Workbench® with the optimization/parameter estimation resources of PEST®. An included interface aids the user in selecting plausible mineral phases to comprise the objective function and calculates their weighting factors. The working principles of RTEst are described and its efficacy is illustrated by presenting results of its application to various geothermal fields with known conditions. These examples show RTEst can account for the alteration of ascending reservoir fluid by mineral (calcite) re-equilibration with changes in temperature, reconstruct waters with CO 2 loss, correct for the deficit of water and other volatiles (CO 2,gas , H 2 S gas ) from boiling, and determine the amount of mixing of thermal and non-thermal waters. RTEst can use data with basis species below detection limit, missing, or unreliable either by assuming equilibrium with a controlling mineral (fixed-analyte method) or by treating the analyte concentration as an optimization parameter. The inverse of variance weighting method included in RTEst provides more representative results than either the normalization or unit weighting methods. Finally, the ability of RTEst to calculate reservoir temperatures, gas fugacity, and mixing fractions demonstrates its usefulness as a tool for evaluating geothermal systems.

15 GEOTHERMAL ENERGY↗

Bench-Scale Apparatus for Rapid, Simultaneous, Comprehensive Vapor–Liquid Equilibrium and Kinetic Property Measurements to Advance CO 2 Capture Solvent Technology

We present here, the design, fabrication, and testing of a new "pressure, volume, temperature (PVT)" apparatus that enables rapid standardized testing for viscosity, vapor–liquid equilibria, and kinetics for water-lean carbon capture solvents. This unit is the first of its kind where equilibrium data are collected during operation as a PTx (pressure–temperature–composition) cell while kinetic data are collected simultaneously with an internal mini wetted-wall contactor (WWC) using controlled adjustments of CO 2 injections to allow for measurements of gas flux (in and out of the liquid). Additionally, in situ measurements of viscosity data are also continuously collected while a solvent is in circulation during gas absorption. This cell empowers comprehensive testing of critical CO 2 capture solvent properties in a single measurement, ensuring all data are collected at the same temperature, pressure, and CO 2 loading. This apparatus also expedites screening of materials since less than 50 mL of sample is needed as compared to 2–3 L needed to get similar data from a conventional WWC. In conclusion, we describe here the methodology of data collected on this new PVT cell, nicknamed “Gary” in honor of Professor Gary Rochelle, for multiple water-lean amine solvents, which we compare to data collected from conventional instrumentation for amine testing.

Zheng, Richard [STARS Technology Corporation, Rich↗