Search NASA⌕ Search

SEARCH · Search NASA

Results for “temporal measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Measurement of Spatial and Temporal Changes in Vegetation from Color-IR Film

The use of color infrared film to measure spatial and temporal changes in vegetation is discussed. The subjects presented are: (1) selection of the sensor, (2) collection of the data, and (3) analysis of the data. The effects of climatology and meteorological parameters on interpretation of the data are analyzed. It is concluded that the color infrared film will enhance the imagery of green plants and will accentuate differences between plants.

Turner, R. M.↗

Spectral and Temporal Laser Fluorescence Analysis Such as for Natural Aquatic Environments

An Advanced Laser Fluorometer (ALF) can combine spectrally and temporally resolved measurements of laser-stimulated emission (LSE) for characterization of dissolved and particulate matter, including fluorescence constituents, in liquids. Spectral deconvolution (SDC) analysis of LSE spectral measurements can accurately retrieve information about individual fluorescent bands, such as can be attributed to chlorophyll-a (Chl-a), phycobiliprotein (PBP) pigments, or chromophoric dissolved organic matter (CDOM), among others. Improved physiological assessments of photosynthesizing organisms can use SDC analysis and temporal LSE measurements to assess variable fluorescence corrected for SDC-retrieved background fluorescence. Fluorescence assessments of Chl-a concentration based on LSE spectral measurements can be improved using photo-physiological information from temporal measurements. Quantitative assessments of PBP pigments, CDOM, and other fluorescent constituents, as well as basic structural characterizations of photosynthesizing populations, can be performed using SDC analysis of LSE spectral measurements.

Chekalyuk, Alexander↗

Dimensional stability of Superinvar

Attention is called to new thermal expansion measurements on temporally stable Superinvar. The measurements indicate that its thermal expansivity vs temperature is more desirable than has been suggested by earlier measurements (Berthold et al., 1976). It is pointed out that at approximately 47 C, the thermal expansion coefficient is zero; however, the coefficient increases rapidly as the temperature departs from 47 C. A second zero-crossing of the expansivity is found at -21 C. The magnitude of negative expansivity between -21 C and 45 C remains bounded and small. No disruptive and reversible phase transition is found at temperatures down to -26 C.

Connors, C.↗

Thematic Mapper geometric correction performance evaluation

The present paper provides a performance evaluation of geometric correction in the Thematic Mapper Image Processing System (TIPS). TIPS forms a part of NASA's Thematic Mapper (TM) data processing facility. During a TM Research and Development period which continues through 1984, the geometric accuracy of TIPS is currently being evaluated. A description is given of TIPS geometric correction system, taking into account a TIPS overview and the Thematic Mapper Control Point Library Build (TCL). TCL generates control point chips which are stored in a library for subsequent use in the Thematic Mapper Archive Generation (TAG). Methods for measuring accuracy are discussed, giving attention to error estimation and direct measurement. A temporal registration evaluation from error estimation is considered along with a temporal evaluation from direct measurement, and a geodetic correction evaluation.

Brooks, J.↗

Temporal averaging of phase measurements in the presence of spurious phase drift - Application to phase-stepped real-time holographic interferometry

A technique that compensates for low spatial frequency spurious phase changes during an interference experiment is developed; it permits temporal averaging of multiple-phase measurements, made before and after object displacement. The method is tested with phase-stepped real-time holographic interferometry applied to cantilever bending of a piezoelectric bimorph ceramic. Results indicate that temporal averaging of the corrected data significantly reduces the white noise in a phase measurement without incurring systematic errors or sacrificing spatial resolution. White noise is reduced from 3 deg to less than 1 deg using these methods.

Ovryn, B.↗

Precipitation of radiation belt electrons by man-made waves A comparison between theory and measurement

The temporal and spectral shape and the absolute flux level of particle pulses precipitated by a VLF transmitter are examined from a theoretical point of view. A test-particle model of the gyroresonant wave-particle interaction is applied to the parameters of the observed cases for calculating the precipitation characteristics. The temporal shapes of the precipitation pulses are found to be controlled (1) by the pitch angle dependence of the particle distribution near the edge of the loss cone and (2) by the multiple interaction of the particles with the waves due to significant atmospheric backscatter.

Inan, U. S.↗

Spatial and temporal variations of the ion velocity measured in the Venus ionosphere

Temporal and spatial deviations of ion velocity from the dominant flow of the Venusian ionosphere were detected in data collected from a retarding potential analyzer (RPA) aboard the Pioneer-Venus orbiter spectrometer. The ion velocity measurements were analyzed for the first 3.5 Venus years of the Pioneer-Venus mission, approximately through orbit 780. The deviations of ion velocity from the dominant velocity of the Venusian ionosphere, which generally flows nightward and is almost symmetric about the sun-Venus axis, affect both the ionospheric structure and dynamics. Two examples of departure from steady symmetric flow that were measured by the RPA are discussed.

Miller, K. L.↗

High-resolution lidar system for measuring the spatial and temporal structure of the mesospheric sodium layer

The design of a high-resolution tunable-dye laser-based lidar system for the study of the mesospheric sodium layer is presented and results of sodium measurements are indicated. The lidar system comprises a tunable flashlamp-pumped dye laser operating at the sodium D2 resonance line at 589.0 nm with a pulse width of 2 microsec FWHM and pulse frequency of 10 Hz and a telescope with a 1.22=m diameter Fresnel lens. Sodium profiles are obtained from the integration of 100 to 250 laser shots, with spatial and temporal resolution enhanced by two-dimensional filtering techniques. Measurements obtained over a 9-hour nighttime period illustrate the highly dynamic nature of the sodium layer, which was observed with a spatial resolution of 2 km and temporal resolution of 30 min. Observations made with a steerable apparatus have confirmed a presunrise enhancement of over 100 percent in sodium column abundance.

Gardner, C. S.↗

Brightness fluctuations in the K-line wings.

A power-spectrum and cross-spectrum analysis has been made of measurements of temporal fluctuations of intensity observed in the K-line wing (2.07 A from line center) and of simultaneous measurements of temporal fluctuations of Doppler displacement of the cores of 3931.122 Fe I and 3933 Ca II (K3). The measurements were made in a quiet region near the center of the sun's disk. We find that the average power spectra of the intensity fluctuations have two significant peaks of about equal strength: one at 0.0033 Hz (300-sec period); and one at about 0.001 Hz (1000-sec period). The average rms value of these intensity fluctuations is 0.0435 plus or minus 0.0082. Maximum brightness comes before maximum violet displacement of the Fe I line.

Cha, M. Y.↗

Techniques for studying gravity waves and turbulence: Horizontal, vertical and temporal resolution needed

One of the most important atmospheric measurements that is needed is a measure of the gravity-wave spectrum. The MST radar has been investigated as means to measure the temporal resolution required to determine gravity-wave oscillations. The required vertical and horizontal resolution is dependent on the particular part of the gravity wave spectrum that is analyzed. Horizontal spacing is also discussed.

Avery, S. K.↗

Measurement and Interpretation of Temporal Variations of the Earths Gravity Field Using GPS and SLR Data

This investigation has had four main thrusts: 1) The analysis of seasonal variations of the Earth's gravitational field using Lageos 1 and 2 SLR data and comparisons to geophysical models. We have estimated the annual variation of the gravity field via a spherical harmonic expansion complete to degree and order 4. We have also constructed a similar model using models of the annual variation in the gravity field due to atmospheric, hydrologic, and ocean mass redistribution. These three models, when combined together, are in excellent agreement with the variations observed by satellite laser ranging. An article on these results was published in the journal Geophysical Research Letters. 2) The second thrust of our investigation has been to analyze the output of a Global Climate Model (GCM) to determine if the GRACE gravity mission can be expected to detect climate change signals. Working with Gary Russell at the Goddard Institute for Space Studies (GISS), we have determined that there are several large secular signals that GRACE might be able to detect, including secular changes in snow cover, sea ice, polar ice, ocean mass, and other variables. It is possible that some of these signals could be detected with 5 years of GRACE measurements - its hard to judge this because the interannual variability in the GCM, which could mask the climate signals, is unreliable. Certainly a follow-on GRACE mission could detect these signals when compared to the data from the initial GRACE mission.). An article on these results will be published in the journal Journal of Geophysical Research. 3) In the last year of the investigation, we developed a new technique for analyzing temporal gravity variations using "geophysical fingerprints", which was successfully demonstrated on 20 years of satellite laser ranging data [Nerem et al., 20031. 4]. We also participated in a workshop on future satellite gravity measurements, which resulted in paper on measuring ocean mass variations using GRACE [Nerem et al., 20031 and on using laser interferometry for future gravity missions [Bender et al., 20031].

Nerem, R. Steven↗

Quantitative measurement of density and velocity in compressible flows using laser-induced iodine fluorescence

A nonintrusive optical technique for the quantitative measurement of molecular density and velocity at a point or in an entire cross-sectional plane of a compressible flowfield is reported. Iodine molecules, seeded into the flowfield reservoir, are excited by a tunable narrow-bandwidth laser and the resulting spatially-resolved fluorescence is collected by a single- or multiple-element detector. A theoretical model for the iodine laser-induced fluorescence process is essential for quantitative measurements and is developed using a rate-equation approach. Density measurements using laser-induced fluorescence are normally complicated by collisional quenching; however, the theory predicts that the off-resonant fluorescent signal is directly proportional to density. Velocity is directly related to the Doppler shift of the iodine absorption line, determined by monitoring the broadband fluorescent signal as the laser is tuned in frequency. Experiments in a steady supersonic flowfield are compared with numerical calculations to demonstrate the accuracy of the approach for density and velocity measurement and the lack of perturbation to the flowfield by the iodine seeding. Extensions of the current approach to density and velocity measurement in lower Mach number flows, to the measurement of pressure and temperature, and to temporally-resolved measurements are discussed.

Mcdaniel, J. C.↗

Evaluation of the TOPEX/Poseidon Altimeter System Over the Great Lakes

The TOPEX/POSEIDON altimeter measurement system is evaluated over the Great Lakes. Using in situ lake level measurements, the temporal variations in lake level are removed from the altimeter measurements, thus permitting the performance of the altimeter system to be assessed.

TOPEX/POSEIDON↗

Long-Term Time Series of Remote Sensing Observations for Development of Regulatory Water Quality Standards

Water quality standards in the U.S. consist of: designated uses (the services that a water body provides; e.g., drinking water, aquatic life, harvestable species, recreation) . criteria that define the environmental conditions that must be maintained to support the uses For estuaries and coastal waters in the Gulf of Mexico, there are no numeric (quantitative) criteria to protect designated uses from effects of nutrients. This is largely due to the absence of adequate data that would quantitatively link biological conditions to nutrient concentrations. The Gulf of Mexico Alliance, an organization fostering collaboration between the Gulf States and U.S. Federal agencies, has identified the development of the numeric nutrient criteria as a major step leading to reduction in MODIS Products Figure 6. Map of the Mobile Bay with a yellow patch indicating the Bon Secour Bay area selected in this study for averaging water clarity parameters retrieved from MODIS datasets. nutrient inputs to coastal ecosystems. Nutrient enrichment in estuaries and coastal waters can be quantified based on response variables that measure phytoplankton biomass and water clarity. Long-term, spatially and temporally resolved measurements of chlorophyll a concentration, total concentration of suspended solids, and water clarity are needed to establish reference conditions and to quantify stressor-response relationships.

Blonski, Slawomir↗

High Precision, Absolute Total Column Ozone Measurements from the Pandora Spectrometer System: Comparisons with Data from a Brewer Double Monochromator and Aura OMI

We present new, high precision, high temporal resolution measurements of total column ozone (TCO) amounts derived from ground-based direct-sun irradiance measurements using our recently deployed Pandora single-grating spectrometers. Pandora's small size and portability allow deployment at multiple sites within an urban air-shed and development of a ground-based monitoring network for studying small-scale atmospheric dynamics, spatial heterogeneities in trace gas distribution, local pollution conditions, photochemical processes and interdependencies of ozone and its major precursors. Results are shown for four mid- to high-latitude sites where different Pandora instruments were used. Comparisons with a well calibrated double-grating Brewer spectrometer over a period of more than a year in Greenbelt MD showed excellent agreement and a small bias of approximately 2 DU (or, 0.6%). This was constant with slant column ozone amount over the full range of observed solar zenith angles (15-80), indicating adequate Pandora stray light correction. A small (1-2%) seasonal difference was found, consistent with sensitivity studies showing that the Pandora spectral fitting TCO retrieval has a temperature dependence of 1% per 3K, with an underestimation in temperature (e.g., during summer) resulting in an underestimation of TCO. Pandora agreed well with Aura-OMI (Ozone Measuring Instrument) satellite data, with average residuals of <1% at the different sites when the OMI view was within 50 km from the Pandora location and OMI-measured cloud fraction was <0.2. The frequent and continuous measurements by Pandora revealed significant short-term (hourly) temporal changes in TCO, not possible to capture by sun-synchronous satellites, such as OMI, alone.

Ozone↗