At least 73 records · Page 4

Functional Task Test: 2. Spaceflight-Induced Cardiovascular Change and Recovery During NASA's Functional Task Test

The overall objective of the functional task test (FTT) is to correlate spaceflight-induced physiological adaptations with changes in performance of high priority exploration mission-critical tasks. This presentation will focus on the recovery from fall/stand test (RFST), which measures the cardiovascular response to the transition from the prone posture (simulated fall) to standing in normal gravity, as well as heart rate (HR) during 11 functional tasks. As such, this test describes some aspects of spaceflight-induced cardiovascular deconditioning and the course of recovery in Space Shuttle and International Space Station (ISS) astronauts. The sensorimotor and neuromuscular components of the FTT are described in two separate abstracts: Functional Task Test 1 and 3.

Phillips, Tiffany↗

Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 1

Electrical characterization and qualification tests were performed on the RCA MWS5001D, 1024 by 1-bit, CMOS, random access memory. Characterization tests were performed on five devices. The tests included functional tests, AC parametric worst case pattern selection test, determination of worst-case transition for setup and hold times and a series of schmoo plots. The qualification tests were performed on 32 devices and included a 2000 hour burn in with electrical tests performed at 0 hours and after 168, 1000, and 2000 hours of burn in. The tests performed included functional tests and AC and DC parametric tests. All of the tests in the characterization phase, with the exception of the worst-case transition test, were performed at ambient temperatures of 25, -55 and 125 C. The worst-case transition test was performed at 25 C. The preburn in electrical tests were performed at 25, -55, and 125 C. All burn in endpoint tests were performed at 25, -40, -55, 85, and 125 C.

Klute, A.↗

Assessment of Postflight Locomotor Performance Utilizing a Test of Functional Mobility: Strategic and Adaptive Responses

Space flight induces adaptive modification in sensorimotor function, allowing crewmembers to operate in the unique microgravity environment. This adaptive state, however, is inappropriate for a terrestrial environment. During a re-adaptation period upon their return to Earth, crewmembers experience alterations in sensorimotor function, causing various disturbances in perception, spatial orientation, posture, gait, and eye-head coordination. Following long duration space flight, sensorimotor dysfunction would prevent or extend the time required to make an emergency egress from the vehicle; compromising crew safety and mission objectives. We are investigating two types of motor learning that may interact with each other and influence a crewmember's ability to re-adapt to Earth's gravity environment. In strategic learning, crewmembers make rapid modifications in their motor control strategy emphasizing error reduction. This type of learning may be critical during the first minutes and hours after landing. In adaptive learning, long-term plastic transformations occur, involving morphological changes and synaptic modification. In recent literature these two behavioral components have been associated with separate brain structures that control the execution of motor strategies: the strategic component was linked to the posterior parietal cortex and the adaptive component was linked to the cerebellum (Pisella, et al. 2004). The goal of this paper was to demonstrate the relative contributions of the strategic and adaptive components to the re-adaptation process in locomotor control after long duration space flight missions on the International Space Station (ISS). The Functional Mobility Test (FMT) was developed to assess crewmember s ability to ambulate postflight from an operational and functional perspective. Sixteen crewmembers were tested preflight (3 sessions) and postflight (days 1, 2, 4, 7, 25) following a long duration space flight (approx 6 months) on the ISS. We have further analyzed the FMT data to characterize strategic and adaptive components during the postflight readaptation period. Crewmembers walked at a preferred pace through an obstacle course set up on a base of 10 cm thick medium density foam (Sunmate Foam, Dynamic Systems, Inc., Leicester, NC). The 6.0m X 4.0m course consisted of several pylons made of foam; a Styrofoam barrier 46.0cm high that crewmembers stepped over; and a portal constructed of two Styrofoam blocks, each 31cm high, with a horizontal bar covered by foam and suspended from the ceiling which was adjusted to the height of the crewmember s shoulder. The portal required crewmembers to bend at the waist and step over a barrier simultaneously. All obstacles were lightweight, soft and easily knocked over. Crewmembers were instructed to walk through the course as quickly and as safely as possible without touching any of the objects on the course. This task was performed three times in the clockwise direction and three times in the counterclockwise direction that was randomly chosen. The dependent measures for each trial were: time to complete the course (seconds) and the number of obstacles touched or knocked down. For each crewmember, the time to complete each FMT trial from postflight days 1, 2, 4, 7 and 25 were further analyzed. A single logarithmic curve using a least squares calculation was fit through these data to produce a single comprehensive curve (macro). This macro curve composed of data spanning 25 days, illustrates the re-adaptive learning function over the longer time scale term. Additionally, logarithmic curves were fit to the 6 data trials within each individual post flight test day to produce 5 separate daily curves. These micro curves, produced from data obtained over the course of minutes, illustrates the strategic learning function exhibited over a relative shorter time scale. The macro curve for all subjects exhibited adaptive motor learning patterns over the 25 day period. Howev, 9/16 crewmembers exhibited significant strategic motor learning patterns in their micro curves, as defined by m > 1 in the equation of the line y=m*LN(x) +b. These data indicate that postflight recovery in locomotor function involves both strategic and adaptive mechanisms. Future countermeasures will be designed to enhance both recovery processes.

Warren, L. E.↗

Spin Splitting Energy of Transition Metals: A New, More Affordable Wave Function Benchmark Method and Its Use to Test Density Functional Theory

Accurately predicting the spin splitting energy of chemical species is important for understanding their reactivity and magnetic properties, but it is very challenging, especially for molecules containing transition metals. One impediment to progress is the scarcity of accurate benchmark data. Here we report a set of calculations designed to yield reliable benchmarks for simple transition-metal complexes that can be used to test density functional methods that are affordable for large systems of more practical interest. Various wave function methods are tested against experiment for Fe 2+ , Fe 3+ , and Co 3+ , including CASSCF, CASPT2, CASPT3, MRCISD, MRCISD+Q, ACPF, AQCC, CCSD(T), and CASPT2/CCSD(T) and also a new method called CASPT2.5, which is performed by taking the average of the CASPT2 and CASPT3 energies. Furthermore, we find that MRCISD+Q, ACPF, and AQCC require smaller active spaces for good accuracy than are required by CASPT2 and CASPT3, and this aspect may be important for calculations on larger molecules; here we find that CASPT2.5 extrapolated to a complete basis set is the most suitable method—in terms of computational cost and in terms of accuracy on monatomic systems—and therefore we chose this method for molecular benchmarks. Then Kohn–Sham density functional calculations with 60 exchange-correlation functionals are tested for FeF 2 , FeCl 2 , and CoF 2 . We find that MN15-L, M06-SX, and revM06 have very good agreement with CASPT2.5 benchmarks in terms of both the spin splitting energy and the optimized geometry for each spin state. In addition, we recommend def2-TZVP as the most suitable basis set to perform density functional calculations for molecular spin splitting energies; extra polarization functions in the basis set do not help to increase the accuracy of the spin splitting energy in KS calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functional Task Test: 1. Sensorimotor changes Associated with Postflight Alterations in Astronaut Functional Task Performance

Space flight is known to cause alterations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. This presentation will focus on the sensorimotor contributions to postflight functional performance.

Bloomberg, J. J.↗

High-throughput functional trait testing for bacterial pathogens

Functional traits are characteristics that affect the fitness and metabolic function of a microorganism. There is growing interest in using high-throughput methods to characterize bacterial pathogens based on functional virulence traits. Traditional methods that phenotype a single organism for a single virulence trait can be time consuming and labor intensive. Alternatively, machine learning of whole-genome sequences (WGS) has shown some success in predicting virulence. However, relying solely on WGS can miss functional traits, particularly for organisms lacking classical virulence factors. We propose that high-throughput assays for functional virulence trait identification should become a prominent method of characterizing bacterial pathogens on a population scale. This work is critical as we move from compiling lists of bacterial species associated with disease to pathogen-agnostic approaches capable of detecting novel microbes. We discuss six key areas of functional trait testing and how advancing high-throughput methods could provide a greater understanding of pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of tests for vestibular function

Vestibular testing methodologies are examined in terms of their clinical value and applicability to the assessment of astronaut candidates and human responses to microgravity. Classical and novel testing approaches are examined in terms of nine functions such as otolith organs, vestibular neural processing, and ocular motor systems. The tests reviewed include the basic vestibular-function test battery, postural stability testing, visual-vestibular interaction, reactions to off-axis rotation, and vestibular evoked responses. The basic test battery is shown to be essential for astronaut and inertial-environment baseline-data evaluations, whereas the newer and research tests are only recommended in special cases. Stimulus rearrangement and motion-sickness tests are indicated for testing adaptation to inertial environments. Postural stability and visual-vestibular interaction are recommended for evaluating one's suitability for being an astronaut.

Source record↗

Electrical Characterization of the RCA CDP1822SD Random Access Memory, Volume 1, Appendix a

Electrical characteristization tests were performed on 35 RCA CDP1822SD, 256-by-4-bit, CMOS, random access memories. The tests included three functional tests, AC and DC parametric tests, a series of schmoo plots, rise/fall time screening, and a data retention test. All tests were performed on an automated IC test system with temperatures controlled by a thermal airstream unit. All the functional tests, the data retention test, and the AC and DC parametric tests were performed at ambient temperatures of 25 C, -20 C, -55 C, 85 C, and 125 C. The schmoo plots were performed at ambient temperatures of 25 C, -55 C, and 125 C. The data retention test was performed at 25 C. Five devices failed one or more functional tests and four of these devices failed to meet the expected limits of a number of AC parametric tests. Some of the schmoo plots indicated a small degree of interaction between parameters.

Klute, A.↗

Further Developments in the MLPG Method for Beam Problems

An accurate and yet simple Meshless Local Petrov-Galerkin (MLPG) formulation for analyzing beam problems is presented. In the formulation, simple weight functions are chosen as test functions as in the conventional MLPG method. Linear test functions are also chosen, leading to a variation of the MLPG method that is computationally efficient compared to the conventional implementation. The MLPG method is evaluated by applying the formulation to a variety of patch tests, thin beam problems, and problems with load discontinuities. The formulation successfully reproduces exact solutions to machine accuracy when higher order power and spline functions are chosen as test functions or when the linear test function is used, and when constructing the trial functions, the order of the basis function is properly balanced by the order of the weight function. For mixed boundary value problems, deflections, slopes, moments, and shear forces are calculated to the same accuracy by the MLPG method without the use of elaborate post-processing techniques. Problems with load discontinuities require special care - when a reasonable number of nodes are used, the method yields very accurate results.

Raju, I. S.↗

On testing VLSI chips for the big Viterbi decoder

A general technique that can be used in testing very large scale integrated (VLSI) chips for the Big Viterbi Decoder (BVD) system is described. The test technique is divided into functional testing and fault-coverage testing. The purpose of functional testing is to verify that the design works functionally. Functional test vectors are converted from outputs of software simulations which simulate the BVD functionally. Fault-coverage testing is used to detect and, in some cases, to locate faulty components caused by bad fabrication. This type of testing is useful in screening out bad chips. Finally, design for testability, which is included in the BVD VLSI chip design, is described in considerable detail. Both the observability and controllability of a VLSI chip are greatly enhanced by including the design for the testability feature.

Hsu, I. S.↗

NASA's Functional Task Test: Providing Information for an Integrated Countermeasure System

Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goals of the Functional Task Test (FTT) study were to determine the effects of spaceflight on functional tests that are representative of critical exploration mission tasks and to identify the key physiological factors that contribute to decrements in performance. The FTT was comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and ISS crewmembers participated in this study. Additionally, we conducted a supporting study using the FTT protocol on subjects before and after 70 days of 6 head-down bed rest. The bed rest analog allowed us to investigate the impact of body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare them with the results obtained in our spaceflight study. Spaceflight data were collected on three sessions before flight, on landing day (Shuttle only) and 1, 6 and 30 days after landing. Bed rest subjects were tested three times before bed rest and immediately after getting up from bed rest as well as 1, 6, and 12 days after reambulation. We have shown that for Shuttle, ISS and bed rest subjects, functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. These changes in functional performance were paralleled by similar decrements in sensorimotor tests designed to specifically assess postural equilibrium and dynamic gait control. Bed rest subjects experienced similar deficits both in functional tests with balance challenges and in sensorimotor tests designed to evaluate postural and gait control as spaceflight subjects indicating that body support unloading experienced during spaceflight plays a central role in post-flight alteration of functional task performance. To determine how differences in body-support loading experienced during in-flight treadmill exercise affect postflight functional performance, the loading history for each subject during in-flight treadmill (T2) exercise was correlated with postflight measures of performance. ISS crewmembers who walked on the treadmill with higher pull-down loads had enhanced post-flight performance on tests requiring mobility. Taken together the spaceflight and bed rest data point to the importance of supplementing inflight exercise countermeasures with balance and sensorimotor adaptability training. These data also support the notion that inflight treadmill exercise performed with higher body loading provides sensorimotor benefits leading to improved performance on functional tasks that require dynamic postural stability and mobility.

Bloomberg, J. J.↗

Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight

The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (p<0.05). Bench press total work was also significantly impaired, although maximal isometric force and power were not significantly affected. No changes were noted for measurements of central activation or force steadiness. Results for ISS crew were not analyzed due to the current small sample size. DISCUSSION: Significant reductions in lower body muscle performance metrics were observed in returning Shuttle crew and these adaptations are likely contributors to impaired functional tasks that are ambulatory in nature (See abstract Functional Task Test: 1). Interestingly, no significant changes in central activation capacity were detected. Therefore, impairments in muscle function in response to short-duration space flight are likely myocellular rather than neuromotor in nature.

Ryder, Jeffrey W.↗

Analytical evaluation of a surface integral expressing the coupling between interior and exterior volumes in a FE-IE approach

Recently an approach which combines the finite element technique and an integral equation to determine the fields scattered by inhomogeneous bodies of complicated shape has been proposed. Basically, a mathematical surface which encloses the scatterers is introduced, thus dividing the space into an interior and an exterior volume, in which the finite element technique and an integral equation for EM scattering, respectively, are applied. The integral equation is set up for the tangential components of the fields at the surface, while the interior volume the unknowns are the total fields. Continuity of the tangential fields at the boundary, as required by Maxwell's equations, is imposed, thus coupling the two methods to obtain a consistent solution. The coupling term is expressed by a surface integral formed by the dot product of a FE basis function and an IE testing function, or viceversa. By choosing the boundary to be a surface of revolution and by making a convenient selection of IE basis (testing) functions, it is possible to evaluate the integrals analytically on surfaces such as curved triangles, curved quadrilaterals and curved pentagons. We will illustrate the salient steps involved in setting up and carrying out these integrals and discuss what class of basis (testing) functions and analytic surfaces of revolution they are applicable to. Analytic calculations offer the advantage of better accuracy than purely numerical ones, and, when combined with them, often shed light on issues of numerical convergence and limiting values. Furthermore, they may reduce computation time and storage requirements.

Zuffada, C.↗

On testing of functionally equivalent components of fault-tolerant software

Six functionally equivalent programs were tested with specification based random and extremal/special value (ESV) test cases. Statement and branch coverage were used to measure and compare the attained testing effectiveness. It was observed that both measures reached a nearly steady state value after 25 to 75 random test cases. Coverage saturation curves appear to follow an exponential growth model. However, the steady state values for branch coverage of different components, but the same input cases, differed by as much as 22 percent. The effect is the result of the differences in the detailed structure of the components. Improvement in coverage provided by the random test data, after the ESV cases were executed, was only about 1 percent. Results indicate that extensive random testing can be a process of diminishing returns, and that in the FTS context functional ('black box') testing can provide a very uneven execution coverage of the functionally equivalent software, and therefore should be supplemented by structure based testing.

Vouk, Mladen A.↗

Examining functional acceptance testing with structural coverage metrics

Functionally generated acceptance tests are examined using structural coverage metrics. A method of comparing acceptance tests and operational usage was generated. Acceptance tests are prepresentative of operational usage except for the mix of statement types. Structural coverage metrics may provide insight into software faults.

Ramsey, J.↗

Design Process of a Pressure Transducer Vibration Fixture

This paper details the iterative design cycle of a fixture used to mount two types of pressure transducers for vibration testing which allows for functional testing without the removal of the transducers. The objective of the fixture is to prove that the pressure transducers can survive vibrations induced during launch. This would increase the Technology Readiness Level of the pressure transducers which is a requirement for the Lunar Advanced Volatile Analysis subsystem preliminary design review. During the design process, additive manufacturing is considered as a manufacturing method of the fixture as a way to investigate the use of additive manufacturing for the final flight version of the Fluid Sub System manifold. It is ultimately shown that the added ability to perform functional testing and optimization for additive manufacturing made the fixture less than ideal for vibration testing. It is determined that the best option is to design and manufacture a traditional vibration fixture without the ability to perform functional testing of components while attached and a separate part to investigate the application of additive manufacturing to the Fluid Subsystem manifold.

Gilstrap, Andrew↗

A vestibular phenotype for Waardenburg syndrome?

OBJECTIVE: To investigate vestibular abnormalities in subjects with Waardenburg syndrome. STUDY DESIGN: Retrospective record review. SETTING: Tertiary referral neurotology clinic. SUBJECTS: Twenty-two adult white subjects with clinical diagnosis of Waardenburg syndrome (10 type I and 12 type II). INTERVENTIONS: Evaluation for Waardenburg phenotype, history of vestibular and auditory symptoms, tests of vestibular and auditory function. MAIN OUTCOME MEASURES: Results of phenotyping, results of vestibular and auditory symptom review (history), results of vestibular and auditory function testing. RESULTS: Seventeen subjects were women, and 5 were men. Their ages ranged from 21 to 58 years (mean, 38 years). Sixteen of the 22 subjects sought treatment for vertigo, dizziness, or imbalance. For subjects with vestibular symptoms, the results of vestibuloocular tests (calorics, vestibular autorotation, and/or pseudorandom rotation) were abnormal in 77%, and the results of vestibulospinal function tests (computerized dynamic posturography, EquiTest) were abnormal in 57%, but there were no specific patterns of abnormality. Six had objective sensorineural hearing loss. Thirteen had an elevated summating/action potential (>0.40) on electrocochleography. All subjects except those with severe hearing loss (n = 3) had normal auditory brainstem response results. CONCLUSION: Patients with Waardenburg syndrome may experience primarily vestibular symptoms without hearing loss. Electrocochleography and vestibular function tests appear to be the most sensitive measures of otologic abnormalities in such patients.