Search NASA⌕ Search

SEARCH · Search NASA

Results for “therapy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dual-Responsive Turn-On T 1 Imaging-Guided Mild Photothermia for Precise Apoptotic Cancer Therapy

Apoptosis has gained increasing attention in cancer therapy as an intrinsic signaling pathway, which leads to minimal leakage of waste products from a dying cell to neighboring normal cells. Among various stimuli to trigger apoptosis, mild hyperthermia is attractive but confronts limitations of non-specific heating and acquired resistance from elevated expression of heat shock proteins. Here, a dual-stimulation activated turn-on T 1 imaging-based nanoparticulate system (DAS) is developed for mild photothermia (≈43 °C)-mediated precise apoptotic cancer therapy. In the DAS, a superparamagnetic quencher (ferroferric oxide nanoparticles, Fe 3 O 4 NPs) and a paramagnetic enhancer (Gd-DOTA complexes) are connected via the N6-methyladenine (m 6 A)-caged, Zn 2+ -dependent DNAzyme molecular device. The substrate strand of the DNAzyme contains one segment of Gd-DOTA complex-labeled sequence and another one of HSP70 antisense oligonucleotide. When the DAS is taken up by cancer cells, overexpressed fat mass and obesity-associated protein (FTO) specifically demethylates the m 6</-sup>A group, thereby activating DNAzymes to cleave the substrate strand and simultaneously releasing Gd-DOTA complex-labeled oligonucleotides. The restored T 1 signal from the liberated Gd-DOTA complexes lights up the tumor to guide the location and time of deploying 808 nm laser irradiation. Afterward, locally generated mild photothermia works in concert with HSP70 antisense oligonucleotides to promote apoptosis of tumor cells. This highly integrated design provides an alternative strategy for mild hyperthermia-mediated precise apoptotic cancer therapy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Trends in Radiation Therapy for Bone Metastases, 2015 to 2017: Choosing Wisely in the Era of Complex Radiation

Guidelines recommend short-course (≤10 fractions) external-beam radiation therapy (EBRT) for bone metastases. Stereotactic body radiation therapy (SBRT) may also improve outcomes; however, routine use is not recommended outside clinical trials. We assessed national radiation therapy trends in complex techniques for bone metastases and associated expenditures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound controlled mechanophore activation in hydrogels for cancer therapy

Significance Biomedical application of mechanophores is the next frontier in polymer mechanochemistry. We report the concept, mechanochemical dynamic therapy (MDT), that utilizes remote, ultrasound-triggered mechanophore activation to enable anticancer activities. We selected an azo-based mechanophore to generate reactive free radicals (FRs) under the control of high-intensity focused ultrasound (HIFU), which subsequently produced ROS. We investigated two sets of in vitro mouse cancer models: 1) melanoma (B16F10) and 2) breast cancer (E0771). Inhibition of growth and decreases in viabilities of both B16F10 and E0771 were observed in correlation to the release of ROS by mechanophore activation. By circumventing the known issues in photodynamic therapy and sonodynamic therapy, we anticipate MDT to be a powerful anticancer tool complementary to other existing cancer treatments.

60 APPLIED LIFE SCIENCES↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

KiT-RT: An Extendable Framework for Radiative Transfer and Therapy

Here, in this article, we present Kinetic Transport Solver for Radiation Therapy (KiT-RT), an open-source C++-based framework for solving kinetic equations in therapy applications available at https://github.com/CSMMLab/KiT-RT . This software framework aims to provide a collection of classical deterministic solvers for unstructured meshes that allow for easy extendability. Therefore, KiT-RT is a convenient base to test new numerical methods in various applications and compare them against conventional solvers. The implementation includes spherical harmonics, minimal entropy, neural minimal entropy, and discrete ordinates methods. Solution characteristics and efficiency are presented through several test cases ranging from radiation transport to electron radiation therapy. Due to the variety of included numerical methods and easy extendability, the presented open-source code is attractive for both developers, who want a basis to build their numerical solvers, and users or application engineers, who want to gain experimental insights without directly interfering with the codebase.

97 MATHEMATICS AND COMPUTING↗

Towards modeling phage therapy

Patients infected with life-threatening multi-drug resistant (MDR) bacteria have been treated with cocktails of bacteriophages. This is a complicated form of personalized medicine as the phages given to a patient have to be selected beforehand on the basis of their lytic capacity of the infecting bacteria. Because bacteria rapidly become resistant, the evolution of resistance to a diverse cocktail of phages is a complicated dynamical process, during which competing bacterial strains replace one another by accumulating several resistance mechanisms, each of which may involve a fitness cost. As a consequence, it is typically not known why a particular phage therapy succeeded or failed, and how one can optimize the composition of the cocktails to maximize the rate of success. To improve upon this, we extend an existing in vivo -calibrated mouse model into a novel mathematical model for the human situation, and include multiple phages infecting multiple bacterial strains, differing in their resistance to each of the phages. We adjust several parameter estimates of the bacterial model to the human situation, and use the model to describe a successful case of phage therapy involving several cocktails, each containing several phages. In the model, treatment success crucially depended on pretreatment resistance levels, and on the diversity and the timing of the cocktails. Once an appropriate cocktail is found, it is less important to further optimize the infection rates of the phages. Resistant bacterial strains expand rapidly when sensitive strains decline, and the higher the infectivity of the phages, the faster resistant strains expand. Because resistance evolves rapidly, it is best to provide a diverse set of phages right from the start of therapy, i.e., to hit hard and early, and create a high genetic barrier to bacterial resistance.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding early HIV-1 rebound dynamics following antiretroviral therapy interruption: The importance of effector cell expansion

Most people living with HIV-1 experience rapid viral rebound once antiretroviral therapy is interrupted; however, a small fraction remain in viral remission for an extended duration. Understanding the factors that determine whether viral rebound is likely after treatment interruption can enable the development of optimal treatment regimens and therapeutic interventions to potentially achieve a functional cure for HIV-1. We built upon the theoretical framework proposed by Conway and Perelson to construct dynamic models of virus-immune interactions to study factors that influence viral rebound dynamics. We evaluated these models using viral load data from 24 individuals following antiretroviral therapy interruption. The best-performing model accurately captures the heterogeneity of viral dynamics and highlights the importance of the effector cell expansion rate. Our results show that post-treatment controllers and non-controllers can be distinguished based on the effector cell expansion rate in our models. Furthermore, these results demonstrate the potential of using dynamic models incorporating an effector cell response to understand early viral rebound dynamics post-antiretroviral therapy interruption.

60 APPLIED LIFE SCIENCES↗

Incidence and predictors of loss to follow-up among adult patients receiving antiretroviral therapy in Central Ethiopia: a multi-center retrospective cohort study

Background: Globally, loss to follow-up (LTFU) remains a significant public health concern despite the rapid expansion of antiretroviral medication programs. It is a significant cause of treatment failure and threatens the enhancement of HIV treatment outcomes among patients on antiretroviral therapy (ART). However, there is a paucity of evidence on its incidence and predictors in Ethiopia. Thus, this study aimed to examine the incidence and predictors of LTFU among adult HIV patients receiving ART at hospitals in Central Ethiopia. Methods: A multi-centered facility-based retrospective cohort study was conducted among 432 randomly selected adult patients who received antiretroviral therapy. Data were entered into EpiData version 3.1 and exported to Stata version 14 for analysis. The Kaplan–Meier failure function was employed to determine the overall failure estimates, and the log-rank test was used to compare the probability of failure among the different categories of variables. The Cox proportional hazard model was used to identify independent predictors of LTFU. Results: Overall, 172 (39.8%) study participants were lost to follow-up over the 10-year follow-up period with an incidence rate of 8.12 (95% CI: 7.11, 9.09) per 1,000 person-months. Undisclosed HIV status (AHR: 1.96, 95% CI: 1.14, 3.36), not able to work (AHR: 1.84, 95% CI: 1.13, 2.22), opportunistic infections (AHR: 3.13, 95% CI: 2.17, 4.52), CD4 < 200 cell/mL (AHR: 1.95, 95% CI: 1.18, 3.21), not receiving isoniazid preventive therapy (IPT) (AHR: 2.57, 95% CI: 1.62, 4.06), not participating in clubs (AHR: 1.68, 95% CI: 1.10, 2.22), side effects of drugs (AHR: 1.44, 95% CI: 1.02, 2.04), and high viral load (AHR: 3.15, 95% CI: 1.81, 5.47) were identified as significant predictors of loss to follow-up. Conclusion: In this study, the incidence of LTFU was high. The focus should be on creating awareness and prevention programs that aim to reduce loss to follow-up by continuing counseling, especially on the negative effects of loss to follow-up and the benefits of ART care.

60 APPLIED LIFE SCIENCES↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Heavy Ion Minibeam Therapy: Side Effects in Normal Brain

The purpose of this work was to investigate whether minibeam therapy with heavy ions might offer improvements of the therapeutic ratio for the treatment of human brain cancers. To assess neurotoxicity, we irradiated normal juvenile rats using 120 MeV lithium-7 ions at an absorbed integral dose of 20 Gy. Beams were configured either as a solid parallel circular beam or as an array of planar parallel minibeams having 300-micron width and 1-mm center-to-center spacing within a circular array. We followed animals for 6 months after treatment and utilized behavioral testing and immunohistochemical studies to investigate the resulting cognitive impairment and chronic pathologic changes. We found both solid-beam therapy and minibeam therapy to result in cognitive impairment compared with sham controls, with no apparent reduction in neurotoxicity using heavy ion minibeams instead of solid beams under the conditions of this study.

60 APPLIED LIFE SCIENCES↗

Radiation Therapy–Induced Changes of the Nasopharyngeal Commensal Microbiome in Nasopharyngeal Carcinoma Patients

The human commensal microbiome has been suggested to be involved in the regulation of response to anticancer therapies. However, little is known regarding changes in commensal microbes in patients with cancer during radiation therapy. We conducted a prospective, longitudinal proof-of-concept cohort study with patients with newly diagnosed nasopharyngeal carcinoma (NPC) who underwent radiation therapy-based treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Pneumonitis and Outcomes After Mediastinal Proton Therapy for Relapsed/Refractory Lymphoma: A PTCOG and PCG Collaboration

Despite high response rates, there has been reluctance to use radiation therapy for patients with relapsed/refractory (r/r) Hodgkin (HL) or aggressive non-Hodgkin lymphoma (NHL) given concerns for subacute and late toxicities. Symptomatic pneumonitis, a subacute toxicity, has an incidence of 17% to 24% (≥grade 2) even with intensity modulated radiation therapy. Proton therapy (PT), which has no exit radiation dose, is associated with a lower dose to lung compared with other radiation techniques. As risk of radiation pneumonitis is associated with lung dose, we evaluated whether pneumonitis rates are lower with PT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NRG Oncology/RTOG Consensus Guidelines for Delineation of Clinical Target Volume for Intensity Modulated Pelvic Radiation Therapy in Postoperative Treatment of Endometrial and Cervical Cancer: An Update

Accurate target definition is critical for the appropriate application of radiation therapy. In 2008, the Radiation Therapy Oncology Group (RTOG) published an international collaborative atlas to define the clinical target volume (CTV) for intensity modulated pelvic radiation therapy in the postoperative treatment of endometrial and cervical cancer. The current project is an updated consensus of CTV definitions, with removal of all references to bony landmarks and inclusion of the para-aortic and inferior obturator nodal regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Health-Related Quality of Life Outcomes in Head and Neck Cancer: Results From a Prospective, Real-World Data Study With Brazilian Patients Treated With Intensity Modulated Radiation Therapy, Conformal and Conventional Radiation Techniques

To compare global health-related quality of life (HRQoL) and overall survival (OS) in patients with head and neck cancer treated with intensity modulated radiation therapy (IMRT), conformal radiation therapy (3DCRT) or conventional radiation therapy (2DRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness Analysis of Stereotactic Ablative Radiation Therapy in Patients With Oligometastatic Cancer

The Stereotactic Ablative Radiation therapy for Comprehensive Treatment of Oligometastatic Tumors phase 2 randomized clinical trial found that stereotactic ablative radiation therapy (SABR) improved outcomes among cancer patients with oligometastatic disease. Yet, the cost of SABR along with the large number of patients with oligometastatic disease raises the important question of value. This study sought to evaluate the cost-effectiveness of the addition of SABR compared with standard therapy alone among cancer patients with oligometastatic disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Randomized Trial of the Influence of Music on Anxiety in Patients Starting Radiation Therapy for Cancer

One of the most downloaded articles in 2017 from the International Journal of Radiation Oncology, Biology, and Physics was a study suggesting that music therapy during radiation therapy (RT) simulation substantially reduces anxiety. To further evaluate the potential of music's clinical efficacy in the context of radiation therapy, we conducted a randomized trial evaluating the influence of genre-based music chosen by the study participant on anxiety during the first RT treatment session with a method that is applicable to routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcomes of a Randomized Trial of Adaptive Plan-of-the-Day Treatment in Patients Receiving Ultra-hypofractionated Weekly Radiation Therapy for Bladder Cancer

Hypofractionated radiation therapy can be used to treat patients with muscle-invasive bladder cancer unable to have radical therapy. Toxicity is a key concern, but adaptive plan-of the day (POD) image-guided radiation therapy delivery could improve outcomes by minimizing the volume of normal tissue irradiated. The HYBRID trial assessed the multicenter implementation, safety, and efficacy of this strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗