Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Commercial aluminum powders, Part I: Particle size characterization and slow heating rate thermal analysis.

We characterized nine commercial aluminum (Al) powders using several methods to measure particle characteristics and thermal analysis, with the goal to understand how these parameters influence energy release. Although it is well-known that lot-to-lot variations in commercial nanoparticles are common, the Al powders were more heterogeneous than anticipated – both with regards to particle size distributions and impurities. Manufacturer specifications – often quoted in the literature without confirmation – were not always accurate for the specific sample lots we investigated. In several cases, different conclusions could be drawn from individual particle size techniques; a combination of multiple techniques provides a clearer picture of the powder properties. Thorough characterization of Al powders is required prior to interpretation of experimental results from a variety of applications. In particular, previous studies have shown contradictory results on the influence of Al on detonation performance, perhaps partially due to insufficient characterization of the Al powders themselves.

36 MATERIALS SCIENCE↗

Synergistic Heat Pumped Thermal Storage and Flexibly Carbon Capture System

As the U.S. grid evolves toward a lower-carbon system, fossil generation assets need to operate in energy markets with high variable renewable energy (VRE) penetration while also decreasing carbon emissions. Current carbon capture and storage (CCS) technologies suffer from high capital cost and an inability to operate flexibly during periods of oscillating demand. The ARPA-E FLECCS Program Phase 1 was created to fund designing and optimizing innovative CCS processes that enable flexibility on a high-VRE grid. To address this need, the Colorado State University (CSU) Team won funding to design a synergized system of thermal energy storage, power generation, and flexible carbon capture to enable breakthrough system performance that achieves an LCOE <$75/MWh with >99% capture rate. This approach will target new or existing natural gas combined cycle power plants. The proposed design utilizes novel hot and cold thermal energy storage (TES) technologies that store low-cost, off-peak electricity as thermal energy to power CCS solvent regeneration and boost plant output during periods of peak demand. The design provides an overall optimized net present value (NPV) by maximizing low carbon power to grid while prices are highest using Storworks Power’s concrete TES technology. The team also capitalizes on decades of ION Clean Energy’s (ION) development in low cost and flexible pioneering solvent technology, which has proven reductions in energy consumption and overall cost of 28% and 38%, respectively, compared with state-of-the-art CCS.

20 FOSSIL-FUELED POWER PLANTS↗

Experimental Investigation of a Phase Change Material Charged Serpentine Heat Exchanger with Louvered Fins

Phase change material heat exchangers (PCM-HX) can be used as a latent heat thermal energy storage (LHTES) component in heat pump applications to further enhance the efficiency of a heat pump as well as to yield financial savings by peak-load shifting. In this paper, a low-cost commercially available aluminum serpentine heat exchanger with louvered fins was experimentally investigated to check its thermal performance as a PCM-HX. A transparent rectangular box fabricated from acrylic plates served as a PCM container. Two cameras were used to capture the phase change process of the PCM on the front and top sides of the container during the experiment. A total of 88 installed temperature sensors throughout the test setup and a mass flow meter enabled a quantitative analysis of the PCM-HX as well. The energy balance deviation between the estimated theoretical and experimentally calculated PCM storage was ±14% considering the often-neglected heat loss and thermal mass of the PCM-HX. PCM temperature profiles, charge and discharge rates, and energy densities under different test conditions were also investigated.

42 ENGINEERING↗

Experimentally Measured Thermal Masses of Adsorption Heat Exchangers

The thermal masses of components influence the performance of many adsorption heat pump systems. However, typically when experimental adsorption systems are reported, data on thermal mass are missing or incomplete. This work provides original measurements of the thermal masses for experimental sorption heat exchanger hardware. Much of this hardware was previously reported in the literature, but without detailed thermal mass data. The data reported in this work are the first values reported in the literature to thoroughly account for all thermal masses, including heat transfer fluid. The impact of thermal mass on system performance is also discussed, with detailed calculation left for future work. The degree to which heat transfer fluid contributes to overall effective thermal mass is also discussed, with detailed calculation left for future work. This work provides a framework for future reporting of experimental thermal masses. The utilization of this framework will enrich the data available for model validation and provide a more thorough accounting of adsorption heat pumps.

30 DIRECT ENERGY CONVERSION↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community Geothermal: Energy, Cost, and Carbon Modeling for District Design - Ann Arbor, MI

This data includes results on an analysis of existing and projected energy, cost, and carbon for the City of Ann Arbor - District Geothermal Design and Deployment to Equitably Decarbonize Low Income Neighborhoods in Ann Arbor project. The scope of the project includes designing and implementing a geothermal district heating and cooling system that reduces thermal heating and cooling load by 75% and greenhouse gas emissions by 40% in the project area (262 households, 6 commercial buildings). The existing neighborhood was modeled using Design Builder, an EnergyPlus software, to understand the current energy load. The energy model was then flipped to reflect the designed district geothermal heating and cooling system to project the effect on energy, carbon, and cost. This dataset includes the analysis files utilized and created for this study. There are 3 categories of data: 1) existing/benchmarking, 2) energy modeling, and 3) post processed calculations. This follows the methodology and process of the project team, which is fully explained in file 00_Technical Economic Environmental Assessment. All uses of data are referenced throughout this assessment to their respective files included below.

15 GEOTHERMAL ENERGY↗

Investigation of Corrosion of 304 Stainless, Inconel 625, and Haynes 230 in a Chloride-Salt-Based Thermal Storage Medium

One of the critical challenges for latent heat thermal energy storage systems in concentrating solar power applications is corrosion of metallic alloys as containment and heat transfer fluid tube materials in corrosive salts at high temperatures. In this study, the effects of MgCl 2 on the corrosion of stainless steel 304, Inconel 625, and Haynes 230 alloys were investigated through embedded metal samples in the graphite foam/MgCl 2 storage medium. Four experimental testing modules were fabricated, and experimental tests were conducted under controlled environment by heating the testing modules to and keeping them at 750 °C for 100, 200, 500, and 1000 h. The estimated corrosion rates based on the weight losses for stainless steel 304, Inconel 625, and Haynes 230 were 94, 9, and 8 μm/year, respectively. The fitted equations for the loss of the thickness as functions of the exposure time show that the corrosion rates decrease with the exposure time. Additionally, the results on the corrosion zones or depths and chromium segregation ranges of the experimental samples are also presented.

36 MATERIALS SCIENCE↗

Thermal Charging Rate of Composite Wax-Expanded Graphite Phase Change Materials

Phase change materials (PCMs) are valuable for their ability to store heat nearly isothermally around their phase transition temperature. PCMs are at the core of latent heat thermal energy storage (LHTES) systems, which provide the ability to buffer high thermal loads or decouple the time when heating or cooling is needed from when it is produced. Thermal charging and discharging of LHTES systems often employ a constant temperature source, and the rate at which heat can be exchanged is dependent on the thermophysical properties of the PCM. For graphite composite PCMs, the high thermal conductivity of the graphite enables an increased heat transfer rate through the material, but its presence displaces PCM which reduces the effective volumetric latent heat of the composite relative to the pure PCM. This results in a tradeoff between thermal power and volumetric energy storage capacity. The thermal charging rate is the average thermal energy stored in the material for some elapsed time. In this study, composite PCMs of compressed expanded natural graphite (CENG) and n-Octadecane are studied. Samples with varying CENG mass fractions were synthesized and the thermal charging rate was measured under a constant temperature boundary condition. For evaluation of the expanded graphite-PCM composite, one boundary of the material was exposed to a 50°C constant temperature plate, above the 27.5°C melting temperature of the PCM. The melting front progression [mm-s-1] and the thermal charging rate [W-cm-2] of the PCM were determined, and the results were compared with analytical predictions for the 1-D semi-infinite phase change. For CENG addition up to 5.75% mass fraction, a 450% thermal conductivity increase was observed with a 5% decrease in volumetric energy density as compared to pure octadecane. The average thermal charging rate was increased by over 430% for the melt to penetrate a depth of 22 mm. The experimental results matched analytical predictions, indicating that higher CENG fractions can be evaluated using analytical approaches.

Hirschey, Jason↗

Thermal Management System for an Electric Machine with Additively Manufactured Hollow Conductors with Integrated Heat Pipes: Preprint

This paper discusses steps taken to size a thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal FEA is used to determine optimum heat transfer coefficient of convective boundaries. Geometric details of fin-based surface area enhancement required to reach target combined overall heat transfer coefficient (U) and surface area (A) performance (UA) in W/K, is worked out for relevant boundaries and the resulting UA is verified in 3D thermal FEA. Thermal management system's UA (by extension specific power) sensitivity to coolant temperature is explored and temperature distribution plots of optimized machine components are presented and discussed.

additive manufacturing↗

Exploring Plasma Heating in the Current Sheet Region in a Three-dimensional Coronal Mass Ejection Simulation

We simulate a coronal mass ejection using a three-dimensional magnetohydrodynamic code that includes coronal heating, thermal conduction, and radiative cooling in the energy equation. The magnetic flux distribution at 1 Rs is produced by a localized subsurface dipole superimposed on a global dipole field, mimicking the presence of an active region within the global corona. Transverse electric fields are applied near the polarity inversion line to introduce a transverse magnetic field, followed by the imposition of a converging flow to form and destabilize a flux rope, producing an eruption. We examine the quantities responsible for plasma heating and cooling during the eruption, including thermal conduction, radiation, adiabatic effects, coronal heating, and ohmic heating. We find that ohmic heating is an important contributor to hot temperatures in the current sheet region early in the eruption, but in the late phase, adiabatic compression plays an important role in heating the plasma there. Thermal conduction also plays an important role in the transport of thermal energy away from the current sheet region throughout the reconnection process, producing a “thermal halo” and widening the region of high temperatures. We simulate emission from solar telescopes for this eruption and find that there is evidence for emission from heated plasma above the flare loops late in the eruption, when the adiabatic heating is the dominant heating term. These results provide an explanation for hot supra-arcade plasma sheets that are often observed in X-rays and extreme ultraviolet wavelengths during the decay phase of large flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical Study of Energy Dissipation in Magnetic Structures During Turbulent Reconnection in the Earth's Magnetotail

Magnetic reconnection is a ubiquitous plasma phenomenon that plays a critical role in particle heating and energization. During reconnection, the topology of magnetic field rearranges, depositing energy into the surrounding plasma through bulk flow, thermal heating, or non-thermal particle acceleration. While the pathways of this transformation from magnetic energy into kinetic have been studied extensively in recent years through theoretical or case-by-case observations, comprehensive statistical studies remain limited. In this paper, we present a statistical investigation using data from the Magnetospheric Multiscale (MMS) mission, and detail the particle energization mechanisms in magnetic structures found near reconnecting regions in turbulent Earth's magnetotail. We find that electrons with motion perpendicular to the magnetic field dominate $\vec{j}$ ⋅ $\vec{E}$ dissipation. In contrast to the conventional picture of unidirectional energy transfer to particles by laminar two-dimensional (2D) reconnection, we find that energy exchange within magnetic structures during turbulent reconnection tends to be bidirectional with only a small positive bias from electromagnetic fields to particles. Specific electron energization mechanisms are quantified, including those due to parallel electric field, Fermi energization from curvature drift, betatron heating from magnetic field inhomogeneity, and polarization drift.

Wang, Rachel [Princeton University, NJ (United Sta↗

Determination of single crystal thermal expansion in Uranium-6wt%Niobium shape memory alloy using in-situ diffraction and modeling of textured polycrystalline samples

In-situ neutron diffraction and ex-situ dilatometry experiments were performed on a chemically banded, quenched uranium-6wt% niobium shape memory alloy to study the impact of deformation-(detwinning-) induced texture on the evolution of thermally induced strains (and associated stresses). Thermal heating and cooling cycles between 5K and 473K were performed in-situ with neutron diffraction, and the lattice strain evolution is reported for the observed monoclinic α" phase. Comparisons between the measured diffraction strains and macroscopic dilatometry experiments reveal relationships between micro- and macro-level thermal expansion. Softening of the texture during heating suggests that twin boundary motion can accommodate the large internal thermal strains which are approximately 2% greater than that typically observed during the 175K heating interval used to age more randomly oriented polycrystalline material. Assuming weak constraint of neighboring grains in randomly textured polycrystals, the single crystal thermal expansion tensor is extracted from measurements of lattice strains over the range 5K to 473K. Predictions of polycrystalline thermal expansion, based upon this single crystal thermal expansion tensor, are shown to compare favorably with bulk thermal expansion observations of the as quenched microstructure. However, such a lower-bound estimate is insufficient to explain all aspects of the behavior of the textured material, where the matrix is not isotropic. In conclusion, it is hypothesized that relaxation processes which occur within the quenched microstructure during heating are responsible for the distinct thermal expansion behavior observed during the initial heating cycle compared to cooling and subsequent cycling.

36 MATERIALS SCIENCE↗

Microwave Regeneration and Thermal and Oxidative Stability of Imidazolium Cyanopyrrolide Ionic Liquid for Direct Air Capture of Carbon Dioxide

Abstract Understanding the oxidative and thermal degradation of CO 2 sorbents is essential for assessing long‐term sorbent stability in direct air capture (DAC). The potential degradation pathway of imidazolium cyanopyrrolide, an ionic liquid (IL) functionalized for superior CO 2 capacity and selectivity, is evaluated under accelerated degradation conditions to elucidate the secondary reactions that can occur during repetitive absorption‐desorption thermal‐swing cycles. The combined analysis from various spectroscopic, chromatographic, and thermal gravimetric measurements indicated that radical and S N 2 mechanisms in degradation are encouraged by the nucleophilicity of the anion. Thickening of the liquid and gas evolution are accompanied by 50 % reduction in CO 2 capacity after a 7‐day exposure to O 2 under 80 °C. To prevent long exposure to conventional thermal heating, microwave (MW) regeneration of the CO 2 ‐reactive IL is used, where dielectric heating at 80 and 100 °C rapidly desorbs CO 2 and regenerates the IL without any measurable degradation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗