Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermocouple”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Frequency response in short thermocouple wires

Theoretical expressions are derived for the steady state frequency response of a thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for a nonuniform wire with unequal material properties and wire diameters across the junction. The amplitude ratio at low frequency omega approaches 0 agrees with the results of Scadron and Warshawsky (1952) for a steady state temperature distribution. Moreover, the frequency response for a nonuniform wire in the limit of infinite length l approaches infinity is shown to reduce to a simple expression that is analogous to the classic first order solution for a thermocouple wire with uniform properties. Theoretical expressions are also derived for the steady state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire and a two material wire with unequal material properties across the junction. For the case of a one material supported wire, an exact solution is derived which compares favorably with an approximate expression that only matches temperatures at the support junction. Moreover, for the case of a two material supported wire, an analytical expression is derived that closely correlates numerical results. Experimental measurements are made for the steady state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10 pct. with the theoretical predictions of Forney and Fralick (1991). This is accomplished by choosing a natural frequency omega sub n for the wire data to correlate the first order response at large gas temperature frequencies. It is found that a large bead size, however, will increase the amplitude ratio at low frequencies but decrease the natural frequency of the wire. The phase angle data are also distorted for imperfect junctions.

Forney, L. J.↗

A computer-controlled apparatus for Seebeck inhomogeneity testing of sheathed thermocouples

Mineral-insulated metal-sheathed (MIMS) thermocouple assemblies are used throughout industry and research facilities as a method of temperature measurement where requirements for either harsh environmental conditions exist, or where rigidity of the measurement probe is required. Seebeck inhomogeneity is the abnormal variation of the Seebeck coefficient from point to point in a material. It is not disclosed in conventional calibration. A standardized method of measuring thermoelectric inhomogeneity along the thermocouple probe length is not available. Therefore, calibration for sheathed probes normally does not include testing of probe inhomogeneity. The measurement accuracy would be severely impacted if significant inhomogeneity and a temperature gradient were present in the same region of the probe. A computer-controlled system for determining inhomogeneities was designed, fabricated, and tested. This system provides an accurate method for the identification of the location of inhomogeneity along the length of a sheathed thermocouple and for the quantification of the inhomogeneity. This paper will discuss the apparatus and procedure used to perform these tests and will present data showing tests performed on sheathed thermocouple probes.

Burkett, Cecil G., Jr.↗

High-Temperature, Oxidation-Resistant Thermocouples

Aluminum substituted for rhodium, which is scarce and expensive. Electromotive force increases with aluminum content in Pt/Al leg of Pt(Pt/Al) thermocouple. Wires baked longer in aluminizing bed produce larger voltages. Thermocouples containing platinum/aluminum legs used instead of thermocouples of type R in furnaces, heat engines, and chemical reactors. Expecially suited to high-velocity oxidizing environments. Constructed as thin-film sensors on turbine blades and vanes, where pre-oxidation provides insulating film needed between thermocouple legs. Because aluminum content slowly depleted by oxidation, long-term use recommended only where maximum temperature is 1,200 degrees C or less.

Smialek, James L.↗

Three-Wire Thermocouple: Frequency Response in Constant Flow

Theory and experimental measurements are compared with a novel three-wire thermocouple. Signals from three wires of unequal diameters are recorded from the thermocouple suspended in constant flow with a periodic temperature fluctuation. It is demonstrated that the reconstructed signal from the three-wire thermocouple requires no compensation for omega less than or equal to 5(omega(sub 1)), where omega(sub 1) is the natural frequency of the smaller wire. The latter result represents a significant improvement compared to previous work with two-wire thermocouples. A correction factor has also been derived to account for wires of arbitrary diameter.

Forney, L. J.↗

Three-wire Thermocouple: Frequency Response in Constant Flow

Theory and experimental measurements are compared with a novel three-wire thermocouple. Signals from three wires of unequal diameters arc recorded from the thermocouple suspended in constant flow with a periodic temperature fluctuation. It is demonstrated that the reconstructed signal from the three-wire thermocouple requires no compensation for omega less than or equal to 5(sub omega1), where omega, is the natural frequency of the smaller wire. The latter result represents a significant improvement compared to previous work with two-wire thermocouples. A correction factor has also been derived to account for wires of arbitrary diameter.

Forney, L. J.↗

Advanced Microscopic Integrated Thermocouple Arrays

The purpose of this research is to develop and refine a technique for making microscopic thermocouple arrays for use in measuring the temperature gradient across a solid-liquid interface during the solidification process. Current thermocouple technology does not allow for real-time measurements across the interface due to the prohibitive size of available thermocouples. Microscopic thermocouple arrays will offer a much greater accuracy and resolution of temperature measurements across the solid-liquid interface which will lead to a better characterization of the solidification process and interface reaction which affect the properties of the resulting material.

Pettigrew, Penny J.↗

Thin film ceramic thermocouples

A thin film ceramic thermocouple (10) having two ceramic thermocouple (12, 14) that are in contact with each other in at least on point to form a junction, and wherein each element was prepared in a different oxygen/nitrogen/argon plasma. Since each element is prepared under different plasma conditions, they have different electrical conductivity and different charge carrier concentration. The thin film thermocouple (10) can be transparent. A versatile ceramic sensor system having an RTD heat flux sensor can be combined with a thermocouple and a strain sensor to yield a multifunctional ceramic sensor array. The transparent ceramic temperature sensor that could ultimately be used for calibration of optical sensors.

Gregory, Otto↗

Thermocouple assembly

Disclosed is a thermocouple assembly having a resilient mount; a buffer having a first side and a second side, with the buffer first side connecting with the resilient mount; an insulator having a first side and a second side, with the insulator first side connecting with the buffer second side; and a thermocouple having a first side and a second side, the thermocouple first side connecting with the insulator second side, and the thermocouple second side being configured to be in thermal contact with an object to be measured.

Schwarting, Nelson↗

In situ embedment of type K sheathed thermocouples with directed energy deposition

Advanced nuclear reactor systems require new technologies for heat transfer and system monitoring. Additive manufacturing (AM) offers the design flexibility to allow in-situ sensor embedment through smart manufacturing for real-time monitoring, and performance of these systems. Here, this study focuses on experiments investigating the feasibility of in-situ sensor embedment using directed energy deposition (DED). Type K thermocouples are embedded into 316L stainless steel (SS) samples using two different configurations (e.g., exposed and embedded tips) and two designs (e.g., flush to substrate) within an AM base. Embedded sensor samples are analyzed via in-situ measurements and high-temperature performance validation tests at 350ºC and 900ºC. Temperature performance results at both temperature tests show good agreement with manufacturer specifications proving that these sensors could still capture accurate temperature readings after in-situ embedment during DED processing. An additional optimization experiment was conducted on the exposed tip configuration using a surrogate thermocouple to improve tolerances and the embedment process. Results improved tolerances, lower porosity, smaller gaps between the sensor and base, and better junction contact for the sensor. Although further optimization of this embedment strategy is necessary to improve the structural stability and tolerances within the component, this research strategy provides a proof-of-feasibility for DED embedment with commercial sheathed thermocouples. This research provides early impact on embedment of sensor for multiple materials and complex geometric components..

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Design and Implementation of Surface Eroding Thermocouples for Stage-One Modular Divertor Integration at the DIII-D Tokamak

The DIII-D has upgraded its upper divertor to a modular system using copper alloy pedestals to alter the divertor geometry without changing the vessel structure. Six new graphite tiles were designed for the shape and volume rise (SVR) divertor. Here, these new SVR tiles facilitated the formation of a poloidal array of 27 surface eroding thermocouples (SETCs) in the upper divertor region. At one location, a specialized recessed SETC, paired with a standard flush SETC, was installed in one of the ceiling tiles to provide comprehensive heat flux measurements, distinguishing between charged and noncharged particle contributions. Upgrades were made to the SETC system in the small-angle slot (SAS) divertor to improve overall performance. These upgrades included optimizing the feedthrough system to double the thermocouple cable capacity and reallocating cables from the SAS area to the SVR divertor. A compact isolation amplifier system with a fixed gain of 41 was employed to improve the signal level and minimize interference. Additionally, two analog-to-analog fiber systems were implemented for transmitting thermocouple signals over a single fiber, significantly reducing both noise levels and costs. The newly installed SETCs in the SVR divertor successfully completed initial commissioning testing. The SETCs captured the in-out asymmetry in the power distribution between the inner and outer strike points and demonstrated the dependency of the heat flux profile on the outer strike point location. During divertor detachment, heat flux mitigation was noted at the outer strike point location, while significant heat flux contributions from neutral particles were measured in the SVR divertor.

Divertor↗

High temperature thermocouple operates in reduction atmosphere

Thermocouple continuously measures a flowing gas up to 4500 degrees F in a hazardous environment. The thermocouple combines rhenium and tungsten in the probe, housing, and swaged extension lead. The wires extend continuously from the cold junction to the probe tip to eliminate errors from secondary thermocouple effects.

Hoff, R. G.↗

Accurate depth control provided for thermocouple junction locations

Flight reentry experiments define the total heating on a large blunt-nosed body by means of imbedded thermocouples. The thermocouples, installed in a beryllium layered forebody, were designed to provide minimum feasible disturbance of local heat flow with accurate depth control of the thermocouple junction locations.

Richardson, N. R.↗

Tungsten-rhenium alloy thermocouples effective for high-temperature measurement

Tungsten-rhenium alloy thermocouples, specifically, insulated, sheathed W/W plus 26Re and W plus 5 Re/W plus 26 Re thermocouples, are effective for temperature measurement in excess of 2920 degrees C. These thermocouples have a high thermoelectric output and excellent relationship to temperatures up to 2760 degrees C.

Brooks, E. J.↗

Inexpensive high-temperature furnace for thermocouple calibration

New furnace calibrates unknown thermocouple by comparing its electrical output to a reference thermocouple /previously calibrated by optical pyrometry/, as both are heated simultaneously. Thermocouples may be radioactive, thus heat source must be accessible by remote manipulation and inspection measurements. Advantages of furnace operation are cited.

Gracey, C. M.↗

Study of performance characteristics of noble metal thermocouple materials to 2000 C

Three performance characteristics of noble metal thermocouples in various environments are discussed. Catalytic effects cause significant errors when noble metal thermocouple materials are exposed to air containing unburned gases in temperature ranges from 25 C to 1500 C. The thermoelectric stability of the iridium 40 rhodium to iridium thermocouple system at 2000 C in an oxidizing medium is described. The effects of large and small temperature gradients on the accuracy and stability of temperature measurements are analyzed.

Freeze, P. D.↗

Studies of the performance of W-Re type thermocouples.

The effect of exposure of bare-wire and BeO-insulated commercial W-Re thermocouple materials to high temperatures in gaseous environments was investigated. The temperature range of interest was primarily 2000 to 2400 K, and the investigations were confined to thermocouple wires of 0.25 mm diameter. Thermoelements were examined for metallurgical structural changes and chemical changes by conventional methods. In the temperature range of interest, grain growth was inhibited in the chemically doped W-3% Re alloy, and excellent room-temperature ductility was retained subsequent to the exposure. The compatibility of high purity (in excess of 99.8%), sintered BeO insulators with the thermoelements differed, depending upon whether the BeO-insulated thermoelement assemblies were self-heated electrically or heated in a furnace; in tests in argon environments, highly reliable performance occurred when the assemblies were heated in a furnace. BeO-insulated W-3% Re vs W-25% Re thermocouples, constructed with degassed and aged materials, exhibited drifts equivalent to about 3 mK/hr during 1000 hours of exposure at 2073 K in argon while in the presence of tantalum.

Burns, G. W.↗

Theory and performance of plated thermocouples.

A theory has been developed to describe the performance of thermocouples which have been formed by electroplating portions of one thermoelectric material with another. The electroplated leg of the thermocouple was modeled as a collection of infinitesimally small homogeneous thermocouples connected in series. Experiments were performed using several combinations of Constantan wire sizes and copper plating thicknesses. A transient method was used to develop the thermoelectric calibrations, and the theory was found to be in quite good agreement with the experiments. In addition, data gathered in a Soviet experiment were also found to be in close agreement with the theory.

Pesko, R. N.↗