Search NASASearch

SEARCH · Search NASA

Results for “time at temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

881 records · Page 4

Biobased Polybenzoxazine Derived from Furfurylamine and Piceol with Low Cure Temperature and Advanced Properties for Composite Matrices

A novel benzoxazine made from furfurylamine, paraformaldehyde, and piceol, Bz-FA-HA, is assessed for applications in fiber reinforced (FR) composites. Piceol is a biobased phenolic compound derived from the roots of Norwegian spruce trees and contains a methyl ketone group at the para position. Bz-FA-HA is a liquid at room temperature, has a viscosity of < 1 Pa.s at temperatures above 90 °C, and a Tonset of cure at 132 °C. The carbonyl is found to react with the furan ring, yielding a crosslinking reaction, when cured above 180 °C as indicated by differential scanning calorimetry and thermogravimetric analysis coupled with Fourier transform infrared spectroscopy. Poly(Bz-FA-HA) has a Tg > 350 °C, attributed to the crosslinking reaction. Furthermore, the storage modulus is > 3 GPa, regardless of cure temperature. Poly(Bz-FA-HA) has a char yield at 800 °C of 65.0 % (62.3 % at 1000 °C), and a Tonset of decomposition of 357 °C in nitrogen. The resulting carbon formed during pyrolysis shrinks during the carbonization reaction and scanning electron microscopy imaging shows a cross-section with micro cracks. The high processability, advanced mechanical properties, and exceptional char yield make it a promising candidate as the matrix for FR composites.

Benzoxazine

Predicting Operational Performance of xEMU Boot at Lunar South Pole Temperatures using Thermal Desktop ®

The spacesuit boots that will be used on Artemis lunar south pole surface missions will be exposed to extremely cold temperatures (down to ~50 K). To assess the performance of the government’s Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these permanently shadowed regions, testing was performed at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU CITADEL TVAC test. Expected thermal conductances within the boot and between the boot and environment were calculated from test data, which was then used as an initial guess for conductances within a Thermal Desktop (TD) model. Correlation of the TD model using the internal SOLVER feature was performed across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. Operational performance at the lunar south pole was then predicted using results from the correlated model. While the predictions provide evidence for acceptable performance of the boots at the 100K environment test point, there is still substantial uncertainty in performance, especially at the 48K test point. This uncertainty is due in part to testing limitations such as contacting the foot to a hard metal plate rather than granular regolith, and model limitations such as the lack of a realistic foot model. These limitations and their impacts are addressed in detail in this paper. The results of this test series and model correlation underscore the importance of additional improved testing and modeling for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

Spacesuit

Observational Requirements for the Regional Scale

Observational requirements are provided for the 'regional scale' (10 2 to 10 3 km space scale; 3 to 24 h time scale). Given this range, the regional scale represents a spatial and temporal domain in which important scale-interactive processes occur that act to concentrate large vertical wind shears, significant horizontal thermal gradients, and vertical motion patterns into narrow regions. A short review of the mass and momentum adjustments associated with jet streak-induced circulations is discussed. Evidence for the need to specify the wind field in the upper troposphere to accurately simulate forcing for the transverse circulations is also presented. The importance of specifying temperature tendency to resolve the lower tropospheric portion of the transverse circulations is highlighted. The observational requirements are then discussed, along with possible approaches for meeting the requirements on the regional scale.

Louis W Uccellini

Battery simulation program

Computer program calculates spacecraft battery energy at specific times dictated by input sequence of recharge, discharge, and no activity phases. Recharge phases are assumed during times not specified, unless batteries are fully charged. Warnings are printed when energy falls below specified level. Program assumes two identical batteries.

Abreu, A.

Plume Impingement Software Module for Real-Time Proximity Operations

Successfully executing proximity operations in space, such as docking or in-orbit servicing, requires sophisticated spacecraft design that accounts for induced environments. As a chaser vehicle’s attitude control thrusters fire, they create rarefied plumes that can impact the target vehicle, with the potential to overload components, exceed thermal limits, and spin the target vehicle out of control. High-fidelity simulations of the thruster plume impingement environment require the direct simulation Monte Carlo (DSMC) method, but DSMC is too computationally expensive to simulate proximity operations that involve thousands of thruster firings. For this analysis to be tractable, engineering models of the plume flowfield and impingement events are used to simulate these trajectories [1]. Currently, on-orbit plume impingement environments are modeled through an inefficient open-loop analysis cycle where the vehicle’s flight controller and plume impingement teams iterate on the trajectories until they pass the target vehicle’s plume requirements. As complex on-orbit missions evolve and become more frequent, lengthy design cycles will become operational bottlenecks. To address this gap, this work develops an advanced plume impingement module capable of operating at real-time scale that can be integrated with existing mission planning tools and onboard flight systems. The plume module leverages state-of-the-art plume simulation techniques [2] to deliver fast, physics-based impingement predictions in a software architecture that can be tailored to diverse proximity operations scenarios. A prototype of this plume impingement module is built to demonstrate the feasibility of real-time performance. This prototype completes plume impingement calculations in microseconds per target geometry mesh point. The software serves as a foundational capability for plume-aware trajectory design, operational risk assessment, and future autonomous decision-making systems.

Plume Impingement

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Properties and Potential of Two (Ni,Pt)Ti Alloys for Use as High-Temperature Actuator Materials

The microstructure, transformation temperatures, basic tensile properties, shape memory behavior, and work output for two (Ni,Ti)Pt high-temperature shape memory alloys have been characterized. One was a Ni 30 Pt 20 Ti 50 alloy (referred to as 20Pt) with transformation temperatures above 230 °C and the other was a Ni 20 Pt 30 Ti 50 alloy (30Pt) with transformation temperatures above 530 °C. Both materials displayed shape memory behavior and were capable of 100% (no-load) strain recovery for strain levels up to their fracture limit (3-4%) when deformed at room temperature. For the 20Pt alloy, the tensile strength, modulus, and ductility dramatically increased when the material was tested just above the austenite finish (A f ) temperature. For the 30Pt alloy, a similar change in yield behavior at temperatures above the A f was not observed. In this case the strength of the austenite phase was at best comparable and generally much weaker than the martensite phase. A ductility minimum was also observed just below the A s temperature in this alloy. As a result of these differences in tensile behavior, the two alloys performed completely different when thermally cycled under constant load. The 20Pt alloy behaved similar to conventional binary NiTi alloys with work output due to the martensite-to-austenite transformation initially increasing with applied stress. The maximum work output measured in the 20Pt alloy was nearly 9 J/cm 3 and was limited by the tensile ductility of the material. In contrast, the martensite-to-austenite transformation in the 30Pt alloy was not capable of performing work against any bias load. The reason for this behavior was traced back to its basic mechanical properties, where the yield strength of the austenite phase was similar to or lower than that of the martensite phase, depending on temperature. Hence, the recovery or transformation strain for the 30Pt alloy under load was essentially zero, resulting in zero work output.

High-Temperature Shape Memory Alloy

Low Temperature Environment Operations of Turboengines (Design and User's Problems)

The author summarizes and links together a number of papers that were presented at the Propulsion and Energetics (PEP) symposium on low temperature environment operation of turbojet engines that was held October 8 to 12, 1990. Topics covered include operational experience of ice ingestion in the turboprop engine in the 2,000 hp class, icing on helicopter turbo engines, icing test facilities, ice relevant cloud physical parameters, and low temperature and fuel problems.

R Jacques

High-Fidelity Modeling Approach for Coupling Thermal, Fluid, and Neutronic Analysis in an NTP Engine

Nuclear thermal propulsion (NTP), with its increased efficiency compared to traditional rocket engines, is a potentially enabling technology for space missions of higher complexity, such as delivering heavy machinery or crew to the moon or other planets. Thus, exploring modeling approaches that can effectively couple the thermal, fluid, and neutronic behaviors of NTP reactors is essential to mitigate cost and schedule challenges with hardware development. This paper details one such approach which utilizes Cardinal to unify reactor physics analysis performed using OpenMC, heat transfer analysis performed using the MOOSE framework, and thermal hydraulic analysis performed using the MOOSE Thermal Hydraulic Module. This approach is demonstrated with a proof of concept that focuses on a legacy reactor geometry from the historic NERVA program. This preliminary model found an overprediction in, when compared to the reference data, axial power peaking and the temperatures of both solids and fluids by roughly 20%. It is clear, however, that the model conserved a number of broad trends, and a few model refinements should reduce the observed error. This approach has definite merit and should enable the production of informative results for more modern NTP systems. This work is a first step in creating a transient reactor model that can be updated across a sequence of time steps based on continually fluctuating, time-dependent boundary conditions.

Nuclear Thermal Propulsion

Using Satellite Surface Temperature Data to Monitor Urban Heat Island

Exposure to heat is a growing concern nationwide. Temperatures can be elevated in cities compared to surrounding rural areas, referred to as an “urban heat island” (UHI) effect, which is intensified during heat waves. The lack of dense networks of air temperature measurements results in few studies on urban heat. Now, a vast amount of high spatial and temporal satellite data on land surface temperature is available. We identified satellite datasets with the longest surface temperature records but different spatial and temporal resolutions: Landsat (1985-current, biweekly at 60 m and 100 m spatial resolution) and the Moderate Resolution Imaging Spectroradiometer (MODIS) data from the Terra and Aqua satellites (2000-current, daily at 1 km spatial resolution). We investigated how satellites with different spatial and temporal resolutions detect UHI effects differently. We hypothesized that 1) a dataset’s spatial resolution impacts the precision of detected UHIs spatially, since high spatial resolution Landsat data better captures spatial variability in temperature, and 2) daily surface temperature data can detect temporal patterns of UHIs and heatwave frequencies. We analyzed Landsat and MODIS satellite data in the Washington, D.C. and Baltimore region. We found that Landsat describes higher spatial variability of the UHI effect than MODIS data. However, MODIS data shows more consistent seasonal surface temperature patterns than Landsat when compared to in situ air temperature measurements. MODIS data was also able to consistently measure the frequency of heat waves. This study demonstrates the value of NASA satellite data for urban heat and climate change studies.

landsat

Properties of a Ni19.5Pd30Ti50.5 High-Temperature Shape Memory Alloy in Tension and Compression

Potential applications involving high-temperature shape memory alloys have been growing in recent years. Even in those cases where promising new alloys have been identified, the knowledge base for such materials contains gaps crucial to their maturation and implementation in actuator and other applications. We begin to address this issue by characterizing the mechanical behavior of a Ni 19.5 Pd 30 Ti 50.5 high-temperature shape memory alloy in both uniaxial tension and compression at various temperatures. Differences in the isothermal uniaxial deformation behavior were most notable at test temperatures below the martensite finish temperature. The elastic modulus of the material was very dependent on strain level; therefore, dynamic Young’s Modulus was determined as a function of temperature by an impulse excitation technique. More importantly, the performance of a thermally activated actuator material is dependent on the work output of the alloy. Consequently, the strain-temperature response of the Ni 19.5 Pd 30 Ti 50.5 alloy under various loads was determined in both tension and compression and the specific work output calculated and compared in both loading conditions. It was found that the transformation strain and thus, the specific work output were similar regardless of the loading condition. Also, in both tension and compression, the strain-temperature loops determined under constant load conditions did not close due to the fact that the transformation strain during cooling was always larger than the transformation strain during heating. This was apparently the result of permanent plastic deformation of the martensite phase with each cycle. Consequently, before this alloy can be used under cyclic actuation conditions, modification of the microstructure or composition would be required to increase the resistance of the alloy to plastic deformation by slip.

High-Temperature Shape Memory Alloy

Lubricating Properties of Ceramic-Bonded Calcium Fluoride Coatings on Nickel-Base Alloys From 75° to 1900° F

The endurance life and the friction coefficient of ceramic-bonded calcium fluoride (CaF2) coatings on nickel-base alloys were determined at temperatures from 75° to 1900° F. The specimen configuration consisted of a hemispherical rider (3/16-in. rad.) sliding against the flat surface of a rotating disk. Increasing the ambient temperature (up to 1500° F) or the sliding velocity generally reduced the friction coefficient and improved coating life. Base-metal selection was critical above 1500° F. For instance, cast Inconel sliding against coated Inconel X was lubricated effectively to 1500° F, but at 1600° F severe blistering of the coatings occurred. However, good lubrication and adherence were obtained for René 41 sliding against coated René 41 at temperatures up to 1900° F; no blisters developed, coating wear life was fairly good, and the rider wear rate was significantly lower than for the unlubricated metals . Friction coefficients were 0.12 at 1500° F, 0.15 at 1700° F, and 0.17 at 1800° and 1900° F. Because of its ready availability, Inconel X appears to be the preferred substrate alloy for applications in which the temperature does not exceed 1500° F. René 41 would have to be used in applications involving higher temperatures. Improved coating life was derived by either preoxidizing the substrate metals prior to the coating application or by applying a very thin (<0.0002 in.) burnished and sintered overlay to the surface of the coating. Preoxidation did not affect the friction coefficient. The overlay generally resulted i n a higher friction coefficient than that obtained without the overlay. The combination of both modifications resulted in longer coating life and in friction coefficients intermediate between those obtained with either modification alone.

Nickel alloy

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains - Task 2: Power Quality Filtering Using Nanocrystalline Soft Magnetic Inductor

The NASA RTAPS program on AC and DC Fault Management for Megawatt Electrified Power Train is a multi-year joint project with Pratt & Whitney (P&W), Collins Aerospace (CA), and RTX Technology Research Center (RTRC). This research program focuses on the high-voltage distribution issues that present a significant technological obstacle in the adoption of Electrified Aviation Propulsion (EAP) systems. One challenge to the adoption of high-voltage distribution systems with power electronic converters is the need for filter elements to limit the generation and propagation of noise, protect the cable systems from premature aging and prevent against excessive heating within subcomponents due to high-frequency induced currents. While increased distribution voltages aide in reducing the cable mass for a fixed power system, the associated mass with the filtering elements for power electronic converter can grow with increasing distribution voltages – thereby mitigating any benefit associated with increasing the distribution system voltage. To enable high-voltage distribution systems with high system specific power densities, new magnetic materials must be developed. Therefore, the second task of the NASA RTAPS program is associated with the design and application of advanced soft magnetic components for Megawatt class electric propulsion systems, specifically the motor drive system. This report covers the collaborative work between NASA Glenn Research Center (GRC), RTRC, P&W and CA in the development of three types of magnetic components over the span of the three-year program. These critical magnetic components are the DC side EMI filter, which limits the propagation of harmful electromagnetic noise to the rise of the distribution system, and the AC side damping with the dv/dt filter, which limits the fast rise time of the power electronic converter output voltage to limit the degradation on the cable/motor insulation systems. Each of these components are investigated from component level design and are optimized at the system level with a combined modelling and testing effort. In the final experimental evaluation of the NASA developed soft magnetic material with a dv/dt filter, a commercial-off-the-shelf (COTS) magnetic core and the GRC magnetic core are optimized and loaded at 320Arms to evaluate their difference in performance. After a run time of 30 minutes in a MW-class motor driver at RTRC, the NASA GRC cores were found to not only offer a lower temperature rise of nearly 25°𝐶, but also a reduction in measured core loss of 25% (12.75W to 9.5W).

Elecrified Aircraft Propulsion

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe