Lunar Flight Study Series: Volume 7. Earth-Moon Transit Studies Based on Ephemeris Data and Using Best Available Computer Program: Principles for Reducing Earth-Moon Trajectory Analysis to Fundamentals - 2

This report presents an empirical investigation of earth-to-moon trajectories. The primary objective is to uncover relationships that result in the reduction of mission analysis or trajectory analysis problems to fundamentals. It is considered imperative that the results be accurate to the extent that any relationships that are uncovered are not brought about by simplifying or unrealistic assumptions. Consequently, the model used is as accurate as is presently available for use and the computations are performed under strict error controls. Procedures are reasonable from the engineering viewpoint. Some very helpful principles are uncovered. These may be briefly stated as follows: 1) Trajectories of constant flight time to the moon (in the 66 hour to 90 hour range), and arriving within a few minutes of the same time pass over a common point on the moon regardless of the arrival altitude and inclination, This common point of passage for such a family of trajectories is arbitrarily referred to as a VERTEX point; 2) These VERTEX points lie within a bounded region on the lunar surface as arrival time varies throughout the years, for a given flight time or flight time spread; 3) Increasing flight time results primarily in a longitude shift of the VERTEX point for a given arrival time; 4) Launch azimuth should be treated as a strong parameter regarding its influence on the vertex. Launch azimuth variations up to +/- 20 degrees about 90 degrees can shift the vertex as much as 3 degrees in latitude even when one is free to pick launch time, coast time, and S-IVB burn time appropriately with launch azimuth; and 5) The locus of periselenum, as arrival inclination takes on all possible values, is nearly circular about the vertex point for a given arrival altitude. A publication is now in preparation that applies these principles to much advantage in the solution of various trajectory analysis problems.

LUNAR FLIGHT↗

A Segmented Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOFMS) is described in which the single flight tube of a conventional TOFMS has been replaced by several cylindrical electrostatic lenses in tandem. By a judicious choice of voltages on these lenses, an improved TOFMS has been realized which has a superior mass and energy resolution, shorter flight lengths, excellent signal-to-noise ratio, and less stringent requirements on the bias voltages.

time-of-flight↗

A Low-cost, Lightweight, and Miniaturized Time-of-flight Mass Spectrometer (TOFMS)

Time-of-flight mass spectrometers (TOFMS) are commonly used for mass analysis and for the measurement of energy distributions of charged particles. For achieving high mass and energy resolution these instruments generally comprise long flight tubes, often as long as a few meters. This necessitates high voltages and a very clean environment. These requirements make them bulky and heavy. We have developed an instrument and calibration techniques that are based on the design principles of TOFMS. However, instead of one long flight tube it consists of a series of cylindrical electrostatic lenses that confine ions under study along the axis of the flight tube.

Srivastava, S. K.↗

Implementation of a new type of time-of-flight laser anemometer

A new time-of-flight (TOF) laser anemometer system utilizing a spatial lead-lag filter for bipolar pulse generation has been constructed and tested. This new TOF has been modified to enable measurements in turbulent flows near walls. Good results have been obtained as close as 100 microns from a surface, with a 140-mm focal length final lens. Lading's theory for the behavior of the measurement variance has been confirmed for this configuration.

Wernet, M. P.↗

High precision electric gate for time-of-flight ion mass spectrometers

A time-of-flight mass spectrometer having a chamber with electrodes to generate an electric field in the chamber and electric gating for allowing ions with a predetermined mass and velocity into the electric field. The design uses a row of very thin parallel aligned wires that are pulsed in sequence so the ion can pass through the gap of two parallel plates, which are biased to prevent passage of the ion. This design by itself can provide a high mass resolution capability and a very precise start pulse for an ion mass spectrometer. Furthermore, the ion will only pass through the chamber if it is within a wire diameter of the first wire when it is pulsed and has the right speed so it is near all other wires when they are pulsed.

Sittler, Edward C.↗

Time of flight system on a chip

A CMOS time-of-flight TOF system-on-a-chip SoC for precise time interval measurement with low power consumption and high counting rate has been developed. The analog and digital TOF chip may include two Constant Fraction Discriminators CFDs and a Time-to-Digital Converter TDC. The CFDs can interface to start and stop anodes through two preamplifiers and perform signal processing for time walk compensation (110). The TDC digitizes the time difference with reference to an off-chip precise external clock (114). One TOF output is an 11-bit digital word and a valid event trigger output indicating a valid event on the 11-bit output bus (116).

Paschalidis, Nicholas P.↗

Time-of-flight technique for particle identification at energies from 2 to 400 keV/nucleon

The time of flight technique for particle identification was extended to 2 keV/nucleon and the size of the start-time detector was reduced considerably by the use of carbon foils of few micrograms/cm square in thickness combined with microchannel plates for detecting secondary electrons. Time of flight telescopes incorporating this start-time device were used to measure the stopping power of a number of low energy heavy ions in thin carbon foils and the charge states of these ions emerging from such foils. Applications for the detection and identification of low energy interplanetary and magnetospheric particles are suggested.

Gloeckler, G.↗

Rocket-borne time-of-flight mass spectrometry

Theoretical and numerical analyses are made of planar, cylindrical and spherical-electrode two-field time-of-flight mass spectrometers in order to optimize their operating conditions. A method is introduced which can improve the resolving power of these instruments by a factor of 7.5. Potential barrier gating in time-of-flight mass spectrometers is also analyzed. Experimental studies of a miniature cylindrical-electrode and a hemispherical-electrode time-of-flight mass spectrometer are presented. Their sensitivity and ability to operate at D-region pressures with an open source make them ideal instruments for D-region ion composition measurements. A sounding rocket experiment package carrying a cylindrical electrode time-of-flight mass spectrometer was launched. The data indicate that essentially 100% of the positive electric charge on positive ions is carried by ions with mass-to-charge ratios greater than 500 below an altitude of 92 km. These heavy charge carriers were present at altitudes up to about 100 km.

Reiter, R. F.↗

Detector response in time-of-flight mass spectrometry at high pulse repetition frequencies

Dead time effects in chevron configured dual microchannel plates (MCPs) are investigated. Response times are determined experimentally for one chevron-configured dual MCP-type detector and two discrete dynode-type electron multipliers with 16 and 23 resistively divided stages. All of these detectors are found to be suitable for time-of-flight mass spectrometry (TOF MS), yielding 3-6-ns (FWHM) response times triggered on a single ion pulse. It is concluded that, unless there are viable solutions to overcome dead time disadvantages for continuous dynode detectors, suitable discrete dynode detectors for TOF MS appear to have a significant advantage for high repetition rate operation.

Gulcicek, Erol E.↗

Space and velocity focusing in time-of-flight mass spectrometers

A focusing equation is developed describing the relationship between space and velocity focusing for all one-dimensional time-of-flight mass spectrometers with constant electric fields. As a result of this equation, first-order double time focusing in one dimension is impossible. The possibility of large improvements in the resolving power of the time-of-flight mass spectrometers is discussed on this basis. The focusing equation also leads to an expression for the minimum time resolution obtainable. This second equation is applied to the conventional Wiley and McLaren (1955) two-field time-of-flight mass spectrometer with and without time-lag focusing, and to the mirror instrument of Karataev et al. (1972).

Stein, R.↗

Time-of-flight measurements of metastable state lifetimes.

A time-of-flight method for measurement of the lifetime of metastable molecules is described. The method is applicable to a molecular beam that has molecules in several different metastable excited states. As compared to methods used previously, the method has the advantages that it does not require selective excitation or quenching of the different states; moreover, it does not require a determination of the relative populations or velocity distributions of molecules in the excited states.

Kaslow, D. E.↗

Projecting Future Scheduled Airline Demand, Schedules and NGATS Benefits Using TSAM

The Transportation Systems Analysis Model (TSAM) developed by Virginia Tech s Air Transportation Systems Lab and NASA Langley can provide detailed analysis of the effects on the demand for air travel of a full range of NASA and FAA aviation projects. TSAM has been used to project the passenger demand for very light jet (VLJ) air taxi service, scheduled airline demand growth and future schedules, Next Generation Air Transportation System (NGATS) benefits, and future passenger revenues for the Airport and Airway Trust Fund. TSAM can project the resulting demand when new vehicles and/or technology is inserted into the long distance (100 or more miles one-way) transportation system, as well as, changes in demand as a result of fare yield increases or decreases, airport transit times, scheduled flight times, ticket taxes, reductions or increases in flight delays, and so on. TSAM models all long distance travel in the contiguous U.S. and determines the mode choice of the traveler based on detailed trip costs, travel time, schedule frequency, purpose of the trip (business or non-business), and household income level of the traveler. Demand is modeled at the county level, with an airport choice module providing up to three airports as part of the mode choice. Future enplanements at airports can be projected for different scenarios. A Fratar algorithm and a schedule generator are applied to generate future flight schedules. This paper presents the application of TSAM to modeling future scheduled air passenger demand and resulting airline schedules, the impact of NGATS goals and objectives on passenger demand, along with projections for passenger fee receipts for several scenarios for the FAA Airport and Airway Trust Fund.

Dollyhigh, Samuel↗

High mass resolution isochronous time-of-flight spectrograph for three-dimensional space plasma measurements

By combining a toroidal electrostatic analyzer with a novel cylindrically symmetric isochronous time-of-flight mass spectrometer, an instrument was developed that simultaneously determines the three-dimensional distribution function of ions and differentiates species. The ion mass is determined to high resolution (M/Delta-M greater than 50) from the time of flight within a harmonic field configuration defined by hyperboloid equipotential surfaces. A second conventional time-of-flight channel makes use of particles leaving the thin entrance foil as neutrals. An additional solid state detector in which the neutrals are stopped allows the total energy and thereby the ionic charge of the incident ions to be determined as well. Information from the neutral and the ion channels can be combined to determine the total mass of an incident molecular ion and the mass of one atomic fragment.

Moebius, E.↗

An improved time of flight gamma-ray telescope to monitor diffuse gamma-ray in the energy range 5 MeV - 50 MeV

A time of flight measuring device is the basic triggering system of most of medium and high energy gamma-ray telescopes. A simple gamma-ray telescope has been built in order to check in flight conditions the functioning of an advanced time of flight system. The technical ratings of the system are described. This telescope has been flown twice with stratospheric balloons, its axis being oriented at various Zenital directions. Flight results are presented for diffuse gamma-rays, atmospheric secondaries, and various causes of noise in the 5 MeV-50 MeV energy range.

Dacostafereiraneri, A.↗