Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomographic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies

Testing and qualification of advanced nuclear fuels involves an iterative process of prototyping, in-pile irradiation testing, and in-situ or ex-situ examination. Fuel restructuring and fission product migration during burnup are among the most important aspects of fuel evolution that affect several important performance characteristics such as heat removal, accident tolerance, and fission product retention. Pool-side non-destructive characterization techniques provide fuel developers with tools to understand fuel evolution at different points of burnup. A design for a compact, submersible, and multi-modal gamma-ray tomography system for imaging irradiated nuclear fuel is presented here. Detector selection, collimator geometry and fabrication, mechanical design, imaging protocol and acquisition speed are discussed. Modeling calculations show that sub-millimeter resolution can be achieved in both transmission computed tomography images as well as in emission computed tomography images in a matter of hours. Several design compromises and fabrication challenges are discussed which should be taken into consideration for future submersible gamma-ray tomography instruments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tomographic assessment of peening for metallurgical bonding in cold spray

It is widely asserted that peening densifies cold spray coatings and improves particle–particle and particle–substrate bonding, yet systematic studies analyzing the evolution of bonding due to peening particle strikes are scarce. We explore peening at the level of individual particle impacts, by creating two-particle Cu-on-Cu stacks using laser-induced particle impact testing. Exploring impact velocities that range from the onset of bonding at the “critical velocity”, V cr , to its peak near 1.4⋅V cr , we perform full 3D tomography of the particle stacks to characterize the bonding state at the particle-substrate interface. Direct labeling of non-bonded patches and the total particle-substrate interface permits quantification and comparison of bonding in single impacts with bonding after subsequent impacts to reveal the origins of the peening effect. The data reveal a surprising finding: although a second impact directly atop the first particle increases the area of the particle-substrate interface (~40% area increase), there is no improvement in metallurgical bonding. Analysis of these data suggest that not only area expansion (and associated oxide rarefication), but also stress-induced extrusion of metal at that interface needs to occur to achieve metal-on-metal contact to see an enhancement in bonding. Furthermore, our analysis suggests that the subsequent impacting particle needs to have ~70% more kinetic energy to produce additional bonding; this implies that particle and velocity distributions within a spray may be helpful, and that peening may rely on unaligned impacts.

Bonding↗

Dynamic compressed sensing for real-time tomographic reconstruction

Electron tomography has achieved higher resolution and quality at reduced doses with recent advances in compressed sensing. Compressed sensing (CS) exploits the inherent sparse signal structure to efficiently reconstruct three-dimensional (3D) volumes at the nanoscale from undersampled measurements. However, the process bottlenecks 3D reconstruction with computation times that run from hours to days. Here we demonstrate a framework for dynamic compressed sensing that produces a 3D specimen structure that updates in real-time as new specimen projections are collected. Researchers can begin interpreting 3D specimens as data is collected to facilitate high-throughput and interactive analysis. Using scanning transmission electron microscopy (STEM), we show that dynamic compressed sensing accelerates the convergence speed by ~3-fold while also reducing its error by 27% for a Au/SrTiO 3 nanoparticle specimen. Before a tomography experiment is completed, the 3D tomogram has interpretable structure within ~33% of completion and fine details are visible as early as ~66%. Upon completion of an experiment, a high-fidelity 3D visualization is produced without further delay. Additionally, we report reconstruction parameters that tune data fidelity can be manipulated throughout the computation without re-running the entire process.

47 OTHER INSTRUMENTATION↗

Alpha Shape Analysis (ASA) Framework for Post- Clustering Property Determination in Atom Probe Tomographic Data

While application of clustering algorithms to atom probe tomography data have enabled quantification of solute clusters in terms of number density, size, and subcomposition there exist other properties (e.g., volume, surface area, and composition) that are better determined by defining an interface between the cluster and the surrounding matrix. The limitation in composition results from an ion selection step where the expected matrix ion types are omitted from the cluster search algorithm to enhance the contrast between the matrix and cluster and to reduce the complexity of the search. Previously, composition determination within solute clusters has utilized a secondary envelopment and erosion step on top of conventional methods such as maximum separation. In this work, we present a novel stochastic method that combines the particle identification fidelity of a conventional clustering algorithm with the analytical flexibility of mesh-based approaches through the generation of alpha shapes for each identified cluster. Furthermore, the corresponding mesh accounts for concave components of the clusters and determines the volume and surface area of the clusters; additionally, the mesh boundary is utilized to update the total composition according to the internal ions.

42 ENGINEERING↗

Ion temperature measurements from tomographic reconstruction of Doppler spectra in the presence of multi-component flow in two dimensions

A new ion Doppler diagnostic has been constructed to measure ion temperature profiles in the presence of multi-component flow during magnetic reconnection experiments. The inversion technique and diagnostic setup are applicable to axisymmetric plasmas with two-component flow across the measurement cross section, which occurs during magnetic reconnection. The particular design discussed here is optimized for operation on the Magnetic Reconnection eXperiment (MRX) at Princeton Plasma Physics Laboratory. To prove the viability of this diagnostic for MRX and the future Facility for Laboratory Reconnection Experiments, measurements have been taken and ion temperature and perpendicular flow profiles have been obtained. The radial velocity on MRX does not contribute to the Doppler shift of the measured spectra but does contribute to the broadening of the spectra, while toroidal flow contributes to both. It is shown that neglecting the radial velocity for vR = 20 km/s leads to an error in the ion temperature inversion of 20%. Results from MRX discharges are shown, and the impact of radial velocity on ion temperature inversions is discussed.

Goodman, A. (ORCID:0000000336396572)↗

Machine learning for detection of 3D features using sparse x-ray tomographic reconstruction

In many inertial confinement fusion (ICF) experiments, the neutron yield and other parameters cannot be completely accounted for with one and two dimensional models. This discrepancy suggests that there are three dimensional effects that may be significant. Sources of these effects include defects in the shells and defects in shell interfaces, the fill tube of the capsule, and the joint feature in double shell targets. Due to their ability to penetrate materials, x rays are used to capture the internal structure of objects. Methods such as computational tomography use x-ray radiographs from hundreds of projections, in order to reconstruct a three dimensional model of the object. In experimental environments, such as the National Ignition Facility and Omega-60, the availability of these views is scarce, and in many cases only consists of a single line of sight. Mathematical reconstruction of a 3D object from sparse views is an ill-posed inverse problem. These types of problems are typically solved by utilizing prior information. Neural networks have been used for the task of 3D reconstruction as they are capable of encoding and leveraging this prior information. We utilize half a dozen, different convolutional neural networks to produce different 3D representations of ICF implosions from the experimental data. Deep supervision is utilized to train a neural network to produce high-resolution reconstructions. These representations are used to track 3D features of the capsules, such as the ablator, inner shell, and the joint between shell hemispheres. Machine learning, supplemented by different priors, is a promising method for 3D reconstructions in ICF and x-ray radiography, in general.

Wolfe, Bradley T. (ORCID:0000000268301614)↗

Tomographic galaxy clustering with the Subaru Hyper Suprime-Cam first year public data release

We analyze the clustering of galaxies in the first public data release of the HSC Subaru Strategic Program. Despite the relatively small footprints of the observed fields, the data are an excellent proxy for the deep photometric datasets that will be acquired by LSST, and are therefore an ideal test bed for the analysis methods being implemented by the LSST DESC. We select a magnitude limited sample with i<24.5 and analyze it in four redshift bins covering 0.15≲z≲1.5. We carry out a Fourier-space analysis of the two-point clustering of this sample, including all auto- and cross-correlations. We demonstrate the use of map-level deprojection methods to account for fluctuations in the galaxy number density caused by observational systematics. Through an HOD analysis, we place constraints on the characteristic halo masses of this sample, finding a good fit up to scales k max = 1Mpc –1 , including both auto- and cross-correlations. Our results show monotonically decreasing average halo masses, which can be interpreted in terms of the drop-out of red galaxies at high redshifts for a flux-limited sample. In terms of photometric redshift systematics, we show that additional care is needed in order to marginalize over uncertainties in the redshift distribution in galaxy clustering, and that these uncertainties can be constrained by including cross-correlations. We are able to make a ~3σ detection of lensing magnification in the HSC data. Our results are stable to variations in σ 8 and Ω c and we find constraints that agree well with measurements from Planck and low-redshift probes. Lastly, we use our pipeline to study the clustering of galaxies as a function of limiting flux, and provide a simple fitting function for the linear galaxy bias for magnitude limited samples as a function of limiting magnitude and redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

The growth of density perturbations in the last ~10 billion years from tomographic large-scale structure data

In order to investigate the origin of the ongoing tension between the amplitude of matter fluctuations measured by weak lensing experiments at low redshifts and the value inferred from the cosmic microwave background anisotropies, we reconstruct the evolution of this amplitude from z ~ 2 using existing large-scale structure data. To do so, we decouple the linear growth of density inhomogeneities from the background expansion, and constrain its redshift dependence making use of a combination of 6 different data sets, including cosmic shear, galaxy clustering and CMB lensing. We analyze these data under a consistent harmonic-space angular power spectrum-based pipeline. We show that current data constrain the amplitude of fluctuations mostly in the range 0.2 < z < 0.7, where it is lower than predicted by . This difference is mostly driven by current cosmic shear data, although the growth histories reconstructed from different data combinations are consistent with each other, and we find no evidence of systematic deviations in any particular experiment. In spite of the tension with , the data are well-described by the model, albeit with a lower value of S 8 ≡ σ 8 (Ω m /0.3) 0.5 . As part of our analysis, we find constraints on this parameter of S 8 = 0.7781 ± 0.0094 (68% confidence level), reaching almost percent-level errors comparable with CMB measurements, and 3.4σ away from the value found by .

79 ASTRONOMY AND ASTROPHYSICS↗

A generative modeling approach to reconstructing 21 cm tomographic data

Abstract Analyses of the cosmic 21 cm signal are hampered by astrophysical foregrounds that are far stronger than the signal itself. These foregrounds, typically confined to a wedge-shaped region in Fourier space, often necessitate the removal of a vast majority of modes, thereby degrading the quality of the data anisotropically. To address this challenge, we introduce a novel deep generative model based on stochastic interpolants to reconstruct the 21 cm data lost to wedge filtering. Our method leverages the non-Gaussian nature of the 21 cm signal to effectively map wedge-filtered 3D lightcones to samples from the conditional distribution of wedge-recovered lightcones. We demonstrate how our method is able to restore spatial information effectively, considering both varying cosmological initial conditions and astrophysics. Furthermore, we discuss a number of future avenues where this approach could be applied in analyses of the 21 cm signal, potentially offering new opportunities to improve our understanding of the Universe during the epochs of cosmic dawn and reionization. Code, pre-trained models, and scripts for making plots in this paper can be found here .

Sabti, Nashwan (ORCID:000000027924546X)↗

GLAD-M35: a joint P and S global tomographic model with uncertainty quantification

We present our third and final generation joint P and S global adjoint tomography (GLAD) model, GLAD-M35, and quantify its uncertainty based on a low-rank approximation of the inverse Hessian. Starting from our second-generation model, GLAD-M25, we added 680 new earthquakes to the database for a total of 2160 events. New P-wave categories are included to compensate for the imbalance between P- and S-wave measurements, and we enhanced the window selection algorithm to include more major-arc phases, providing better constraints on the structure of the deep mantle and more than doubling the number of measurement windows to 40 million. Two stages of a Broyden–Fletcher–Goldfarb–Shanno (BFGS) quasi-Newton inversion were performed, each comprising five iterations. With this BFGS update history, we determine the model’s standard deviation and resolution length through randomized singular value decomposition.

58 GEOSCIENCES↗

Tomographic Sparse View Selection Using the View Covariance Loss

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

Lin, Jingsong [Purdue University]↗

Oxidation and microstructure of SiC f /SiC composites in moist air up to 1600°C by X‐ray tomographic characterization

Abstract SiC f /SiC composites that possess PyC or BN interface layers were fabricated and then oxidized in moist air at 1000, 1200, 1400, and 1600°C. High‐resolution CT was used for capturing 3D images and quantifying the SiC phase, mesophase, and voids. The oxidation behavior and microstructural evolution of SiC f /SiC with PyC or BN interface are discussed in this study. The microstructure of the SiC f /SiC with a PyC layer was seriously damaged in moist air at high temperature, whereas the BN interface layer enhanced the oxidation resistance of the SiC f /SiC. These results are also confirmed by using XRD, oxidation mass gain, tensile testing, and SEM measurements. The results of the oxidation behavior and microstructural evolution for SiC f /SiC oxidized in dry air are also compared with the results of this study. Comparing the SiC f /SiC with a PyC interface layer, the composite with a BN interface layer oxidized in moist air exhibits a high void growth rate and a low SiO 2 grain growth rate from 1000 to 1600°C. This work will provide guidance for predicting the service life of SiC f /SiC for multiscale damage rate models of materials at a local scale and will also provide guidance on the life service design of SiC f /SiC materials.

Lu, Zilong↗