Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quantification of Vasa Vasorum Density in Multi-Slice Computed Tomographic Coronary Angiograms: Role of Computed Tomographic Image Voxel Size

This study is motivated by the possibility of using computed tomography (CT) to detect early coronary atherosclerosis by the increased CT values within the arterial wall resulting from vasa vasorum proliferation. Coronary arteries (n = 5) with early atherosclerotic changes were injected with Microfil and scanned (micro-CT). Noise was added to the CT projection data sets (to represent the radiation exposure of current clinical CT scanners) and then reconstructed to generate 3-dimensional images at different voxel sizes. Higher CT values were detected because of contrast agent in vasa vasorum if voxel size was less than (150 {micro}m){sup 3}. Contrast in the main lumen increased the CT values dramatically at voxels greater than (100 {micro}m){sup 3}, whereas CT values of the same specimen without contrast in the main lumen remained constant. Voxel sizes less than (200 {micro}m){sup 3} are needed to quantitate arterial wall opacification due to vasa vasorum proliferation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-E-J-252: A Motion Algorithm to Extract Physical and Motion Parameters of a Mobile Target in Cone-Beam Computed Tomographic Imaging Retrospective to Image Reconstruction

Purpose: A motion algorithm was developed to extract actual length, CT-numbers and motion amplitude of a mobile target imaged with cone-beam-CT (CBCT) retrospective to image-reconstruction. Methods: The motion model considered a mobile target moving with a sinusoidal motion and employed three measurable parameters: apparent length, CT number level and gradient of a mobile target obtained from CBCT images to extract information about the actual length and CT number value of the stationary target and motion amplitude. The algorithm was verified experimentally with a mobile phantom setup that has three targets with different sizes manufactured from homogenous tissue-equivalent gel material embedded into a thorax phantom. The phantom moved sinusoidal in one-direction using eight amplitudes (0–20mm) and a frequency of 15-cycles-per-minute. The model required imaging parameters such as slice thickness, imaging time. Results: This motion algorithm extracted three unknown parameters: length of the target, CT-number-level, motion amplitude for a mobile target retrospective to CBCT image reconstruction. The algorithm relates three unknown parameters to measurable apparent length, CT-number-level and gradient for well-defined mobile targets obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on actual length of the target and motion amplitude. The cumulative CT-number for a mobile target was dependent on CT-number-level of the stationary target and motion amplitude. The gradient of the CT-distribution of mobile target is dependent on the stationary CT-number-level, actual target length along the direction of motion, and motion amplitude. Motion frequency and phase did not affect the elongation and CT-number distributions of mobile targets when imaging time included several motion cycles. Conclusion: The motion algorithm developed in this study has potential applications in diagnostic CT imaging and radiotherapy to extract actual length, size and CT-numbers distorted by motion in CBCT imaging. The model provides further information about motion of the target.

60 APPLIED LIFE SCIENCES↗

Three-dimensional nanoscale reduced-angle ptycho-tomographic imaging with deep learning (RAPID)

X-ray ptychographic tomography is a nondestructive method for three dimensional (3D) imaging with nanometer-sized resolvable features. The size of the volume that can be imaged is almost arbitrary, limited only by the penetration depth and the available scanning time. Here we present a method that rapidly accelerates the imaging operation over a given volume through acquiring a limited set of data via large angular reduction and compensating for the resulting ill-posedness through deeply learned priors. The proposed 3D reconstruction method “RAPID” relies initially on a subset of the object measured with the nominal number of required illumination angles and treats the reconstructions from the conventional two-step approach as ground truth. It is then trained to reproduce equal fidelity from much fewer angles. After training, it performs with similar fidelity on the hitherto unexamined portions of the object, previously not shown during training, with a limited set of acquisitions. In our experimental demonstration, the nominal number of angles was 349 and the reduced number of angles was 21, resulting in a x140 aggregate speedup over a volume of 4.48 x 93.18 x 3.92 μm 3 and with (14nm) 3 feature size, i.e. ~ 10 8 voxels. RAPID’s key distinguishing feature over earlier attempts is the incorporation of atrous spatial pyramid pooling modules into the deep neural network framework in an anisotropic way. We found that adjusting the atrous rate improves reconstruction fidelity because it expands the convolutional kernels’ range to match the physics of multi-slice ptychography without significantly increasing the number of parameters.

47 OTHER INSTRUMENTATION↗

Collaborative Research: Tomographic imaging of laser-plasma structures

The interaction of intense short laser pulses with ionized gases, or plasmas, underlies many applications such as acceleration of elementary particles, production of energy by laser fusion, generation of x-ray and far-infrared “terahertz” pulses for medical and materials probing, remote sensing of explosives and pollutants, and generation of guide stars. Such laser-plasma interactions create tiny electron density structures (analogous to the wake behind a boat) inside the plasma in the shape of waves, bubbles and filaments that move at the speed of light, and evolve as they propagate. Prior to recent work by the PI of this proposal, detailed knowledge of such structures came exclusively from intensive computer simulations. Now “snapshots” of these elusive, light-velocity structures can be taken in the laboratory using dynamic variant of holography, the technique used to produce ID cards and DVDs, and dynamic variant of tomography, the technique used in medicine to image internal bodily organs. These fast visualization techniques are important for understanding, improving and scaling the above-mentioned applications of laser-plasma interactions. In this project, we accomplished three things: 1) We took holographic pictures of a laser-driven plasma-wave in the act of accelerating electrons to high energy, and used computer simulations to understand the pictures. 2) Using results from this experiment to optimize the performance of the accelerator, and the brightness of x-rays that it emits. These x-rays will be useful for medical and materials science applications. 3) We made technical improvements to the holographic technique that enables us to see finer details in the recorded pictures. Four refereed journal papers were published, and two students earned PhDs and moved on to scientific careers in US National Laboratories based on their work under this project.

43 PARTICLE ACCELERATORS↗

Microcomputed X-Ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

Microstructural characterization of composite high explosives (HEs) has become increasingly important over the last several decades in association with the development of high fidelity mesoscale modeling and an improved understanding of ignition and detonation processes. HE microstructure influences not only typical material properties (e.g., thermal, mechanical) but also reactive behavior (e.g., shock sensitivity, detonation wave shape). A detailed nondestructive 3D examination of the microstructure has generally been limited to custom-engineered samples or surrogates due to poor contrast between the composite constituents. Highly loaded (>90 wt%) HE composites such as plastic-bonded explosives (PBX) are especially difficult. Here, we present efforts to improve measurement quality by using single and dual-energy microcomputed X-ray tomography and state-of-the-art image processing techniques to study a broad set of HE materials. Some materials, such as PBX 9502, exhibit suitable contrast and resolution for an automatic segmentation of the HE from the polymer binder and the voids. Other composite HEs had varying levels of success in segmentation. Post-processing techniques that used commercially available algorithms to improve the segmentation quality of PBX 9501 as well as zero-density defects such as cracks and voids could be easily segmented for all samples. Aspects of the materials that lend themselves well to this type of measurement are discussed.

36 MATERIALS SCIENCE↗

Tomographic Imaging of the Fermi-LAT γ-Ray Sky through Cross-correlations: A Wider and Deeper Look

We investigate the nature of the extragalactic unresolved γ-ray background (UGRB) by cross-correlating several galaxy catalogs with sky maps of the UGRB built from 78 months of Pass 8 Fermi-Large Area Telescope data. This study updates and improves similar previous analyses in several aspects. First, the use of a larger γ-ray data set allows us to investigate the energy dependence of the cross-correlation in more detail, using up to eight energy bins over a wide energy range of [0.25,500] GeV. Second, we consider larger and deeper catalogs (2MASS Photometric Redshift catalog, 2MPZ; WISE × SuperCOSMOS, WI×SC; and SDSS DR12 photometric redshift data set) in addition to the ones employed in the previous studies (NVSS and SDSS QSOs). Third, we exploit the redshift information available for the above catalogs to divide them into redshift bins and perform the cross-correlation separately in each of them. Our results confirm, with higher statistical significance, the detection of cross-correlation signals between the UGRB maps and all the catalogs considered, on angular scales smaller than 1°. Significances range from 16.3σ for NVSS, 7σ for SDSS DR12 and WI×SC, to 5σ for 2MPZ and 4σ for SDSS QSOs. Furthermore, including redshift tomography, the significance of the SDSS DR12 signal strikingly rises up to ∼12σ and that of WI×SC to ∼10.6σ. We offer a simple interpretation of the signal in the framework of the halo model. The precise redshift and energy information allows us to clearly detect a change over redshift in the spectral and clustering behavior of the γ-ray sources contributing to the UGRB.

79 ASTRONOMY AND ASTROPHYSICS↗

Computerized tomographic imaging for space plasma physics

The measurement of plasma electron velocity distribution functions as a problem in imaging and image reconstruction is considered. A model instrument that measures the integral of the distribution function along lines in velocity space is presented. This allows the use of the powerful mathematical and numerical methods that have recently been so successful in other areas of imaging. It is found that this approach leads to classes of instruments that are qualitatively different from contemporary designs. An investigation of different methods of reconstruction of the distribution function from integral measurements reveals that the mathematical tools appropriate to one particular imaging problem may be very different from those required to deal with another.

Zhang, Yuhong↗

A rotating tomographic imager for solar extreme-ultraviolet/soft X-ray emission

A concept is presented for a high-resolution EUV/soft-X-ray imager that has much in common with the medical imaging procedure of tomography. The resulting instrument is compatible with a simpler, less costly spin-axis-stabilized spacecraft. To demonstrate the fidelity of the reconstruction procedure, the observation and reconstruction is simulated to compare the results with the original image.

Davila, Joseph M.↗

Tomographic Imaging Of Low-Density Inclusions

Computed neutron tomography reveals structure of volume containing material of lesser density surrounded by material of greater density. Technique used, for example, to examine and measure flaws or other inclusions containing equally dense or less-dense material hidden in complicated structure made of denser material.

Roy, Jagatjit↗

Tomographic Imaging of the Suns Interior

A new method is presented of determining the three-dimensional sound-speed structure and flow velocities in the solar convection zone by inversion of the acoustic travel-time data recently obtained by Duvall and coworkers. The initial inversion results reveal large-scale subsurface structures and flows related to the active regions, and are important for understanding the physics of solar activity and large-scale convection. The results provide evidence of a zonal structure below the surface in the low-latitude area of the magnetic activity. Strong converging downflows, up to 1.2 km/s, and a substantial excess of the sound speed are found beneath growing active regions. In a decaying active region, there is evidence for the lower than average sound speed and for upwelling of plasma.

Kosovichev, A. G.↗

Time-resolved diffusion tomographic imaging in highly scattering turbid media

A method for imaging objects in highly scattering turbid media. According to one embodiment of the invention, the method involves using a plurality of intersecting source/detectors sets and time-resolving equipment to generate a plurality of time-resolved intensity curves for the diffusive component of light emergent from the medium. For each of the curves, the intensities at a plurality of times are then inputted into the following inverse reconstruction algorithm to form an image of the medium: X.sup.(k+1).spsp.T =?Y.sup.T W+X.sup.(k).spsp.T .LAMBDA.!?W.sup.T W+.LAMBDA.!.sup.-1 wherein W is a matrix relating output at detector position r.sub.d, at time t, to source at position r.sub.s, .LAMBDA. is a regularization matrix, chosen for convenience to be diagonal, but selected in a way related to the ratio of the noise, to fluctuations in the absorption (or diffusion) X.sub.j that we are trying to determine: .LAMBDA..sub.ij =.lambda..sub.j .delta..sub.ij with .lambda..sub.j = /<.DELTA.Xj.DELTA.Xj> Here Y is the data collected at the detectors, and X.sup.k is the kth iterate toward the desired absoption information.

Alfano, Robert R.↗

Tomographic Imaging of Water Injection and Withdrawal in PEMFC Gas Diffusion Layers

X-ray computed tomography was used to visualize the water configurations inside gas diffusion layers for various applied capillary pressures, corresponding to both water invasion and withdrawal. A specialized sample holder was developed to allow capillary pressure control on the small-scale samples required. Tests were performed on GDL specimens with and without hydrophobic treatments.

47 OTHER INSTRUMENTATION↗

Reflective echo tomographic imaging using acoustic beams

An inspection system includes a plurality of acoustic beamformers, where each of the plurality of acoustic beamformers including a plurality of acoustic transmitter elements. The system also includes at least one controller configured for causing each of the plurality of acoustic beamformers to generate an acoustic beam directed to a point in a volume of interest during a first time. Based on a reflected wave intensity detected at a plurality of acoustic receiver elements, an image of the volume of interest can be generated.

36 MATERIALS SCIENCE↗