Search NASA⌕ Search

SEARCH · Search NASA

Results for “tone tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

57 records · Page 4

NASA Tech Briefs, August 2008

Customizable Digital Receivers for Radar Two-Camera Acquisition and Tracking of a Flying Target Visual Data Analysis for Satellites A Data Type for Efficient Representation of Other Data Types Hand-Held Ultrasonic Instrument for Reading Matrix Symbols Broadband Microstrip-to-Coplanar Strip Double-Y Balun A Topographical Lidar System for Terrain-Relative Navigation Programmable Low-Voltage Circuit Breaker and Tester Electronic Switch Arrays for Managing Microbattery Arrays Topics covered include: Lower-Dark-Current, Higher-Blue-Response CMOS Imagers; Fabricating Large-Area Sheets of Single-Layer Graphene by CVD; Support for Diagnosis of Custom Computer Hardware; Providing Goal-Based Autonomy for Commanding a Spacecraft; Dynamic Method for Identifying Collected Sample Mass; Optimal Planning and Problem-Solving; Attitude-Control Algorithm for Minimizing Maneuver Execution Errors; Grants Document-Generation System; Heat-Storage Modules Containing LiNO3 3H2O and Graphite Foam; Precipitation-Strengthened, High-Temperature, High-Force Shape Memory Alloys; Improved Relief Valve Would Be Less Susceptible to Failure; Safety Modification of Cam-and-Groove Hose Coupling; Using Composite Materials in a Cryogenic Pump; Using Electronic Noses to Detect Tumors During Neurosurgery; Producing Newborn Synchronous Mammalian Cells; Smaller, Lower-Power Fast-Neutron Scintillation Detectors; Rotationally Vibrating Electric-Field Mill; Estimating Hardness from the USDC Tool-Bit Temperature Rise; Particle-Charge Spectrometer; Automated Production of Movies on a Cluster of Computers; FIDO-Class Development Rover; and Tone-Based Command of Deep Space Probes Using Ground Antennas.

Source record↗

Characterizing Methods of Measuring Flow-Mediated Dilation in the Brachial Artery

Regulation of vascular tone is one of the many important functions of the vascular endothelium. Endothelial dysfunction is a critical early event in the pathogenesis of atherosclerosis and occurs in the absence of angiographic disease. Flow-Mediated Dilation (FMD) is a noninvasive technique commonly used to evaluate endothelium-dependent vasodilation in humans and gauge the health of the cardiovascular system. Reductions in brachial artery FMD have been strongly correlated with disease progression and are predictive of future cardiac events. The flow stimulus for brachial artery FMD occurs as a result of the increased shear stress following deflation of an occlusion cuff around the upper arm. Using 2-dimensional ultrasound, changes in arterial diameter up to 5-minutes following cuff deflation are calculated from baseline image measurements. Along with pulsed Doppler measures of flow velocity through the artery, flow-mediated, endothelium-dependent vasodilation can be assessed. There is debate among investigators, however, about the proper positioning of the occlusion cuff during FMD testing. It is thought that placement of the cuff around the upper arm may not accurately reflect the impact of nitric oxide, a critically important molecule released as a result of the increased shear stress created by the FMD technique. Data suggest that the production of other endogenous metabolites may also contribute to FMD-related changes when positioning the cuff around the upper arm. To overcome the potential influence of such molecules, researchers now suggest that the occlusion cuff be placed below the elbow allowing a more precise estimate of nitric oxide mediated dilation. The purpose of this study is to compare the differences in FMD between the two methodologies of occlusion cuff placement. In addition, this study will determine the method that is easier for ultrasound technicians to perform and will produce a low coefficient of variance between technicians. Ultimately, the results of this study will help in tracking any adverse cardiovascular effects of spaceflight.

Callender, Ariane R.↗

Effects of Long Duration Space Flight on Low Frequency Hearing

Pure tone hearing threshold data has been collected on astronauts since the early days of spaceflight. Between 1981 and 2001 (STS-1 thru 108) it was found that of the 608 shuttle astronauts, 17% returned home with a significant hearing threshold shift, and of that 6% had permanent changes in the high frequencies. Believed to be due to prolonged noise exposure on the space crafts. (Hart, 2006) As NASA aimed for longer duration missions the uncertainty about the effects of month-long noise exposure needed to be addressed. To avoid constraining crewmembers to constant earplug usage, and satisfying budget demands, a focused effort on overcoming the issues began. Noise monitoring systems were introduced onto the International Space Station (ISS) and astronauts were given education on the noise environment aboard the ISS, the hazards of noise induced hearing loss, hearing conservation principles, and countermeasure strategies (earplugs, noise cancellation headsets). As well as being trained on a new countermeasure effort that had been in trial testing on prior shuttle missions (STS-6 thru 8), On-Orbit Hearing Assessment (OOHA). (Hart, 2006) OOHA was implemented to routinely monitor the hearing thresholds of crewmembers who are on orbit for longer than 30 days. Flight Surgeons on ground monitor these test for significant hearing changes while aboard. Between 2000 and 2021 the ISS OOHA system (EarQ) recorded changes in the low frequency hearing thresholds. Low frequency hearing changes are not typically caused by noise exposure, and it was initially believed that these changes were due to environmental noise interference. In 2021 an ISS software upgrade (KUDUwave) allowed for a more comprehensive hearing assessment. The new testing system allowed for additional tests that helped describe the type of hearing loss being experienced and determine the influence of ambient noise or other environmental factors. OOHA Data indicates a low frequency hearing shift in 40% of all tests and 60% of all crewmembers. Since 2021, OOHA results (using the KUDUwave) suggest that these shifts are sensorineural and are not the result of ambient noise. While hearing shifts are seen at both 250 and 500 Hz, metrics tracking these shifts have only used 500 Hz data. The lack of 250 Hz has prevented accurate reporting of low frequency hearing shift recovery. The aim of this study is to capture 250 Hz data and accurately present low frequency hearing loss recovery.

hearing↗