At least 73 records · Page 4

Turbulent properties of a compressible boundary layer.

Turbulent shear-stress, eddy-viscosity, mixing-length, heat-flux and Prandtl number distributions across a hypersonic turbulent boundary layer have been determined from the 'time-averaged' conservation equations using experimental mean profile data obtained at several streamwise locations in a fully developed turbulent boundary layer with negligible pressure gradient. The eddy-viscosity, mixing-length and Prandtl number results show general agreement with previous incompressible and adiabatic compressible correlations. However, when the turbulent Prandtl number is defined using total enthalpy as opposed to static enthalpy no clear correlation of the results in the outer portion of the boundary layer could be obtained.

Horstman, C. C.↗

Transonic laminar boundary layers with surface curvature.

The effect of surface curvature (both longitudinal and transverse) and the associated pressure gradient across the flow is investigated analytically for a laminar boundary layer subjected to pressure gradients along the flow. Property variation which results from heat transfer and compressibility is taken into account. Numerical solutions of the boundary layer equations are obtained for locally similar sonic flow through the throat of a nozzle for a range of flow conditions and for various shaped nozzle surfaces with different amounts of wall cooling. A few solutions were also obtained for the analogous flow around the shoulder of a flat-faced body in a supersonic flow. The effect of various parameters that arise in the equations upon application of the Levy-Mangler transformation are investigated and discussed with respect to their influence on the velocity and total enthalpy profiles and the corresponding profile slopes at the surface to which the shear stress and heat transfer are related. An important finding is that at throat Reynolds numbers less than 100,000 the heat transfer parameter at a nozzle throat decreases as the throat radius of curvature decreases.

Back, L. H.↗

Recent developments on time-dependent calculation of nonequilibrium flows

It is shown that, in a time-dependent nonequilibrium flow analysis, erroneous and unstable solutions can result from the use of temperature equations and flow variables other than pressure in fitting the bow shock. A formulation is presented that has been critically evaluated by comparison with a previous one and found to yield steady and more accurate solutions in conserving total enthalpy.

Li, C. P.↗

Measurement techniques for supersonic combustion testing

Measurement techniques used during nine years of intensive research in supersonic combustion are presented. The tests employed a number of combustor and injector configurations, which were directly connected to a Mach 3.2 supersonic nozzle, and both gaseous hydrogen and storable liquid fuels. Nominal plenum conditions for the arc-heated air were 3000 to 4500 R and 30 atm. Measurements included wall surface pressures, wall temperatures, heat flux, skin friction, instream cone-static and pitot pressures, and gas samples. Measurement and analysis techniques have been developed for determining total enthalpy of an airstream containing NO concentrations in excess of equilibrium using the two-throat technique, bulk combustion efficiency using steam calorimetry, radial gradients of fluid properties in the combustor exit plane using a stream tube method, and wall shear from measurements of heat transfer in a reacting supersonic flow using Reynolds analogy.

Orth, R. C.↗

The Langley thermal protection system test facility: A description including design operating boundaries

A description of the Langley thermal protection system test facility is presented. This facility was designed to provide realistic environments and times for testing thermal protection systems proposed for use on high speed vehicles such as the space shuttle. Products from the combustion of methane-air-oxygen mixtures, having a maximum total enthalpy of 10.3 MJ/kg, are used as a test medium. Test panels with maximum dimensions of 61 cm x 91.4 cm are mounted in the side wall of the test region. Static pressures in the test region can range from .005 to .1 atm and calculated equilibrium temperatures of test panels range from 700 K to 1700 K. Test times can be as long as 1800 sec. Some experimental data obtained while using combustion products of methane-air mixtures are compared with theory, and calibration of the facility is being continued to verify calculated values of parameters which are within the design operating boundaries.

Klich, G. F.↗

Heat-transfer and pressure measurements on a simulated elevon deflected 30 deg near flight conditions at Mach 7

Heat transfer rates and pressures were obtained on an elevon plate (deflected 30 deg) and a flat plate upstream of the elevon in an 8 foot high-temperature structures tunnel. The flight Reynolds number and flight total enthalpy for altitudes of 26.8 km and 28.7 km at Mach seven were duplicated. The heat transfer and pressure data were used to establish heating and pressure loads. The measured heating was compared with several theoretical predictions, and the closest agreement obtained with a Schultz-Grunow reference enthalpy method of calculation.

Johnson, C. B.↗

Flight boundary layer transition measurements on a slender cone at Mach 20

Experimental flight boundary layer transition data have been obtained on a 3.962-m-long, 5 deg half-angle cone with an initial nose radius of 0.254 cm. The data were obtained during re-entry from altitudes of approximately 30.480 to 18.288 km at a free-stream Mach number of 20. The free-stream Reynolds number varied from 6.56 x 10 to the 6th/m to 52.5 x 10 to the 6th/m, and the total enthalpy from about 18.3 to 16.9 MJ/kg. The locations of the beginning and end of transition were determined by the intersection of curves faired throug the laminar, transitional, and turbulent heating-rate data. The temperature-history technique for determining transition as currently used (sharp break in curve) was shown to compare unfavorably with the heating-rate-distribution method. The heating-rate-history technique, which is proportional to the temperature derivative and consequently more sensitive to perturbations, gives better agreement with the heating-rate distribution transition results.

Wright, R. L.↗

A correlation of mixing noise from coannular jets with inverted flow profiles

Data are correlated for jet mixing noise from coannular jets with inverted flow velocity profiles. The acoustic performance of coannular jets is compared to the performance of a hypothetical single jet with the same total mass flow, thrust, and total enthalpy flow as the coannular jet. The study shows that coannular jets with velocity ratios greater than 1.2 produce less noise than their corresponding equivalent tests and that optimum noise reduction of coannular jets in the data set occurs within a range of equivalent velocities between 500 and 700 meters per second and velocity ratios between 1.6 and 2.3. The maximum sound power reduction is found to be about 4 decibels. Directivity indices and a special set of spectral curves were developed to describe the characteristic double peak spectra of coannular jet noise. The temperature ratio between the inner and outer streams was not found to be important in this acoustic correlation. However, the mean temperature effect was included in the computations of sound pressure levels.

Pao, S. P.↗

Operating characteristics of the Langley Mach 7 Scramjet Test Facility

Operating characteristics of the Langley Mach 7 Scramjet Test Facility are described. The facility is designed for testing airframe integrated scramjet (supersonic combustion ramjet) engine models. Features include duplication of the flight Mach number total enthalpy, flight altitude simulation, and simulation of engine airframe integration effects such a bow shock wave precompression and boundary layer ingestion by the engine. Data obtained from facility calibration and from tests of a hydrogen burning, airframe integrated scramjet are discussed. An adverse interaction between the facility flow and the scramjet engine flow during combustion of the fuel is described.

Guy, R. W.↗

Topology of vortices in conical flow

The possibility of the existence of a viscous vortex in a conical flow is discussed. Existence of a viscous vortex is shown to be consistent with a flow-field model where only the velocity components and the total enthalpy behave conically. Existence of a viscous vortex is not consistent with the fully conical, flow-field model; however, far from the nose tip, the physical flow quantities tend to behave asymptotically as a full conical flow. Such a viscous vortex, when it exists, must spiral inwards to the focal point. It can be used as a reasonable model to start numerical solutions of various kinds.

Almosnino, D.↗

The Moist Available Energy of a Conditionally Unstable Atmosphere

Two simple methods for computing the moist available energy for cases in which the total number of parcels is fairly small are discussed. The first is a swapping routine that finds the reference state by exchanging parcels whenever the swap reduces the total enthalpy. However, it can be proved by contrived example that the swapping algorithm does not always find the true reference state. A second brute force routine actually examines all possible arrangements of the parcels and chooses the one with the smallest moist enthalpy. At present, both routines allow only horizontally homogeneous reference states. In an exploratory study, the swapping routine was used to find MAE and reference state for a time sequence of GATE soundings, all of which are conditionally unstable. In spot checks, the brute force routine always agreed with the swapper. Results show that in passing from the given state of the reference state the lowest three hundred mb of the atmosphere typically exchanges places with the 300 mb above it. The reference state then contains a dry warm layer near the surface, but a supersaturated but cool layer in the middle troposphere. The upper portion of the sounding is not modified in passing from the given state to the reference state.

Randall, D.↗

A finite element solution of three-dimensional inviscid rotational flows through curved ducts

A previously developed two-dimensional finite element algorithm for the solution of steady Euler equations is extended to three-dimensional problems. Starting with the general three-dimensional problem, the formulation of steady, rotational flows is presented. The boundary conditions for steady flows where the rotationality is introduced through entropy or total enthalpy gradients are introduced. A three-dimensional flow through a curved duct is analyzed as a sample problem, demonstrating the efficiency of the relaxation scheme. The accuracy of the numerical results is investigated by calculating the velocity and vorticity distributions at different sections of the channel, including the exit.

Ecer, A.↗

Coupling conditions for integrating boundary layer and rotational inviscid flow

The matching of a boundary layer and a rotational inviscid flow is reexamined by extending the Johnson and Sockol (1979) coupling conditions to include the case where the boundary layer solution includes the second-order effects of the freestream vorticity and the total temperature gradient. It is pointed out that two of the three conditions are not independent. If the boundary layer solution satisfies the appropriate momentum and energy integral equations, it follows that the imposition of the normal mass flux condition insures that the conditions on a normal flux of streamwise momentum and total enthalpy will also be satisfied.

Sockol, P. M.↗

Aerothermal tests of quilted dome models on a flat plate at a Mach number of 6.5

Aerothermal tests were conducted in the NASA Langley 8 Foot High Temperature Tunnel (8'HTT) at a Mach number of 6.5 on simulated arrays of thermally bowed metallic thermal protection system (TPS) tiles at an angle of attack of 5 deg. Detailed surface pressures and heating rates were obtained for arrays aligned with the flow and skewed 45 deg diagonally to the flow with nominal bowed heights of 0.1, 0.2, and 0.4 inch submerged in both laminar and turbulent boundary layers. Aerothermal tests were made at a nominal total temperature of 3300 R, a total pressure of 400 psia, a total enthalpy of 950 Btu/lbm, a dynamic pressure of 2.7 psi, and a unit Reynolds number of 400,000 per foot. The experimental results form a data base that can be used to help protect aerothermal load increases from bowed arrays of TPS tiles.

Glass, Christopher E.↗

Algorithm For Hypersonic Flow In Chemical Equilibrium

Implicit, finite-difference, shock-capturing algorithm calculates inviscid, hypersonic flows in chemical equilibrium. Implicit formulation chosen because overcomes limitation on mathematical stability encountered in explicit formulations. For dynamical portion of problem, Euler equations written in conservation-law form in Cartesian coordinate system for two-dimensional or axisymmetric flow. For chemical portion of problem, equilibrium state of gas at each point in computational grid determined by minimizing local Gibbs free energy, subject to local conservation of molecules, atoms, ions, and total enthalpy. Major advantage: resulting algorithm naturally stable and captures strong shocks without help of artificial-dissipation terms to damp out spurious numerical oscillations.

Palmer, Grant↗

Calculation of convective heat transfer on highly blunt bodies at flow incidence

An implicit finite-difference code is used to study three-dimensional viscous heat-conducting flows over the forebody of hypersonic vehicles. In the method, adaptive grids are generated to the shock and body contour, and local flow gradients and total enthalpy are used to control numerical dissipation. Typical axisymmetric configurations of a sphere, ellipsoid, and flat-face disk are considered, along with the cases of a blunt 70-deg cone at 0 and 20 deg flow incidences and an asymmetric 60-deg cone raked off at a 73-deg angle.

Li, C. P.↗

Calculations of rotational flows using stream function

The stream function equation is solved for steady two-dimensional (and axisymmetric) rotational flows. Both finite differences and finite volumes discretization techniques are studied, using generalized body fitted coordinates and unstructured staggered grids, respectively. For inviscid transonic flows, a new artificial viscosity scheme which does not produce any artificial vorticity is introduced, for the stability of the mixed flow calculations and for capturing shocks. The solution of Euler equations, in primitive variables, are also considered. The effects of the artificial viscosity and numerical boundary conditions on the total enthalpy and the vorticity distributions are demonstrated.

Hafez, M.↗

Prediction of unsteady rotor-surface heat transfer from wake passings

Predictions using boundary-layer theory with a low-Reynolds number kinetic-energy/dissipation turbulence model are reported for the unsteady heat-flux distributions on the rotor blade surfaces. With an assumed sinusoidal variation for the unsteady surface pressure depicting the effects of convected wake segments, unsteady inviscid-freestream velocity and total enthalpy distributions are determined. Unsteady variations in freestream turbulence due to the wake passings are also considered. The unsteady boundary-layer equations, subject to these freestream conditions, are solved numerically. It was found that most of the unsteady variations in surface heat transfer are due to unsteady pressure changes and not variations in the freestream turbulence. Calculations are made for the Garrett TFE 731-2 HP turbine and the magnitudes of the heat-transfer variations are compared with the measurements of Dunn and Seymour.

Taulbee, Dale B.↗